980 resultados para IgM anti-glicolipido fenolico-I (IgM ANTI GF-I) UltramicroELISA


Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: To review measles IgM-positive cases of febrile rash illnesses in the State of São Paulo, Brazil, over the five-year period following interruption of measles virus transmission. METHODS: We reviewed 463 measles IgM-positive cases of febrile rash illness in the State of São Paulo, from 2000 to 2004. Individuals vaccinated against measles < 56 days prior to specimen collection were considered to be exposed to the vaccine. Serum from the acute and convalescent phases was tested for evidence of measles, rubella, parvovirus B19 and human herpes virus-6 infection. In the absence of seroconversion to measles immunoglobulin-G, measles IgM-positive cases were considered false positives in individuals with evidence of other viral infections. RESULTS: Among the 463 individuals with febrile rash illness who tested positive for measles IgM antibodies during the period, 297 (64%) were classified as exposed to the vaccine. Among the 166 cases that were not exposed to the vaccine, 109 (66%) were considered false positives based on the absence of seroconversion, among which 21 (13%) had evidence of rubella virus infection, 49 (30%) parvovirus B19 and 28 (17%) human herpes virus-6 infection. CONCLUSIONS: Following the interruption of measles virus transmission, thorough investigation of measles IgM-positive cases is required, especially among cases not exposed to the vaccine. Laboratory testing for etiologies of febrile rash illness aids interpretation of these cases.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: Cytomegalovirus (CMV) infection is a matter of concern for blood bank professionals and blood transfusion recipients, especially in cases of transfusions to neonates and immunocompromised patients. Thus, the present study aimed to determine the seroprevalence of CMV IgG and IgM antibodies among blood donors in the city of Lages, in the mountain region of Santa Catarina, southern Brazil, and to investigate possible associations between the socioeconomic characteristics of donors and CMV serological status. METHODS: A seroepidemiological cross-sectional study was conducted on 1,045 blood samples from donors that were used in serological screening over a one-year investigation. All the analyses were conducted using the microparticle enzyme immunoassay with Biokit® reagents (Barcelona, Spain), in accordance with the manufacturer's instructions. RESULTS: Anti-CMV IgG seroprevalence in the sample studied was 96.4% (95% CI: 95.23 - 97.50) and that of anti-CMV IgM was 2.3% (95% CI: 1.39 - 3.20). There were no statistically significant associations between the presence of antibodies and the socioeconomic characteristics of donors. CONCLUSIONS: The blood donors in the study region had high seroprevalence of anti-CMV IgG. Thus, blood component screening strategies and careful indication for blood transfusions require special attention among healthcare professionals as part of the actions for prevention and reduction of primary infections caused by CMV.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

in PEREIRA, Dionisio (coord.). 2013. Emigrantes, Exilados e Perseguidos - A comunidade portuguesa na galiza (1890-1940), Santiago de Compostela, Através Editora.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: Vaccination is the main tool for preventing hepatitis B virus (HBV) infection; however, following the completion of the vaccination series, the concentrations of anti-HBs can decline over the years and reach levels less than 10mIU/mL. The persistence of protection in these individuals is still unknown. The present study aimed to determine the anti-HBs antibody levels among children and adolescents who had received a complete vaccination course for hepatitis B. METHODS: Antibodies against HBV surface antigen (anti-HBs) were tested in 371 individuals aged 10 to 15 years-old. RESULTS: Volunteers who showed undetectable quantities of anti-HBs accounted for 10.2% of the population studied and 39.9% presented antibody titers of less than 10mIU/mL. Anti-HBs > 10mIU/mL were verified in 49.9%. CONCLUSIONS: These results corroborate other studies indicating levels of anti-HBs below 10mIU/mL in vaccinated individuals. Additional studies are required to assess whether this indicates susceptibility to HBV infection and the need and age for booster doses.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: The aim of this study was to evaluate the frequency of anti-Toxocara antibodies in serum from 7-year-old children attending elementary school in Vitória-ES, Brazil and to correlate these antibodies with socio-demographic factors, the presence of intestinal helminths, blood eosinophil numbers, past history of allergy or asthma, and clinical manifestations of helminth infections. METHODS: The detection of anti-Toxocara antibodies was performed using an ELISA (Cellabs Pty Ltd)on serum from 391 children who had already been examined by fecal examination and blood cell counts. Data from clinical and physical examinations were obtained for all children. RESULTS: The prevalence of anti-Toxocara antibodies was 51.6%, with no gender differences. No significant differences were observed