977 resultados para Super Austenitic Stainless Steel


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polythiophene (PTh) phase electropolymerized on the stainless steel wire was evaluated as solid-phase microextraction (SPME), and analysis by liquid chromatography with spectrophotometric detection (LC-UV) for determination of new-generation antidepressants, selective serotonin reuptake inhibitors (SSRIs) (citalopram, paroxetine, fluoxetine and sertraline), in plasma samples. The influence of electropolymerization variables (scan rate, potential range and scan cycles) was evaluated on SPME performance. The SPME variables (extraction time, temperature, matrix pH, ionic strength and desorption procedure), as well as the influence of plasma proteins on sorption mechanisms were also evaluated. The SPME/LC-UV method developed for determination of antidepressants in plasma sample presented a linear range between the limit of quantification (LOQ, 200-250 ng mL-1) to 4000 ng mL-1, and interday precision with coefficient of variation (CV) ranged from 11 to 15%. The proposed method can be a useful tool for the determination of antidepressants in human plasma samples in urgent toxicological analysis after the accidental or suicidal intake of higher doses of medications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to compare the effects of active and passive lacebacks on antero-posterior position of maxillary first molars and central incisors during leveling phase. Twenty-three subjects with Class I and Class II malocclusion were treated with first premolars extraction using preadjusted appliances (MBT 0.022-inch brackets). The leveling phase was performed with stainless steel archwires only. The sample was divided into 2 groups: 14 subjects received active lacebacks (Group 1) and 9 subjects received passive lacebacks (Group 2). Lacebacks were made from 0.008-inch ligature wire. Lateral cephalometric radiographs were taken pre- and post-leveling phase. Student's t-test was applied to determine the differences between pre- and post-leveling mean values and to determine the mean differences between groups. In Group I, the first molars showed a significant mesial movement, whereas no change was observed in Group 2. In both groups, maxillary central incisor crowns moved to lingual side. In conclusion, active laceback produced anchorage loss of maxillary first molars whereas passive laceback did not affect the position of these teeth. Active and passive lacebacks were effective in preventing central incisor proclination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the effectiveness of different sealants applied to a nanofiller composite resin. Forty specimens of Filtek Z-350 were obtained after inserting the material in a 6x3 mm stainless steel mold followed by light activation for 20 s. The groups were divided (n=10) according to the surface treatment applied: Control group (no surface treatment), Fortify, Fortify Plus and Biscover LV. The specimens were subjected to simulated toothbrushing using a 200 g load and 250 strokes/min to simulate 1 week, 1, 3 and 6 months and 1 and 3 years in the mouth, considering 10,000 cycles equivalent to 1 year of toothbrushing. Oral-B soft-bristle-tip toothbrush heads and Colgate Total dentifrice at a 1:2 water-dilution were used. After each simulated time, surface roughness was assessed in random triplicate readings. The data were submitted to two-way ANOVA and Tukey's test at a 95% confidence level. The specimens were observed under scanning electron microscopy (SEM) after each toothbrushing cycle. The control group was not significantly different (p>0.05) from the other groups, except for Fortify Plus (p<0.05), which was rougher. No significant differences (p>0.05) were observed at the 1-month assessment between the experimental and control groups. Fortify and Fortify Plus presented a rougher surface over time, differing from the baseline (p<0.05). Biscover LV did not differ (p>0.05) from the baseline at any time. None of the experimental groups showed a significantly better performance (p>0.05) than the control group at any time. SEM confirmed the differences found during the roughness testing. Surface penetrating sealants did not improve the roughness of nanofiller composite resin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CO(15NH2)2 enriched with the stable isotope 15N was synthesized based on a reaction involving CO, 15NH3, and S in the presence of CH3OH. The method differs from the industrial method; a stainless steel reactor internally lined with polytetrafluoroethylene (PTFE) was used in a discontinuous process under low pressure and temperature. The yield of the synthesis was evaluated as a function of the parameters: the amount of reagents, reaction time, addition of H2S, liquid solution and reaction temperature. The results showed that under optimum conditions (1.36, 4.01, and 4.48 g of 15NH3, CO, and S, respectively, 40 ml CH3OH, 40 mg H2S, 100 ºC and 120 min of reaction) 1.82 g (yield 76.5%) of the compound was obtained per batch. The synthesized CO(15NH2)2 contained 46.2% N, 0.55% biuret, melting point of 132.55 ºC and did not exhibit isotopic fractionation. The production cost of CO(15NH2)2 with 90.0 at. % 15N was US$ 238.60 per gram.