965 resultados para Chromatographic Assay
Resumo:
PURPOSE: Conventional staging methods are inadequate to identify patients with stage II colon cancer (CC) who are at high risk of recurrence after surgery with curative intent. ColDx is a gene expression, microarray-based assay shown to be independently prognostic for recurrence-free interval (RFI) and overall survival in CC. The objective of this study was to further validate ColDx using formalin-fixed, paraffin-embedded specimens collected as part of the Alliance phase III trial, C9581.
PATIENTS AND METHODS: C9581 evaluated edrecolomab versus observation in patients with stage II CC and reported no survival benefit. Under an initial case-cohort sampling design, a randomly selected subcohort (RS) comprised 514 patients from 901 eligible patients with available tissue. Forty-nine additional patients with recurrence events were included in the analysis. Final analysis comprised 393 patients: 360 RS (58 events) and 33 non-RS events. Risk status was determined for each patient by ColDx. The Self-Prentice method was used to test the association between the resulting ColDx risk score and RFI adjusting for standard prognostic variables.
RESULTS: Fifty-five percent of patients (216 of 393) were classified as high risk. After adjustment for prognostic variables that included mismatch repair (MMR) deficiency, ColDx high-risk patients exhibited significantly worse RFI (multivariable hazard ratio, 2.13; 95% CI, 1.3 to 3.5; P < .01). Age and MMR status were marginally significant. RFI at 5 years for patients classified as high risk was 82% (95% CI, 79% to 85%), compared with 91% (95% CI, 89% to 93%) for patients classified as low risk.
CONCLUSION: ColDx is associated with RFI in the C9581 subsample in the presence of other prognostic factors, including MMR deficiency. ColDx could be incorporated with the traditional clinical markers of risk to refine patient prognosis.
Resumo:
Background: Sepsis can lead to multiple organ failure and death. Timely and appropriate treatment can reduce in-hospital mortality and morbidity. Objectives: To determine the clinical effectiveness and cost-effectiveness of three tests [LightCycler SeptiFast Test MGRADE® (Roche Diagnostics, Risch-Rotkreuz, Switzerland); SepsiTest™ (Molzym Molecular Diagnostics, Bremen, Germany); and the IRIDICA BAC BSI assay (Abbott Diagnostics, Lake Forest, IL, USA)] for the rapid identification of bloodstream bacteria and fungi in patients with suspected sepsis compared with standard practice (blood culture with or without matrix-absorbed laser desorption/ionisation time-offlight mass spectrometry). Data sources: Thirteen electronic databases (including MEDLINE, EMBASE and The Cochrane Library) were searched from January 2006 to May 2015 and supplemented by hand-searching relevant articles. Review methods: A systematic review and meta-analysis of effectiveness studies were conducted. A review of published economic analyses was undertaken and a de novo health economic model was constructed. A decision tree was used to estimate the costs and quality-adjusted life-years (QALYs) associated with each test; all other parameters were estimated from published sources. The model was populated with evidence from the systematic review or individual studies, if this was considered more appropriate (base case 1). In a secondary analysis, estimates (based on experience and opinion) from seven clinicians regarding the benefits of earlier test results were sought (base case 2). A NHS and Personal Social Services perspective was taken, and costs and benefits were discounted at 3.5% per annum. Scenario analyses were used to assess uncertainty. Results: For the review of diagnostic test accuracy, 62 studies of varying methodological quality were included. A meta-analysis of 54 studies comparing SeptiFast with blood culture found that SeptiFast had an estimated summary specificity of 0.86 [95% credible interval (CrI) 0.84 to 0.89] and sensitivity of 0.65 (95% CrI 0.60 to 0.71). Four studies comparing SepsiTest with blood culture found that SepsiTest had an estimated summary specificity of 0.86 (95% CrI 0.78 to 0.92) and sensitivity of 0.48 (95% CrI 0.21 to 0.74), and four studies comparing IRIDICA with blood culture found that IRIDICA had an estimated summary specificity of 0.84 (95% CrI 0.71 to 0.92) and sensitivity of 0.81 (95% CrI 0.69 to 0.90). Owing to the deficiencies in study quality for all interventions, diagnostic accuracy data should be treated with caution. No randomised clinical trial evidence was identified that indicated that any of the tests significantly improved key patient outcomes, such as mortality or duration in an intensive care unit or hospital. Base case 1 estimated that none of the three tests provided a benefit to patients compared with standard practice and thus all tests were dominated. In contrast, in base case 2 it was estimated that all cost per QALY-gained values were below £20,000; the IRIDICA BAC BSI assay had the highest estimated incremental net benefit, but results from base case 2 should be treated with caution as these are not evidence based. Limitations: Robust data to accurately assess the clinical effectiveness and cost-effectiveness of the interventions are currently unavailable. Conclusions: The clinical effectiveness and cost-effectiveness of the interventions cannot be reliably determined with the current evidence base. Appropriate studies, which allow information from the tests to be implemented in clinical practice, are required.