between positive serology and the presence or absence of intestinal worms (60.3 and 51.7%, respectively; p = 0.286). The only variables significantly related to positive serology were onycophagy and the use of unfiltered water. Although eosinophilia (blood eosinophil count higher than 600/mm³) was significantly related to the presence of a positive ELISA result, this significance disappeared when we considered only children without worms or without a past history of allergy or asthma. No clinical symptoms related to Toxocara infection were observed. CONCLUSIONS: There is a high prevalence of anti-Toxocara antibodies in children attending elementary schools in Vitória, which may be partially related to cross-reactivity with intestinal helminths or to a high frequency of infection with a small number of Toxocara eggs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: The production of anti-Cryptosporidium polyclonal antibodies and its use in direct immunofluorescence assays to determine the presence of Cryptosporidium in water are described in the present work. METHODS: Two rabbits were immunized with soluble and particulate antigens from purified Cryptosporidium oocysts. The sera produced were prepared for immunoglobulin G extraction, which were then purified and conjugated with fluorescein isothiocyanate (FITC). Slides containing known amounts of oocysts were prepared to determine the sensitivity of the technique. To test the specificity, slides containing Giardia duodenalis cysts were prepared. RESULTS: The conjugate was successfully used in water samples experimentally contaminated with Cryptosporidium oocysts, and it was possible to detect up to five oocysts/spot, corresponding to contamination of 250 oocysts/mL. CONCLUSIONS: The three immunizations performed in the rabbits were enough to produce antibodies against Cryptosporidium, the standard direct immunofluorescence assay permitted the detection of five oocysts in 20% of the samples, and no cross-reaction with Giardia duodenalis cysts occurred.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: The goal was to develop an in-house serological method with high specificity and sensitivity for diagnosis and monitoring of Chagas disease morbidity. METHODS: With this purpose, the reactivities of anti-T. cruzi IgG and subclasses were tested in successive serum dilutions of patients from Berilo municipality, Jequitinhonha Valley, Minas Gerais, Brazil. The performance of the in-house ELISA was also evaluated in samples from other relevant infectious diseases, including HIV, hepatitis C (HCV), syphilis (SYP), visceral leishmaniasis (VL), and American tegumentary leishmaniasis (ATL), and noninfected controls (NI). Further analysis was performed to evaluate the applicability of this in-house methodology for monitoring Chagas disease morbidity into three groups of patients: indeterminate (IND), cardiac (CARD), and digestive/mixed (DIG/Mix), based on their clinical status. RESULTS: The analysis of total IgG reactivity at serum dilution 1:40 was an excellent approach to Chagas disease diagnosis (100% sensitivity and specificity). The analysis of IgG subclasses showed cross-reactivity, mainly with NI, VL, and ATL, at all selected serum dilutions. Based on the data analysis, the IND group displayed higher IgG3 levels and the DIG/Mix group presented higher levels of total IgG as compared with the IND and CARD groups. CONCLUSIONS: These findings demonstrated that methodology presents promising applicability in the analysis of anti-T. cruzi IgG reactivity for the differential diagnosis and evaluation of Chagas disease morbidity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: Since the emergence of antiretroviral therapy, the survival of patients infected with human immunodeficiency virus has increased. Non-adherence to this therapy is directly related to treatment failure, which allows the emergence of resistant viral strains. METHODS: A retrospective descriptive study of the antiretroviral dispensing records of 229 patients from the Center for Health Care, University Hospital, Federal University of Juiz de Fora, Brazil, was conducted between January and December 2009. RESULTS: The study aimed to evaluate patient compliance and determine if there was an association between non-adherence and the therapy. Among these patients, 63.8% were men with an average age of 44.0 ± 9.9 years. The most used treatment was a combination of 2 nucleoside reverse transcriptase inhibitors with 1 non-nucleoside reverse transcriptase inhibitor (55.5%) or with 2 protease inhibitors (28.8%). It was found that patients taking lopinavir/ritonavir with zidovudine and lamivudine had a greater frequency of inadequate treatment than those taking atazanavir with zidovudine and lamivudine (85% and 83.3%, respectively). Moreover, when the combination of zidovudine/ lamivudine was used, the patients were less compliant (χ2 = 4.468, 1 degree of freedom, p = 0.035). CONCLUSIONS: The majority of patients failed to correctly adhere to their treatment; therefore, it is necessary to implement strategies that lead to improved compliance, thus ensuring therapeutic efficacy and increased patient survival.