999 resultados para Plasma fluoride


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multi phase model of human blood plasma was developed and the Tb(Ⅲ) speciation in this system was studied. The results show that the speciation of Tb(Ⅲ) depends on the concentration of Tb(Ⅲ). When the concentration of Tb(Ⅲ) is below 4.000×10 -8 mol/L, most of Tb(Ⅲ) exists as soluble species while the concentration of Tb(Ⅲ) is in between 4.000 ×10 -8 mol/L and 1.667×10 -2 mol/L, precipitates(TbPO 4 and Tb 2 (CO 3 ) 3 ) are the dominant species of Tb(Ⅲ). Among soluble Tb(Ⅲ) ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complex fluoride LiBaF3 and LiBaF3:M(M = Eu, Ce) is solvothermally synthesized at 180 degreesC and characterized by means of X-ray powder diffraction, scanning electron microscopy, thermogravimetric analysis and infrared spectroscopy. In the solvothermal process, the solvents, molar ratios of initial mixtures and reaction temperature play important roles in the formation of products. The excitation and emission spectra of the LiBaF3:M(M= Eu,Ce) have been measured by fluorescence spectrophotometer. In the LiBaF3: Eu emission spectra, there is one sharp line emission located at 360 nm arising from f --> f transition of Eu2+ in the host lattice, and typical doublet 5d-4f emission of Ce3+ in LiBaF3 powder is shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cetyltrimethylammonium bromide (CTAB)/2-octanol/water microemulsion system was used to synthesize barium fluoride nanoparticles. X-ray powder diffraction (XRD) analysis showed that the products were single phase. The results of scanning electron microscopy and calculations using the Scherrer equation from the line widths of the XRD have been used to estimate the average particle sizes of the powder products. The results showed that the nanoparticle size was affected by water content and surfactant (CTAB) concentration. As water content decreases from 14.2 to 9.47% (w/w), the particle size decreases from 75 to 40 rim. In addition, increasing the reaction times from 5 to 120 min increases the particle size from 75 to 150 rim, and increasing the amount of surfactant decreases the size of the particle. Luminescence spectra of the BaF2:Ce nanoparticles are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complex fluoride alpha'-SrAlF5 has been synthesized through hydrothermal and solvothermal methods under mild conditions. The effects of the molar ratio of starting materials, temperature, reaction time and solvents on the synthesis of alpha'-SrAlF5 were discussed. The final products were characterized by XRD and SEM. The rod-like shape of alpha'-SrAlF5 is shown in SEM images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two Meinhard microconcentric nebulizers, model AR30-07-FM02 and AR 30-07-FM005, were employed as a self-installed micro-sampling system for inductively coupled plasma-mass spectrometry (ICP-MS). The FM02 nebulizer at 22 muL/min of solution uptake rate gave the relative standard deviations of 7.6%, 3.0%, 2.7%, 1.8% for determinations (n = 10) of 20 mug/L Be, Co, In and Bi, respectively, and the detection limits (3s) of 0.14, 0.10, 0.02 and 0.01 mug/L for Be, Co In and Bi, respectively. The mass intensity of In-115 obtained by this micro-sampling system was 60% of that by conventional pneumatic nebulizer system at 1.3 mL/min. The analytical results for La, Ce, Pr and Nd in 20 muL Wistar rat amniotic fluid obtained by the present micro-sampling system were precisely in good agreement with those obtained using conventional pneumatic nebulization system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the determination of Au, Pt and Pd in geological samples is described. Au, Pt and Pd can be separated and concentrated quantitatively by C-410 anion-exchange resin in the condition of 1.5 mol/L HCl with the adsorption rates of 91.2%, 100.0% and 95.7% respectively. No interference exists from coexisting elements except for Ge(IV), Cr(VI),Ti(IV) in inductively coupled plasma-mass spectrometry. The detection limits are 0.27 mug/L, 0.40 mug/L and 0.19 mug/L for Au, Pt and Pd respectively. The results of these elements in standard geological materials are in agreement with certified values with precision of 19.2% RSD for Au (n = 8), 28.1% RSD for Pt (n=8), and 15.6% RSD for Pd (n=8).