Resumo:
This study describes further validation of a previously described Peptide-mediated magnetic separation (PMS)-Phage assay, and its application to test raw cows’ milk for presence of viable Mycobacterium avium subsp. paratuberculosis (MAP). The inclusivity and exclusivity of the PMS-phage assay were initially assessed, before the 50% limit of detection (LOD50) was determined and compared with those of PMS-qPCR (targeting both IS900 and f57) and PMS-culture. These methods were then applied in parallel to test 146 individual milk samples and 22 bulk tank milk samples from Johne’s affected herds. Viable MAP were detected by the PMS-phage assay in 31 (21.2%) of 146 individual milk samples (mean plaque count of 228.1 PFU/50 ml, range 6-948 PFU/50 ml), and 13 (59.1%) of 22 bulk tank milks (mean plaque count of 136.83 PFU/50 ml, range 18-695 PFU/50 ml). In contrast, only 7 (9.1%) of 77 individual milks and 10 (45.4%) of 22 bulk tank milks tested PMS-qPCR positive, and 17 (11.6%) of 146 individual milks and 11 (50%) of 22 bulk tank milks tested PMS-culture positive. The mean 50% limits of detection (LOD50) of the PMS-phage, PMS-IS900 qPCR and PMS-f57 qPCR assays, determined by testing MAP-spiked milk, were 0.93, 135.63 and 297.35 MAP CFU/50 ml milk, respectively. Collectively, these results demonstrate that, in our laboratory, the PMS-phage assay is a sensitive and specific method to quickly detect the presence of viable MAP cells in milk. However, due to its complicated, multi-step nature, the method would not be a suitable MAP screening method for the dairy industry.
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
On-site detection of inoculum of polycyclic plant pathogens could potentially contribute to management of disease outbreaks. A 6-min, in-field competitive immunochromatographic lateral flow device (CLFD) assay was developed for detection of Alternaria brassicae (the cause of dark leaf spot in brassica crops) in air sampled above the crop canopy. Visual recording of the test result by eye provides a detection threshold of approximately 50 dark leaf spot conidia. Assessment using a portable reader improved test sensitivity. In combination with a weather-driven infection model, CLFD assays were evaluated as part of an in-field risk assessment to identify periods when brassica crops were at risk from A. brassicae infection. The weather-driven model overpredicted A. brassicae infection. An automated 7-day multivial cyclone air sampler combined with a daily in-field CLFD assay detected A. brassicae conidia air samples from above the crops. Integration of information from an in-field detection system (CLFD) with weather-driven mathematical models predicting pathogen infection have the potential for use within disease management systems.
Resumo:
Antineoplastic drugs are hazardous chemical agents used mostly in the treatment of patients with cancer, however health professionals that handle and administer these drugs can become exposed and develop DNA damage. Comet assay is a standard method for assessing DNA damage in human biomonitoring and, combined with formamidopyrimidine DNA glycosylase (FPG) enzyme, it specifically detects DNA oxidative damage. The aim of this study was to investigate genotoxic effects in workers occupationally exposed to cytostatics (n = 46), as compared to a control group with no exposure (n = 46) at two Portuguese hospitals, by means of the alkaline comet assay. The potential of the OGG1 Ser326Cys polymorphism as a susceptibility biomarker was also investigated. Exposure was evaluated by investigating the contamination of surfaces and genotoxic assessment was done by alkaline comet assay in peripheral blood lymphocytes. OGG1 Ser326Cys (rs1052133) polymorphism was studied by Real Time PCR. As for exposure assessment, there were 121 (37%) positive samples out of a total of 327 samples analysed from both hospitals. No statistically significant differences (Mann-Whitney test, p > 0.05) were found between subjects with and without exposure, regarding DNA damage and oxidative DNA damage, nevertheless the exposed group exhibited higher values. Moreover, there was no consistent trend regarding the variation of both biomarkers as assessed by comet assay with OGG1 polymorphism. Our study was not statistically significant regarding occupational exposure to antineoplastic drugs and genetic damage assessed by comet assay. However, health professionals should be monitored for risk behaviour, in order to ensure that safety measures are applied and protection devices are used correctly.
