999 resultados para Secondary calibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study we make a general research question [1] and two specific ones [2] i [3]: [1] How can we establish a new model for teaching and learning grammar? [2] How metalinguistic knowledge is built within this model? [3] How can we elaborate an analysis model for exploring grammar knowledge?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En aquesta tesis s'ha desenvolupat un sistema de control capaç d'optimitzar el funcionament dels Reactors Discontinus Seqüencials dins el camp de l'eliminació de matèria orgànica i nitrogen de les aigües residuals. El sistema de control permet ajustar en línia la durada de les etapes de reacció a partir de mesures directes o indirectes de sondes. En una primera etapa de la tesis s'ha estudiat la calibració de models matemàtics que permeten realitzar fàcilment provatures de diferents estratègies de control. A partir de l'anàlisis de dades històriques s'han plantejat diferents opcions per controlar l'SBR i les més convenients s'han provat mitjançant simulació. Després d'assegurar l'èxit de l'estratègia de control mitjançant simulacions s'ha implementat en una planta semi-industrial. Finalment es planteja l'estructura d'uns sistema supervisor encarregat de controlar el funcionament de l'SBR no només a nivell de fases sinó també a nivell cicle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper was written within the context of the research project “The development of teacher’ associative organizations and unionism (1889-1990)” funded by the Fundação para a Ciência e Tecnologia (Foundation for Science and Technology). Five important congresses about secondary education were organized in Portugal between 1927 and 1931. These congresses served to claim the rights of teachers and the consolidation of the class, as well as to promote the discussion of scientific and pedagogical problems. In these congresses, the presence of female teachers was residual. However, the few teachers who participated had a significant contribution to the definition of secondary education during the following decades. Among other issues, it contributed to the discussion of female education and to analyze the importance of Biology and Physical Education in high schools. This paper presents the analysis of the minutes of the 1927s and 1928s Congresses. This analysis allowed the assessment of the important role played by a group of teachers to define, at the end of the first third of the 20th century, the future guidelines of Portuguese secondary education. It also reported that these teachers were pioneers who opened the way for the increasing number of teachers in secondary education during the 20th century.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper examines the characteristics of the probe-tube microphone and its use in measuring sound pressure in the ear canal. Specifically the paper studies the free field and the coupler calibrations of several probe-tube microphones with tubes of different sizes and determines which characteristics of a probe tube are necessary for accurate measurements in both a free field and in a closed coupler.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper reports an interactive tool for calibrating a camera, suitable for use in outdoor scenes. The motivation for the tool was the need to obtain an approximate calibration for images taken with no explicit calibration data. Such images are frequently presented to research laboratories, especially in surveillance applications, with a request to demonstrate algorithms. The method decomposes the calibration parameters into intuitively simple components, and relies on the operator interactively adjusting the parameter settings to achieve a visually acceptable agreement between a rectilinear calibration model and his own perception of the scene. Using the tool, we have been able to calibrate images of unknown scenes, taken with unknown cameras, in a matter of minutes. The standard of calibration has proved to be sufficient for model-based pose recovery and tracking of vehicles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A traditional method of validating the performance of a flood model when remotely sensed data of the flood extent are available is to compare the predicted flood extent to that observed. The performance measure employed often uses areal pattern-matching to assess the degree to which the two extents overlap. Recently, remote sensing of flood extents using synthetic aperture radar (SAR) and airborne scanning laser altimetry (LIDAR) has made more straightforward the synoptic measurement of water surface elevations along flood waterlines, and this has emphasised the possibility of using alternative performance measures based on height. This paper considers the advantages that can accrue from using a performance measure based on waterline elevations rather than one based on areal patterns of wet and dry pixels. The two measures were compared for their ability to estimate flood inundation uncertainty maps from a set of model runs carried out to span the acceptable model parameter range in a GLUE-based analysis. A 1 in 5-year flood on the Thames in 1992 was used as a test event. As is typical for UK floods, only a single SAR image of observed flood extent was available for model calibration and validation. A simple implementation of a two-dimensional flood model (LISFLOOD-FP) was used to generate model flood extents for comparison with that observed. The performance measure based on height differences of corresponding points along the observed and modelled waterlines was found to be significantly more sensitive to the channel friction parameter than the measure based on areal patterns of flood extent. The former was able to restrict the parameter range of acceptable model runs and hence reduce the number of runs necessary to generate an inundation uncertainty map. A result of this was that there was less uncertainty in the final flood risk map. The uncertainty analysis included the effects of uncertainties in the observed flood extent as well as in model parameters. The height-based measure was found to be more sensitive when increased heighting accuracy was achieved by requiring that observed waterline heights varied slowly along the reach. The technique allows for the decomposition of the reach into sections, with different effective channel friction parameters used in different sections, which in this case resulted in lower r.m.s. height differences between observed and modelled waterlines than those achieved by runs using a single friction parameter for the whole reach. However, a validation of the modelled inundation uncertainty using the calibration event showed a significant difference between the uncertainty map and the observed flood extent. While this was true for both measures, the difference was especially significant for the height-based one. This is likely to be due to the conceptually simple flood inundation model and the coarse application resolution employed in this case. The increased sensitivity of the height-based measure may lead to an increased onus being placed on the model developer in the production of a valid model

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present here a method for calibrating an optical see-through Head Mounted Display (HMD) using techniques usually applied to camera calibration (photogrammetry). Using a camera placed inside the HMD to take pictures simultaneously of a tracked object and features in the HMD display, we could exploit established camera calibration techniques to recover both the intrinsic and extrinsic properties of the~HMD (width, height, focal length, optic centre and principal ray of the display). Our method gives low re-projection errors and, unlike existing methods, involves no time-consuming and error-prone human measurements, nor any prior estimates about the HMD geometry.