Influência do escoamento estático (CREEP) na dureza do amálgama. Efeito de ligas e regióes de medida.


Autoria(s): Glavan, P. R.; da Silva Filho, F. P.; de Sa, D. N.; Rettondini, W. C.; Ababo, G. L.; dos Santos Cruz, C. A.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

27/05/2014

27/05/2014

01/05/1990

Resumo

The authors studied the CREEP of 5 amalgam alloys (1 conventional and 4 with high cooper) by the application os static load of 36 MPa in 478 mm specimens, 7 days old. After CREEP test, the samples were included in acrylic resin and Vickers hardness determined by three penetrations for each portion (cervical, medium and occlusal). Samples not submitted to the creep test was used with control. They concluded that no statistic difference was found in creep test but in Vickers test all the studied materials showed different hardness averages. The load application to samples increased the hardness of all the studied materials.

Formato

207-210

Identificador

RGO, v. 38, n. 3, p. 207-210, 1990.

0103-6971

http://hdl.handle.net/11449/63984

2-s2.0-0025424097

Idioma(s)

por

Relação

RGO

Direitos

closedAccess

Palavras-Chave #dental alloy #chemistry #flow kinetics #hardness #materials testing #Dental Amalgam #English Abstract #Hardness #Hardness Tests #Materials Testing #Rheology