994 resultados para LIQUID-DROP SENSOR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel sensing technique for the in situ monitoring of the rate of pulsed laser deposition (PLD) of metal thin films has been developed. This optical fibre based sensor works on the principle of the evanescent wave penetration of waveguide modes into the uncladded portion of a multimode fibre. The utility of this optical fibre sensor is demonstrated in the case of PLD of silver thin films obtained by a Q-switched Nd:YAG laser which is used to irradiate a silver target at the required conditions for the preparation of thin films. This paper describes the performance and characteristics of the sensor and shows how the device can be used as an effective tool for the monitoring of the deposition rate of silver thin films. The fibre optic sensor is very simple, inexpensive and highly sensitive compared with existing techniques for thin film deposition rate measurements

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel sensing technique for the in situ monitoring of the rate of pulsed laser deposition (PLD) of metal thin films has been developed. This optical fibre based sensor works on the principle of the evanescent wave penetration of waveguide modes into the uncladded portion of a multimode fibre. The utility of this optical fibre sensor is demonstrated in the case of PLD of silver thin films obtained by a Q-switched Nd:YAG laser which is used to irradiate a silver target at the required conditions for the preparation of thin films. This paper describes the performance and characteristics of the sensor and shows how the device can be used as an effective tool for the monitoring of the deposition rate of silver thin films. The fibre optic sensor is very simple, inexpensive and highly sensitive compared with existing techniques for thin film deposition rate measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fibre optic technique for detecting trace amounts of nitrite compounds in water is described. The off-line fibre optic sensor outlined here is based on evanescent field absorption in a test solution formed by the reaction of nitrite compounds in water with suitable chemical reagents. A short unclad portion of a plastic clad silica fibre acts as the sensing region. The experimental results clearly establish the usefulness of the present technique for detecting very low concentrations of the order of 1 ppb (parts per billion) of nitrite compounds with a large dynamic range of 1–1000 ppb. Such a high sensitivity enables the present device to be used for measuring the nitrite content in drinking water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication and characterization of a fibre optic pH sensor based on evanescent wave absorption is presented. The unclad portion of a multi-mode optical fibre is coated with a pH sensitive dye, which is immobilized by the sol–gel route. The sensitivity of the device has been found to increase when multiple sol–gel coatings are used as the sensing region. The dynamic range and the temporal response of the sensor are investigated for two different dyes, namely bromocresol purple and bromocresol green. The performance of the device is evaluated in terms of the results obtained during actual measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication and characterization of a fibre optic pH sensor based on evanescent wave absorption is presented. The unclad portion of a multi-mode optical fibre is coated with a pH sensitive dye, which is immobilized by the sol–gel route. The sensitivity of the device has been found to increase when multiple sol–gel coatings are used as the sensing region. The dynamic range and the temporal response of the sensor are investigated for two different dyes, namely bromocresol purple and bromocresol green. The performance of the device is evaluated in terms of the results obtained during actual measurements

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication and characterization of a fibre optic pH sensor based on evanescent wave absorption is presented. The unclad portion of a multi-mode optical fibre is coated with a pH sensitive dye, which is immobilized by the sol–gel route. The sensitivity of the device has been found to increase when multiple sol–gel coatings are used as the sensing region. The dynamic range and the temporal response of the sensor are investigated for two different dyes, namely bromocresol purple and bromocresol green. The performance of the device is evaluated in terms of the results obtained during actual measurements

