998 resultados para general device
Resumo:
PURPOSE: The longitudinal relaxation rate (R1 ) measured in vivo depends on the local microstructural properties of the tissue, such as macromolecular, iron, and water content. Here, we use whole brain multiparametric in vivo data and a general linear relaxometry model to describe the dependence of R1 on these components. We explore a) the validity of having a single fixed set of model coefficients for the whole brain and b) the stability of the model coefficients in a large cohort. METHODS: Maps of magnetization transfer (MT) and effective transverse relaxation rate (R2 *) were used as surrogates for macromolecular and iron content, respectively. Spatial variations in these parameters reflected variations in underlying tissue microstructure. A linear model was applied to the whole brain, including gray/white matter and deep brain structures, to determine the global model coefficients. Synthetic R1 values were then calculated using these coefficients and compared with the measured R1 maps. RESULTS: The model's validity was demonstrated by correspondence between the synthetic and measured R1 values and by high stability of the model coefficients across a large cohort. CONCLUSION: A single set of global coefficients can be used to relate R1 , MT, and R2 * across the whole brain. Our population study demonstrates the robustness and stability of the model. Magn Reson Med, 2014. © 2014 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. Magn Reson Med 73:1309-1314, 2015. © 2014 Wiley Periodicals, Inc.
Resumo:
En los últimos años, se ha llevado a cabo un considerable esfuerzo de análisis y catalogación de la ingente cantidad de mapas militares, planos, croquis y vistas panorámicas realizados durante la Guerra Civil española, pero aún quedan múltiples aspectos por investigar. En este artículo, analizamos la formación cartográfica del general Vicente Rojo -el jefe del Estado Mayor del Ejército de Tierra republicano-, las relaciones de Rojo con la cartografía durante la Guerra Civil y la cartografía militar contenida en su archivo personal, que se custodia en el Archivo Histórico Nacional de Madrid. Dicha cartografía posee un gran valor cartográfico y militar, porque fue utilizada por el Estado Mayor del Ejército de Tierra republicano durante el período en que Rojo estuvo al frente del mismo, y porque contiene una serie de documentos cartográficos manuscritos inéditos de gran importancia para comprender el desarrollo de algunas de las operaciones bélicas principales.
Resumo:
Objective: To determine the variation in prevalence of temporomandibular disorders (TMD), other side effects, and technical complications during 5 years of sleep apnea treatment with a mandibular advancement device. Materials and Methods: Forty patients diagnosed with obstructive sleep apnea received an adjustable appliance at 70% of the maximum protrusion. The protrusion was then progressively increased. TMD (diagnosed according to the Research Diagnostic Criteria for TMD), overjet, overbite, occlusal contacts, subjective side effects, and technical complications were recorded before and a mean of 14, 21, and 58 months after treatment and analyzed by the Wilcoxon test (P Less-than .05). Results: Fifteen patients still used the oral appliance at the 5-year follow-up, and no significant variation in TMD prevalence was observed. Subjective side effects were common, and a significant reduction was found in overjet, overbite, and in the number of occlusal contacts. Furthermore, the patients made a mean of 2.5 unscheduled dental visits per year and a mean of 0.8 appliance repairs/relines per year by a dental technician. The most frequent unscheduled visits were needed during the first year and were a result of acrylic breakage on the lateral telescopic attachment, poor retention, and other adjustments to improve comfort. Conclusions: Five-year oral appliance treatment does not affect TMD prevalence but is associated with permanent occlusal changes in most sleep apnea patients during the first 2 years. Patients seek several unscheduled visits, mainly because of technical complications.
Resumo:
The Iowa Department of Transportation research project HR-1013 is the evaluation of a prototype continuous monitoring nuclear density unit. The Unit, the Consolidation Monitoring Device (CMD), mounts on the rear of a slip-form paver and measures the density of the concrete while still in the plastic state. The evaluation performed determined the usefulness, accuracy, precision and reproducibility of the unit. The CMD was calibrated and tested in the laboratory for one week before field evaluation. The field evaluation consisted of monitoring at least 5 miles of paving and then correlating the CMD data with two conventional density methods. The two supplemental methods were density measurement with a Troxler nuclear gauge and densities obtained from core samples.
