995 resultados para Computer tomography angiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid response to : Madan M Rehani and Manorma Berry Radiation doses in computed tomography BMJ 2000; 320: 593-594

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate choroidal vascular abnormalities in peripheral exudative hemorrhagic chorioretinopathy, using dynamic ultrawide-field fluorescein angiography (FA) and indocyanine green angiography (ICGA).¦DESIGN: Prospective observational case series.¦METHODS: This institutional study comprised a consecutive series of 40 patients (48 eyes) with peripheral exudative hemorrhagic chorioretinopathy. Choroidal vascular abnormalities were assessed with dynamic ultrawide-field (150-degree) FA and ICGA, using the Staurenghi 230 SLO Retina Lens and the Heidelberg scanning laser ophthalmoscope. The main outcome measures were morphologic descriptions of structural vascular abnormalities and choroidal hemodynamics (comparison with 30 normal eyes).¦RESULTS: The peripheral mass lesions were highly exudative and hemorrhagic, and usually associated with a pigment epithelium detachment. FA revealed nonspecific alterations corresponding to the visible fundoscopic changes (window defects, blockage, staining), but no neovascular membrane. However, despite frequent masking, ICGA showed hyperfluorescent polyp-like structures in the choroid of the lesion area in 33 eyes (69%) and an abnormal choroidal vascular network in 24 eyes (50%). The abnormal choroidal vascular network filled in the arterial or early venous phase, while the polyp-like structures filled some seconds later. Optical coherence tomography revealed the typical dome-shaped elevation of the pigment epithelium over the vascular polyps. Peripheral choriocapillaris closure was observed as well as dilated shunting vessels.¦CONCLUSION: Peripheral exudative hemorrhagic chorioretinopathy shares many characteristics (polyp-like choroidal telangiectases, abnormal choroidal vascular networks, exudative and hemorrhagic presentation) with polypoidal choroidal vasculopathy. Clarification of the precise role of these abnormalities requires further studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The indications for urgent coronary angiography are stated in the guidelines for treatment of acute coronary syndromes. An invasive approach is considered the treatment of choice for patients presenting with ST elevation myocardial infarction within 12 hours of the beginning of symptoms. In the absence of contraindication, intravenous thrombolysis continues to be a valuable alternative to primary angioplasty within 3 hours of the beginning of clinical symptoms. Urgent coronary angiography continues to be recommended following the failure of thrombolysis, persistent myocardial ischemia after 12 hours of symptoms, recurrent myocardial ischemia following myocardial infarction or in the case of cardiogenic shock.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differential X-ray phase-contrast tomography (DPCT) refers to a class of promising methods for reconstructing the X-ray refractive index distribution of materials that present weak X-ray absorption contrast. The tomographic projection data in DPCT, from which an estimate of the refractive index distribution is reconstructed, correspond to one-dimensional (1D) derivatives of the two-dimensional (2D) Radon transform of the refractive index distribution. There is an important need for the development of iterative image reconstruction methods for DPCT that can yield useful images from few-view projection data, thereby mitigating the long data-acquisition times and large radiation doses associated with use of analytic reconstruction methods. In this work, we analyze the numerical and statistical properties of two classes of discrete imaging models that form the basis for iterative image reconstruction in DPCT. We also investigate the use of one of the models with a modern image reconstruction algorithm for performing few-view image reconstruction of a tissue specimen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Accurate assessment of glenoid inclination is of interest for a variety of conditions and procedures. The purpose of this study was to develop an accurate and reproducible measurement for glenoid inclination on standardized anterior-posterior (AP) radiographs and on computed tomography (CT) images. MATERIALS AND METHODS: Three consistently identifiable angles were defined: Angle α by line AB connecting the superior and inferior glenoid tubercle (glenoid fossa) and the line identifying the scapular spine; angle β by line AB and the floor of the supraspinatus fossa; angle γ by line AB and the lateral margin of the scapula. Experimental study: these 3 angles were measured in function of the scapular position to test their resistance to rotation. Conventional AP radiographs and CT scans were acquired in extension/flexion and internal/external rotation in a range up to ±40°. Clinical study: the inter-rater reliability of all angles was assessed on AP radiographs and CT scans of 60 patients (30 with proximal humeral fractures, 30 with osteoarthritis) by 2 independent observers. RESULTS: The experimental study showed that angle α and β have a resistance to rotation of up to ±20°. The deviation from neutral position was not more than ±10°. The results for the inter-rater reliability analyzed by Bland-Altman plots for the angle β fracture group were (mean ± standard deviation) -0.1 ± 4.2 for radiographs and -0.3 ± 3.3 for CT scans; and for the osteoarthritis group were -1.2 ± 3.8 for radiographs and -3.0 ± 3.6 for CT scans. CONCLUSION: Angle β is the most reproducible measurement for glenoid inclination on conventional AP radiographs, providing a resistance to positional variability of the scapula and a good inter-rater reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Long occlusions in calcified crural arteries are a major cause of endovascular technical failure in patients with critical limb ischaemia. Therefore, distal bypasses are mainly performed in patients with heavily calcified arteries and with consequently delicate clamping. A new reverse thermosensitive polymer (RTP) is an alternative option to occlude target vessels. The aim of the study is to report our technical experience with RTP and to assess its safety and efficiency to temporarily occlude small calcified arteries during anastomosis time. METHODS: Between July 2010 and December 2011, we used RTP to occlude crural arteries in 20 consecutive patients with 20 venous distal bypasses. We recorded several operative parameters, such as volume of injected RTP, duration of occlusion and anastomotic time. Quality of occlusion was subjectively evaluated. Routine on-table angiography was performed to search for plug emboli. Primary patency, limb salvage