966 resultados para Enhanced biological phosphate removal (EBPR)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presented work was conducted within the Dissertation / Internship, branch of Environmental Protection Technology, associated to the Master thesis in Chemical Engineering by the Instituto Superior de Engenharia do Porto and it was developed in the Aquatest a.s, headquartered in Prague, in Czech Republic. The ore mining exploitation in the Czech Republic began in the thirteenth century, and has been extended until the twentieth century, being now evident the consequences of the intensive extraction which includes contamination of soil and sub-soil by high concentrations of heavy metals. The mountain region of Zlaté Hory was chosen for the implementation of the remediation project, which consisted in the construction of three cells (tanks), the first to raise the pH, the second for the sedimentation of the formed precipitates and a third to increase the process efficiency in order to reduce high concentrations of metals, with special emphasis on iron, manganese and sulfates. This project was initiated in 2005, being pioneer in this country and is still ongoing due to the complex chemical and biological phenomenon’s inherent to the system. At the site where the project was implemented, there is a natural lagoon, thereby enabling a comparative study of the two systems (natural and artificial) regarding the efficiency of both in the reduction/ removal of the referred pollutants. The study aimed to assist and cooperate in the ongoing investigation at the company Aquatest, in terms of field work conducted in Zlaté Hory and in terms of research methodologies used in it. Thereby, it was carried out a survey and analysis of available data from 2005 to 2008, being complemented by the treatment of new data from 2009 to 2010. Moreover, a theoretical study of the chemical and biological processes that occurs in both systems was performed. Regarding the field work, an active participation in the collection and in situ sample analyzing of water and soil from the natural pond has been attained, with the supervision of Engineer, Irena Šupiková. Laboratory analysis of water and soil were carried out by laboratory technicians. It was found that the natural lagoon is more efficient in reducing iron and manganese, being obtained removal percentages of 100%. The artificial lagoon had a removal percentage of 90% and 33% for iron and manganese respectively. Despite the minor efficiency of the constructed wetland, it must be pointed out that this system was designed for the treatment and consequent reduction of iron. In this context, it can conclude that the main goal has been achieved. In the case of sulphates, the removal optimization is yet a goal to be achieved not only in the Czech Republic but also in other places where this type of contamination persists. In fact, in the natural lagoon and in the constructed wetland, removal efficiencies of 45% and 7% were obtained respectively. It has been speculated that the water at the entrance of both systems has different sources. The analysis of the collected data shows at the entrance of the natural pond, a concentration of 4.6 mg/L of total iron, 14.6 mg/L of manganese and 951 mg/L of sulphates. In the artificial pond, the concentrations are 27.7 mg/L, 8.1 mg/L and 382 mg/L respectively for iron, manganese and sulphates. During 2010 the investigation has been expanded. The study of soil samples has started in order to observe and evaluate the contribution of bacteria in the removal of heavy metals being in its early phase. Summarizing, this technology has revealed to be an interesting solution, since in addition to substantially reduce the mentioned contaminants, mostly iron, it combines the low cost of implementation with an reduced maintenance, and it can also be installed in recreation parks, providing habitats for plants and birds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A empresa Petibol, S.A. – Embalagens de plástico centra-se na produção de embalagens de plástico a partir da matéria-prima Poliestireno Expandido (EPS) e Polipropileno Expandido (EPP). A empresa possui uma preocupação ao nível da qualidade da água e do