940 resultados para Graph Decomposition


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the 2% ibopamine provocative test with the water drinking test as a provocative test for glaucoma. METHODS: Primary open-angle glaucoma patients and normal individuals were selected from CEROF-Universidade Federal de Goiânia UFG, and underwent the 2% ibopamine provocative test and the water drinking test in a randomized fashion, at least 1 week apart. Intraocular pressure (IOP) before and after both tests, Bland-Altman graph, sensitivity and specificity (as mesured by ROC curves) were obtained for both methods. RESULTS: Forty-seven eyes from 25 patients were included (27 eyes from 15 glaucoma patients and 20 eyes from 10 normal individuals), with a mean age of 54.2 ± 12.7 years. The mean MD of glaucoma patients was -2.8 ± 2.11 dB. There was no statistically difference in the baseline IOP (p=0.8) comparing glaucoma patients, but positive after the provocative tests (p=0.03), and in the IOP variation (4.4 ± 1.3 mmHg for ibopamine and 3.2 ± 2.2 mmHg for water drinking test, p=0.01). There was no difference in all studied parameters for normal individuals. The Bland-Altman graph showed high dispersion comparing both methods. The areas under the ROC curve were 0.987 for the ibopamine provocative test, and 0.807 for the water-drinking test. CONCLUSION: In this selected subgroup of glaucoma patients with early visual field defect, the ibopamine provocative test has shown better sensitivity/specificity than the water drinking test.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A desintegração radioativa é um processo aleatório e a estimativa de todas as medidas associadas é governada por leis estatísticas. Os perfis de taxas de contagem são sempre "ruidosos" quando utilizados períodos curtos como um segundo para cada medida. Os filtros utilizados e posteriormente as correções feitas no processamento atual de dados gamaespectrométricos não são suficientes para remover ou diminuir, consideravelmente, o ruído oriundo do espectro. Dois métodos estatísticos que atuam diretamente nos dados coletados, isto é, nos espectros, vêm sendo sugeridos na literatura para remover e minimizar estes ruídos remanescentes o Noise-Adjusted Singular Value Decomposition - NASVD e Maximum Noise Fraction - MNF. Estes métodos produzem uma redução no ruído de forma significativa. Neste trabalho eles foram implementados dentro do ambiente de processamento do software Oasis Montaj e aplicados na área compreendida pelos blocos I e II do levantamento aerogeofísico que recobre a porção oeste da Província Mineral do Tapajós, entre os Estados do Pará e Amazonas. Os dados filtrados e não-filtrados com as técnicas de NASVD e MNF foram processados com os parâmetros e constantes fornecidos pela empresa Lasa Engenharia e Prospecções S.A., sendo estes comparados. Os resultados da comparação entre perfis e mapas apresentaram-se de forma promissora, pois houve um ganho na resolução dos produtos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Lattes platform is the major scientific information system maintained by the National Council for Scientific and Technological Development (CNPq). This platform allows to manage the curricular information of researchers and institutions working in Brazil based on the so called Lattes Curriculum. However, the public information is individually available for each researcher, not providing the automatic creation of reports of several scientific productions for research groups. It is thus difficult to extract and to summarize useful knowledge for medium to large size groups of researchers. This paper describes the design, implementation and experiences with scriptLattes: an open-source system to create academic reports of groups based on curricula of the Lattes Database. The scriptLattes system is composed by the following modules: (a) data selection, (b) data preprocessing, (c) redundancy treatment, (d) collaboration graph generation among group members, (e) research map generation based on geographical information, and (f) automatic report creation of bibliographical, technical and artistic production, and academic supervisions. The system has been extensively tested for a large variety of research groups of Brazilian institutions, and the generated reports have shown an alternative to easily extract knowledge from data in the context of Lattes platform. The source code, usage instructions and examples are available at http://scriptlattes.sourceforge.net/.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of thermoanalytical data in sample preparation is described as a tool to catch the students' attention to some details that can simplify both the analysis and the analytical procedure. In this case, the thermal decomposition of eggshells was first investigated by thermogravimetry (TGA). Although the classical procedures suggest long exposure to high temperatures, the TGA data showed that the decomposition of organic matter takes place immediately when the sample is heated up to 800 °C under air atmosphere. After decomposition, the calcium content was determined by flame atomic emission photometry and compared with the results obtained using classical volumetric titration with EDTA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Alkaline salts of the palmitic acid were synthesized and characterized from aqueous and ethanolic medium. The salts were characterized by elemental analysis (EA) and infrared spectroscopy (IR). EA and IR, being its synthesis comproved, also characterized the ethyl palmitate. All the salts and the ester were submitted to thermal analysis using thermogravimetry (TG), and differential thermal analysis (DTA) in the temperature ranging from room to 700 ºC under air dynamic atmosphere. Differential scanning calorimetry (DSC) measurements were taken from -90 ºC up to temperatures close to the starting of the decomposition temperature, determined by thermogravimetry, using heating and cooling cycles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermoanalytical behavior of sodium and potassium salts of pyrrolidinedithiocarbamate (pyr), piperidineditiocarbamate (pip), morpholinedithiocarbamate (mor), hexametileneiminedithiocarbamate (hex), were investigated. In a first step the salts were synthesized and characterized by infrared spectroscopy (FTIR), ¹H and 13C nuclear magnetic resonance (NMR) and elementar analysis. Finally, thermal analytical (TG/DTG and DSC) studies were performed in order to evaluate the thermal stability, as well as the pathways of the thermal decomposition based in the intermediate and final decomposition products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the construction and testing of a simple pressurized solvent extraction (PSE) system. A mixture of acetone:water (80:20), 80 ºC and 103.5 bar, was used to extract two herbicides (Diuron and Bromacil) from a sample of polluted soil, followed by identification and quantification by high-performance liquid chromatography coupled with diode array detector (HPLC-DAD). The system was also used to extract soybean oil (70 ºC and 69 bar) using pentane. The extracted oil was weighed and characterized through the fatty acid methyl ester analysis (myristic (< 0.3%), palmitic (16.3%), stearic (2.8%), oleic (24.5%), linoleic (46.3%), linolenic (9.6%), araquidic (0.3%), gadoleic (< 0.3%), and behenic (0.3%) acids) using high-resolution gas chromatography with flame ionization detection (HRGC-FID). PSE results were compared with those obtained using classical procedures: Soxhlet extraction for the soybean oil and solid-liquid extraction followed by solid-phase extraction (SLE-SPE) for the herbicides. The results showed: 21.25 ± 0.36% (m/m) of oil in the soybeans using the PSE system and 21.55 ± 0.65% (m/m) using the soxhlet extraction system; extraction efficiency (recovery) of herbicides Diuron and Bromacil of 88.7 ± 4.5% and 106.6 ± 8.1%, respectively, using the PSE system, and 96.8 ± 1.0% and 94.2 ± 3.9%, respectively, with the SLP-SPE system; limit of detection (LOD) and limit of quantification (LOQ) for Diuron of 0.012 mg kg-1 and 0.040 mg kg-1, respectively; LOD and LOQ for Bromacil of 0.025 mg kg-1 and 0.083 mg kg-1, respectively. The linearity used ranged from 0.04 to 1.50 mg L-1 for Diuron and from 0.08 to 1.50 mg L-1 for Bromacil. In conclusion, using the PSE system, due to high pressure and temperature, it is possible to make efficient, fast extractions with reduced solvent consumption in an inert atmosphere, which prevents sample and analyte decomposition.