975 resultados para Vulcanization characteristics based on accelerator combinations
Resumo:
While cell sorting usually relies on cell-surface protein markers, molecular beacons (MBs) offer the potential to sort cells based on the presence of any expressed mRNA and in principle could be extremely useful to sort rare cell populations from primary isolates. We show here how stem cells can be purified from mixed cell populations by sorting based on MBs. Specifically, we designed molecular beacons targeting Sox2, a well-known stem cell marker for murine embryonic (mES) and neural stem cells (NSC). One of our designed molecular beacons displayed an increase in fluorescence compared to a nonspecific molecular beacon both in vitro and in vivo when tested in mES and NSCs. We sorted Sox2-MB(+)SSEA1(+) cells from a mixed population of 4-day retinoic acid-treated mES cells and effectively isolated live undifferentiated stem cells. Additionally, Sox2-MB(+) cells isolated from primary mouse brains were sorted and generated neurospheres with higher efficiency than Sox2-MB(-) cells. These results demonstrate the utility of MBs for stem cell sorting in an mRNA-specific manner.
Resumo:
The gated operation is proposed as an effective method to reduce the noise in pixel detectors based on Geiger mode avalanche photodiodes. A prototype with the sensor and the front-end electronics monolithically integrated has been fabricated with a conventional HV-CMOS process. Experimental results demonstrate the increase of the dynamic range of the sensor by applying this technique.
Resumo:
Gas sensing systems based on low-cost chemical sensor arrays are gaining interest for the analysis of multicomponent gas mixtures. These sensors show different problems, e.g., nonlinearities and slow time-response, which can be partially solved by digital signal processing. Our approach is based on building a nonlinear inverse dynamic system. Results for different identification techniques, including artificial neural networks and Wiener series, are compared in terms of measurement accuracy.
Resumo:
This paper presents a historical examination of employment in old age in Spain, in order to characterize this labour segment and identify and analyse its specific problems. One of these problems is the life-cycle deskilling process, already shown for certain national cases. This study explores whether this hypothesis also holds in Spain. The perspective used is essentially quantitative, as our analysis is based on the age-profession tables in Spanish population censuses from 1900 to 1970.
Resumo:
This contribution builds upon a former paper by the authors (Lipps and Betz 2004), in which a stochastic population projection for East- and West Germany is performed. Aim was to forecast relevant population parameters and their distribution in a consistent way. We now present some modifications, which have been modelled since. First, population parameters for the entire German population are modelled. In order to overcome the modelling problem of the structural break in the East during reunification, we show that the adaptation process of the relevant figures by the East can be considered to be completed by now. As a consequence, German parameters can be modelled just by using the West German historic patterns, with the start-off population of entire Germany. Second, a new model to simulate age specific fertility rates is presented, based on a quadratic spline approach. This offers a higher flexibility to model various age specific fertility curves. The simulation results are compared with the scenario based official forecasts for Germany in 2050. Exemplary for some population parameters (e.g. dependency ratio), it can be shown that the range spanned by the medium and extreme variants correspond to the s-intervals in the stochastic framework. It seems therefore more appropriate to treat this range as a s-interval covering about two thirds of the true distribution.