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design and development of a fibre optic evanescent wave refractometer for the detection of trace amounts of paraffin oil and palm oil in coconut oil is presented. This sensor is based on a side-polished plastic optical fibre. At the sensing region, the cladding and a small portion of the core are removed and the fibre nicely polished. The sensing region is fabricated in such a manner that it sits perfectly within a bent mould. This bending of the sensing region enhances its sensitivity. The oil mixture of different mix ratios is introduced into the sensing region and we observed a sharp decrease in the output intensity. The observed variation in the intensity is found to be linear and the detection limit is 2% (by volume) paraffin oil/palm oil in coconut oil. The resolution of this refractometric sensor is of the order of 10−3. Since coconut oil is consumed in large volumes as edible oil in south India, this fibre optic sensor finds great relevance for the detection of adulterants such as paraffin oil or palm oil which are readily miscible in coconut oil. The advantage of this type of sensor is that it is inexpensive and easy to set up. Another attraction of the side-polished fibre is that only a very small amount of analyte is needed and its response time is only 7 s.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A non-invasive technique is implemented to measure a parameter which is closely related to the distensibility of large arteries, using the second derivative of the infrared photoplethysmographic waveform. Thirty subjects within the age group of 20-61 years were involved in this pilot study. Two new parameters, namely the area of the photoplethysmographic waveform under the systolic peak, and the ratio of the time delay between the systolic and the diastolic peaks and the time period of the waveform ( T/T) were studied as a function of age. It was found that while the parameter which is supposed to be a marker of distensibility of large arteries and T /T values correlate negatively with age, the area under the systolic peak correlates positively with age. The results suggest that the derived parameters could provide a simple, non-invasive means for studying the changes in the elastic properties of the vascular system as a function of age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complete thermal characterization of liquid crystal mixtures in the smectic phase consisting of various relative volume fractions of cholesterol and 1-hexadecanol have been carried out using the photoacoustic technique. Thermal diffusivity values of these liquid crystal mixtures are evaluated using the open cell photoacoustic technique whereas the thermal effusivity value is measured using the conventional photoacoustic technique. From the measured values of these transient thermophysical parameters, the thermal conductivity and heat capacity of the sample under investigation are calculated. Analyses of the results show that all the thermophysical parameters depend strongly on the volume fraction of the constituents. Results are interpreted in terms of enhanced hydrogen bonding and the consequent enhancement in cohesive thermal energy transport with increasing volume fraction of 1-hexadecanol

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complete thermal characterization of liquid crystal mixtures in the smectic phase consisting of various relative volume fractions of cholesterol and 1-hexadecanol have been carried out using the photoacoustic technique. Thermal diffusivity values of these liquid crystal mixtures are evaluated using the open cell photoacoustic technique whereas the thermal effusivity value is measured using the conventional photoacoustic technique. From the measured values of these transient thermophysical parameters, the thermal conductivity and heat capacity of the sample under investigation are calculated. Analyses of the results show that all the thermophysical parameters depend strongly on the volume fraction of the constituents. Results are interpreted in terms of enhanced hydrogen bonding and the consequent enhancement in cohesive thermal energy transport with increasing volume fraction of 1-hexadecanol

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complete thermal characterization of liquid crystal mixtures in the smectic phase consisting of various relative volume fractions of cholesterol and 1-hexadecanol have been carried out using the photoacoustic technique. Thermal diffusivity values of these liquid crystal mixtures are evaluated using the open cell photoacoustic technique whereas the thermal effusivity value is measured using the conventional photoacoustic technique. From the measured values of these transient thermophysical parameters, the thermal conductivity and heat capacity of the sample under investigation are calculated. Analyses of the results show that all the thermophysical parameters depend strongly on the volume fraction of the constituents. Results are interpreted in terms of enhanced hydrogen bonding and the consequent enhancement in cohesive thermal energy transport with increasing volume fraction of 1-hexadecanol

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we describe the use of an open cell photoacoustic configuration for the evaluation of the thermal effusivity of liquid crystals. The feasibility, precision and reliability of the method are initially established by measuring the thermal effusivities of water and glycerol, for which the effusivity values are known accurately. In order to demonstrate the use of the present method in the thermal characterization of liquid crystals, we have measured the thermal effusivity values in various mesophases of 4-cyano-4 - octyloxybiphenyl (8OCB) and 4-cyano-4 -heptyloxybiphenyl (7OCB) liquid crystals using a variable temperature open photoacoustic cell. A comparison of the measured values for the two liquid crystals shows that the thermal effusivities of 7OCB in the nematic and isotropic phases are slightly less than those of 8OCB in the corresponding phases

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we describe the use of an open cell photoacoustic configuration for the evaluation of the thermal effusivity of liquid crystals. The feasibility, precision and reliability of the method are initially established by measuring the thermal effusivities of water and glycerol, for which the effusivity values are known accurately. In order to demonstrate the use of the present method in the thermal characterization of liquid crystals, we have measured the thermal effusivity values in various mesophases of 4-cyano-4 - octyloxybiphenyl (8OCB) and 4-cyano-4 -heptyloxybiphenyl (7OCB) liquid crystals using a variable temperature open photoacoustic cell. A comparison of the measured values for the two liquid crystals shows that the thermal effusivities of 7OCB in the nematic and isotropic phases are slightly less than those of 8OCB in the corresponding phases