998 resultados para Ligas de titanio - Propriedades mecanicas


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nos últimos anos tem havido um considerável aumento do número de ligas acadêmicas atuantes nos cursos de graduação em medicina no Brasil. Esse fenômeno, no entanto, não vem sendo acompanhado de adequada reflexão sobre seus determinantes, o papel das ligas dentro das instituições, ou mesmo sua função pedagógica. A partir destas constatações, os autores analisam a precária literatura sobre o tema, descrevem a experiência das ligas acadêmicas da Faculdade de Medicina de Botucatu - Unesp e refletem a respeito do papel destas na formação médica, na tentativa de suprir um pouco dessa lacuna e contribuir para esta importante discussão.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this work was to assess the effects of soil preparation methods (with or without subsoiling) on physical properties of a cerrado soil cropped to corn during the, 1986/87 season, in the Selviria county (Mato Grosso do Sul, Brazil). Also, the objective of this was to check the changes in the soil (dark red latosol-Acrustox) caused by the preparation after nine years of cultivation in comparison with natural state. The experiment consisted of six soil preparation systems: conventional, superpreparation, reversed, revolving hoe, reduced and no-tillage. Along with these systems subsoiling was also tested. The reversed system showed the best com grain yield. Subsoiling only presented positive results in productivity with the no-tillage system. All the preparation system tested degraded the physical properties in comparison with the natural soil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work it was studied the capacity of cellulose and chemically modified celluloses (carboxymethylcellulose, cellulose phosphate and oxicellulose) to adsorb copper(II) cations of aqueous and non aqueous solutions. The influence of the principal physical chemical parameters on the adsorption process was examined using the batch adsorption method and copper(II) perchlorate solutions, the maximum adsorption capacity determined for adsorbents were as follows (mol.g(-1)): cellulose, 0.54 . 10(-5); carboxymethylcellulose, 1.28 . 10(-4); cellulose phosphate, 1.12 . 10(-4); oxicellulose, 0.38 . 10(-4).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Caiua Sandstones, sedimentary Cretaceous rocks, have a grain specific gravity nearly that of quartz, its main mineralogical component. The remaining properties, such as the apparent dry density, apparent and effective porosity, water absorption and saturation voids, present high values, but decrease with depth. -from English summary

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors studied the CREEP of 5 amalgam alloys (1 conventional and 4 with high cooper) by the application os static load of 36 MPa in 478 mm specimens, 7 days old. After CREEP test, the samples were included in acrylic resin and Vickers hardness determined by three penetrations for each portion (cervical, medium and occlusal). Samples not submitted to the creep test was used with control. They concluded that no statistic difference was found in creep test but in Vickers test all the studied materials showed different hardness averages. The load application to samples increased the hardness of all the studied materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