Resumo:
Antineoplastic drugs are a heterogeneous group of chemicals used in the treatment of cancer, and have been proved by IARC to be mutagens, carcinogens and teratogens agents. In general, chemicals that interact directly with DNA by biding covalently or by intercalating, or indirectly by interfering with DNA synthesis, were among the first chemotherapeutics developed. Also, these drugs can induce reactive oxygen species that can lead to DNA damage and, consequently, mutations. These drugs are often used in combination to achieve synergistic effects on tumour cells resulting from their differing modes of action. However, most if not all of these chemical agents are generally nonselective and, along with tumour cells, normal cells may undergo cytotoxic/genotoxic damage. The in vivo exposure to antineoplastic drugs has been shown to induce different types of lesions in DNA, depending on the particular stage of cell cycle at the time of treatment. Besides the patients that use these drugs as a treatment, workers that handle and/or administer these drugs can be exposed to these substances; namely pharmacy, and nursing personnel in hospital context.
Resumo:
This is an abstract of a presented talk at the European Biotechnology Conference held in Latvia during 05–07 May 2016
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica
Resumo:
Styrene is a building-block of several compounds used in a wide array of materials and products. The most important human exposure to this substance occurs in industrial settings, especially among reinforced-plastics industry workers. The effect of occupational exposure to styrene on cytogenetics biomarkers has been previously reviewed with positive association observed for chromosomal aberrations, and inconclusive data for the micronucleus assay. Some limitations were noted in those studies, including inadequate exposure assessment and poor epidemiological design. Furthermore, in earlier studies micronuclei frequency was measured with protocols not as reliable as cytokinesis-block micronucleus (CBMN) assay. Aim of the present systematic review and meta-analysis is to investigate genomic instability and DNA damage as measured by the CBMN assay in lymphocytes of subjects exposed to styrene. A total of 11 studies published between 2004 and 2012 were included in the meta-analysis encompassing 479 styrene-exposed workers and 510 controls. The quality of each study was estimated by a quality scoring system which ranked studies according to the consideration of major confounders, exposure characterization, and technical parameters. An overall increase of micronuclei frequencies was found in styrene-exposure workers when compared to referents (meta-MR 1.34; 95% CI 1.18–1.52), with significant increases achieved in six individual studies. The consistency of results in individual studies, the independence of this result from major confounding factors and from the quality of the study strengthens the reliability of risk estimates and supports the use of the CBMN assay in monitoring genetic risk in styrene workers.
Resumo:
Tropical Australian shark fisheries target two morphologically indistinguishable blacktip sharks, the Australian blacktip (Carcharhinus tilstoni) and the common blacktip (C. limbatus). Their relative contributions to northern and eastern Australian coastal fisheries are unclear because of species identification difficulties. The two species differ in their number of precaudal vertebrae, which is difficult and time consuming to obtain in the field. But, the two species can be distinguished genetically with diagnostic mutations in their mitochondrial DNA ND4 gene. A third closely related sister species, the graceful shark C. amblyrhynchoides, can also be distinguished by species-specific mutations in this gene. DNA sequencing is an effective diagnostic tool, but is relatively expensive and time consuming. In contrast, real-time high-resolution melt (HRM) PCR assays are rapid and relatively inexpensive. These assays amplify regions of DNA with species-specific genetic mutations that result in PCR products with unique melt profiles. A real-time HRM PCR species-diagnostic assay (RT-HRM-PCR) has been developed based on the mtDNA ND4 gene for rapid typing of C. tilstoni, C. limbatus and C. amblyrhynchoides. The assay was developed using ND4 sequences from 66 C. tilstoni, 33. C. limbatus and five C. amblyrhynchoides collected from Indonesia and Australian states and territories; Western Australia, the Northern Territory, Queensland and New South Wales. The assay was shown to be 100% accurate on 160 unknown blacktip shark tissue samples by full mtDNA ND4 sequencing.
