996 resultados para Soluble fiber


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An etched long-period grating was used as a refractive index sensor for vapours of four volatile organic compounds, i.e. m-xylene, cyclohexane, trichloroethylene and commercial gasoline. The sensitivity to the vapours was further increased by solid-phase microextraction into a coating made of polydimethylsiloxane (PDMS)/polymethyl-octylsiloxane (PMOS) co-polymer. By further amplification of the optical loss in an optical cavity made of two identical fiber-Bragg gratings and interrogation by phase-shift cavity ring-down spectroscopy we could detect and distinguish xylene (detection limit: 134ppm) from trichloroethylene (3300ppm), cyclohexane (1850ppm) and gasoline (10,500ppm).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mach-Zehnder and Michelson interferometers using core-offset attenuators were demonstrated. As the relative offset direction of the two attenuators in the Mach-Zehnder interferometer can significantly affect the extinction ratio of the interference pattern, single core-offset attenuator-based sensors appear more robust and repeatable. A novel fiber Michelson interferometer refractive index (RI) sensor was subsequently realized by a single core-offset attenuator and a layer of ~ 500-nm gold coating. The device had a minimum insertion loss of 0.01 dB and maximum extinction ratio over 9 dB. The sensitivity (0.333 nm) of the new sensor to its surrounding RI change (0.01) was found to be comparable to that (0.252 nm) of an identical long period gratings pair Mach-Zehnder interferometric sensor, and its ease of fabrication makes it a low-cost alternative to existing sensing applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An overview on high-resolution and fast interrogation of optical-fiber sensors relying on laser reflection spectroscopy is given. Fiber Bragg-gratings (FBGs) and FBG resonators built in fibers of different types are used for strain, temperature and acceleration measurements using heterodyne-detection and optical frequency-locking techniques. Silica fiber-ring cavities are used for chemical sensing based on evanescent-wave spectroscopy. Various arrangements for signal recovery and noise reduction, as an extension of most typical spectroscopic techniques, are illustrated and results on detection performances are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visible and near-infrared laser light pulses were coupled into two different types of optical fiber cavities. One cavity consisted of a short strand of fiber waveguide that contained two identical fiber Bragg gratings. Another cavity was made using a loop of optical fiber. In either cavity ∼ 40 ps laser pulses, which were generated using a custom-built gainswitched diode laser, circulated for a large number of round trips. The optical loss of either cavity was determined from the ring-down times. Cavity ring-down spectroscopy was performed on 200 pL volumes of liquid samples that were injected into the cavities using a 100 μm gap in the fiber loop. A detection limit of 20 ppm of methylene blue dye in aqueous solution, corresponding to a minimum absorptivity of εC < 6 cm−1, was realized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To examine the association between dietary glycemic index (GI), glycemic load (GL), total carbohydrate, sugars, starch, and fiber intakes and the risk of reflux esophagitis, Barrett’s esophagus, and esophageal adenocarcinoma.

Methods: In an all-Ireland study, dietary information was collected from patients with esophageal adenocarcinoma (n = 224), long-segment Barrett’s esophagus (n = 220), reflux esophagitis (n = 219), and population-based controls (n = 256). Multiple logistic regression analysis examined the association between dietary variables and disease risk by tertiles of intake and as continuous variables, while adjusting for potential confounders.

Results: Reflux esophagitis risk was positively associated with starch intake and negatively associated with sugar intake. Barrett’s esophagus risk was significantly reduced in people in the highest versus the lowest tertile of fiber intake (OR 0.44 95%CI 0.25–0.80). Fiber intake was also associated with a reduced risk of esophageal adenocarcinoma, as was total carbohydrate intake (OR 0.45 95%CI 0.33–0.61 per 50 g/d increase). However, an increased esophageal adenocarcinoma risk was detected per 10 unit increase in GI intake (OR 1.42 95%CI 1.07–1.89).