aproveitamento energético, tendo desta forma surgido a realização do estudo na unidade industrial, com o objectivo de anular e/ou diminuir as possíveis lacunas existentes na unidade industrial. Numa primeira etapa foi realizada uma caracterização global à qualidade da água e à empresa, actualizando-se os esquemas já existentes, contabilizando-se os custos actuais relativamente aos processos no circuito da água (arrefecimento, aquecimento e pressurização), e por fim, efectuou-se um levantamento in loco do circuito de água, relativamente à pressão, temperatura e caudal. Numa fase posterior, foram propostos equipamentos e processos, tendo em vista a colmatação dos problemas identificados, realizando-se um subsequente estudo relativamente aos custos inerentes a esses novos processos. A caracterização à água foi avaliada em diferentes pontos do circuito industrial, tendo-se determinado na Sala de Bombagem que o filtro de areia não possuía as dimensões mais apropriadas, existindo também um problema a nível mecânico associado ao processo de contra-lavagem. Tais factos podem ser a causa da ocorrência de um aumento do teor de sólidos após a passagem na camada filtrante. Relativamente ao amaciador, este deveria amaciar de forma completa a água para alimentação à caldeira, embora se tenha registado à saída do amaciador uma dureza de 21,3 mg/L, denunciando problemas na troca iónica. No que toca à água de alimentação à caldeira, verifica-se a existência de parâmetros que não se encontram de acordo com os critérios enunciados para uma óptima qualidade, sendo eles o pH (10,14), condutividade (363 μS/cm), teor de ferro (1,21 mg/L) e a dureza (16 mg/L). De salientar que somente o teor de cobre, que se encontra em quantidades vestigiais, apresenta-se de acordo com os valores impostos. No que respeita à água da caldeira, esta apresenta parâmetros incompatíveis com os recomendados, sendo eles a condutividade (7350 μS/cm), teor de sólidos dissolvidos (5248 mg/L) e alcalinidade total (780 mg/L). De referir que o valor de pH (11,8) não se encontra de acordo com a aplicação do tratamento “fosfato-pH coordenado”. Em relação aos parâmetros com valores que se encontram dentro dos limites, estes correspondem à dureza (0 mg/L), ao teor de fosfatos (45 mg/L) e teor de sílica (0 mg/L). A água do circuito de arrefecimento foi sujeita a uma análise microbiológica, que corroborou a presença de um biofilme. Um dos problemas enunciados pela empresa, prendia-se com a impossibilidade de descarga, no colector municipal, dos condensados dos compressores, visto apresentarem uma quantidade de óleo de cerca de 43,3 mg/L, equivalente a quatro vezes o valor limite de emissão, de acordo com a legislação municipal. Por fim, o efluente de descarga industrial apresenta um valor de pH (10,3) acima do intervalo permitido por lei (6,0 – 9,0), sendo que a corrente que mais contribui para este acréscimo de pH corresponde à corrente proveniente da água de purga, visto esta apresentar um valor de pH de 12,22. De maneira a contornar os parâmetros enunciados, é proposto a substituição do filtro de areia da Sala de Bombagem, assim como a inserção de um conjunto de medidas de remoção de ferro e desinfecção, sendo a conjugação de arejamento, coagulação, filtração e desinfecção, por parte do hipoclorito, a proposta apresentada. Aos condensados dos compressores é apresentado um sistema de separação, que possibilita a remoção do óleo da água, e uma consequente descarga da mesma. Actualmente, não existe qualquer filtro de areia no circuito de arrefecimento da água, sendo proposto assim esse equipamento, de forma a minorar o desenvolvimento da população microbiana, bem como a permitir uma maior eficiência na transferência de calor na torre de arrefecimento. Relativamente à descarga industrial, é recomendável a colocação de um sistema de regularização automática de pH. A inserção de uma válvula de três vias permite um aproveitamento energético e de água, a partir da confluência da água oriunda dos furos com a água do tanque de água fria, sendo posteriormente alimentada à central de vácuo. No estudo da recuperação energética, um outro equipamento avaliado correspondeu à serpentina, no entanto, verificou-se que a poupança no consumo de gás natural era de apenas 0,005%, o que não se mostrou uma proposta viável. O orçamento de todos os equipamentos é de 11.720,76 €, possibilitando não só um melhor funcionamento industrial, como um menor impacto a nível ambiental. Os custos futuros de funcionamento aumentam em 3,36%, tendo a pressurização um aumento do seu custo em 3,4% em relação ao custo actual, verificando-se um custo anual de 10.781,21€, em relação aos processos de arejamento, coagulação e desinfecção.