Resumo:
Synthetic cannabinoid receptor agonists or more commonly known as synthetic cannabinoids (SCs) were originally created to obtain the medicinal value of THC but they are an emerging social problem. SCs are mostly produced coated on herbal materials or in powder form and marketed under a variety of brand names, e.g. “Spice”, “K2”. Despite many SCs becoming controlled under drug legislation, many of them remain legal in some countries around the world. In Scotland, SCs are controlled under the Misuse of Drugs Act 1971 and Psychoactive Substances Act 2016 that only cover a few early SCs. In Saudi Arabia, even fewer are controlled. The picture of the SCs-problem in Scotland is vague due to insufficient prevalence data, particularly that using biological samples. Whilst there is evidence of increasing use of SCs throughout the world, in Saudi Arabia, there is currently no data regarding the use of products containing SCs among Saudi people. Several studies indicate that SCs may cause serious toxicity and impairment to health therefore it is important to understand the scale of use within society. A simple and sensitive method was developed for the simultaneous analysis of 10 parent SCs (JWH-018, JWH-073, JWH-250, JWH-200, AM-1248, UR-144, A-796260, AB-FUBINACA, 5F-AKB-48 and 5F-PB-22) in whole blood and 8 corresponding metabolites (JWH-018 4-OH pentyl, JWH-073 3-OH butyl, JWH-250 4-OH pentyl, AM-2201 4-OH pentyl, JWH-122 5-OH pentyl, JWH-210 5-OH pentyl, 5F-AKB-48 (N-4 OH pentyl), 5F-PB-22 3-carboxyindole)in urine using LLE and LC-MS/MS. The method was validated according to the standard practices for method validation in forensic toxicology (SWGTOX, May 2013). All analytes gave acceptable precision, linearity and recovery for analysing blood and urine samples. The method was applied to 1,496 biological samples, a mixture of whole blood and urine. Blood and/or urine samples were analysed from 114 patients presenting at Accident and Emergency in Glasgow Royal Infirmary, in spring 2014 and JuneDecember 2015. 5F-AKB-48, 5F-PB-22 and MDMB-CHMICA were detected in 9, 7 and 9 cases respectively. 904 urine samples from individuals admitted to/liberated from Scottish prisons over November 2013 were tested for the presence of SCs. 5F-AKB-48 (N-4 OH pentyl) was detected in 10 cases and 5F-PB-22 3-carboxyindole in 3 cases. Blood and urine samples from two post-mortem cases in Scotland with suspected ingestion of SCs were analysed. Both cases were confirmed positive for 5F-AKB-48. A total of 463 urine samples were collected from personnel who presented to the Security Forces Hospital in Ryiadh for workplace drug testing as a requirement for their job during July 2014. The results of the analysis found 2 samples to be positive for 5F-PB-22 3carboxyindole. A further study in Saudi Arabia using a questionnaire was carried out among 3 subpopulations: medical professionals, members of the public in and around smoking cafes and known drug users. With regards to general awareness of Spice products, 16%, 11% and 22% of those participants of medical professionals, members of the public in and around smoking cafes and known drug users, respectively, were aware of the existence of SCs or Spice products. The respondents had an overall average of 4.5% who had a friend who used these Spice products. It is clear from the results obtained in both blood and urine testing and surveys that SCs are being used in both Scotland and Saudi Arabia. The extent of their use is not clear and the data presented here is an initial look into their prevalence. Blood and urine findings suggest changing trends in SC use, moving away from JWH and AM SCs to the newer 5F-AKB-48, 5-F-PB-22 and MDMBCHMICA compounds worldwide. In both countries 5F-PB-22 was detected. These findings clarify how the SCs phenomenon is a worldwide problem and how the information of every country regarding what SCs are seized can help and is not specific for that country. The analytes included in the method were selected due to their apparent availability in both countries, however it is possible that some newer analytes have been used and these would not have been detected. For this reason it is important that methods for testing SCs are updated regularly and evolve with the ever-changing availability of these drugs worldwide. In addition, there is little published literature regarding the concentrations of these drugs found in blood and urine samples and this work goes some way towards understanding these.