952 resultados para CLOSED TIMELIKE CURVES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Mini-Mental State Examination (MMSE) is the most widely used instrument for the screening of cognitive impairment worldwide, but its ability to produce valid estimates of dementia in populations of low socioeconomic status and minimal literacy skills has not been adequately established. The authors investigated the psychometric properties of the MMSE in a community-based sample of older Brazilians. Cross-sectional one-phase population-based study of all residents of pre-defined areas of the city of Sao Paulo, aged 65 years or over. The Brazilian version of the MMSE was compared with DSM-IV diagnosis of dementia assessed with a harmonized one-phase procedure developed by the 10/66 Dementia Research Group. Analyses were performed with 1,933 participants of the SPAH study. Receiver operating characteristic analysis showed that the MMSE cut-point of 14/15 was associated with 78.7% sensitivity and 77.8% specificity for the diagnosis of dementia amongst participants with no formal education, and the cut-point 17/18 with 91.9% sensitivity and 89.5% specificity for those with at least 1 year of formal education (areas under the curves 0.87 and 0.94, respectively; P = 0.03). Even with these best fitting cut-points, the MMSE estimate of the prevalence of dementia was four times higher than determined by the DSM-IV criteria. Education, age, sex and income influenced MMSE scores, independently of dementia caseness. The MMSE is an adequate tool for screening dementia in older adults with minimum literacy skills, but misclassification is unacceptably high for older adults who are illiterate, which has serious consequences for research and clinical practice in low and middle income countries, where the proportion of illiteracy among older adults is high.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The aims of this study were to analyze the overall survival of patients with cirrhosis and small hepatocellular carcinoma (HCC) and identify independent pretreatment predictors of survival in Brazil. Methods: Between 1998 and 2003, 74 patients with cirrhosis and small HCC were evaluated. Predictors of survival were identified using the Kaplan-Meier survival curves and the Cox model. Results: The overall survival rates were 80%, 41%, and 17% at 12, 36, and 60 months, respectively. The mean length of follow-up after HCC diagnosis was 23 months (median 22 mo, range: I to 86 mo) for the entire group. Univariate analysis showed that model for endstage liver disease (MELD) score (P = 0.016), Child-Pugh classification (P = 0.007), alpha-fetoprotein level (P = 0.006), number of nodules (P = 0.041), tumor diameter (P = 0.009), and vascular invasion (P < 0.0001) were significant predictors Of Survival. Cox regression analysis identified vascular invasion (relative risk = 14.60, confidence interval 95% = 3.3-64.56, P < 0.001) and tumor size > 20 mm (relative risk = 2.14, confidence interval 95% = 1.07-4.2, P = 0.030) as independent predictors of decreased survival. Treatment of HCC was related to increased overall survival. Conclusions: Identification of HCC smaller than 20 mm is associated with longer survival. Presence of vascular invasion, even in small tumors, maybe associated with poor prognosis. Treatment of small tumors Of LIP to 20 mm diameter is related to increased survival.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and objective: Light`s criteria are frequently used to evaluate the exudative or transudative nature of pleural effusions. However, misclassification resulting from the use of Light`s criteria has been reported, especially in the setting of diuretic use in patients with heart failure (HF). The objective of this study was to evaluate the utility of B-type natriuretic peptide (BNP) measurements as a diagnostic tool for determining the cardiac aetiology of pleural effusions. Methods: Patients with pleural effusions attributable to HF (n = 34), hepatic hydrothorax (n = 10), pleural effusions due to cancer (n = 21) and pleural effusions due to tuberculosis (n = 12) were studied. Diagnostic thoracentesis was performed for all 77 patients. Receiver operating characteristic (ROC) curves were constructed to determine the diagnostic accuracy of plasma BNP and pleural fluid BNP for the prediction of HF. Results: The areas under the ROC curves were 0.987 (95% CI 0.93-0.998) for plasma BNP and 0.949 (95% CI 0.874-0.986) for pleural fluid BNP, for distinguishing between patients with pleural effusions caused by HF (n = 34) and those with pleural effusions attributable to other causes (n = 43). The cut-off concentrations with the highest diagnostic accuracy for the diagnosis of HF as the cause of pleural effusion were 132 pg/mL for plasma BNP (sensitivity 97.1%, specificity 97.4%) and 127 pg/mL for pleural fluid BNP (sensitivity 97.1%, specificity 87.8%). Conclusions: In patients with pleural effusions of suspected cardiac origin, measurements of BNP in plasma and pleural fluid may be useful for the diagnosis of HF as the underlying cause.