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho, elaborado entre Fevereiro e Julho de 2011, pretendeu analisar o impacto de algumas estratégias de optimização, adoptadas no âmbito da gestão de processo. As soluções estudadas tiveram como objectivo fazer face a alguns problemas de funcionamento da estação de tratamento de águas residuais (ETAR) de Crestuma, com recurso aos meios existentes. Para esse efeito foi realizada uma análise ao histórico dos registos de exploração referentes ao período de Janeiro de 2008 a Julho de 2011, pois foi considerado que este seria o período necessário para a análise e apuramento de resultados conclusivos. A ETAR fica situada na freguesia de Crestuma, actualmente com 2619 habitantes, localizada na confluência do regato de Vessadas com o rio Douro. Destina-se a tratar as águas residuais provenientes do sistema de drenagem de três localidades, S. Fioso, S. Picoto e S. Vessada, contribuindo para a despoluição do rio Douro. Genericamente, a ETAR tem apresentado um desempenho bastante satisfatório, respeitando os valores limites de emissão previstos na legislação actual (Decreto-Lei 152/97). A permanência de grandes quantidades de lama no processo, associada a uma elevada idade das lamas, está na origem da sua má sedimentabilidade, dificultando, por sua vez, a sua remoção do sistema. Com objectivo de se conseguir remover as lamas biológicas de uma forma mais eficiente, foi adoptada uma estratégia que compreendeu duas etapas. Com a finalidade de melhorar a sedimentabilidade, numa primeira etapa foi introduzido no processo um produto biológico, composto essencialmente por fungos, comercialmente conhecido por Optibiom 7450L. Com vista a obter-se uma maior eficiência na desidratação das lamas, a segunda etapa consistiu na substituição do polímero usado na lama espessada, por outro, de composição diferente, comercialmente conhecido por Easy 6040. Com as alterações introduzidas, foi possível obter um melhor controlo do processo e convergir para parâmetros de funcionamento mais próximos dos valores referidos na bibliografia. As alterações mais relevantes foram verificadas nos valores de sólidos suspensos totais (SST) no reactor biológico e na recirculação, tendo-se obtido valores médios de 3846 e 9716 mg/L, respectivamente (correspondendo a valores anteriores ao tratamento de 5301 e 7430 mg/L). Assim, a razão entre as concentrações de SST na corrente de recirculação e no reactor biológico passou de 1,4 para 2,6. A idade das lamas diminuiu de 42 para 36 dias com a adição do polímero Easy 6040 e o índice volumétrico de lamas apresentou uma redução, de 134 mL/g para 100 mL/g, o que se traduziu numa melhor sedimentabilidade das lamas. Desta forma, obteve-se uma diminuição de 33,3% no volume de lama produzida por m3 de afluente tratado, bem como uma redução de 27% no número de horas de funcionamento da centrífuga e um decréscimo ligeiro no consumo global de energia da ETAR (0,89%). Conclui-se que as alterações introduzidas no processo, adição de um produto biológico composto por fungos (Optibiom 7450L) e substituição do polímero usado na lama espessada por outro de composição diferente (Easy 6040), conduziram a uma melhoria no funcionamento do tratamento biológico da ETAR de Crestuma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho experimental teve como objectivos estudar a tratabilidade dum efluente lácteo utilizando a técnica de coagulação/floculação e avaliar a possibilidade de utilização do carvão activado granulado (CAG) Aquasorb 2000 como adsorvente para a remoção de compostos orgânicos presentes nos efluentes lácteos pré–tratados por coagulação/floculação, funcionando como um tratamento de polimento. No estudo da tratabilidade do efluente por coagulação/floculação investigou-se a influência