Resumo:
The Swiss postgraduate training program in general internal medicine is now designed as a competency-based curriculum. In other words, by the end of their training, the residents should demonstrate a set of predefined competences. Many of those competences have to be learnt in outpatient settings. Thus, the primary care physicians have more than ever an important role to play in educating tomorrows doctors. A competency-based model of training requires a regular assessment of the residents. The mini-CEX (mini-Clinical Evaluation eXercise) is the assessment tool proposed by the Swiss institute for postgraduate and continuing education. The mini-CEX is based on the direct observation of the trainees performing a specific task, as well as on the ensuing feedback. This article aims at introducing our colleagues in charge of residents to the mini-CEX, which is a useful tool promoting the culture of feedback in medical education.
Resumo:
INTRODUCTION: Delirium is a highly prevalent disorder, with serious consequences for the hospitalised patient. Nevertheless, it remains under-diagnosed and under-treated. We developed evidence-based clinical practice guidelines (CPGs) focusing on prevention, screening, diagnosis, and treatment of delirium in a general hospital. This article presents the implementation process of these CPGs and a before-after study assessing their impact on healthcare professionals' knowledge and on clinical practice. METHODS: CPGs on delirium were first implemented in two wards (Neurology and Neurosurgery) of the Lausanne university hospital. Interactive one-hour educational sessions for small groups of nurses and physicians were organised. Participants received a summary of the guidelines and completed a multiple choice questionnaire, assessing putative changes in knowledge, before and three months after the educational session. Other indicators such as "diagnosis of delirium" reported in the discharge letters, and mean duration of patients' hospital stay before and after implementation were compared. RESULTS: Eighty percent of the nurses and physicians from the Neurology and Neurosurgery wards attended the educational sessions. Both nurses and physicians significantly improved their knowledge after the implementation (+9 percentage-points). Other indicators were not modified by the intervention. CONCLUSION: A single interactive intervention improved both nurses' and physicians' knowledge on delirium. Sustained and repeated interventions are probably needed to demonstrate changes in clinical practice.
Resumo:
OBJECTIVE: The major source of hemolysis during cardiopulmonary bypass remains the cardiotomy suction and is primarily due to the interaction between air and blood. The Smart suction system involves an automatically controlled aspiration designed to avoid the mixture of blood with air. This study was set-up to compare this recently designed suction system to a Cell Saver system in order to investigate their effects on blood elements during prolonged intrathoracic aspiration. METHODS: In a calf model (n=10; mean weight, 69.3+/-4.5 kg), a standardized hole was created in the right atrium allowing a blood loss of 100 ml/min, with a suction cannula placed into the chest cavity into a fixed position during 6 h. The blood was continuously aspirated either with the Smart suction system (five animals) or the Cell Saver system (five animals). Blood samples were taken hourly for blood cell counts and biochemistry. RESULTS: In the Smart suction group, red cell count, plasma protein and free hemoglobin levels remained stable, while platelet count exhibited a significant drop from the fifth hour onwards (prebypass: 683+/-201*10(9)/l, 5 h: 280+/-142*10(9)/l, P=0.046). In the Cell Saver group, there was a significant drop of the red cell count from the third hour onwards (prebypass: 8.6+/-0.9*10(12)/l, 6 h: 6.3+/-0.4*10(12)/l, P=0.02), of the platelet count from the first hour onwards (prebypass: 630+/-97*10(9)/l, 1 h: 224+/-75*10(9)/l, P<0.01), and of the plasma protein level from the first hour onwards (prebypass: 61.7+/-0.6 g/l, 1 h: 29.3+/-9.1 g/l, P<0.01). CONCLUSIONS: In this experimental set-up, the Smart suction system avoids damage to red cells and affects platelet count less than the Cell Saver system which induces important blood cell destruction, as any suction device mixing air and blood, as well as severe hypoproteinemia with its metabolic, clotting and hemodynamic consequences.
Resumo:
A transcript of the Condition of the State of Iowa speech by Governor Larrabee delivered at the State Capitol.
Resumo:
A transcript of the Condition of the State of Iowa speech by Governor Shaw delivered at the State Capitol.
Resumo:
A transcript of the Condition of the State of Iowa speech by Governor Cummins delivered at the State Capitol.
Resumo:
A transcript of the Condition of the State of Iowa speech by Governor Cummins delivered at the State Capitol.
Resumo:
A transcript of the Condition of the State of Iowa speech by Governor Kendall delivered at the State Capitol.