They were casted pieces using three kinds of alloy (Ni-Cr, Ag-Sn and Cu-Al) with circular and smooth surface. They were cemented to human teeth, on occlusal surface, grounded at dentin level, through three different materials kind (zinc polycarboxylate cement, glassionomer cement and composite). After 24 hours storing, the samples were subjected to the tensile test. The results showed that the samples cemented with composite and the casts made with Ag-Sn alloy had higher bond strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Being the surface roughness a fundamental property in the fit of the castings, it was determined the roughness of 5 high-copper casting alloys, according to the heating over their melting temperature. That way, the specimens made with smooth plastic in the shape of a rectangular plate, 2 mm x 7 mm x 11 mm were invested into a cristobalite investment. After heating and elimination on the plastic, the molds were filled by 3 g of molten alloy, casted in a electrical casting machine at the casting temperature at 25 degrees C and 50 degrees C overheating. The surface roughness was measured in a roughness analyser, Talysurf. As a result, it was verified that there is a variation of surface roughness among the alloys tested, and the heating of the alloys until 50 degrees C over the melting temperature does not interfere in the roughness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was evaluated the castability of four copper-aluminium alloy according the melting casting method used. The specimens were made using polyester mesh screen, with 11 x 11 filaments of 0.26 mm thick, fixed along of two adjacent edges in wax bar, with the sprue attached at their junction. The alloys were in an electrical casting machine and a centrifugal casting machine with an air/gas torch. The castability values were obtained by the percentage of completed segments of the resulting cast alloy screen. It was verified that the use of the electrical casting machine produced higher castability values to the copper-aluminium alloys than those produced by a centrifugal casting machine with an air/gas torch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was evaluated the Vickers hardness of five high-copper casting alloys, in their original package form and after casting, according to the casting method used. That way, ten ingots, supplied by the manufacturers of each alloy, were included in self-curing acrylic resin, polished, numerated and submitted to Vickers hardness test at load of 200 g during 30 seconds. Afterwards the numerated ingots were removed from the acrylic resin and five of those were cast in an electrical casting machine and the other five in a centrifugal casting machine with an air/gas torch. The specimens obtained were included in self-curing acrylic resin, polished and submitted to Vickers hardness test. As a result it was verified that there is a variation of hardness among the alloys tested, and the use of the electrical casting machine produced lower hardness values than those produced when used the centrifugal casting machine with an air/gas torch. Also, there is a decrease of hardness of the cast alloys when they are tested in their original form and after casting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare the enamel/resin/metal bond tensile strength by using human canines, in which castings were bonded. These castings were obtained by Co-Cr or Ni-Cr alloys and showed four types of mechanisms of retention: 50 micrograms aluminum oxide abrasive, electrochemical etch, acrylic beads metal mesh. The castings were bonded utilizing Comspan Opaque and Panavia Ex. The specimens were subjected to tensile forces after 24 hours in an Instron machine. The castings subjected to 50 micrograms aluminum oxide abrasive and bonded utilizing Panavia EX showed the biggest bond tensile strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors tested the T clasp of Roach in three differents proportions among width and thickness: E1-1.7; E2-2.0 and E3-2.3, with a constant length of 15 mm. These clasps were casted with three cobalt-chromium alloys (L1-Biosil; L2-Steldent and L3-Duracrom), through two casting techniques (F1-oxygen-gas and F2-oxygen-acetylene). The fatigue of the clasps were verified by using and assay machine, that through movements, simulate the insertion and removal of the clasps for a pattern which were obtained from a premolar, prepared in a surveyor. This machine detect the fatigue of the clasps and count the number of cycles of insertion and removal realized. The obtained results of the interaction between the analysed factors, were submitted to the statistic analysis and the authors concluded that: a) the interaction of factors, Alloy x Thickness, Alloy x Casting Technique and Thickness x Casting Technique did not change the order of effects that the factors showed separately but gave rise to effects of different magnitude for any observed sense; b) the simultaneous interaction of the factors Alloy x Thickness x Casting Technique confirmed the superiority of the L3 alloy, the thickness E3 and the F2 casting technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the study presented in this article was to analyze the influence of remelting of two odontological alloys: Dentorium and Steeldent, on the mechanical properties and on the chemical composition. For the two alloys, samples, containing 10% and 50% new alloy, were subjected to tensile test, micrography and chemical analysis. The alloys presented similar mechanical properties, except for the elongation, which presented higher values for the Dentorium 50% new alloy. This is due to the smaller carbides formed in this sample. The remelting itself seems not to be responsible for these differences, but they are probably due to the lack of a good control of the casting process. The micrography showed a dendritic column matrix, with carbides in the interdentric region and inside dendritic grain. In the chemical composition was observed few elements percentage change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was designed to separately evaluate the analgesic capacity of 15% tea from Achillea millefolium leaves and florid ends. Three different tests were performed. The animals were separated in 3 groups: group I (control) that received water, group II that received florid end tea, and group III that received leaf tea. The first test was the writhing test induced by intraperitoneal injection of acetic acid in male Swiss mice. The second test consisted of the measurement of tail flick reflex latency (TFRL) in male Wistar rats after receiving a painful thermal stimulus. The groups received the teas or water per os, prior to observation. In the third test, the Wistar rats were submitted to an approximately 1 cm long incision in their tails to test the effect of the teas on induced inflammatory pain. The results showed that the effect of the 15% leaf tea on the mice writhing and TFRL test were not statistically significant. The florid ends tea showed a significantly increase in number of writhes in mice and TFRL in rats after administration. With regard to the effect of the teas on inflammatory pain, ingestion of both preparations caused an increase in the force threshold necessary for the avoidance reflex, indicating antihyperalgesic action of both the leaf and florid ends 15% teas of Achillea millefolium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper supplies a compact revision on the herbicide glyphosate physic-chemistry characteristic mains, including toxicity and valid Brazilian legislation for its use.