970 resultados para residue coefficient


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles. Methods: Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses. Results: The Cronbach a values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551). Conclusions: The photogrammetric measures were found to be reproducible in this study and could be used as Supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis. (J Manipulative Physiol Ther 2009;32:423-430)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this paper is to study the correlation between the intraocular pressure peaks and fluctuation detected during the water drinking test and the same parameters observed during long-term follow up. This prospective cohort study enrolled 22 eyes of 22 newly diagnosed primary open angle glaucoma patients. After an initial complete ophthalmological examination, patients were started on antiglaucoma medication and returned 4 weeks later to perform the water drinking test. Thereafter, patients were evaluated at least eight times within a period of 6-12 months. The intraocular pressure peaks and fluctuation detected during the water drinking stress test were compared with those observed during regular office visits. Spearman`s correlation coefficient and Bland-Altman Plots were used for statistical analysis. The mean age of participants was 54.3 +/- 8.2 years (+/- SD), 59% were women, and average mean deviation -10.2 +/- 4.5 dB. The mean follow-up period was 8.2 +/- 2.0 months. The average intraocular pressure peaks and fluctuation during the water drinking test were 20.0 +/- 2.9 mmHg and 40 +/- 10%, respectively, and 18.1 +/- 2.8 mmHg and 30 +/- 10% during follow up. Spearman`s correlation coefficients were significant and strong between the intraocular pressure peaks and fluctuation detected during the water drinking test and during the follow-up period (P < 0.001, rho = 0.76 and 0.82, respectively). There was good agreement between the variables. The intraocular pressure peaks and fluctuation detected during the water drinking test showed significant correlation and agreement with the pressures observed during follow-up visits. Stress tests could be used to estimate long-term intraocular pressure variation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Type 1, X-linked Hyper-IgM syndrome (HIGM1) is caused by mutations in the gene encoding the CD154 protein, also known as CD40 ligand (CD40LG). CD40L is expressed in activated T cells and interacts with CD40 receptor expressed on B lymphocytes and dendritic cells. Affected patients present cellular and humoral immune defects, with infections by intracellular, opportunistic and extracellular pathogens. In the present study we investigated the molecular defects underlying disease in four patients with HIGM1. We identified four distinct CD40L mutations, two of them which have not been previously described. P1 harboured the novel p.G227X mutation which abolished CD40L expression. P2 had a previously described frame shift deletion in exon 2 (p.I53fsX65) which also prevented protein expression. P3 demonstrated the previously known p.V126D change in exon 4, affecting the TNF homology (TNFH) domain. Finally, P4 evidenced the novel p.F229L mutation also located in the TNFH domain. In silico analysis of F229L predicted the change to be pathological, affecting the many hydrophobic interactions of this residue. Precise molecular diagnosis in HIGM syndrome allows reliable detection of carriers, making genetic counselling and prenatal diagnosis possible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The Purpose of this study was to determine whether handedness influences bilateral shoulder range of motion in nonathlete adult women. Methods: This was an observational Study. Shoulder range of motion (flexion, abduction, horizontal adduction, extension, external and internal rotation) was passively and bilaterally measured in 50 female, right-handed, and healthy university students, ranging from 20 to 29 years of age, who were not practicing repetitive activities with the upper limbs at the time Of this study. The assessment was performed with a universal goniometer, twice for each subject by the same examiner. irst and second measurements were correlated using the intraclass correlation coefficient, which was high for all movements and ranged from 0.80 to 0.97. The Student t test and Wilcoxon test were used to compare the range of motion between the dominant and nondominant shoulders and the mean differences between the 2 sides. The effect of size vias alpha = .05. Results: There is statistically significance difference between the 2 sides when the rotational range of motion is compared the dominant shoulder presented increased external rotation (mean, 4.74 degrees; 95% confidence interval, 1.61-7.87) and decreased internal rotation (mean, 3.52 degrees; 95% confidence interval, 1.64-5.4) compared to the opposite Shoulder. Conclusion: Dominance should be considered when shoulder rotation is evaluated even in nonathlete adult women. (J Manipulative Physiol Ther 2009;32:149-153)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the identification of a novel mutation at a highly conserved residue within the N-terminal region of spermine synthase (SMS) in a second family with Snyder-Robinson X-linked mental retardation syndrome ( OMIM 309583). This missense mutation, p.G56S, greatly reduces SMS activity and leads to severe epilepsy and cognitive impairment. Our findings contribute to a better delineation and expansion of the clinical spectrum of Snyder-Robinson syndrome, support the important role of the N-terminus in the function of the SMS protein, and provide further evidence for the importance of SMS activity in the development of intellectual processing and other aspects of human development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods. Metallic frameworks (25 mm x 3 mm x 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 