de determinadas variáveis como o tipo e dose de coagulante e pH, a fim de encontrar as melhores condições operatórias. A utilização da referida técnica visou a redução do valor de concentração de alguns parâmetros: carência química de oxigénio (CQO); fósforo total e turvação, tendo sido utilizados efluentes desta indústria recolhidos em diferentes datas e após tratamento biológico, designados por A, B, C e D apresentando características diferentes. Sendo que o efluente A apresentava valores de CQO, fósforo total e turvação de 500 mg O2/L;32 mg P/L e 40 NTU respectivamente, o efluente B 1400 mg O2/L; 120 mg P/L e 80 NTU respectivamente, o efluente C 12300 mg O2/L; 87 mg P/L e 350 NTU respectivamente e o efluente D 340 mg O2/L; 33 mg P/L e 42 NTU respectivamente. Os coagulantes estudados foram hidróxido de cálcio (HC), sulfato de alumínio (SA) e tricloreto de ferro (TF). Verificou-se que o coagulante com maior eficácia nos efluentes estudados foi o TF. As maiores remoções de CQO, fósforo total e turvação, 89%, 99,9% e 99%, respectivamente, foram obtidas para o efluente C, com uma dosagem de TF de 4 g/L e com um pH entre 6 e 7. Entre os efluentes estudados este era o que apresentava valores iniciais mais elevados para qualquer um destes parâmetros. As melhores percentagens de remoção obtidas com o HC, para a CQO, fósforo total e turvação foram de 59%, 99% e 91%, respectivamente, com uma dosagem de HC de 1 g/L e com um pH entre 10 e 11,5 foram conseguidas no tratamento do efluente D, com o qual se alcançaram também as melhores remoções de CQO, fósforo total e turvação de 65%, 99% e 87%, respectivamente, quando se utilizou o coagulante SA, com uma dosagem de 2 g/L e com um pH entre 7 e 7,5. Relativamente ao volume de lamas produzido neste processo pela utilização dos diferentes coagulantes no tratamento dos efluentes referidos concluiu-se que o coagulante que gera menor volume de lamas é o HC, sendo o SA aquele que origina um maior volume. Submeteu-se posteriormente o efluente D, pré-tratado por coagulação/floculação, a um processo de adsorção em batch utilizando o CAG Aquasorb 2000, onde se conseguiu uma remoção de CQO de 48%, alcançando para este parâmetro o valor de 63 mg O2/L, nas condições operatórias que correspondem a uma massa de CAG de 12,5 g/L e um tempo de contacto de 3 horas. Quanto aos custos associados com os coagulantes, o que menores custos apresenta é o HC (150 €/ton), seguido pelo TF (250 €/ton) e por ultimo o SA (340 €/ton). Sendo que o efluente quando tratado com TF e SA é necessário uma correcção do pH do meio para que estes coagulantes actuem eficazmente, em que essa correcção de pH é realizada com hidróxido de sódio (540 €/ton). Realizaram-se ainda estudos de equilíbrio de adsorção com o carvão activado referido e o azul-de-metileno usando diferentes concentrações deste (50 mg/L; 100 mg/L e 200 mg/L) e diferentes massas de CAG (0,1g; 0,2g; 0,3g; 0,4g e 0,5g). A temperatura a que se realizaram estes ensaios foi de 28,7ºC e o volume de azul-de-metileno foi de 200 mL. Verificou-se que os melhores resultados obtidos foram para uma concentração de adsorvato de 100 mg/L. Ajustaram-se os modelos de Langmuir e Freundlich às isotérmicas obtidas tendo correlações mais elevadas para a concentração de 100 mg/L de corante (azul de metileno), sendo o modelo de Freundlich aquele que melhor se ajustou apresentando uma correlação quadrática de 0,9744 e os seguintes parâmetros Kf = 6,59 e n = 5,33, enquanto que o de Langmuir apresentou uma correlação quadrática de 0,9583 e os seguintes parâmetros qmáx = 83,3 mg/g de adsorvente e K = 20 L/mg de adsorvato.. Verificou-se que a capacidade de adsorção promovida pelo CAG, em relação ao azul-demetileno, obtida experimentalmente, 83,3 mg/g, é muito inferior à capacidade de adsorção teoricamente prevista pela ficha técnica deste carvão, 280 mg/g a uma temperatura de 25ºC, o que pode indiciar que o carvão utilizado não estaria nas melhores condições.