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To describe and compare three alternative methods for controlling classical friction: Self-ligating brackets (SLB), special brackets (SB) and special elastomeric ligatures (SEB). METHODS: The study compared Damon MX, Smart Clip, In-Ovation and Easy Clip self-ligating bracket systems, the special Synergy brackets and Morelli's twin bracket with special 8-shaped elastomeric ligatures. New and used Morelli brackets with new and used elastomeric ligatures were used as control. All brackets had 0.022 x 0.028-in slots. 0.014-in nickel-titanium and stainless steel 0.019 x 0.025-in wires were tied to first premolar steel brackets using each archwire ligation method and pulled by an Instron machine at a speed of 0.5 mm/minute. Prior to the mechanical tests the absence of binding in the device was ruled out. Statistical analysis consisted of the Kruskal-Wallis test and multiple non-parametric analyses at a 1% significance level. RESULTS: When a 0.014-in archwire was employed, all ligation methods exhibited classical friction forces close to zero, except Morelli brackets with new and old elastomeric ligatures, which displayed 64 and 44 centiNewtons, respectively. When a 0.019 x 0.025-in archwire was employed, all ligation methods exhibited values close to zero, except the In-Ovation brackets, which yielded 45 cN, and the Morelli brackets with new and old elastomeric ligatures, which displayed 82 and 49 centiNewtons, respectively. CONCLUSIONS: Damon MX, Easy Clip, Smart Clip, Synergy bracket systems and 8-shaped ligatures proved to be equally effective alternatives for controlling classical friction using 0.014-in nickel-titanium archwires and 0.019 x 0.025-in steel archwires, while the In-Ovation was efficient with 0.014-in archwires but with 0.019 x 0.025-in archwires it exhibited friction that was similar to conventional brackets with used elastomeric ligatures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The opinion on the 'straight-wire' concept has been evolving since its origin, characterized by faithful followers or absolute skepticism. Currently, it seems reasonable to state that most professionals have a more realistic and critical viewpoint, with an attitude that reveals Orthodontics' maturity and greater knowledge on the technique. The most relevant criticisms refer to the impossibility of the both the Straight-Wire and the Standard systems to completely express the characteristics related to the brackets due to mechanical deficiencies, such as bracket/wire play. OBJECTIVES: A critical analysis of this relationship, which is unclear due to lack of studies, was the scope of this paper. METHODS: The compensatory treatment of two patients, using Capelozza's individualized brackets, works as the scenery for cephalometric evaluation of changes in incisor inclination produced by different dimensions of leveling archwires. RESULTS: The evaluation of these cases showed that, while the introduction of a 0.019 x 0.025-in stainless steel archwire in a 0.022 x 0.030-in slot did not produce significant changes in incisor inclination, the 0.021 x 0.025-in archwire was capable of changing it, mainly in mandibular incisors, and in the opposite direction to the compensation. CONCLUSION: Considering compensatory treatments, even when using an individualized prescription according to the malocclusion, the bracket/wire play seems to be a positive factor for malocclusion correction, without undesirable movements. Therefore, it seems reasonable to admit that, until a bracket system can have absolute individualization, the use of rectangular wires that still have a certain play with the bracket slot is advisable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rostral ventrolateral medulla (RVLM) contains the presympathetic neurons involved in cardiovascular regulation that has been implicated as one of the most important central sites for the antihypertensive action of moxonidine (an α2-adrenergic and imidazoline agonist). Here, we sought to evaluate the cardiovascular effects produced by moxonidine injected into another important brainstem site, the commissural nucleus of the solitary tract (commNTS). Mean arterial pressure (MAP), heart rate (HR), splanchnic sympathetic nerve activity (sSNA) and activity of putative sympathoexcitatory vasomotor neurons of the RVLM were recorded in conscious or urethane-anesthetized, and artificial ventilated male Wistar rats. In conscious or anesthetized rats, moxonidine (2.5 and 5 nmol/50 nl) injected into the commNTS reduced MAP, HR and sSNA. The injection of moxonidine into the commNTS also elicited a reduction of 28% in the activity of sympathoexcitatory vasomotor neurons of the RVLM. To further assess the notion that moxonidine could act in another brainstem area to elicit the antihypertensive effects, a group with electrolytic lesions of the commNTS or sham and with stainless steel guide-cannulas implanted into the 4th V were used. In the sham group, moxonidine (20 nmol/1 μl) injected into 4th V decreased MAP and HR. The hypotension but not the bradycardia produced by moxonidine into the 4th V was reduced in acute (1 day) commNTS-lesioned rats. These data suggest that moxonidine can certainly act in other brainstem regions, such as commNTS to produce its beneficial therapeutic effects, such as hypotension and