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. METHODS. 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models. RESULTS. Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNLI thickness, and ganglion cell complex-root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs. CONCLUSIONS. Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity. (Invest Ophthalmol Vis Sci. 2011;92:1290-1296) DOI:10.1167/iovs.10-5516

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The Cambridge Cognitive Examination (CAMCOG) is a useful test in screening for Alzheimer`s disease (AD). However, the interpretation of CAMCOG cut-off scores is problematic and reference values are needed for different educational strata. Given the importance of earlier diagnoses of mild dementia, new cut-off values are required which take into account patients with low levels of education. This study aims to evaluate whether the CAMCOG can be used as an accurate screening test among AD patients and normal controls with different educational levels. Methods: Cross-sectional assessment was undertaken of 113 AD and 208 elderly controls with heterogeneous educational levels (group 1: 1-4 years; group 2: 5-8 years; and group 3: >= 9 years) from a geriatric clinic. submitted to a thorough diagnostic evaluation for AD including the Cambridge Examination for Mental Disorders of the Elderly (CAMDEX). Controls had no cognitive or mood complaints. Sensitivity (SE) and specificity (SP) for the CAMCOG in each educational group was assessed with receiver-operator-characteristic (ROC) curves. Results: CAMCOG mean values were lower when education was reduced in both diagnostic groups (controls - group 1: 87; group 2: 91; group 3: 96; AD - group 1: 63; group 2: 62; group 3: 77). Cutoff scores for the three education groups were 79, 80 and 90, respectively. SE and SP varied among the groups (group 1: 88.1% and 83.5%; group 2: 84.6% and 96%; group 3: 70.8% and 90%). Conclusion: The CAMCOG can be used as a cognitive test for patients with low educational level with good accuracy. Patients with higher education showed lower scores than previously reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the challenges in screening for dementia in developing countries is related to performance differences due to educational and cultural factors. This study evaluated the accuracy of single screening tests as well as combined protocols including the Mini-Mental State Examination (MMSE), Verbal Fluency animal category (VF), Clock Drawing test (CDT), and Pfeffer Functional Activities Questionnaire (PFAQ) to discriminate illiterate elderly with and without Alzheimer`s disease (AD) in a clinical sample. Cross-sectional study with 66 illiterate outpatients diagnosed with mild and moderate AD and 40 illiterate normal controls. Diagnosis of AD was based on NINCDS-ADRDA. All patients were submitted to a diagnostic protocol including a clinical interview based on the CAMDEX sections. ROC curves area analyses were carried out to compare sensitivity and specificity for the cognitive tests to differentiate the two groups (each test separately and in two by two combinations). Scores for all cognitive (MMSE, CDT, VF) and functional assessments (PFAQ) were significantly different between the two groups (p < 0.001). The best screening instruments for this sample of illiterate elderly were the MMSE and the PFAQ. The cut-off scores for the MMSE, VF, CDT, and PFAQ were 17.5, 7.5, 2.5, and 11.5, respectively. The most sensitive combination came from the MMSE and PFAQ (94.1%), and the best specificity was observed with the combination of the MMSE and CDT (89%). Illiterate patients can be successfully screened for AD using well-known screening instruments, especially in combined protocols.