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzymatic defect in the world. The most common clinical manifestations are acute hemolytic anemia associated with drugs, infections, neonatal jaundice and hemolytic non-spherocytic chronic anemia. The main aim of this study was to determine the frequency of major genetic variants of G6PD leading to enzyme deficiency in children from 0 to 14 years at a Pediatric Hospital in Luanda, Angola. A cross-sectional and descriptive analytical study covered a total of 194 children aged from 0 to 14 years, of both genders and hospitalized at the Pediatric Hospital David Bernardino, Luanda between November and December, 2011. The G202A, A376G and C563T mutations of the G6PD gene were determined by real-time PCR with Taqman probes. The disabled A-/A- genotype was detected in 10 girls (10.9%). Among the boys, 21 (20.6%) presented the genotype A-. Considering all the samples, the A- variant was observed in 22.4% of cases. The Mediterranean mutation was not detected in the Angolan sample. Furthermore, no association was found between genotype and anemia, nutritional state and mucosa color. A significant association, however, was observed with jaundice. Based on the results obtained, there is a clear need to identify those with the disabled genotype in the Angolan population in order to avoid cases of drug-induced anemia, particularly in the treatment of malaria, so prevalent in Angola.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Hidráulica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Mundotêxtil foi fundada em 1975 tendo iniciado a sua actividade na área comercial de produtos têxteis. Actualmente é o maior produtor nacional de atoalhados de felpo e emprega 575 colaboradores. Como resultado do seu crescimento e sobretudo da actividade de tingimento de fio e felpo, as necessidades de água são consideráveis e o volume de efluentes gerados nos processos industriais é cada vez maior a empresa avançou com a construção de uma estação de tratamento por lamas activadas, colocando-a em funcionamento em Setembro de 2004. Inicialmente surgiram dificuldades para a remoção da cor e da concentração da Carência Química de Oxigénio (CQO) de modo a cumprir os limites máximos de emissão permitidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98, de 1 de Agosto. Com a descarga de parte dos efluentes no SIDVA e a utilização de um coagulante adicionado ao reactor o tratamento passou a apresentar melhores resultados. O intuito deste trabalho é o de apresentar soluções de modo a optimizar o funcionamento do tratamento biológico da Mundotêxtil. A optimização pode começar na concepção dos produtos, pode incidir no processo de fabrico para além de poder ser efectuada no seio da estação de tratamento biológico. Foi efectuado um estudo do tratamento biológico por lamas activadas no Laboratório de Tecnologia Química Profª Doutora Lída de Vasconcelos, laboratório tecnológico do Instituto Superior de Engenharia do Porto (ISEP) que decorreu nos meses de Maio, Junho e Julho de 2010. O estudo laboratorial foi efectuado para três situações distintas: 1) tratamento do efluente bruto sem qualquer tipo de pré-tratamento (ensaios 1 a 3); 2) tratamento do efluente bruto submetido a pré-tratamento com coagulante Ambifloc BIO MD (ensaios 4 e 5) e 3) tratamento com adição de fungos ao tanque de arejamento (ensaio 6). Foram utilizadas duas instalações de tratamento alimentadas a partir do mesmo tanque de alimentação. Os dois sistemas eram idênticos, diferiram nos caudais de alimentação de efluente que foram alterados ao longo do estudo. O efluente a tratar foi fornecido pela empresa Mundotêxtil, sendo recolhido por diversas vezes ao longo dos ensaios. Este efluente foi retirado após o pré-tratamento da empresa, ou seja este efluente é o mesmo que alimenta o tratamento biológico da Mundotêxtil. Devido a este facto o efluente usado no estudo laboratorial teve uma variabilidade no período em que decorreu o estudo, nomeadamente em termos de concentração de CQO e cor. A relação entre a Carência Bioquímica (CBO5) e a CQO situouse entre 0,47 e 0,63 o que traduz que está dentro dos valores típicos para um efluente têxtil. Os melhores resultados globais de remoção de CQO foram obtidos no ensaio 5 e estiveram compreendidos entre 73,2% e 77,5% para o ensaio 5.1 e entre 62,9 e 73,2% para o ensaio 5.2. Neste ensaio foi utilizado o coagulante. Todos os valores de concentração de CQO obtidos nos efluentes dos decantadores para os ensaios 2, 5 e 6 são inferiores aos valores