reduction in sympathetic nerve activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Injections of noradrenaline into the lateral parabrachial nucleus (LPBN) increase arterial pressure and 1.8% NaCl intake and decrease water intake in rats treated with the diuretic furosemide (FURO) combined with a low dose of the angiotensin converting enzyme inhibitor captopril (CAP). In the present study, we investigated the influence of the pressor response elicited by noradrenaline injected into the LPBN on FURO+CAP-induced water and 1.8% NaCl intake. Male Holtzman rats with bilateral stainless steel guide-cannulas implanted into LPBN were used. Bilateral injections of noradrenaline (40 nmol/0.2 μl) into the LPBN increased FURO+CAP-induced 1.8% NaCl intake (12.2±3.5, vs., saline: 4.2±0.8 ml/180 min), reduced water intake and strongly increased arterial pressure (50±7, vs. saline: 1±1 mmHg). The blockade of the α1 adrenoceptors with the prazosin injected intraperitoneally abolished the pressor response and increased 1.8% NaCl and water intake in rats treated with FURO+CAP combined with noradrenaline injected into the LPBN. The deactivation of baro and perhaps volume receptors due to the cardiovascular effects of prazosin is a mechanism that may facilitate water and NaCl intake in rats treated with FURO+CAP combined with noradrenaline injected into the LPBN. Therefore, the activation of α2 adrenoceptors with noradrenaline injected into the LPBN, at least in dose tested, may not completely remove the inhibitory signals produced by the activation of the cardiovascular receptors, particularly the signals that result from the extra activation of these receptors with the increase of arterial pressure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Peripheral treatment with the cholinergic agonist pilocarpine increases salivary gland blood flow and induces intense salivation that is reduced by the central injection of moxonidine (α(2)-adrenoceptors/imidazoline agonist). In the present study, we investigated the effects of the intracerebroventricular (i.c.v.) injection of pilocarpine alone or combined with moxonidine also injected i.c.v. On submandibular/sublingual gland (SSG) vascular resistance. In addition, the effects of these treatments on arterial pressure, heart rate and on mesenteric and hindlimb vascular resistance were also tested. DESIGN: Male Holtzman rats with stainless steel cannula implanted into lateral ventricle and anaesthetized with urethane+α-chloralose were used. RESULTS: Pilocarpine (500nmol/1μl) injected i.c.v. Reduced SSG vascular resistance and increased arterial pressure, heart rate and mesenteric vascular resistance. Contrary to pilocarpine alone, the combination of moxonidine (20nmol/1μl) and pilocarpine injected i.c.v. Increased SSG vascular resistance, an effect abolished by the pre-treatment with the α(2)-adrenoceptor antagonist yohimbine (320nmol/2μl). The increase in arterial pressure, heart rate and mesenteric resistance was not modified by the combination of moxonidine and pilocarpine i.c.v. CONCLUSION: These results suggest that the activation of central α(2)-adrenoceptors may oppose to the effects of central cholinergic receptor activation in the SSG vascular resistance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental two-phase frictional pressure drop and flow boiling heat transfer results are presented for a horizontal 2.32-mm ID stainless-steel tube using R245fa as working fluid. The frictional pressure drop data was obtained under adiabatic and diabatic conditions. Experiments were performed for mass velocities ranging from 100 to 700 kg m−2 s−1 , heat flux from 0 to 55 kW m−2 , exit saturation temperatures of 31 and 41◦C, and vapor qualities from 0.10 to 0.99. Pressures drop gradients and heat transfer coefficients ranging from 1 to 70 kPa m−1 and from 1 to 7 kW m−2 K−1 were measured. It was found that the heat transfer coefficient is a strong function of the heat flux, mass velocity, and vapor quality. Five frictional pressure drop predictive methods were compared against the experimental database. The Cioncolini et al. (2009) method was found to work the best. Six flow boiling heat transfer predictive methods were also compared against the present database. Liu and Winterton (1991), Zhang et al. (2004), and Saitoh et al. (2007) were ranked as the best methods. They predicted the experimental flow boiling heat transfer data with an average error around 19%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN] This article describes a photocatalytic nanostructured anatase coating deposited by cold gas spray (CGS) supported on titanium sub-oxide (TiO22x) coatings obtained by atmospheric plasma spray (APS) onto stainless steel cylinders. The photocatalytic coating was homogeneous and preserved the composition and nanostructure of the starting powder. The inner titanium sub-oxide coating favored the deposition of anatase particles in the solid state. Agglomerated nano-TiO2 particles fragmented when impacting onto the hard surface of the APS TiO22x bond coat. The rough surface provided by APS provided an ideal scenario for entrapping the nanostructured particles, which may be adhered onto the bond coat due to chemical bonding; a possible bonding mechanism is described. Photocatalytic experiments showed that CGS