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the gain in strength and range of motion after modified Steindler surgery of the elbow in patients with lesions of the upper trunk of the brachial plexus. Method: From 1998 to 2007, eleven patients with traumatic closed upper trunk lesion of the brachial plexus were studied. All the patients had development of at least 1 year of injury and degree of strength of elbow flexion ranging from M1 to M3. The patients underwent Steindler surgery with at least 6 months of follow-up. Pre- and post-operative assessments were carried out to determine gain in muscle strength, range of motion of the elbow, and DASH scale score. Results: Of the eleven patients studied, nine (82%) achieved a level of strength equal to or greater than M3 (MRC) with good functional recovery. Two (18%) reached strength level M2 (MRC). We observed that the patients had an average postoperative gain in range of motion of the elbow of 43.45 degrees. The average elbow flexion after surgery was 88 degrees. There was an improvement in elbow function, as demonstrated in the DASH Scale, in 81% of the patients studied. Conclusion: Modified Steindler surgery was effective in the treatment of patients with injuries of the upper trunk of the brachial plexus, with statistically significant gains in range of motion. In all the cases studied, there was some degree of gain in strength and range of elbow flexion, the gain being correlated with the initial muscle strength. Level of Evidence: Level II, prospective clinical trial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: To evaluate the cardiopulmonary effects of positive end-expiratory pressure (PEEP) equalization to intra-abdominal pressure (IAP) in an experimental model of intra-abdominal hypertension (IAH) and acute lung injury (ALI). Methods: Eight anesthetized pigs were submitted to IAH of 20 mm Hg with a carbon dioxide insufflator for 30 minutes and then submitted to lung lavage with saline and Tween (2.5%). Pressure x volume curves of the respiratory system were performed by a low flow method during IAH and ALI, and PEEP was subsequently adjusted to 27 cm center dot H(2)O for 30 minutes. Results: IAH decreases pulmonary and respiratory system static compliances and increases airway resistance, alveolar-arterial oxygen gradient, and respiratory dead space. The presence of concomitant ALI exacerbates these findings. PEEP identical to AP moderately improved oxygenation and respiratory mechanics; however, an important decline in stroke index and right ventricle ejection fraction was observed. Conclusions: Simultaneous IAH and ALI produce important impairments in the respiratory physiology. PEEP equalization to AP may improve the respiratory performance, nevertheless with a secondary hemodynamic derangement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS. One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The severity of the disease was graded based on the visual field index (VFI) from standard automated perimetry. Imaging of the retinal nerve fiber layer (RNFL) was obtained using the optic disc cube protocol available on the Cirrus HD-OCT. Pooled receiver operating characteristic (ROC) curves were initially obtained for each parameter of the Cirrus HD-OCT. The effect of disease severity on diagnostic performance was evaluated by fitting an ROC regression model, with VFI used as a covariate, and calculating the area under the ROC curve (AUCs) for different levels of disease severity. RESULTS. The largest pooled AUCs were for average thickness (0.892), inferior quadrant thickness (0.881), and superior quadrant thickness (0.874). Disease severity had a significant influence on the detection of glaucoma. For the average RNFL thickness parameter, AUCs were 0.962, 0.932, 0.886, and 0.822 for VFIs of 70%, 80%, 90%, and 100%, respectively. CONCLUSIONS. Disease severity had a significant effect on the diagnostic performance of the Cirrus HD-OCT and thus should be considered when interpreting results from this device and when considering the potential applications of this instrument for diagnosing glaucoma in the various clinical settings. (Invest Ophthalmol Vis Sci. 2010;51:4104-4109) DOI:10.1167/iovs.094716