Resumo:
RÉSUMÉ EN FRANCAIS : Introduction: Le pseudoxanthome élastique (PXE) est une maladie génétique. Les mutations responsables ont été localisées au niveau du gène codant le transporteur transmembranaire ABC-C6. Des calcifications pathologiques des fibres élastiques de la peau, des yeux et du système cardiovasculaire en sont la conséquence. Buts: Evaluer les critères diagnostiques actuels du PXE en se basant sur les données moléculaires. Méthodes: 142 sujets provenant de 10 familles avec une anamnèse familiale positive pour le PXE ont été investiguées sur le plan clinique, histopathologique et génétique. Résultats: 25 sujets se sont avérés être homozygotes pour le gène PXE muté. 23 d'entre eux ont présenté les manifestations cliniques et histopathologique typiques. Les deux autres souffraient d'une élastose et d'une dégénérescence maculaire si importante qu'un diagnostic de PXE ne pouvait pas être confirmé cliniquement. 67 sujets se sont révélés être des porteurs hétérozygotes et 50 ne présentaient pas de mutation. De ces 117 sujets, 116 n'ont montré aucune lésion cutanée ou ophtalmique pouvant correspondre au PXE. Un seul des sujets sans mutation a présenté une importante élastose solaire ainsi qu'une cicatrisation de la rétine, imitant les lésions typiques du PXE. Quatre des 67 sujets hétérozygotes ont eu une biopsie de peau, dont les analyses histopathologique se sont avérées normales. Conclusion: Dans notre cohorte de patients, le PXE était transmis exclusivement de façoh autosomique récessive. La corrélation retrouvée entre le génotype et le phénotype a permis de confirmer les critères diagnostiques majeurs actuels. Le diagnostic clinique peut être difficile, voir impossible, chez des patients atteints d'une élastose solaire importante et/ou d'une dégénérescence maculaire étendue. Dans ces cas, un test moléculaire est nécessaire afin de confirmer le diagnostic de PXE. A notre connaissance, notre étude présentée ici est le premier travail comparant des données cliniques à des données moléculaires dans le domaine du PXE. ABSTRACT : Background: Pseudoxanthoma elasticum (PXE) is a genetic disorder due to mutations in the gene encoding the transmembrane transporter protein adenosine triphosphate binding cassette (ABC)-C6, resulting in calcifications of elastic fibers in the skin, eyes and cardiovascular system. Objectives: To evaluate the diagnostic criteria for PXE based on molecular data. Methods: Of 10 families with a positive history of PXE 142 subjects were investigated for clinical symptoms, histological findings and genetic haplotype analysis. Results: Of these, 25 subjects were haplotypic homozygous for PXE and 23 had typical clinical and histopathological manifestations. Two of the 25 patients showed such marked solar elastosis and macular degeneration that PXE could not be confirmed clinically. Sixty-seven subject were haplotypic heterozygous carriers and 50 haplotypic homozygous unaffected. Of these 117 subjects, 116 showed no cutaneous or ophthalmologic signs of PXE. In one of the 50 haplotypic homozygous unaffected patients important solar elastosis and scaring of the retina mimicked PXE lesions. Only four of the 67 haplotypic heterozygous carriers had biopsies of nonlesional skin; all were histopathologically normal. Conclusions: In our patients, PXE presents as an autosomal recessive genodermatosis. Correlation of haplotype and phenotype confirmed actual major diagnostic criteria. In patients with marked solar elastosis and/ or severe macular degeneration clinical diagnosis can be impossible and molecular testing is needed to confirm the presence of PXE. To the best of our knowledge our large study compares for the first time clinical findings with molecular data.
Resumo:
Macroporosity is often used in the determination of soil compaction. Reduced macroporosity can lead to poor drainage, low root aeration and soil degradation. The aim of this study was to develop and test different models to estimate macro and microporosity efficiently, using multiple regression. Ten soils were selected within a large range of textures: sand (Sa) 0.07-0.84; silt 0.03-0.24; clay 0.13-0.78 kg kg-1 and subjected to three compaction levels (three bulk densities, BD). Two models with similar accuracy were selected, with a mean error of about 0.02 m³ m-3 (2 %). The model y = a + b.BD + c.Sa, named model 2, was selected for its simplicity to estimate Macro (Ma), Micro (Mi) or total porosity (TP): Ma = 0.693 - 0.465 BD + 0.212 Sa; Mi = 0.337 + 0.120 BD - 0.294 Sa; TP = 1.030 - 0.345 BD 0.082 Sa; porosity values were expressed in m³ m-3; BD in kg dm-3; and Sa in kg kg-1. The model was tested with 76 datum set of several other authors. An error of about 0.04 m³ m-3 (4 %) was observed. Simulations of variations in BD as a function of Sa are presented for Ma = 0 and Ma = 0.10 (10 %). The macroporosity equation was remodeled to obtain other compaction indexes: a) to simulate maximum bulk density (MBD) as a function of Sa (Equation 11), in agreement with literature data; b) to simulate relative bulk density (RBD) as a function of BD and Sa (Equation 13); c) another model to simulate RBD as a function of Ma and Sa (Equation 16), confirming the independence of this variable in relation to Sa for a fixed value of macroporosity and, also, proving the hypothesis of Hakansson & Lipiec that RBD = 0.87 corresponds approximately to 10 % macroporosity (Ma = 0.10 m³ m-3).