limite de descarga definidos nas normas de descarga no rio Ave e o Decreto-Lei 236/98. Os valores de concentração de Sólidos Suspensos Totais (SST), pH, fósforo, CBO5 e cor nos decantadores cumpriram os limites de descarga definidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98 em todos os ensaios. Os parâmetros cinéticos obtidos para os ensaios com descorante são os que melhor se ajustam ao projecto de uma instalação de tratamento biológico por lamas activadas do efluente da Mundotêxtil. Os valores obtidos, após ajuste, são os seguintes: k=0,015 L/(mgSSV*d); Sn=12 mg/L; a=0,7982 kgO2/kgCBO5; b=0,0233 [kgO2/(kgSSV*d); y=0,2253 kgSSV/kgCBO5; kd=0,0036 kgSSV/(kgSSV*d. Com base nos parâmetros cinéticos obtiveram-se os seguintes resultados para o projecto de uma estação de tratamento biológico por lamas activadas: · Tempo de retenção hidráulica no reactor de 1,79 d, · Volume do reactor igual a 3643 m3 · Consumo de oxigénio no reactor de 604 kg/d · Razão de recirculação igual a 0,8 · Volume total do decantador secundário igual a 540 m3 · Diâmetro do decantador secundário igual a 15 m A quantidade de oxigénio necessário é baixa e o valor mais adequado deverá ser da ordem de 1200 kg/d. Também foi efectuada uma análise aos produtos químicos consumidos pela empresa na área das tinturarias com a finalidade de identificar as substâncias com uma maior influência potencial no funcionamento da Estação de Tratamento Biológico. O encolante CB, Cera Têxtil P Líquida, Perfemina P-12, Meropan DPE-P, Meropan BRE-P, Indimina STS e Benzym TEC são os produtos químicos que têm uma influência potencial mais significativa na qualidade dos efluentes. Devido ao facto das temperaturas do efluente alimentado ao tratamento biológico da Mundotêxtil oscilarem entre 35 ºC e 43ºC efectuou-se um estudo às necessidades de água quente das tinturarias e por outro lado à capacidade de aquecimento dos efluentes disponíveis. Actualmente a racionalização dos consumos de água é cada vez mais premente, por isso também é apresentado neste trabalho um estudo para a substituição das máquinas convencionais das tinturarias com uma relação de banho 1:10 por máquinas de banho curto (1:6,5). Verifica-se a redução de consumos de 40% de água, 52% de energia eléctrica, 35% de produtos químicos, 51% das necessidades de vapor e por consequência um aumento da produtividade. A empresa pode reduzir os consumos de água em cerca de 280.000 m3/ano. A utilização do pré-tratamento com o coagulante permitirá baixar a concentração da CQO e reduzir a cor à entrada do reactor tratamento biológico. Deste modo é possível manter um tratamento eficiente à saída do tratamento biológico nas situações de descarga de cores carregadas e carga orgânica elevada. Com este conjunto de soluções, quer sejam aplicadas na totalidade ou não, a empresa Mundotêxtil pode enfrentar o futuro com mais confiança podendo estar preparada para fazer face à escassez de água e custos cada vez maiores da energia. Por outro lado pode tratar os seus efluentes a custos menores. A substituição das máquinas de tingimento por máquinas com relação de banho mais baixa (banho curto) implica investimentos elevados mas estes investimentos são necessários não só por motivos ambientais mas também devido à grande competitividade dos mercados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Teia Mundial (Web) foi prevista como uma rede de documentos de hipertexto interligados de forma a criar uma espaço de informação onde humanos e máquinas poderiam comunicar. No entanto, a informação contida na Web tradicional foi/é armazenada de forma não estruturada o que leva a que apenas os humanos a possam consumir convenientemente. Consequentemente, a procura de informações na Web sintáctica é uma tarefa principalmente executada pelos humanos e nesse sentido nem sempre é fácil de concretizar. Neste contexto, tornou-se essencial a evolução para uma Web mais estruturada e mais significativa onde é dado significado bem definido à informação de forma a permitir a cooperação entre humanos e máquinas. Esta Web é usualmente referida como Web Semântica. Além disso, a Web Semântica é totalmente alcançável apenas se os dados de diferentes fontes forem ligados criando assim um repositório de Dados Abertos