952 resultados para arterial stiffness


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs. Design-Diagnostic test evaluation. ANIMALS: 29 client-owned dogs. PROCEDURES: 5 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detector, a standard oscillometric device (STO), and a high-definition oscillometric device (HDO). RESULTS: When the individual sets of 5 to 7 readings were evaluated, the coefficient of variation for systolic arterial blood pressure (SAP) exceeded 20% for 0% (Doppler), 11 % (STO), and 28% (HDO) of the sets of readings. After readings that exceeded a 20% coefficient of variation were discarded, repeatability was within 25 (Doppler), 37 (STO), and 39 (HDO) mm Hg for SAP. Correlation of mean values among the devices was between 0.47 and 0.63. Compared with Doppler readings, STO underestimated and HDO overestimated SAP. Limits of agreement between mean readings of any 2 devices were wide. With the hypertension scale used to score SAP, the intraclass correlation of scores was 0.48. Linear-weighted inter-rater reliability between scores was 0.40 (Doppler vs STO), 0.38 (Doppler vs HDO), and 0.29 (STO vs HDO). CONCLUSIONS AND CLINICAL RELEVANCE: Results of this study suggested that no meaningful clinical comparison can be made between blood pressure readings obtained from the same dog with different indirect blood pressure measurement devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endothelial dysfunction is recognized as the primum movens in the development of atherosclerosis. Its crucial role in both cardiovascular morbidity and mortality has been confirmed. In the past, research was hampered by the invasive character of endothelial function assessment. The development of non-invasive and feasible techniques to measure endothelial function has facilitated and promoted research in various adult and paediatric subpopulations. To avoid user dependence of flow-mediated dilation (FMD), which evaluates nitric oxide dependent vasodilation in large vessels, a semi-automated, method to assess peripheral microvascular function, called peripheral arterial tonometry (Endo-PAT®), was recently introduced. The number of studies using this technique in children and adolescents is rapidly increasing, yet there is no consensus with regard to either measuring protocol or data analysis of peripheral arterial tonometry in children and adolescents. Most paediatric studies simply applied measuring and analysing methodology established in adults, a simplification that may not be appropriate. This paper provides a detailed description of endothelial function assessment using the Endo-PAT for researchers and clinicians. We discuss clinical and methodological considerations and point out the differences between children, adolescents and adults. Finally, the main aim of this paper is to provide recommendations for a standardised application of Endo-PAT in children and adolescents, as well as for population-specific data analysis methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyse our results of using a double arterial perfusion strategy to avoid lower body hypothermic circulatory arrest after extensive thoracic aortic surgery. METHODS We analysed the intra- and perioperative courses of 10 patients (median age 58 years, median logistic EuroSCORE 14.6) who underwent extensive thoracic aortic surgery with a double arterial perfusion strategy. The main goal of double arterial perfusion is to separate myocardial and supra-aortic from systemic perfusion. Aortic repair starts at the most distal level of the descending aorta, followed by reinsertion of the supra-aortic vessels, and ends with completion of the proximal anastomosis or by any kind of root repair as needed. RESULTS Seven of 10 patients had prior surgery of the thoracic aorta. Indications for surgery were post-dissection aneurysm in 4 patients, true aneurysm in 3, anastomotic aneurysms in 2 and Type B aortic dissection with pseudo-coarctation in 1. Surgical access was performed through median sternotomy with left hemi-clamshell extension in all cases. There was no in-hospital mortality, but perioperative neurological symptoms occurred in 2 patients. These 2 patients developed delayed stroke (after awaking) after an initial uneventful clinical course, and in 1 of them, neurological symptoms resolved completely during follow-up. The median follow-up was 7 (±13) months. There was no death and no need for additional redo surgery during this observational period. CONCLUSIONS Extensive surgery of the thoracic aorta using a double arterial perfusion technique in order to avoid lower body hypothermic circulatory arrest is an attractive option. Further refinements of this technique may enable the safe and effective simultaneous multisegmental treatment of thoracic aortic pathology in patients who would otherwise have to undergo a two-step surgical approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Children conceived by assisted reproductive technologies (ART) display a level of vascular dysfunction similar to that seen in children of mothers with preeclamspia. The long-term consequences of ART-associated vascular disorders are unknown and difficult to investigate in healthy children. Here, we found that vasculature from mice generated by ART display endothelial dysfunction and increased stiffness, which translated into arterial hypertension in vivo. Progeny of male ART mice also exhibited vascular dysfunction, suggesting underlying epigenetic modifications. ART mice had altered methylation at the promoter of the gene encoding eNOS in the aorta, which correlated with decreased vascular eNOS expression