Resumo:
INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.
Resumo:
Selostus: Ravintoaineiden saantiin ja maidontuotantoon vaikuttavat tekijät runsaalla säilörehuruokinnalla
Resumo:
Topical ocular drug delivery has always been a challenge for pharmaceutical technology scientists. In the last two decades, many nano-systems have been studied to find ways to overcome the typical problems of topical ocular therapy, such as difficult corneal penetration and poor drug availability. In this study, methoxy poly(ethylene glycol)-hexylsubstituted poly(lactides) (MPEG-hexPLA) micelle formulations, which are promising nanocarriers for poorly water soluble drugs, were investigated for the delivery of Cyclosporin A (CsA) to the eye. As a new possible pharmaceutical excipient, the ocular compatibility of MPEG-hexPLA micelle formulations was evaluated. An in vitro biocompatibility assessment on human corneal epithelial cells was carried out using different tests. Cytotoxicity was studied by using the [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide] (MTT), and clonogenic tests and revealed that the CsA formulations and copolymer solutions were not toxic. After incubation with MPEG-hexPLA micelle formulations, the activation of caspase-dependent and -independent apoptosis as well as autophagy was evaluated using immunohistochemistry by analyzing the localization of four antibodies: (1) anti-caspase 3; (2) anti-apoptotic inducing factor (AIF); (3) anti-IL-Dnase II and (4) anti-microtubule-associated protein 1 light chain 3 (LC3). No apoptosis was induced when the cells were treated with the micelle solutions that were either unloaded or loaded with CsA. The ocular tolerance was assessed in vivo on rabbit eyes by Confocal Laser Scanning Ophthalmoscopy (CLSO), and very good tolerability was seen. The observed corneal surface was comparable to a control surface that was treated with a 0.9% NaCl solution. In conclusion, these results demonstrate that MPEG-hexPLA micelles are promising drug carriers for ocular diseases involving the activation of cytokines, such as dry eye syndrome and autoimmune uveitis, or for the prevention of corneal graft rejection.
Resumo:
Selostus: Väkirehuruokinnan vaikutus maidontuotantoon karjantarkkailutiloilta kerätyssä kenttäaineistossa
Resumo:
Mechanical force modulates myriad cellular functions including migration, alignment, proliferation, and gene transcription. Mechanotransduction, the transmission of mechanical forces and its translation into biochemical signals, may be mediated by force induced protein conformation changes, subsequently modulating protein signaling. For the paxillin and focal adhesion kinase interaction, we demonstrate that force-induced changes in protein complex conformation, dissociation constant, and binding Gibbs free energy can be quantified by lifetime-resolved fluorescence energy transfer microscopy combined with intensity imaging calibrated by fluorescence correlation spectroscopy. Comparison with in vitro data shows that this interaction is allosteric in vivo. Further, spatially resolved imaging and inhibitor assays show that this protein interaction and its mechano-sensitivity are equal in the cytosol and in the focal adhesions complexes indicating that the mechano-sensitivity of this interaction must be mediated by soluble factors but not based on protein tyrosine phosphorylation.
Resumo:
Independent auditor’s report of the State of Iowa on internal control over financial reporting and on compliance and other matters based on an audit of financial statements performed in accordance with government auditing standards for the year ended June 30, 2011