mu m aluminum oxide at the central area of the frameworks (8 mm x 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: I mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 degrees C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 degrees C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 degrees C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey`s test (alpha = 0.05). Results. The mean flexural strength values for the ceramic-gold alloy combination (55 +/- 7.2MPa) were significantly higher than those of the ceramic-Ti cp combination (32 +/- 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 +/- 6.6 and 53 +/- 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 +/- 6.8 and 29 +/- 6.8 MPa, respectively) compared to the control group (58 +/- 7.8 and 39 SA MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey`s test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance. Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aimed to assess the reliability of intra and inter-examiner subacromial impingement index (SII) measures obtained from radiographs. Thirty-six individuals were enrolled and divided into two groups: control group, composed of 18 volunteers in good general health without shoulder problems, and a group of 18 patients with subacromial impingement syndrome (SIS). Radiographic images were taken with the dominant upper limb in neutral rotation, while the volunteers held their arm at 90A degrees of abduction in the frontal plane. The beam of radiation at 30A degrees craniocaudal inclination was used to provide an antero-posterior image view. Three blinded examiners each performed three measurements from the subacromial space (SS) and the anatomical neck of the humerus (NH). The SII was calculated as the ratio of the SS and the NH measures. The mean values of SII were compared using t-tests. The intra-class correlation coefficient (ICC) was used to assess intra- and inter-examiner reliability of the measures. The mean values of SII were greater for the control group (0.12) than for the SIS group (0.08; p = 0.0071). SII measurements showed excellent intra (0.96-0.99) and inter-examiner reliability (0.94) for both the control and SIS group. The results of this study show the potential use of the SII; a greater mean value for the control group compared to the SIS group and excellent reliability for intra- and inter-examiner measurement. Validation studies of the index should be conducted to correlate the index with clinical findings from subacromial impingement syndrome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Premature closure of the proximal femoral growth plate results in coxa brevis, which usually is associated with insufficiency of the hip abductors. Distal and lateral transfer of the greater trochanter sometimes is recommended to correct this problem. Most of what is known arises from studies of children and adolescents. We asked whether this procedure in adults with coxa brevis would eliminate hip abductor insufficiency and would improve their hip function based on the Harris hip score (HHS). We prospectively followed 11 patients, aged 19 to 55 years (mean, 40 years) who had distal and lateral trochanteric transfer. All patients had pain and a positive Trendelenburg test before surgery. This test was performed at the latest followup by three observers and the interobserver reliability was determined by the kappa coefficient. The HHS was obtained before surgery and at the latest followup. The minimum followup was 25 months (mean, 52 months; range, 25-77 months). Insufficiency of the hip abductors was eliminated in seven (according to two observers) and eight (according to one observer) of the 11 patients after surgery; the kappa coefficient ranged from 0.79 to 1.0. The mean HHS improved from 64 points preoperatively to 76 points at the final followup. The two patients with preexisting severe osteoarthritis of the hip had the worst final scores and persisted with a positive Trendelenburg test at the final followup. Distal and lateral transfer of the greater trochanter can eliminate insufficiency of the hip abductors and improve joint function in adult patients with coxa brevis and we believe should be considered for patients without severe osteoarthritis of the hip. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new gold(I) complex with 2-mercaptothiazoline (MTZ) with the coordination formula [AuCN(C(3)H(5)NS(2))] was synthesized and characterized by chemical and spectroscopic measurements, OFT studies and biological assays. Infrared (IR) and (1)H, (13)C and (15)N nuclear magnetic resonance (NMR) spectroscopic measurements indicate coordination of the ligand to gold(I) through the nitrogen atom. Studies based on OFT confirmed nitrogen coordination to gold(I) as a minimum of the potential energy surface with calculations of the hessians showing no imaginary frequencies. Thermal decomposition starts at temperatures near 160 degrees C, leading to the formation of Au as the final residue at 1000 degrees C. The gold(I) complex with 2-mercaptothiazoline (Au-MTZ) is soluble in dimethyl sulfoxide (DMSO), and is insoluble in water, methanol, ethanol, acetonitrile and hexane. The antibacterial activities of the Au-MTZ complex were evaluated by an antibiogram assay using the disc diffusion method. The compound showed an effective antibacterial activity against Staphylococcus aureus (Gram-positive) and Escherichia coli and Pseudomonas aeruginosa (Gram-negative) bacterial cells. Biological analysis for evaluation of the cytotoxic effect of the Au-MTZ complex was performed using HeLa cells derived from human cervical adenocarcinoma. The complex presented a potent cytotoxic activity, inducing 85% of cell death at a concentration of 2.0 mu mol L(-1). (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Adequate energy provision and nitrogen losses prevention of critically ill patients are essentials for treatment