nano-TiO2 coating was active for photodegrading phenol and formic acid under aqueous conditions. The results were similar to the performance obtained by competitor technologies and materials such as dip-coating P25 photocatalysts. Disparity in the final performance of the photoactive materials may have been caused by differences in grain size and the crystalline composition of titanium dioxide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This Thesys reports the study of a HGMS (High GradientMagnetic Separation) process for the treatment of industrialwastewaters that considers an assisted chemical-physical pre-treatment for the removal of heavy metals through the bound by adsorption with added iron-oxide particulate matter (hematite). The considered filter, constituted by ferromagnetic stainless steel wool and permanent magnets, is studied with a new approach based on a statistical analysis that requires the study of the trajectories of the particles. Experimental activity on a laboratory device has been carried out in order to test the model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Revascularisation with Titanium-Nitride-Oxide (TiNOX) coated stents is safe and effective in patients with de novo native coronary artery lesions. In the TiNOX trial there was a reduction in restenosis and major adverse cardiac events as compared with stainless steel stents of otherwise identical design. The purpose of the present study was to evaluate the long-term outcome of these patients over five years.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: Restenosis has been the principal limitation of bare metal stents. Based upon the presumption that platelet and inflammatory cell recruitment initiate neointimal proliferation, we explored a novel polymer coating that reduces cell-stent interactions. The purpose of the present study was to investigate the effect of poly(L-lysine)-graft-poly(ethyleneglycol) (PLL-g-PEG) adsorbed to stent surfaces to reduce neointimal hyperplasia in the porcine restenosis model. METHODS AND RESULTS: Seven animals were instrumented each with 2 stainless steel stents (15 mm length, 2.5-3.5 mm diameter), randomly implanted in 1 major epicardial coronary artery. One stent was dip-coated with PLL-g-PEG, whereas the other stent served as the uncoated control stent. All animals were sacrificed after 6 weeks for histological examination. Neointimal hyperplasia was significantly less (-51%) in the PLL-g-PEG-coated stents (1.15 +/- 0.59 mm2) than in the uncoated control stents (2.33 +/- 1.01 mm2; p < 0.001). Conversely, lumen size was larger in the PLL-g-PEG-coated stents (2.91 +/- 1.17 mm2) than in the uncoated stents (2.04 +/- 0.64 mm2; p < 0.001). High magnification histomorphologic examination revealed no signs of inflammation or thrombus formation in either stent group. CONCLUSIONS: Polymeric steric stabilization of stents with PLL-g-PEG significantly reduces neointimal hyperplasia in the porcine restenosis model. Reduction of cell-stent interactions mediated by PLL-g-PEG appear to improve biocompatibility of stainless steel stents without evidence of adverse inflammatory or prothrombotic effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Limited experience with bioprosthetic venous valve percutaneously inserted into femoral veins in 15 patients has been promising in short-term results only to show disappointing long-term results. Percutaneous autogenous venous valve (PAVV) transplantation was explored in an ovine model as a possible alternative treatment. METHODS: PAVV consisted of a vein segment containing a valve that was attached to a stent template. The stent templates (n = 9) were designed and hand made in our research laboratory. They consist of two stainless steel square stents 13 or 15 mm in diameter to fit the ovine jugular veins (JV), which ranges from 10 to 15 mm in diameter. A valve-containing segment of JV was harvested and attached with sutures and barbs inside the stent template (n = 9). The valve devices were then manually folded and front loaded inside the 4 cm chamber of the 13F delivery sheath and delivered into the contralateral JV by femoral vein approach. Transplanted PAVVs were studied by immediate and 3 months venograms. Animals were euthanized at 3 months, and jugular veins harvested to perform angioscopic evaluations in vitro. RESULTS: PAVV transplantation was successful in all nine animals. Good valve function with no reflux was observed on immediate and 3 months venograms in eight valves. The transplanted maximal JV diameter ranged from 10.2 mm to 15.4 mm (mean 13.1 +/- 1.5 mm). Venoscopic examination revealed intact, flexible, nonthickened valve leaflets in eight specimens. One PAVV exhibited normal function of one leaflet only; the other cusp was accidentally cut during the transplantation procedure. All transplanted autologous valves were free of thrombus and incorporated into the vein wall of the host vessel. CONCLUSION: This study demonstrated that autogenous valve transplants remained patent and competent without long-term anticoagulation for up to 3 months. The percutaneous autogenous venous valve may provide in future minimally invasive treatment for patients with chronic deep venous insufficiency, but long-term studies need to be done to document its continued patency and function.