Ligados (LOD). Com o aparecimento de uma nova Web de Dados (Abertos) Ligados (i.e. a Web Semântica), novas oportunidades e desafios surgiram. Pergunta Resposta (QA) sobre informação semântica é actualmente uma área de investigação activa que tenta tirar vantagens do uso das tecnologias ligadas à Web Semântica para melhorar a tarefa de responder a questões. O principal objectivo do projecto World Search passa por explorar a Web Semântica para criar mecanismos que suportem os utilizadores de domínios de aplicação específicos a responder a questões complexas com base em dados oriundos de diferentes repositórios. No entanto, a avaliação feita ao estado da arte permite concluir que as aplicações existentes não suportam os utilizadores na resposta a questões complexas. Nesse sentido, o trabalho desenvolvido neste documento foca-se em estudar/desenvolver metodologias/processos que permitam ajudar os utilizadores a encontrar respostas exactas/corretas para questões complexas que não podem ser respondidas fazendo uso dos sistemas tradicionais. Tal inclui: (i) Ultrapassar a dificuldade dos utilizadores visionarem o esquema subjacente aos repositórios de conhecimento; (ii) Fazer a ponte entre a linguagem natural expressa pelos utilizadores e a linguagem (formal) entendível pelos repositórios; (iii) Processar e retornar informações relevantes que respondem apropriadamente às questões dos utilizadores. Para esse efeito, são identificadas um conjunto de funcionalidades que são consideradas necessárias para suportar o utilizador na resposta a questões complexas. É também fornecida uma descrição formal dessas funcionalidades. A proposta é materializada num protótipo que implementa as funcionalidades previamente descritas. As experiências realizadas com o protótipo desenvolvido demonstram que os utilizadores efectivamente beneficiam das funcionalidades apresentadas: ▪ Pois estas permitem que os utilizadores naveguem eficientemente sobre os repositórios de informação; ▪ O fosso entre as conceptualizações dos diferentes intervenientes é minimizado; ▪ Os utilizadores conseguem responder a questões complexas que não conseguiam responder com os sistemas tradicionais. Em suma, este documento apresenta uma proposta que comprovadamente permite, de forma orientada pelo utilizador, responder a questões complexas em repositórios semiestruturados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New PVC membrane electrodes for the determination of sulfadiazine (SDZ) are presented. The electrodes are fabricated with conventional and tubular configurations with a graphite-based electrical contact, and no internal reference solution. The selective membranes consist of bis(triphenylphosphoranilidene)ammonium·SDZ (electrode A), tetraoctylammonium bromide (electrode B), or iron(II)-phthalocyanine (FePC) (electrode C) electroactive materials dispersed in a PVC matrix of o-nitrophenyl octyl ether (o-NPOE) plasticizer. The sensors A, B, and C displayed linear responses over the concentration ranges 1.0*10-2 – 1.0*10–5, 1.0*10–2 – 7.5*10–6, and 3.2*10–2 – 7.0* 10–6 mol l–1 (detection limits of 1.09, 2.04 and 0.87 mg ml–1) with anionic slopes of –57.3 ± 0.1, –46.7 ± 0.5, and –65.1 ± 0.2 mV decade–1, respectively. No effect from pH was observed within 4.0 – 5.5, 4.8 – 10, and 4.5 – 8, respectively, and good selectivity was found. The sensors were applied to the analysis of pharmaceuticals and biological fluids in steady state and in flow conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main goal of this research study was the removal of Cu(II), Ni(II) and Zn(II) from aqueous solutions using peanut hulls. This work was mainly focused on the following aspects: chemical characterization of the biosorbent, kinetic studies, study of the pH influence in mono-component systems, equilibrium isotherms and column studies, both in mono and tri-component systems, and with a real industrial effluent from the electroplating industry. The chemical characterization of peanut hulls showed a high cellulose (44.8%) and lignin (36.1%) content, which favours biosorption of metal cations. The kinetic studies performed indicate that most of the sorption occurs in the first 30 min for all systems. In general, a pseudo-second order