967 resultados para Field assisted sintering technique
Resumo:
This paper is a contribution for the assessment and comparison of magnet properties based on magnetic field characteristics particularly concerning the magnetic induction uniformity in the air gaps. For this aim, a solver was developed and implemented to determine the magnetic field of a magnetic core to be used in Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometry. The electromagnetic field computation is based on a 2D finite-element method (FEM) using both the scalar and the vector potential formulation. Results for the magnetic field lines and the magnetic induction vector in the air gap are presented. The target magnetic induction is 0.2 T, which is a typical requirement of the FFC NMR technique, which can be achieved with a magnetic core based on permanent magnets or coils. In addition, this application requires high magnetic induction uniformity. To achieve this goal, a solution including superconducting pieces is analyzed. Results are compared with a different FEM program.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
V Congreso de Eficiencia y Productividad EFIUCO, Córdoba, 19-20 Mayo 2011.
Resumo:
Tese de Doutoramento, Ciências do Mar (Ecologia Marinha), 26 de Novembro de 2013, Universidade dos Açores.
Resumo:
Mestrado em Engenharia Geotécnica e Geoambiente
Resumo:
Frame rate upconversion (FRUC) is an important post-processing technique to enhance the visual quality of low frame rate video. A major, recent advance in this area is FRUC based on trilateral filtering which novelty mainly derives from the combination of an edge-based motion estimation block matching criterion with the trilateral filter. However, there is still room for improvement, notably towards reducing the size of the uncovered regions in the initial estimated frame, this means the estimated frame before trilateral filtering. In this context, proposed is an improved motion estimation block matching criterion where a combined luminance and edge error metric is weighted according to the motion vector components, notably to regularise the motion field. Experimental results confirm that significant improvements are achieved for the final interpolated frames, reaching PSNR gains up to 2.73 dB, on average, regarding recent alternative solutions, for video content with varied motion characteristics.
Resumo:
This paper reports a novel application of microwave-assisted extraction (MAE) of polyphenols from brewer’s spent grains (BSG). A 24 orthogonal composite design was used to obtain the optimal conditions of MAE. The influence of the MAE operational parameters (extraction time, temperature, solvent volume and stirring speed) on the extraction yield of ferulic acid was investigated through response surface methodology. The results showed that the optimal conditions were 15 min extraction time, 100 °C extraction temperature, 20 mL of solvent, and maximum stirring speed. Under these conditions, the yield of ferulic acid was 1.31±0.04% (w/w), which was fivefold higher than that obtained with conventional solid–liquid extraction techniques. The developed new extraction method considerably reduces extraction time, energy and solvent consumption, while generating fewer wastes. HPLC-DADMS analysis indicated that other hydroxycinnamic acids and several ferulic acid dehydrodimers, as well as one dehydrotrimer were also present, confirming that BSG is a valuable source of antioxidant compounds.
Resumo:
Dissertação Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica no perfil de Manutenção e Produção
Resumo:
The measurement of room impulse response (RIR) when there are high background noise levels frequently means one must deal with very low signal-to-noise ratios (SNR). if such is the case, the measurement might yield unreliable results, even when synchronous averaging techniques are used. Furthermore, if there are non-linearities in the apparatus or system time variances, the final SNR can be severely degraded. The test signals used in RIR measurement are often disturbed by non-stationary ambient noise components. A novel approach based on the energy analysis of ambient noise - both in the time and in frequency - was considered. A modified maximum length sequence (MLS) measurement technique. referred to herein as the hybrid MLS technique, was developed for use in room acoustics. The technique consists of reducing the noise energy of the captured sequences before applying the averaging technique in order to improve the overall SNRs and frequency response accuracy. Experiments were conducted under real conditions with different types of underlying ambient noises. Results are shown and discussed. Advantages and disadvantages of the hybrid MLS technique over standard MLS technique are evaluated and discussed. Our findings show that the new technique leads to a significant increase in the overall SNR. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
An accurate and sensitive method for determination of 18 polycyclic aromatic hydrocarbons (PAHs) (16 PAHs considered by USEPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) in fish samples was validated. Analysis was performed by microwave-assisted extraction and liquid chromatography with photodiode array and fluorescence detection. Response surface methodology was used to find the optimal extraction parameters. Validation of the overall methodology was performed by spiking assays at four levels and using SRM 2977. Quantification limits ranging from 0.15–27.16 ng/g wet weight were obtained. The established method was applied in edible tissues of three commonly consumed and commercially valuable fish species (sardine, chub mackerel and horse mackerel) originated from Atlantic Ocean. Variable levels of naphthalene (1.03–2.95 ng/g wet weight), fluorene (0.34–1.09 ng/g wet weight) and phenanthrene (0.34–3.54 ng/g wet weight) were detected in the analysed samples. None of the samples contained detectable amounts of benzo[a]pyrene, the marker used for evaluating the occurrence and carcinogenic effects of PAHs in food.