and recovery. The aims of this study were to evaluate energy expenditure (EE) and nitrogen balance (NB) of critically ill patients, to classify adequacy of energy intake (El), and to verify adequacy of El capacity to reverse the negative NB. Methods: Seventeen patients from an intensive care unit were evaluated within a 24-hour period. Indirect calorimetry was performed to calculate patient`s EE and Kjeldhal for urinary nitrogen analysis. The total El and protein intake were calculated from the standard parenteral and enteral nutrition infused. Underfeeding was characterized as El 90% or less and overfeeding as 110% or greater of EE. The adequacy of the El (El EE(-1) x 100) and the NB were estimated and associated with each other by Spearman coefficient. Results: The mean EE was 1515 +/- 268 kcal d(-1) and most of the patients (11/14) presented a negative NB (-8.2 +/- 4.7 g.d(-1)). A high rate (53%) of inadequate energy intake was found, and a positive correlation between El EE(-1) and NB was observed (r = 0.670; P = .007). Conclusion: The results show a high rate of inadequate El and negative NB, and equilibrium between El and EE may improve NB. Indirect calorimetry can be used to adjust the energy requirements in the critically ill patients. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to obtain and to characterize microemulsions containing 5-aminolevulinic acid (5-ALA) and to investigate the influence of these systems in drug skin permeation for further topical photodynamic therapy (PDT). 5-ALA was incorporated in water-in-oil (W/O), bicontinuous (Bc), and oil-in-water (O/W) microemulsions obtained by the titration of ethyl oleate and PEG-8 caprylic/capric glycerides:polyglyceryl-6 dioleate (3:1) mixtures with water. Selected systems were characterized by conductivity, viscosity, size of the droplets, and drug release. The stability of the drug in the microemulsions was also assessed. Moreover, the in vitro and in vivo skin permeation of 5-ALA was investigated using diffusion cells and confocal scanning laser microscopy (CSLM), respectively. Despite the fact that the O/W microemulsion decreased the 5-ALA diffusion coefficient and retarded the drug release, it also significantly increased the in vitro drug skin permeation when compared to other 5-ALA carriers. It was observed by CSLM that the red fluorescence of the skin increased homogeneously in the deeper skin layers when the 5-ALA microemulsion was applied in vivo, probably due to the formation of the photoactive protoporphyrin IX. The microemulsion developed carried 5-ALA to the deeper skin layers, increasing the red fluorescence of the skin and indicating the potentiality of the system for topical 5-ALA-PDT. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Deficiency of 11 beta-hydroxylase results in the impairment of the last step of cortisol synthesis. In females, the phenotype of this disorder includes different degrees of genital ambiguity and arterial hypertension. Mutations in the CYP11B1 gene are responsible for this disease. Objective: The objective of the study was to screen the CYP11B1 gene for mutations in two unrelated Brazilian females with congenital adrenal hyperplasia due to 11 beta-hydroxylase deficiency. Design: The coding and intron-exon junction regions of CYP11B1 were totally sequenced. A putative splice mutation was further investigated by minigene transcription. Results: We report two novel CYP11B1 mutations in these Brazilian patients. An Arabian Lebanese descendent female was found to be homozygous for a cytosine insertion at the beginning of exon 8, changing the 404 arginine to proline. It alters the open reading frame, creating a putative truncated protein at 421 residue, which eliminates the domain necessary for the association of heme prosthetic group. A severely virilized female was homozygous for the g. 2791G>A transition in the last position of exon 4. This nucleotide is also part of 5` intron 4 donor splice site consensus sequence. Minigene experiments demonstrated that g. 2791G>A activated an alternative splice site within exon 4, leading to a 45-bp deletion in the transcript. The putative translation of such modified mRNA indicates a truncated protein at residue 280. Conclusions: We describe two novel mutations, g. 4671_4672insC and g. 2791G>A, that drastically affects normal protein structure. These mutations abolish normal enzyme activity, leading to a severe phenotype of congenital adrenal hyperplasia due to 11 beta-hydroxylase deficiency. (J Clin Endocrinol Metab 94: 3481-3485, 2009)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We measured the oral and pharyngeal transit of a paste bolus in 20 patients with Chagas` disease and 21 controls. Each subject swallowed of a 10-ml paste bolus prepared with 50 ml of water and 4.5 g of instant food thickener labeled with 55.5 MBq of 99(m) technetium phytate. After the scintigraphic recording of the transit, we delineated regions of interest (ROI) corresponding to mouth, pharynx, and proximal esophagus. Time-activity curves were generated for each ROI. There was no difference between patients with Chagas` disease and controls with respect to the duration of oral and pharyngeal transit, amount of pharyngeal residue, or flux of bolus entry into the proximal esophagus. The amount of oral residue was higher in patients with Chagas` disease (median = 0.71 ml) than in controls (median = 0.45 ml). The pharyngeal clearance duration was longer in patients with Chagas` disease (median = 0.85 s) than in controls (median = 0.60 s). The oral transit duration of the patients with Chagas` disease and dysphagia (median = 0.55 s, n = 14) was shorter than the oral transit duration of chagasic patients without dysphagia (median = 0.80 s, n = 6). We conclude that when swallowing a paste bolus, patients with Chagas` disease may have an increased amount of oral residue and a longer pharyngeal clearance duration than asymptomatic volunteers.