978 resultados para Minimal Inhibitory Concentration (MIC)
Resumo:
Transthyretin amyloidosis is a conformational pathology characterized by the extracellular formation of amyloid deposits and the progressive impairment of the peripheral nervous system. Point mutations in this tetrameric plasma protein decrease its stability and are linked to disease onset and progression. Since non-mutated transthyretin also forms amyloid in systemic senile amyloidosis and some mutation bearers are asymptomatic throughout their lives, non-genetic factors must also be involved in transthyretin amyloidosis. We discovered, using a differential proteomics approach, that extracellular chaperones such as fibrinogen, clusterin, haptoglobin, alpha-1-anti-trypsin and 2-macroglobulin are overrepresented in transthyretin amyloidosis. Our data shows that a complex network of extracellular chaperones are over represented in human plasma and we speculate that they act synergistically to cope with amyloid prone proteins. Proteostasis may thus be as important as point mutations in transthyretin amyloidosis.
Resumo:
The osmotic threshold for vasopressin release was studied in normal patients (n = 7) and in patients with the chronic form of Chagas'disease (n = 11). Positive correlation between osmotic threshold and plasma cortisol concentration was obtained for the Controls (y1 = 273,30 + 0,75x i; r = 0,78;P < 0,05), suggesting a modulating effect of cortisol on vasopressin release. The lack of correlation between the two parameters for the chronic chagasic patients was interpreted, on the basis of the general denervation associated with Chagas ' disease, to be the result of neuronal destruction in hypothalamic and/or extrahypothalamic centers related to the secretory control of vasopressin.
Resumo:
RESUMO: A Diabetes Mellitus é uma doença metabólica crónica, com deficiência a nível do metabolismo dos hidratos de carbono, lípidos e proteínas, resultante de deficiências na secreção ou ação da insulina, ou de ambas, que quando não tratada antecipadamente e de modo conveniente, pode ter consequências muito graves. Dado a incidência a nível mundial da Diabetes Mellitus, torna-se de elevada importância avaliar toda a sua envolvência e estudar bem quais os critérios a ter em consideração. Este trabalho propõe-se estudar para além dos parâmetros bioquímicos relacionados com a doença - Glicose e Hemoglobina Glicada A1c (HbA1c), analisar os resultados dos últimos cinco anos (2008-2012) dos ensaios interlaboratoriais do PNAEQ, do Departamento de Epidemiologia, do Instituto Nacional de Saúde Dr. Ricardo Jorge. Foram também analisadas as metodologias utilizadas e as variações interlaboratoriais, de forma a entender qual ou quais são os parâmetros mais adequados para o seu diagnóstico e controlo. Este estudo utilizou a população de laboratórios portugueses, públicos e privados, de Portugal Continental e Ilhas, um laboratório de Angola e outro de Macau que se inscreveram no PNAEQ nestes cinco anos, sendo a amostra composta pelo n.º de participações. No programa de Química Clinica foram distribuídas 38 amostras e no programa de HbA1c foram distribuídas 22 amostras. Para a glicose, o nível de desempenho nos ensaios é na globalidade das amostras de Excelente, no entanto verifica-se que sempre que a concentração da amostra é de nível patológico, que a maioria dos ensaios o desempenho foi inferior – Bom. O método de eleição e com CV% mais baixos foi o método da hexoquinase. Para a HbA1c, o nível de desempenho nos ensaios é na globalidade das amostras de Excelente. O método de eleição e com CV% mais baixos foi o método de HPLC. O CV% para a glicose ronda desde 2010 a 2012, os 3% e para a HbA1c foi de aproximadamente 4,0% em 2012. A HbA1c tem mostrado ser uma ferramenta muito útil, importante e robusta na monitorização da Diabetes, sendo hoje em dia quase sempre requisitada em análises de rotina a diabéticos de modo a prevenir complicações que possam vir a acorrer. No futuro poderá ser um importante, senão o parâmetro de futuro, para o diagnóstico da Diabetes, no entanto, mesmo já tendo sido muito trabalhada a sua padronização, ainda existem questões por responder como quais são na realidade todos os seus interferentes, qual a verdadeira relação da HbA1c com a glicose média estimada, em todas as populações e com estudos epidemiológicos. Também a própria educação do diabético e clínico deve ser aprimorada, pelo que neste momento as PTGO e os doseamentos de glicose em jejum devem ser utilizados e encontrando-se a Norma da DGS N.