993 resultados para Power Doppler ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whereas numerical modeling using finite-element methods (FEM) can provide transient temperature distribution in the component with enough accuracy, it is of the most importance the development of compact dynamic thermal models that can be used for electrothermal simulation. While in most cases single power sources are considered, here we focus on the simultaneous presence of multiple sources. The thermal model will be in the form of a thermal impedance matrix containing the thermal impedance transfer functions between two arbitrary ports. Eachindividual transfer function element ( ) is obtained from the analysis of the thermal temperature transient at node ¿ ¿ after a power step at node ¿ .¿ Different options for multiexponential transient analysis are detailed and compared. Among the options explored, small thermal models can be obtained by constrained nonlinear least squares (NLSQ) methods if the order is selected properly using validation signals. The methods are applied to the extraction of dynamic compact thermal models for a new ultrathin chip stack technology (UTCS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this brief is to present an original design methodology that permits implementing latch-up-free smart power circuits on a very simple, cost-effective technology. The basic concept used for this purpose is letting float the wells of the MOS transistors most susceptible to initiate latch-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[cat] Espanya és un dels principals mercats de productes pesquers d’Europa i del món. El consum de productes pesquers ha estat tradicionalment molt important a Espanya, el 2005 es varen consumir 36,7 kg per persona (MAPA, diversos anys). Malgrat això, el mercat i cóm interactuen els diversos nivells de la cadena de comercialització han gaudit de poca atenció. En aquest estudi, utilitzant dades setmanals, s’analitza per als dotze principals productes pesquers, l’elasticitat en la transmissió de preus al llarg de la cadena de comercialització a Espanya (llotja, mercat central i detallista). Finalment s’investiga la presència d’assimetria en la transmissió de preus entre aquests nivells de mercat. Els resultats obtinguts tenen importants implicacions a l’hora d’analitzar la demanda, poder de mercat i marges al llarg del mercat per als productes pesquers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper offers empirical evidence from Spain of a connection between the tax administration and the political power. Firstly, the regional tax administration is not immune to the budgetary situation of regional government, and tends to exert a greater (or lesser) effort in tax collection the greater (or lower) the (expected) public deficit. At the same time, the system of unconditional grants from the central layer of government provokes an ¿income effect¿ which disincentivises the efforts of the tax administration. Secondly, these efforts also decrease when the margin to lose a parliamentary seat in an electoral district is cut, although the importance of this disincentive decreases according to the parliamentary strength of the incumbent

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate prenatal diagnosis of congenital heart diseases by ultrasound investigation in well-defined European populations. DESIGN: Data from 20 registries of congenital malformations in 12 European countries were included. The prenatal ultrasound screening programs in the countries ranged from no routine screening to three ultrasound investigations per patient routinely performed. RESULTS: There were 2454 cases with congenital heart disease with an overall prenatal detection rate of 25%. Termination of pregnancy was performed in 293 cases (12%). There was considerable variation in prenatal detection rate between regions, with the lowest detection rates being in countries without ultrasound screening (11%) and in Eastern European countries (Croatia, Lithuania and Ukraine; 8%). In Western European countries with ultrasound screening, detection rate ranged from 19-48%. There was a significant difference in prenatal detection rate and proportion of induced abortions between isolated congenital heart disease and congenital heart disease associated with chromosome anomalies, multiple malformations and syndromes (P < 0.0001). There were 1694 cases with isolated congenital heart disease of which 16% were diagnosed prenatally. Malformations affecting the size of the ventricles were detected prenatally in half of the cases. CONCLUSIONS: Prenatal detection rate of congenital heart disease varies significantly between countries even with the same screening recommendations. The presence of associated malformations significantly increases the prenatal detection rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work is to study the impact of the unions' bargaining power on production and wages. We present a model where a competitive final good is produced through two substitutable intermediate goods, one produced by unskilled labor and the other by skilled labor. Potential workers decide at their cost to become skilled or unskilled and, thus, labor supplies are determined endogenously. We find that the reallocation of the labor supplies due to changes in the unskilled (or skilled) unions¿ bargaining power may have a positive impact on the final goods production. At the same time, total labor earnings increase with the unskilled unions¿ bargaining power if the final goods production increases too. We also show that the minimum wage legislation has efects similar to an increase in the bargaining power of the unskilled unions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: An elevated early (E) to late (A) diastolic filling velocities ratio, typically seen in advanced diastolic dysfunction, has also been observed after cardioversion of atrial fibrillation as a consequence of the depressed left atrial (LA) contractility. We hypothesized that the impaired LA contractile function demonstrated after orthotopic cardiac transplantation (OCT) could also lead