Resumo:
Mestrado em Engenharia Geotécnica e Geoambiente
Resumo:
Purpose: The aim of this paper is to promote qualitative methodology within the scientific community of management. The specific objective is oriented to propose an empirical research process based on case study method. This is to ensure rigor in the empirical research process, that future research may follow a similar procedure to that is proposed. Design/methodology/approach: Following a qualitative methodological approach, we propose a research process that develops according to four phases, each with several stages. This study analyses the preparatory and field work phases and their stages. Findings: The paper shows the influence that case studies have on qualitative empirical research process in management. Originality/value:. Case study method assumes an important role within qualitative research by allowing for the study and analysis of certain types of phenomena that occur inside organisations, and in respect of which quantitative studies cannot provide an answer.
Resumo:
Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.
Resumo:
Introduction: In the XXI Century ’s Society the scientific investigation process has been growing steadily , and the field of the pharmaceutical research is one of the most enthusiastic and relevant . Here, it is very important to correlate observed functional alterations with possibly modified drug bio distribution patterns . Cancer, inflammation and inf ection are processes that induce many molecular intermediates like cytokines, chemokines and other chemical complexes that can alter the pharmacokinetics of many drugs. One cause of such changes is thought to be the modulator action of these complexes in t he P - Glyco p rotein activity, because they can act like inducers/inhibitors of MDR - 1 expression. This protein results from the expression of MDR - 1 gene, and acts as an ATP energy - dependent efflux pump, with their substrates including many drugs , like antiretrovirals, anticancers, anti - infectives, immunosuppressants, steroids or opioids . Objectives: Because of the lack of methods to provide helpful information in the investigation of in vivo molecular changes in Pgp activity during infection/infl ammation processes, and its value in the explanation of the altered drug pharmacokinetic, this paper want to evaluate the potential utility of 99m Tc - Sestamibi scintigraphy during this kind of health sciences investigation. Although the a im is indeed to create a technique to the in vivo study of Pgp activity, this preliminary Project only reaches the in vitro study phase, assumed as the first step in a n evaluation period for a new tool development. Materials and Methods: For that reason , we are performing in vitro studies of influx and efflux of 99m Tc - Sestamibi ( that is a substrate of Pgp) in hepatocytes cell line (HepG2). We are interested in clarify the cellular behavior of this radiopharmaceutical in Lipopolysaccharide(LPS) stimulated cells ( well known in vitro model of inflammation) to possibly approve this methodology. To validate the results, the Pgp expression will be finally evaluated using Western Blot technique. Results: Up to this moment , we still don’t have the final results, but we have already enough data to let us believe that LPS stimulation induce a downregulation of MDR - 1, and consequently Pgp, which could conduce to a prolonged retention of 99m Tc - Sestamibi in the inflamed cells . Conclusions: If and when this methodology demonstrate the promising results we expect, one will be able to con clude that Nuclear Medicine is an important tool to help evidence based research also on this specific field .
Resumo:
Este trabalho pretende enfatizar a importância da elaboração de uma base de dados extensa e robusta para o melhoramento da cartografia geotécnica subterrânea do maciço granítico do sector de Carvalhido–Burgães (Porto). Este estudo envolveu a análise e o refinamento das principais características geomecânicas ao longo de um traçado com cerca de 1220 m, para a caracterização do maciço rochoso da galeria subterrânea Carvalhido–Burgães. Para esta caracterização foram coligidos e uniformizados dados geológicos, geotécnicos e geomecânicos relativos a várias campanhas de campo, realizadas entre 2005 e 2011, tendo estado a técnica da amostragem linear aplicada ao grau de compartimentação do maciço rochoso na base do seu estudo. Além disso, procedeu‐se a um tratamento estatístico das descontinuidades, bem como dos parâmetros geológico‐geotécnicos e geomecânicos a estas associados. O zonamento geotécnico do maciço granítico foi realizado sempre em estreita ligação com o conhecimento das características do maciço in situ. Pretende‐se que esta metodologia contribua para um melhor conhecimento da compartimentação dos maciços rochosos em geral e, em particular, do modelo geomecânico comportamental do maciço rochoso do Porto.