and survival rates were reported at 6 months. RESULTS: In all patients, crural artery occlusion was achieved with the RTP without the use of an adjunct occlusion device. Mean volume of RTP used was 0.3 ml proximally and 0.25 ml distally. Mean duration of occlusion was 14.4 ± 4.5 min, while completion of the distal anastomosis lasted 13.4 ± 4.3 min. Quality of occlusion was judged as excellent in eight cases and good in 12 cases. Residual plugs were observed in two patients and removed with an embolectomy catheter, before we amended the technique for dissolution of RTP. At 6 months, primary patency rate was 75% but limb salvage rate was 87.5%. The 30-day mortality rate was 10%. CONCLUSIONS: This study shows that RTP is safe when properly dissolved and effective to occlude small calcified arteries for completion of distal anastomosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to compare coronary magnetic resonance angiography (MRA) data obtained with different scanning methodologies, adequate visualization and presentation of the coronary MRA data need to be ensured. Furthermore, an objective quantitative comparison between images acquired with different scanning methods is desirable. To address this need, a software tool ("Soap-Bubble") that facilitates visualization and quantitative comparison of 3D volume targeted coronary MRA data was developed. In the present implementation, the user interactively specifies a curved subvolume (enclosed in the 3D coronary MRA data set) that closely encompasses the coronary arterial segments. With a 3D Delaunay triangulation and a parallel projection, this enables the simultaneous display of multiple coronary segments in one 2D representation. For objective quantitative analysis, frequently explored quantitative parameters such as signal-to-noise ratio (SNR); contrast-to-noise ratio (CNR); and vessel length, sharpness, and diameter can be assessed. The present tool supports visualization and objective, quantitative comparisons of coronary MRA data obtained with different scanning methods. The first results obtained in healthy adults and in patients with coronary artery disease are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been convincingly argued that computer simulation modeling differs from traditional science. If we understand simulation modeling as a new way of doing science, the manner in which scientists learn about the world through models must also be considered differently. This article examines how researchers learn about environmental processes through computer simulation modeling. Suggesting a conceptual framework anchored in a performative philosophical approach, we examine two modeling projects undertaken by research teams in England, both aiming to inform flood risk management. One of the modeling teams operated in the research wing of a consultancy firm, the other were university scientists taking part in an interdisciplinary project experimenting with public engagement. We found that in the first context the use of standardized software was critical to the process of improvisation, the obstacles emerging in the process concerned data and were resolved through exploiting affordances for generating, organizing, and combining scientific information in new ways. In the second context, an environmental competency group, obstacles were related to the computer program and affordances emerged in the combination of experience-based knowledge with the scientists' skill enabling a reconfiguration of the mathematical structure of the model, allowing the group to learn about local flooding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The purpose of this contribution is to report our functional results on the efficacy of intravitreal ranibizumab for submacular choroidal neovessels (CNV) in high myopia, and to compare the roles of optical coherence tomography (OCT), fluorescein angiography and visual acuity changes in the treatment decision prior to each injection. Patients and Methods: This is a retrospective study performed in Jules Gonin Eye Hospital. It included all patients with myopic CNV treated with intravitreal ranibizumab injections with a minimum follow-up of 24 months. After an induction dosing from 1 to 3 injections, the follow-up was based on a pro re nata regimen. Ophthalmic evaluation, best corrected visual acuity, and OCT were done at each visit, and fluorescein angiography at baseline and if neovascular activity was suspected. Retreatment criteria included metamorphopsia, visual loss of ≥ 5 ETDRS letters, any fluid on OCT and/or leakage on fluorescein angiography. Results: 24 eyes were included in the study. Mean follow-up was 49 months. Mean visual acuity improved significantly from 62.8 ± 13.8 letters at baseline to 72.8 ± 12.9 letters at last follow-up visit (p = 0.001). The mean number of injections was 2.2 in the first year and below 1 for the following years. The sensitivities of fluorescein angiography, SD OCT, and visual acuity loss ≥ 5 letters were 62.6 %, 51.4 %, and 40 %, respectively. The fluorescein angiography showed a significantly higher sensitivity in treatment decision than OCT (p = 0.007). Conclusion: Our study has shown that ranibizumab injections provide a significant long-term visual benefit in myopic CNV with a small number of injections. Fluorescein angiography has a preponderant role in the treatment decision of active myopic CNV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. MATERIALS AND METHODS: The carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of ∼4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. RESULTS: Using hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times ≥ 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in ≤ 2 min. CONCLUSION: Nonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution. J. Magn. Reson. Imaging 2015;41:1150-1156. © 2014 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo (MC) simulations have been used to study the structure of an intermediate thermal phase of poly(R-octadecyl ç,D-glutamate). This is a comblike poly(ç-peptide) able to adopt a biphasic structure that has been described as a layered arrangement of backbone helical rods immersed in a paraffinic pool of polymethylene side chains. Simulations were performed at two different temperatures (348 and 363 K), both of them above the melting point of the paraffinic phase, using the configurational bias MC algorithm. Results indicate that layers are constituted by a side-by-side packing of 17/5 helices. The organization of the interlayer paraffinic region is described in atomistic terms by examining the torsional angles and the end-to-end distances for the octadecyl side chains. Comparison with previously reported comblike poly(â-peptide)s revealed significant differences in the organization of the alkyl side chains.