996 resultados para optical-lattice potential


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantum information theory, applied to optical interferometry, yields a 1/n scaling of phase uncertainty Delta phi independent of the applied phase shift phi, where n is the number of photons in the interferometer. This 1/n scaling is achieved provided that the output state is subjected to an optimal phase measurement. We establish this scaling law for both passive (linear) and active (nonlinear) interferometers and identify the coefficient of proportionality. Whereas a highly nonclassical state is required to achieve optimal scaling for passive interferometry, a classical input state yields a 1/n scaling of phase uncertainty for active interferometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ''optical meson'' (two-photon quantum soliton) is proven to exist in a parametric waveguide. This could provide an ideal quantum soliton environment, because of more realistic formation lengths and much larger binding energies than chi((3)) quantum solitons. We estimate the binding energy, radius, and interaction length in comparison to the chi((3)) case in optical fibers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a simulated-annealing-based genetic algorithm for solving model parameter estimation problems. The algorithm incorporates advantages of both genetic algorithms and simulated annealing. Tests on computer-generated synthetic data that closely resemble optical constants of a metal were performed to compare the efficiency of plain genetic algorithms against the simulated-annealing-based genetic algorithms. These tests assess the ability of the algorithms to and the global minimum and the accuracy of values obtained for model parameters. Finally, the algorithm with the best performance is used to fit the model dielectric function to data for platinum and aluminum. (C) 1997 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the synthesis of 3-amino-3-(4-chlorophenyl)propanoic acid and the corresponding phosphonic and sulfonic acids, lower homologues of baclofen, phaclofen and saclofen respectively. The chlorinated acids were all weak specific antagonists of GABA at the GABAB receptor, with the sulfonic acid (pA(2) 4.0) being stronger than the phosphonic acid (pA(2) 3.8) and carboxylic acid (pA(2) 3.5).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential for hedging Australian wheat with the new Sydney Futures Exchange wheat contract is examined using a theoretical hedging model parametised from previous studies. The optimal hedging ratio for an 'average' wheat farmer was found to be zero under reasonable assumptions about transaction costs and based on previously published measures of risk aversion. The estimated optimal hedging ratios were found by simulation to be quite sensitive to assumptions about the degree of risk aversion. If farmers are significantly more risk averse than is currently believed, then there is likely to be an active interest in the new futures market.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider solutions to the second-harmonic generation equations in two-and three-dimensional dispersive media in the form of solitons localized in space and time. As is known, collapse does not take place in these models, which is why the solitons may be stable. The general solution is obtained in an approximate analytical form by means of a variational approach, which also allows the stability of the solutions to be predicted. Then, we directly simulate the two-dimensional case, taking the initial configuration as suggested by the variational approximation. We thus demonstrate that spatiotemporal solitons indeed exist and are stable. Furthermore, they are not, in the general case, equivalent to the previously known cylindrical spatial solitons. Direct simulations generate solitons with some internal oscillations. However, these oscillations neither grow nor do they exhibit any significant radiative damping. Numerical solutions of the stationary version of the equations produce the same solitons in their unperturbed form, i.e., without internal oscillations. Strictly stable solitons exist only if the system has anomalous dispersion at both the fundamental harmonic and second harmonic (SH), including the case of zero dispersion at SH. Quasistationary solitons, decaying extremely slowly into radiation, are found in the presence of weak normal dispersion at the second-harmonic frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the properties of light beams carrying phase singularities, or optical vortices. The transformations of topological charge during free-space propagation of a light wave, which is a combination of a Gaussian beam and a multiple charged optical vortex within a Gaussian envelope, are studied both in theory and experiment. We revise the existing knowledge about topological charge conservation, and demonstrate possible scenarios where additional vortices appear or annihilate during free propagation of such a combined beam. Coaxial interference of optical vortices is also analyzed, and the general rule for angular-momentum density distribution in a combined beam is established. We show that, in spite of any variation in the number of vortices in a combined beam, the total angular momentum is constant during the propagation. [S1050-2947(97)09910-1].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liver transplantation increased 1.84-fold from 1988 to 2004. However, the number of patients on the waiting list for a liver increased 2.71-fold, from 553 to 1500. We used a mathematical equation to analyze the potential effect of using ABO-compatible living-donor liver transplantation (LDLT) on both our liver transplantation program and the waiting list. We calculated the prevalence distribution of blood groups (O, A, B, and AB) in the population and the probability of having a compatible parent or sibling for LDLT. The incidence of ABO compatibility in the overall population was as follows: A, 0.31; B, 0.133; O, 0.512; and AB, 0.04. The ABO compatibility for parent donors was blood group A, 0.174; B, 0.06; O, 0.152; and AB, 0.03; and for sibling donors was A, 0.121; B, 0.05; O, 0.354; and AB, 0.03. Use of LDLT can reduce the pressure on our liver transplantation waiting list by decreasing its size by at least 16.5% at 20 years after its introduction. Such a program could save an estimated 3600 lives over the same period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liver transplantation was first performed at the University of Sao Paulo School of Medicine in 1968. Since then, the patient waiting list for liver transplantation has increased at a rate of 150 new cases per month. Liver transplantation itself rose 1.84-fold (from 160 to 295) from 1988 to 2004. However, the number of patients on the liver waiting list jumped 2.71-fold (from 553 to 1500). Consequently, the number of deaths on the liver waiting list moved to a higher level, from 321 to 671, increasing 2.09-fold. We have applied a mathematical model to analyze the potential impact of using a donation after cardiac death (DCD) policy on our liver transplantation program and on the waiting list. Five thousand one hundred people died because of accidents and other violent causes in our state in 2004; of these, only 295 were donors of liver grafts that were transplanted. The model assumed that 5% of these grafts would have been DCD. We found a relative reduction of 27% in the size of the liver transplantation waiting list if DCD had been used by assuming that 248 additional liver transplants would have been performed annually. In conclusion, the use of DCD in our transplantation program would reduce the pressure on our liver transplantation waiting list, reducing it by at least 27%. On the basis of this model, the projected number of averted deaths is about 41,487 in the next 20 years. Liver Transpl 14:1732-1736, 2008. (C) 2008 AASLD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three patients with progressive visual loss, chronic alcoholism and tabagism were submitted to a complete neuro-ophthalmic examination and to retinal nerve fiber layer (RNFL) measurements using optical coherence tomography (OCT) scanning. Two patients showed marked RNFL loss in the temporal sector of the optic disc. However, a third patient presented RNFL measurements within or above normal limits, based on the Stratus-OCT normative database. Such findings may be due to possible RNFL edema similar to the one that may occur in the acute phase of toxic optic neuropathies. Stratus-OCT was able to detect RNFL loss in the papillomacular bundle of patients with tobacco-alcohol-induced toxic optic neuropathy. However, interpretation must be careful when OCT does not show abnormality in order to prevent diagnostic confusion, since overestimation of RNFL thickness measurements is possible in such cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bipolar disorder (BD) is a chronic, severe, and highly disabling psychiatric disorder. Its underlying neurobiology remains largely unclear. A significant body of evidence indicates that inflammatory activation expressed by increased cytokines is relevant in its pathophysiology. IL-6 is one of the most important cytokines involved in the pathogenesis of immune and inflammatory disorders. Several studies recently showed increased levels of IL-6 in manic and depressive episodes and also during euthymia in subjects with BD. Tocilizumab is an IL-6 receptor antagonist being marketed for the treatment of rheumatoid arthritis and Castleman`s disease. In this article we discuss the possibility that tocilizumab may have a therapeutic role in treatment of BD through its anti-inflammatory action. (C) 2010 Elsevier Ltd. All rights reserved.