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complex fluoride LiBaF3 is solvothermally synthesized at 180degreesC and characterized by means of X-ray powder diffraction, scanning electron microscopy, thermogravimetric analysis and infrared spectroscopy. In the solvothermal process, the solvents, mole ratios of initial mixtures and reaction temperature play important roles in the growth of the single crystal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effect of Tb3+ on Ca2+ speciation in human plasma was studied by means of the computer program of MINTEQA2. When Tb3+ ions are not added into the system, Ca2+ ions mostly distribute in free Ca2+ (74.7%) and the surplus distributes in Ca2+ complexes, such as [CaHCO3](+) (7.9%),[Ca(Lac)](+) (6.4%), CaHPO4 (1.3%), [CaHistidinateThreoninateH(3)](3+) (2.4%), [CaCitrateHistidinateH(2)] (2.3%) and CaCO3 (1.1%). Tb3+ can compete with Ca2+ for inorganic as well as biological ligands. An increase of concentration of Tb3+ in the system results in an increase of content of free Ca2+ and a decrease of contents of Ca2+ complexes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix effects in now injection (FI) inductively coupled plasma mass spectrometry has been studied,and the results have been compared with those of continuous nebulization. The matrix element As and nu with higher ionization potential ( > 9eV) have enhancement effect on the analyte signal,and the heavier the analyte mass, the smaller the enhancement effects by Fl. The matrix elements Cu, In, Li, Na and Pb with lower ionization potential have suppression effect on the analyte signal. The heavier the matrix element mass, the more severe the suppression effects. The heavier the analyte mass, the smaller the suppression effects. The higher ionization potential of analyte, the more severe the suppression effects. Compared with continuous nebulization, the degree of suppression effect is smaller and the degree of the enhancement effect is larger by Fl.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanometre-sized poly(vinylidene fluoride) (PVDF) particle domains in a confined space were obtained by blending PVDF with excess poly(methyl methacrylate) (PMMA). When these particles were small enough they showed beta -form structure, which was different from the structure of bigger particles or PVDF bulk. However, the beta -form was thermodynamically metastable because it could eventually be transformed to a more stable phase by annealing at a certain temperature. Larger particle domains were of identical phase to the bulk, indicating that small size favours the formation of the beta -form. (C) 2000 Society of Chemical Industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Excitation and emission characteristics were reviewed for phosphors which were reported, applied, or suggested for the plasma display panel (PDP). Correlation of luminescence characteristics to the host crystal structure and the activator of the phosphor was explained. Improvements of the PDP phosphor for practicality were considered. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of swelling and stripping acidity on the mass transfer coefficient based on water phase and the inner diameters of membranes were studied with P507-HCl-Sm as working system in the two different kinds of hollow fiber membranes. Effects of extractant concentration, H+ concentration in aqueous phase and Sm3+ concentration on extraction rate were discussed and the corresponding reaction series were obtained. According to the investigations on the interfacial kinetics, the reaction kinetics equation and reaction rate constant were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix effects arising from ethanol, propanol, glycerol, acetic acid, ethylenediamine and triethanolamine in inductively coupled plasma mass spectrometry have been studied. Addition of ethanol, propanol, glycerol, acetic acid, ethylenediamine and triethanolamine into solution has an enhancement effect on the signal intensity of analyte with ionization potential between 9 and 11 eV. The ethylenediamine and triethanolamine have higher enhancement effect on the signal intensity of Hg than that of ethanol, propanol, glycerol and acetic acid. Addition of ethylenediamine and triethanolamine into solution has a suppression effect on the signal intensity of Ph and Sr. The mechanism of the enhancement or suppression was investigated. The signal enhancement of Hg in the presence of ethylenediamine and triethanolamine is not caused by improved degree of ionization of Hg and nebulization efficiency. The suppression effects of Ph and Sr in the presence of ethylenediamine and triethanolamine are due to decrease of atomization efficiency of these elements. A method for the determination of Hg in the biological standard samples Ly ICP-MS was developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inductively coupled plasma mass spectrometry (ICP-MS),a highly sensitive inorgnic analytic technique,fits to determine ultra-nace rare-earth elements in human plasma. Under the optimized conditions detection limits for 15 rare-earth elements are in the range of 0.7 (for Eu)-5.4 (for Gd) ng.L-1. Indium as an internal standard element is used to compensate for matrix suppression effect and sensitivity drift. Three kinds of preparation methods, diluted with 1% HNO3, digested with HNO3-H2O2 and with HNO3-HClO4, are checked and compared,and the former is the simplest way to be measured. The samples diluted with 1% HNO3, stored in 4 degrees C, are very steady for 16 days. With the method, 11 healthy plasma samples in Changchun area of China are analysed.