kinetics was followed, both in mono and tri-component systems. The equilibrium isotherms were better described by Freundlich model in all systems. Peanut hulls showed higher affinity for copper than for nickel and zinc when they are both present. The pH value between 5 and 6 was the most favourable for all systems. The sorbent capacity in column was 0.028 and 0.025 mmol g-1 for copper, respectively in mono and tri-component systems. A decrease of capacity for copper (50%) was observed when dealing with the real effluent. The Yoon-Nelson, Thomas and Yan’s models were fitted to the experimental data, being the latter the best fit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Specific marine macro algae species abundant at the Portuguese coast (Laminaria hyperborea, Bifurcaria bifurcata, Sargassum muticum and Fucus spiralis) were shown to be effective for removing toxic metals (Cd(II), Zn(II) and Pb(II)) from aqueous solutions. The initial metal concentrations in solution were about 75–100 mg L−1. The observed biosorption capacities for cadmium, zinc and lead ions were in the ranges of 23.9–39.5, 18.6–32.0 and 32.3–50.4 mg g−1, respectively. Kinetic studies revealed that the metal uptake rate was rather fast, with 75% of the total amount occurring in the first 10 min for all algal species. Experimental data were well fitted by a pseudo-second order rate equation. The contribution of internal diffusion mechanism was significant only to the initial biosorption stage. Results indicate that all the studied macro algae species can provide an efficient and cost-effective technology for eliminating heavy metals from industrial effluents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiotherapy (RT) is one of the most important approaches in the treatment of cancer and its performance can be improved in three different ways: through the optimization of the dose distribution, by the use of different irradiation techniques or through the study of radiobiological initiatives. The first is purely physical because is related to the physical dose distributiuon. The others are purely radiobiological because they increase the differential effect between the tumour and the health tissues. The Treatment Planning Systems (TPS) are used in RT to create dose distributions with the purpose to maximize the tumoral control and minimize the complications in the healthy tissues. The inverse planning uses dose optimization techniques that satisfy the criteria specified by the user, regarding the target and the organs at risk (OAR’s). The dose optimization is possible through the analysis of dose-volume histograms (DVH) and with the use of computed tomography, magnetic resonance and other digital image techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of -0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. -0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0x10-6 to 9.0x10-6 mol L-1; this corresponded to a detection limit of 3.5x10-8 mol L-1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conferência - 16th International Symposium on Wireless Personal Multimedia Communications (WPMC)- Jun 24-27, 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research work aims to study the use of peanut hulls, an agricultural and food industry waste, for copper and lead removal through equilibrium and kinetic parameters evaluation. Equilibrium batch studies were performed in a batch adsorber. The influence of initial pH was evaluated (3–5) and it was selected between 4.0 and 4.5. The maximum sorption capacities obtained for the Langmuir model were 0.21 ± 0.03 and 0.18 ± 0.02 mmol/g, respectively for copper and lead. In bi-component systems, competitive sorption of copper and lead was verified, the total amount adsorbed being around 0.21 mmol of metal per gram of material in both mono and bi-component systems. In the kinetic studies equilibrium was reached after 200 min contact time using a 400 rpm stirring rate, achieving 78% and 58% removal, in mono-component system, for copper and lead respectively. Their removal follows a pseudo-second-order kinetics. These studies show that most of the metals removal occurred in the first 20 min of contact, which shows a good uptake rate in all systems.