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate and compare rates of change in neuro-retinal rim area (RA) and retinal nerve fiber layer thickness (RNFLT) measurements in glaucoma patients, those with suspected glaucoma, and normal subjects observed over time. METHODS. In this observational cohort study, patients recruited from two longitudinal studies (Diagnostic Innovations in Glaucoma Study-DIGS and African Descent and Evaluation Study-ADAGES) were observed with standard achromatic perimetry (SAP), optic disc stereophotographs, confocal scanning laser ophthalmoscopy (HRT-3; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx-VCC; Carl Zeiss Meditec, Inc., Dublin, CA). Glaucoma progression was determined by the Guided Progression Analysis software for standard automated perimetry [SAP] and by masked assessment of serial optic disc stereophotographs by expert graders. Random-coefficients models were used to evaluate rates of change in average RNFLT and global RA measurements and their relationship with glaucoma progression. RESULTS. At baseline, 194 (31%) eyes were glaucomatous, 347 (55%) had suspected glaucoma, and 88 (14%) were normal. Forty-six (9%) eyes showed progression by SAP and/or stereophotographs, during an average follow-up of 3.3 (+/-0.7) years. The average rate of decline for RNFLT measurements was significantly higher in the progressing group than in the non-progressing group (-0.65 vs. -0.11 mu m/y, respectively; P < 0.001), whereas RA decline was not significantly different between these groups (-0.0058 vs. -0.0073 mm(2)/y, respectively; P = 0.727). The areas under the receiver operating characteristic (ROC) curves used to discriminate progressing versus nonprogressing eyes were 0.811 and 0.507 for the rates of change in the RNFLT and RA, respectively (P < 0.001). CONCLUSIONS. The ability to discriminate eyes with progressing glaucoma by SAP and/or stereophotographs from stable eyes was significantly greater for RNFLT than for RA measurements. (Invest Ophthalmol Vis Sci. 2010;51:3531-3539) DOI: 10.1167/iovs.09-4350

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: to describe women`s feelings about mode of birth. Design: exploratory descriptive design. Semi-structured interviews were conducted using a questionnaire that had been developed previously (categorical data and open-and closed-ended questions). Qualitative analysis of the results was performed through a context analysis technique. Setting: the largest public university hospital in Brazil. Participants: 48 women in their third trimester of pregnancy. Findings: most women expressed a preference for vaginal birth, as they perceived that they would have a faster recovery. Women who expressed a preference for caesarean section did so because of lack of pain during the birth and the need for tubal sterilisation. The majority of women considered it important to have experience with a mode of birth in order to choose a preference. Complications associated with maternal illness were very influential in the decision-making process. Key conclusions: these results provide a useful first step towards the identification of aspects of women`s feelings about modes of birth. Most women expressed a preference for vaginal birth. Further exploration of women`s feelings regarding parturition and the decision-making process is required. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Extensive experimental studies and clinical evidence (Metabolic Efficiency with Ranzolazine for Less Ischemia in Non-ST-Elevation Acute Coronary Syndrome Thrombolysis in Myocardial Infarction-36 [MERLIN TIMI-36] trial) indicate potential antiarrhythmic efficacy of the antianginal agent ranolazine. Delivery of agents into the pericardial space allows high local concentrations to be maintained in close proximity to myocardial tissue while systemic effects are minimized. Methods and Results: The effects of intrapericardial (IPC) administration of ranolazine (50-mg bolus) on right atrial and right ventricular effective refractory periods (ERP), atrial fibrillation threshold, and ventricular fibrillation threshold were determined in 17 closed-chest anesthetized pigs. IPC ranolazine increased atrial ERP in a time-dependent manner from 129 +/- 5.14 to 186 +/- 9.78 ms (P < 0.01, N = 7) but did not significantly affect ventricular ERP (from 188.3 +/- 4.6 to 201 +/- 4.3 ms (NS, N = 6). IPC ranolazine increased atrial fibrillation threshold from 4.8 +/- 0.8 to 28 +/- 2.3 mA (P < 0.03, N = 6) and ventricular fibrillation threshold (from 24 +/- 3.56 baseline to 29.33 +/- 2.04 mA at 10-20 minutes, P < 0.03, N = 6). No significant change in mean arterial pressure was observed (from 92.8 +/- 7.1 to 74.8 +/- 7.5 mm Hg, P < 0.125, N = 5, at 7 minutes). Conclusions: IPC ranolazine exhibits striking atrial antiarrhythmic actions as evidenced by increases in refractoriness and in fibrillation inducibility without significantly altering mean arterial blood pressure. Ranolazine`s effects on the atria appear to be more potent than those on the ventricles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and objective The time course of cardiopulmonary alterations after pulmonary embolism has not been clearly demonstrated and nor has the role of systemic inflammation on the pathogenesis of the disease. This study aimed to evaluate over 12 h the effects of pulmonary embolism caused by polystyrene microspheres on the haemodynamics, lung mechanics and gas exchange and on interleukin-6 production. Methods Ten large white pigs (weight 35-42 kg) had arterial and pulmonary catheters inserted and pulmonary embolism was induced in five pigs by injection of polystyrene microspheres (diameter similar to 300 mu mol l(-1)) until a value of pulmonary mean arterial pressure of twice the baseline was obtained. Five other animals received only saline. Haemodynamic and respiratory data and pressure-volume curves of the respiratory system were collected. A bronchoscopy was performed before and 12 h after embolism, when the animals were euthanized. Results The embolism group developed hypoxaemia that was not corrected with high oxygen fractions, as well as higher values of dead space, airway resistance and lower respiratory compliance levels. Acute haemodynamic alterations included pulmonary arterial hypertension with preserved systemic arterial pressure and cardiac index. These derangements persisted until the end of the experiments. The plasma interleukin-6 concentrations were similar in both groups; however, an increase in core temperature and a nonsignificant higher concentration of bronchoalveolar lavage proteins were found in the embolism group. Conclusion Acute pulmonary embolism induced by polystyrene microspheres in pigs produces a 12-h lasting hypoxaemia and a high dead space associated with high airway resistance and low compliance. There were no plasma systemic markers of inflammation, but a higher central temperature and a trend towards higher bronchoalveolar lavage proteins were found. Eur J Anaesthesiol 27:67-76 (C) 2010 European Society of Anaesthesiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE. The purpose of the study was to investigate patient characteristics associated with image quality and their impact on the diagnostic accuracy of MDCT for the detection of coronary artery stenosis. MATERIALS AND METHODS. Two hundred ninety-one patients with a coronary artery calcification (CAC) score of <= 600 Agatston units (214 men and 77 women; mean age, 59.3 +/- 10.0 years [SD]) were analyzed. An overall image quality score was derived using an ordinal scale. The accuracy of quantitative MDCT to detect significant (>= 50%) stenoses was assessed using quantitative coronary angiography (QCA) per patient and per vessel using a modified 19-segment model. The effect of CAC, obesity, heart rate, and heart rate variability on image quality and accuracy were evaluated by multiple logistic regression. Image quality and accuracy were further analyzed in subgroups of significant predictor variables. Diagnostic analysis was determined for image quality strata using receiver operating characteristic (ROC) curves. RESULTS. Increasing body mass index (BMI) (odds ratio [OR] = 0.89, p < 0.001), increasing heart rate (OR = 0.90, p < 0.001), and the presence of breathing artifact (OR = 4.97, p = 0.001) were associated with poorer image quality whereas sex, CAC score, and heart rate variability were not. Compared with examinations of white patients, studies of black patients had significantly poorer image quality (OR = 0.58, p = 0.04). At a vessel level, CAC score (10 Agatston units) (OR = 1.03, p = 0.012) and patient age (OR = 1.02, p = 0.04) were significantly associated with the diagnostic accuracy of quantitative MDCT compared with QCA. A trend was observed in differences in the areas under the ROC curves across image quality strata at the vessel level (p = 0.08). CONCLUSION. Image quality is significantly associated with patient ethnicity, BMI, mean scan heart rate, and the presence of breathing artifact but not with CAC score at a patient level. At a vessel level, CAC score and age were associated with reduced diagnostic accuracy.