to this "pseudorestrictive" pattern. METHOD: E/A ratio related to the tissue Doppler early mitral annular velocity (Ea) as preload-independent index of LV relaxation was evaluated in all consecutive OCT patients between 2005 and 2007. RESULTS: The study population comprised 48 patients 97 ± 77 months after OCT. Thirty-two patients (67%) had an E/A ratio > 2. LV systolic function and myocardial relaxation assessed by the Ea velocity were similar compared to patients with normal ratio (61 ± 6% vs. 60 ± 12%, P = 0.854 and 15 ± 4 cm/s vs. 14 ± 3 cm/s, r = 0.15, P = 0.323, respectively). On the other hand, the proportion of the recipient and donor LA cuffs as estimated by the recipient/global LA area ratio and the LA emptying fraction significantly correlated with the E/A ratio (r = 0.40, P = 0.005 and r =-0.33, P = 0.022, respectively). CONCLUSION: Our study shows that there is a high prevalence of elevated E/A ratio after standard OCT which seems mainly related to reduced LA contractility. Recognition of this "pseudorestrictive" pattern may avoid misdiagnosis of diastolic dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Tumour-free resection margins (RMs) are mandatory in breast-conserving surgery. On-site intraoperative ultrasound (US)-guided tumour resection with extemporaneous histopathological assessment of RMs has been described. Remote intraoperative US assessment of RMs is an alternative. The purpose of this study was to evaluate the relationship of lumpectomy RMs measurements between remote intraoperative US and postoperative histopathology.Methods and Materials: In a retrospective IRB-approved review of 100 consecutive lumpectomies performed between October 2009 and April 2011 for presumed non-palpable breast cancer, 71 women (mean age 63.8years) were included. Twenty-nine patients were excluded because of absence of cancer at histopathology and/or incomplete data. Measurements of lumpectomy minimal RMs and tumour maximal diameter obtained on remote intraoperative US and postoperative histopathology were compared.Results: Minimal RMs were 0.35±0.32 (mean±SD) and 0.35±0.32cm on remote intraoperative US and postoperative histopathology, respectively. No significant difference was found between these measurements (p=0.37). Tumour maximal diameter was 1.02±0.51 (mean±SD) and 1.33±0.74cm on remote intraoperative US and postoperative histopathology, respectively. US measurements were significantly smaller (p<0.001). The 71 breast carcinoma (CA) consisted of: invasive canalar (n=49), invasive lobular (n=11), in situ (n=3) and other types of CA (n=8). Twenty-nine patients had intraoperative re-excision (24 without residual CA), while 16 patients were re-operated due to insufficient histopathological RMs (12 without residual CA).Conclusion: Good correlation of minimal RMs between remote intraoperative US and postoperative histopathology warrants use of both techniques in a complementary manner. Remote intraoperative US is helpful in taking rapid decision of re-excision and maintaining low re-operation rate after breast-conserving surgery for non-palpable cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report on applying agreed-upon procedures to the Villisca Municipal Power Plant’s accounting procedures, cash and investment balances and compliance with Code of Iowa requirements for the period February 1, 2007 through December 31, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Deep burn assessment made by clinical evaluation has an accuracy varying between 60% and 80% and will determine if a burn injury will need tangential excision and skin grafting or if it will be able to heal spontaneously. Laser Doppler Imaging (LDI) techniques allow an improved burn depth assessment but their use is limited by the time-consuming image acquisition which may take up to 6 min per image. METHODS: To evaluate the effectiveness and reliability of a newly developed full-field LDI technology, 15 consecutive patients presenting with intermediate depth burns were assessed both clinically and by FluxExplorer LDI technology. Comparison between the two methods of assessment was carried out. RESULTS: Image acquisition was done within 6 s. FluxEXPLORER LDI technology achieved a significantly improved accuracy of burn depth assessment compared to the clinical judgement performed by board certified plastic and reconstructive surgeons (P < 0.05, 93% of correctly assessed burns injuries vs. 80% for clinical assessment). CONCLUSION: Technological improvements of LDI technology leading to a decreased image acquisition time and reliable burn depth assessment allow the routine use of such devices in the acute setting of burn care without interfering with the patient's treatment. Rapid and reliable LDI technology may assist clinicians in burn depth assessment and may limit the morbidity of burn patients through a minimization of the area of surgical debridement. Future technological improvements allowing the miniaturization of the device will further ease its clinical application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transparent conducting, aluminium doped zinc oxide thin films (ZnO:Al) were deposited by radio frequency (RF) magnetron sputtering. The RF power was varied from 60 to 350Wwhereas the substrate temperature was kept at 160 °C. The structural, electrical and optical properties of the as-deposited films were found to be influenced by the deposition power. The X-ray diffraction analysis showed that all the films have a strong preferred orientation along the [001] direction. The crystallite size was varied from 14 to 36 nm, however no significant change was observed in the case of lattice constant. The optical band gap varied in the range 3.44-3.58 eV. The lowest resistivity of 1.2×10 -3Vcm was shown by the films deposited at 250 W. The mobility of the films was found to increase with the deposition power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a method to obtain a single centered correlation with use of a joint transform correlator. We analyze the required setup to carry out the whole process optically, and we also present experimental results.