º 033/2011 de acordo com as necessidades e com o estado da arte deste parâmetro. A implementação da glicose média estimada será uma mais-valia na monitorização dos diabéticos pelo que deverá ser uma das prioridades a ter em conta no futuro desta padronização, uniformizando a decisão clinica baseada nela e minimizando a dificuldade de interpretação de resultados de laboratório para laboratório. --------------ABSTRACT: Diabetes Mellitus is a chronic metabolic disease, with a deficit in the metabolism of carbohydrates, lipids and proteins, resulting from deficiencies in insulin secretion or action, or both, which if, when not early treated in a proper way, may result in very serious consequences. Given the worldwide incidence of diabetes mellitus, it is highly important to evaluate all its background and study specifically all the criteria to take into consideration. The aim of this thesis is to study and evaluate beyond the biochemical parameters related to the disease - Glucose and Glycated Haemoglobin A1c (HbA1c), analyze the results of the last five years (2008-2012) of the PNAEQ interlaboratorial tests, in the Department of Epidemiology of National Institute of Health Dr. Ricardo Jorge. It is also intended to analyze the methodologies used and the interlaboratorial variations, in order to understand the most suitable parameters for the diagnosis and control. This study was based in a population of Portuguese laboratories, public and private, of Portugal mainland and islands, a laboratory of Angola and other from Macau, who enrolled in PNAEQ in these five years, and the sample was composed by the n. º of holdings. In the Clinical Chemistry Program there were distributed 38 samples and in the program HbA1c were distributed 22 samples. For glucose, the level of performance in the total nº of the samples was Excellent; however, it was found that when the concentration level of the sample was pathological, in most of the tests the performance was Good. The most preferred method with the lowest CV% is the hexokinase method. For the HbA1c, as a whole, the samples’ tests were Excellent, at the level of performance. The method of election with the lower CV% was the HPLC. The CV% for glucose was around 3%, from 2010 to 2012 and the HbA1c was approximately 4.0% in 2012. The HbA1c method has demonstrated to be a very useful tool, important and robust for monitoring diabetes, being nowadays, almost always required in routine analysis to prevent future complications. In the future it may be an important parameter, if not the most important, for the diagnosis of diabetes. However, despite it has already been standardized, there are still some questions that need to be answered, such as, which are in fact all their interferences, which is the true connection of HbA1c, when compared with the estimated average glucose, in all populations and epidemiological studies. Moreover, the education of the patient and the doctor concerning diabetes should be improved. Nowadays, the Oral Glucose Tolerance Test (OGTT) and fasting glucose determinations should be used and, the needs and the state of the art of this parameter, should be in accordance with the Standard DGS N. º 033/2011. The Implementation of the estimated average glucose will be an added value in monitoring diabetics and, therefore, should be a priority to consider in its future standardization and clinical decision based on it, will be uniform and the difficulty of interpreting results from laboratory to laboratory will be minimal.
Resumo:
Dissertação para obtenção do Grau de Doutor em Química Sustentável
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Física
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia do Ambiente
Resumo:
Double Degree. A Work Project, presented as part of the requirements for the Award of a Master’s Degree in Finance from NOVA – School of Business and Economics and a Masters Degree in Management from Louvain School of Management
Resumo:
IntroductionThe effects of piperonyl butoxide (PBO) on the toxicity of the organophosphate temephos (TE) and the role of esterases in the resistance of Aedes aegypti to this insecticide were evaluated.MethodsA. aegypti L4 larvae susceptible and resistant to TE were pre-treated with PBO solutions in acetone at concentrations of 0.125, 0.25, 0.5, 1, and 2% for 24h and subsequently exposed to a diagnostic concentration of 0.02mg/L aqueous TE solution. The esterase activity of the larvae extracts pre-treated with varying PBO concentrations and exposed to TE for three time periods was determined.ResultsAt concentrations of 0.25, 0.5, 1, and 2%, PBO showed a significant synergistic effect with TE toxicity. High levels of esterase activity were associated with the survival of A. aegypti L4 larvae exposed to TE only.ConclusionsThe results of the biochemical assays suggest that PBO has a significant inhibitory effect on the total esterase activity in A. aegypti larvae.
Resumo:
ABSTRACTINTRODUCTION:Exposure to subinhibitory concentrations (SICs) of antimicrobials may alter the bacterial transcriptome.METHODS: Here, we evaluated the expression of nine virulence-related genes in vancomycin-resistant enterococci (VRE) urinary tract infection isolates grown at SICs of vancomycin.RESULTS:A Subinhibitory concentrations of vancomycin interferes with gene modulation, but does not affect the phenotype of a VRE strain in vitro .CONCLUSIONS:Subinhibitory concentrations of vancomycin may regulate the expression of virulence factors in vivo or contribute to the selection of vancomycin-resistant strains.