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: The diagnosis of dengue and the differentiation between primary and secondary infections are important for monitoring the spread of the epidemic and identifying the risk of severe forms of the disease. The detection of immunoglobulin (Ig)M and IgG antibodies is the main technique for the laboratory diagnosis of dengue. The present study assessed the application of a rapid test for dengue concerning detection of new cases, reinfection recognition, and estimation of the epidemic attack rate. METHODS: This was a retrospective, cross-sectional, descriptive study on dengue using the Fortaleza Health Municipal Department database. The results from 1,530 tested samples, from 2005-2006, were compared with data from epidemiological studies of dengue outbreaks in 1996, 2003, and 2010. RESULTS: The rapid test confirmed 52% recent infections in the tested patients with clinical suspicion of dengue: 40% detected using IgM and 12% of new cases using IgG in the non-reactive IgM results. The positive IgM plus negative IgG (IgM+ plus IgG-) results showed that 38% of those patients had a recent primary dengue infection, while the positive IgG plus either positive or negative IgM (IgG+ plus IgM+/-) results indicated that 62% had dengue for at least a second time (recent secondary infections). This proportion of reinfections permitted us to estimate the attack rate as >62% of the population sample. CONCLUSIONS: The rapid test for dengue has enhanced our ability to detect new infections and to characterize them into primary and secondary infections, permitting the estimation of the minimal attack rate for a population during an outbreak.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: This study aimed to evaluate the response to hepatitis B (HB) revaccination of healthcare workers (HCW) who are negative for antibodies to HB surface antigen (anti-HBs) after a complete vaccination series. METHODS: HCW whose anti-HBs test was performed > 90 days after a HB vaccination course were given a 4th dose. A post-vaccination test was done within 30 to 90 days. RESULTS: One hundred and seventy HCW were enrolled: 126 (74.1%) were anti-HBs-positive after the 4th dose. CONCLUSIONS: Rechecking anti-HBs after the 4th HB vaccine dose is a practical approach in case of post-vaccination tests performed >90 days after the full vaccination course.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: The flu, a condition that can affect the elderly by increasing the risk of serious complications can be prevented through vaccination. Estimate the prevalence of signs and symptoms suggestive of influenza in a group of elderly either vaccinated or unvaccinated against influenza was the objective this study. METHODS: This is a cross-sectional study performed in a Brazilian City. A structured questionnaire was employed to identify the presence of signs and symptoms of influenza in individuals aged 60 years or over. For analysis of associations between variables the prevalence ratio (PR) and its 95% confidence interval (95% CI) were used. RESULTS: One hundred ninety-six participants were interviewed, of whom 57.7% were female. The average age was 69.7 years. About 25% of the vaccinated and 20% of the unvaccinated in 2009, and 25% of the vaccinated and 22.5% of the unvaccinated in 2010 reported having the flu. Among the vaccinated and unvaccinated in 2009 and 2010, there was no verified association between vaccination and influenza (PR=1.24; [95% CI: 0.63-2.43] and PR=1.11; [95% CI: 0.59-2.09], respectively). CONCLUSIONS: This study suggests that, among the elderly selected, the vaccination coverage for influenza is below the ideal, even with projection of the best indices for 2011 (~ 84%). The data on vaccination and disease protection needs further research; however, the results point to the need for measures to better clarify to this population about the disease, its complications and the benefits of vaccination, in addition to combatting the stigma related to low adherence.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

IntroductionTo determine the prevalence of immunoglobulin G (IgG) and immunoglobulin M (IgM) anti-Toxoplasma gondii antibodies among pregnant and postpartum women attended within the public healthcare system in Niterói, State of Rio de Janeiro, and to detect possible exposure factors associated with T. gondii infection in this population.MethodsIgM and IgG anti-T. gondii antibodies were investigated in 276 pregnant and 124 postpartum women by using the indirect immunofluorescence (IFAT) and immunoenzymatic assay (ELISA) techniques. The participants were selected by convenience sampling. All these 400 patients filled out a free and informed consent statement, answered an epidemiological questionnaire and were informed about the disease.ResultsAmong the 400 samples analyzed, 234 (58.5%) were reactive to IgG anti-T. gondii antibodies, according to the IFAT and/or ELISA assay. One pregnant woman was found to be reactive to IgM anti-T. gondii antibodies, with an intermediate IgG avidity test. Risk factor analysis showed that seropositivity was significantly associated (p<0.05) with age, contact with cats and presence of rodents at home. Through a logistic regression model, these associations were confirmed for age and contact with cats, while education at least of the high school level was found to be a protective factor.ConclusionsThe prevalence rate of IgG anti-T. gondii antibodies in the City of Niterói was high and the risk factors for infection detected after multivariate analysis were: age over 30 years, contact with cats and education levels lower than university graduate level.