Conclusions: Our findings suggest that fiber intake is inversely associated with Barrett’s esophagus and esophageal adenocarcinoma risk. Esophageal adenocarcinoma risk is inversely associated with total carbohydrate consumption but positively associated with high GI intakes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The association fiber tracts integrity of the inter-hemispheric and within-hemispheric communication was poor understood in amnestic type mild cognitive impairment (aMCI) patients by diffusion tensor imaging (DTI). A region of interest-based DTI approach was applied to explore fiber tract differences between 22 aMCI patients and 22 well-matched normal aging. Correlations were also sought between fractional anisotropy (FA) values and the cognitive performance scores in the aMCI patients. Extensive impairment of association fiber tracts integrity was observed in aMCI patients, including bilateral inferior fronto-occipital fascicles, the genu of corpus callosum, bilateral cingulate bundles and bilateral superior longitudinal fascicles II (SLE II) subcomponent. In addition, the FA value of right SLE II was significantly negatively correlated to the performance of Trail Making Test A and B, whilst the values of right posterior cingulate bundle was significantly positive correlation with MMSE score. As aMCI is a putative prodromal syndrome to Alzheimer's disease (AD), this study suggested that investigation of association fiber tracts between remote cortexes may yield important new data to predict whether a patient will eventually develop AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, new solutions to the problem of making measurements, of carbonation and chloride ingress, in particular, in concrete structures are considered. The approach has focused on the design, development, and use of fiber-optic sensors (FOSs), recognizing the need in that conventional devices are often either inaccurate, expensive, or unsuitable for encapsulation in the material. The sensors have been designed to monitor, in situ and nondestructively, relevant physical, and chemical changes in cementitious materials. Three different types of FOS were constructed, tested, and evaluated specifically for this application, these being a temperature sensor (based on the fluorescence decay) and pH and chloride sensors, based on sol-gel (solidified gel) technology with appropriate impregnated indicators. The sensors were all designed to be inserted into the structures and evaluated under the harshest conditions, i.e., being mounted when the mortar is poured and thus tested in situ, with the temperature and pH sensors successfully embedded in mortar. The outcomes of these tests have shown that both the temperature sensor and the pH sensor were able to function correctly for the duration of the work - for over 18 months after placement. The laboratory tests on the chloride sensor showed it was able to make measurements but was not reversible, limiting its potential utility for in situ environments. Research is ongoing to refine the sensor performance and extend the testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aim: Aberrant angiogenesis and defective epithelial repair are key features of idiopathic pulmonary fibrosis (IPF). Endostatin is an antiangiogenic peptide with known effects on endothelial cells. This study aimed to establish the levels of endostatin in the bronchoalveolar lavage fluid (BALF) in IPF and to investigate its actions on distal lung epithelial cells (DLEC) and primary type II cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The particle size characteristics and encapsulation efficiency of microparticles prepared using triglyceride materials and loaded with two model water-soluble drugs were evaluated. Two emulsification procedures based on o/w and w/o/w methodologies were compared to a novel spray congealing procedure. After extensive modification of both emulsification methods, encapsulation efficiencies of 13.04% tetracycline HCl and 11.27% lidocaine HCl were achievable in a Witepsol (R)-based microparticle. This compares to much improved encapsulation efficiencies close to 100% for the spray congealing method, which was shown to produce spherical particles of similar to 58 mu m. Drug release studies from a Witepsol (R) formulation loaded with lidocaine HCl showed a temperature-dependent release mechanism, which displayed diffusion-controlled kinetics at temperatures similar to 25 degrees C, but exhibited almost immediate release when triggered using temperatures close to that of skin. Therefore, such a system may find application in topical semi-solid formulations, where a temperature-induced burst release is preferred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In asthma there is increased expression of the Th2-type cytokine interleukin-4 (IL-4). IL-4 is important in immunoglobulin isotype switching to immunoglobulin E and adhesion of eosinophils to endothelium.

Objectives: We hypothesized that levels of IL-4 in bronchoalveolar lavage (BAL) fluid would be increased in stable, atopic asthmatic children compared with controls and that levels of its physiologic inhibitor IL-4 soluble receptor α (IL-4sRα) would be correspondingly decreased.

Methods: One hundred sixteen children attending a children's hospital for elective surgery were recruited. A nonbronchoscopic BAL was performed, and IL-4 and IL-4sRα were measured in the BAL supernatants.

Results: There was no significant difference in IL-4 concentrations between atopic asthmatic children, atopic normal controls, and nonatopic normal controls [0.13 pg/mL (0.13 to 0.87) vs 0.13 pg/mL (0.13 to 0.41) vs 0.13 pg/mL (0.13 to 0.5), P = 0.65]. IL-4sRα levels were significantly increased in asthmatic patients compared with atopic controls [6.4 pg/mL (5.0 to 25.5) vs 5.0 pg/mL (5.0 to 9.9), P = 0.018], but not when compared with the nonatopic controls [5.2 pg/mL (5.0 to 10.6), P = 0.19].

Conclusions: Contrary to expectation, IL-4sRα levels are increased in BAL from stable asthmatic children compared with nonatopic controls, and we speculate that IL-4sRα is released by inflammatory cells in the airways to limit the proinflammatory effects of IL-4.