and NO synthesis. Administration of a deacetylase inhibitor to ART mice normalized vascular gene methylation and function and resulted in progeny without vascular dysfunction. The induction of ART-associated vascular and epigenetic alterations appeared to be related to the embryo environment; these alterations were possibly facilitated by the hormonally stimulated ovulation accompanying ART. Finally, ART mice challenged with a high-fat diet had roughly a 25% shorter life span compared with control animals. This study highlights the potential of ART to induce vascular dysfunction and shorten life span and suggests that epigenetic alterations contribute to these problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Secondary hypertension refers to arterial hypertension due to an identifiable cause and affects ∼5-10% of the general hypertensive population. Because secondary forms are rare and work up is time-consuming and expensive, only patients with clinical suspicion should be screened. In recent years, some new aspects gained importance regarding this screening. In particular, increasing evidence suggests that 24 h ambulatory blood pressure (BP) monitoring plays a central role in the work up of patients with suspected secondary hypertension. Moreover, obstructive sleep apnoea has been identified as one of the most frequent causes. Finally, the introduction of catheter-based renal denervation for the treatment of patients with resistant hypertension has dramatically increased the interest and the number of patients evaluated for renal artery stenosis. We review the clinical clues of the most common causes of secondary hypertension. Specific recommendations are given as to evaluation and treatment of various forms of secondary hypertension. Despite appropriate therapy or even removal of the secondary cause, BP rarely ever returns to normal with long-term follow-up. Such residue hypertension indicates either that some patients with secondary hypertension also have concomitant essential hypertension or that irreversible vascular remodelling has taken place. Thus, in patients with potentially reversible causes of hypertension, early detection and treatment are important to minimize/prevent irreversible changes in the vasculature and target organs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Degeneration of the intervertebral disc, sometimes associated with low back pain and abnormal spinal motions, represents a major health issue with high costs. A non-invasive degeneration assessment via qualitative or quantitative MRI (magnetic resonance imaging) is possible, yet, no relation between mechanical properties and T2 maps of the intervertebral disc (IVD) has been considered, albeit T2 relaxation time values quantify the degree of degeneration. Therefore, MRI scans and mechanical tests were performed on 14 human lumbar intervertebral segments freed from posterior elements and all soft tissues excluding the IVD. Degeneration was evaluated in each specimen using morphological criteria, qualitative T2 weighted images and quantitative axial T2 map data and stiffness was calculated from the load-deflection curves of in vitro compression, torsion, lateral bending and flexion/extension tests. In addition to mean T2, the OTSU threshold of T2 (TOTSU), a robust and automatic histogram-based method that computes the optimal threshold maximizing the distinction of two classes of values, was calculated for anterior, posterior, left and right regions of each annulus fibrosus (AF). While mean T2 and degeneration schemes were not related to the IVDs' mechanical properties, TOTSU computed in the posterior AF correlated significantly with those classifications as well as with all stiffness values. TOTSU should therefore be included in future degeneration grading schemes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This prospective nonrandomized study compared the safety and efficacy of a novel arterial closure device (ACD) in common femoral artery procedures to that of the FDA submitted historical manual pressure control group, who underwent either a diagnostic angiogram (DA) or a percutaneous coronary intervention (PCI) procedure. Methods and Results A total of 55 patients were enrolled in this study of the novel ACD. Of the 55 patients, 39 were enrolled in the DA group and 16 were enrolled in the PCI group. Six patients were excluded. A device was deployed in 49 patients. Time to hemostasis (TTH), time to ambulation (TTA), device function, and device-related vascular complications were measured. In the device group, the TTH for the combined DA and PCI patients was 32 seconds (0.54 ± 0.93 minutes), significantly lower when compared with 16.0 ± 12.2 minutes (P < 0.0001) for the control group. Overall major vascular complication rate did not differ significantly, device group (1/49) and the historical control group (1/217). TTA in the combined PCI and DA device group was 226.4 ± 231.9 at the German site (site ambulation policy). In the Irish site, the average TTA in the PCI group was 187 minutes (n = 8) and 85 minutes (n = 14) in the DA group. Conclusion The Celt ACD® device is safe, effective, and significantly decreases the TTH compared to manual pressure and has a low vascular complications rate. The device may be effective in early ambulation and discharge of patients postcoronary intervention procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the complexity of active medical implants increases, the task of embedding a life-long power supply at the time of implantation becomes more challenging. A periodic renewal of the energy source is often required. Human