Resumo:
Fluid management and dosage regimens of drugs in preterm infants should be based on the glomerular filtration rate. The current methods to determine glomerular flitration rate are invasive, time-consuming, and expensive. In contrast, creatinine clearance can be easy obtained and quickly determined. The purpose of this study was to compare plasma creatinine on the third and seventh day of life in preterm newborn infants, to evaluate the influence of maternal creatinine, and to demonstrate creatinine clearance can be used as a reliable indicator of glomerular filtration rate. We developed a prospective study (1994) including 40 preterm newborns (gestational age < 37 weeks), average = 34 weeks; birth weight (average) = 1840 g, in the first week of life. Inclusion criteria consisted of: absence of renal and urinary tract anomalies; O2 saturation 3 92%; adequate urine output (>1ml/kg/hr); normal blood pressure; absence of infections and no sympathomimetic amines in use. A blood sample was collected to determine plasma creatinine (enzymatic method) on the third and seventh day of life and creatinine clearance (CrCl) was obtained using the following equation: , k = 0.33 in preterm infant All plasma creatinine determinations showed normal values [third day: 0.78 mg/dl ± 0.24 (mean ± SD)and seventh day: 0.67 mg/dl ± 0.31 - (p>0.05)]. Also all creatinine clearance at third and seventh day of life were normal [third day: 19.5 ml/min ± 5.2 (mean ± SD) and seventh day: 23.8 ml/min ± 7.3 - (p>0,05)]. All preterm infants developed adequate renal function for their respective gestational age. In summary, our results indicate that, for clinical practice, the creatinine clearance, using newborn length, can be used to estimate glomerular filtration rate in preterm newborn infants.
Resumo:
Evaluation of Cyclosporin A (CyA) blood concentration is imperative in solid organ transplantation in order to achieve maximal immunosuppression with the least side effects. We compared the results of whole blood concentrations of CyA in 50 blood samples simultaneously evaluated by the fluorescent polarization immune assay (TDx) and the enzymatic competitive immune assay (EMIT 2000). There was a strong correlation between both kits for any range of CyA blood concentration (R=0.99, p<0.001). The within-run and between-days coefficient of variation were less than 4% for both assays. The cost for each CyA measurement was 50% lower for the EMIT assay when compared to the TDx assay. We concluded that the EMIT is as accurate as the TDx in measuring CyA blood concentration and has the advantage of a lower cost, as well as the possibility of widespread access to the EMIT methodology in contrast to the TDx equipment, allowing the laboratory to perform several routines within a working day.
Resumo:
The Peutz-Jeghers syndrome is a hereditary disease that requires frequent endoscopic and surgical intervention, leading to secondary complications such as short bowel syndrome. CASE REPORT: This paper reports on a 15-year-old male patient with a family history of the disease, who underwent surgery for treatment of an intestinal occlusion due to a small intestine intussusception. DISCUSSION: An intra-operative fiberscopic procedure was included for the detection and treatment of numerous polyps distributed along the small intestine. Enterotomy was performed to treat only the larger polyps, therefore limiting the intestinal resection to smaller segments. The postoperative follow-up was uneventful. CONCLUSION: We point out the importance of conservative treatment for patients with this syndrome, especially those who will undergo repeated surgical interventions because of clinical manifestation while they are still young.
Resumo:
In the early nineties, Mark Weiser wrote a series of seminal papers that introduced the concept of Ubiquitous Computing. According to Weiser, computers require too much attention from the user, drawing his focus from the tasks at hand. Instead of being the centre of attention, computers should be so natural that they would vanish into the human environment. Computers become not only truly pervasive but also effectively invisible and unobtrusive to the user. This requires not only for smaller, cheaper and low power consumption computers, but also for equally convenient display solutions that can be harmoniously integrated into our surroundings. With the advent of Printed Electronics, new ways to link the physical and the digital worlds became available. By combining common printing techniques such as inkjet printing with electro-optical functional inks, it is starting to be possible not only to mass-produce extremely thin, flexible and cost effective electronic circuits but also to introduce electronic functionalities into products where it was previously unavailable. Indeed, Printed Electronics is enabling the creation of novel sensing and display elements for interactive devices, free of form factor. At the same time, the rise in the availability and affordability of digital fabrication technologies, namely of 3D printers, to the average consumer is fostering a new industrial (digital) revolution and the democratisation of innovation. Nowadays, end-users are already able to custom design and manufacture on demand their own physical products, according to their own needs. In the future, they will be able to fabricate interactive digital devices with user-specific form and functionality from the comfort of their homes. This thesis explores how task-specific, low computation, interactive devices capable of presenting dynamic visual information can be created using Printed Electronics technologies, whilst following an approach based on the ideals behind Personal Fabrication. Focus is given on the use of printed electrochromic displays as a medium for delivering dynamic digital information. According to the architecture of the displays, several approaches are highlighted and categorised. Furthermore, a pictorial computation model based on extended cellular automata principles is used to programme dynamic simulation models into matrix-based electrochromic displays. Envisaged applications include the modelling of physical, chemical, biological, and environmental phenomena.
Resumo:
Cystic fibrosis is a genetic disease usually diagnosed by abnormal sweat testing. We report a case of an 18-year-old female with bronchiectasis, chronic P. aeruginosa infection, and normal sweat chloride concentrations who experienced rapid decrease of lung function and clinical deterioration despite treatment. Given the high suspicion ofcystic fibrosis, broad genotyping testing was performed, showing a compound heterozygous with deltaF508 and 3849+10kb C->T mutations, therefore confirming cystic fibrosis diagnosis. Although the sweat chloride test remains the gold standard for the diagnosis of cystic fibrosis, alternative diagnostic tests such as genotyping and electrophysiologic measurements must be performed if there is suspicion of cystic fibrosis, despite normal or borderline sweat chloride levels.