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Dengue is prevalent in many tropical and sub-tropical regions. The clinical diagnosis of dengue is still complex, and not much data are available. This work aimed at assessing the diagnostic accuracy of the tourniquet test in patients with suspected dengue infection and its positivity in different classifications of this disease as reported to the Information System for Notifiable Disease in Belo Horizonte, State of Minas Gerais, Brazil between 2001 and 2006. Methods Cross-section analysis of the diagnostic accuracy of the tourniquet test for dengue, using IgM-anti-DENV ELISA as a gold standard. Results We selected 9,836 suspected cases, of which 41.1% were confirmed to be dengue. Classic dengue was present in 95.8%, dengue with complications in 2.5% and dengue hemorrhagic fever in 1.7%. The tourniquet test was positive in 16.9% of classic dengue cases, 61.7% of dengue cases with complications and 82.9% of cases of dengue hemorrhagic fever. The sensitivity and specificity of the tourniquet test were 19.1% and 86.4%, respectively. Conclusions A positive tourniquet test can be a valuable tool to support diagnosis of dengue where laboratory tests are not available. However, the absence of a positive test should not be read as the absence of infection. In addition, the tourniquet test was demonstrated to be an indicator of dengue severity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Toxoplasmosis may be life-threatening in fetuses and in immune-deficient patients. Conventional laboratory diagnosis of toxoplasmosis is based on the presence of IgM and IgG anti-Toxoplasma gondii antibodies; however, molecular techniques have emerged as alternative tools due to their increased sensitivity. The aim of this study was to compare the performance of 4 PCR-based methods for the laboratory diagnosis of toxoplasmosis. One hundred pregnant women who seroconverted during pregnancy were included in the study. The definition of cases was based on a 12-month follow-up of the infants. Methods Amniotic fluid samples were submitted to DNA extraction and amplification by the following 4 Toxoplasma techniques performed with parasite B1 gene primers: conventional PCR, nested-PCR, multiplex-nested-PCR, and real-time PCR. Seven parameters were analyzed, sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), negative likelihood ratio (NLR) and efficiency (Ef). Results Fifty-nine of the 100 infants had toxoplasmosis; 42 (71.2%) had IgM antibodies at birth but were asymptomatic, and the remaining 17 cases had non-detectable IgM antibodies but high IgG antibody titers that were associated with retinochoroiditis in 8 (13.5%) cases, abnormal cranial ultrasound in 5 (8.5%) cases, and signs/symptoms suggestive of infection in 4 (6.8%) cases. The conventional PCR assay detected 50 cases (9 false-negatives), nested-PCR detected 58 cases (1 false-negative and 4 false-positives), multiplex-nested-PCR detected 57 cases (2 false-negatives), and real-time-PCR detected 58 cases (1 false-negative). Conclusions The real-time PCR assay was the best-performing technique based on the parameters of Se (98.3%), Sp (100%), PPV (100%), NPV (97.6%), PLR (∞), NLR (0.017), and Ef (99%).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction Acinetobacter baumannii has attained an alarming level of resistance to antibacterial drugs. Clinicians are now considering the use of older agents or unorthodox combinations of licensed drugs against multidrug-resistant strains to bridge the current treatment gap. We investigated the in vitro activities of combination treatments that included colistin with vancomycin, norvancomycin or linezolid against multidrug-resistant Acinetobacter baumannii. Methods The fractional inhibitory concentration index and time-kill assays were used to explore the combined effects of colistin with vancomycin, norvancomycin or linezolid against 40 clinical isolates of multidrug-resistant Acinetobacter baumannii. Transmission electron microscopy was performed to evaluate the interactions in response to the combination of colistin and vancomycin. Results The minimum inhibitory concentrations (MICs) of vancomycin and norvancomycin for half of the isolates decreased below the susceptibility break point, and the MIC of linezolid for one isolate was decreased to the blood and epithelial lining fluid concentration using the current dosing regimen. When vancomycin or norvancomycin was combined with subinhibitory doses of colistin, the multidrug-resistant Acinetobacter baumannii test samples were eradicated. Transmission electron microscopy revealed that subinhibitory doses of colistin were able to disrupt the outer membrane, facilitating a disruption of the cell wall and leading to cell lysis. Conclusions Subinhibitory doses of colistin significantly enhanced the antibacterial activity of vancomycin, norvancomycin, and linezolid against multidrug-resistant Acinetobacter baumannii.