energy harvesting is, therefore, seen as a possible remedy. In this paper, we present a novel idea to harvest energy from the pressure-driven deformation of an artery by the principle of magneto-hydrodynamics. The generator relies on a highly electrically conductive fluid accelerated perpendicularly to a magnetic field by means of an efficient lever arm mechanism. An artery with 10 mm inner diameter is chosen as a potential implantation site and its ability to drive the generator is established. Three analytical models are proposed to investigate the relevant design parameters and to determine the existence of an optimal configuration. The predicted output power reaches 65 μW according to the first two models and 135 μW according to the third model. It is found that the generator, designed as a circular structure encompassing the artery, should not exceed a total volume of 3 cm3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Engineers are confronted with the energy demand of active medical implants in patients with increasing life expectancy. Scavenging energy from the patient’s body is envisioned as an alternative to conventional power sources. Joining in this effort towards human-powered implants, we propose an innovative concept that combines the deformation of an artery resulting from the arterial pressure pulse with a transduction mechanism based on magneto-hydrodynamics. To overcome certain limitations of a preliminary analytical study on this topic, we demonstrate here a more accurate model of our generator by implementing a three-dimensional multiphysics finite element method (FEM) simulation combining solid mechanics, fluid mechanics, electric and magnetic fields as well as the corresponding couplings. This simulation is used to optimize the generator with respect to several design parameters. A first validation is obtained by comparing the results of the FEM simulation with those of the analytical approach adopted in our previous study. With an expected overall conversion efficiency of 20% and an average output power of 30 μW, our generator outperforms previous devices based on arterial wall deformation by more than two orders of magnitude. Most importantly, our generator provides sufficient power to supply a cardiac pacemaker.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of perfusion in longitudinal studies allows for the assessment of tissue integrity and the detection of subtle pathologies. In this work, the feasibility of measuring brain perfusion in rats with high spatial resolution using arterial spin labeling is reported. A flow-sensitive alternating recovery sequence, coupled with a balanced gradient fast imaging with steady-state precession readout section was used to minimize ghosting and geometric distortions, while achieving high signal-to-noise ratio. The quantitative imaging of perfusion using a single subtraction method was implemented to address the effects of variable transit delays between the labeling of spins and their arrival at the imaging slice. Studies in six rats at 7 T showed good perfusion contrast with minimal geometric distortion. The measured blood flow values of 152.5+/-6.3 ml/100 g per minute in gray matter and 72.3+/-14.0 ml/100 g per minute in white matter are in good agreement with previously reported values based on autoradiography, considered to be the gold standard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Renal failure after thoracoabdominal aortic repair is a significant clinical problem. Distal aortic perfusion for organ and spinal cord protection requires cannulation of the left femoral artery. In 2006, we reported the finding that direct cannulation led to leg ischemia in some patients and was associated with increased renal failure. After this finding, we modified our perfusion technique to eliminate leg ischemia from cannulation. In this article, we present the effects of this change on postoperative renal function. METHODS: Between February 1991 and July 2008, we repaired 1464 thoracoabdominal aortic aneurysms. Distal aortic perfusion was used in 1088, and these were studied. Median patient age was 68 years, and 378 (35%) were women. In September 2006, we began to adopt a sidearm femoral cannulation technique that provides distal aortic perfusion while maintaining downstream flow to the leg. This was used in 167 patients (15%). We measured the joint effects of preoperative glomerular filtration rate (GFR) and cannulation technique on the highest postoperative creatinine level, postoperative renal failure, and death. Analysis was by multiple linear or logistic regression with interaction. RESULTS: The preoperative GFR was the strongest predictor of postoperative renal dysfunction and death. No significant main effects of sidearm cannulation were noted. For peak creatinine level and postoperative renal failure, however, strong interactions between preoperative GFR and sidearm cannulation were present, resulting in reductions of postoperative renal complications of 15% to 20% when GFR was <60 mL>/min/1.73 m(2). For normal GFR, the effect was negated or even reversed at very high levels of GFR. Mortality, although not significantly affected by sidearm cannulation, showed a similar trend to the renal outcomes. CONCLUSION: Use of sidearm cannulation is associated with a clinically important and highly statistically significant reduction in postoperative renal complications in patients with a low GFR. Reduced renal effect of skeletal muscle ischemia is the proposed mechanism. Effects among patients with good preoperative renal function are less clear. A randomized trial is needed.