1000 resultados para SUBWAVELENGTH HOLE ARRAYS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To assess macular hole surgery in patients with end-stage choroideremia with regard to anatomic closure and visual outcome. DESIGN Retrospective, interventional case series. PARTICIPANTS Thirty adult male patients with a diagnosis of advanced choroideremia were reviewed and underwent spectral domain optical coherence tomography (OCT) as part of the screening process for a gene therapy clinical trial. From within that cohort, 3 were identified as having a full-thickness macular hole (FTMH). METHODS A 23-gauge pars plana vitrectomy was performed with peeling of the inner limiting membrane and gas tamponade. Preoperative best-corrected visual acuity ranged from perception of light to 6/24. MAIN OUTCOME MEASURES Prevalence of FTMH in advanced choroideremia, morphologic phenotype characteristics of FTMH in OCT, pre- and postoperative best-corrected visual acuity, and closure rate after surgery. RESULTS The prevalence of FTMH in advanced choroideremia in our cohort was 10%. One hole was associated with significant macular schisis, presumed to be attributable to degeneration of outer retinal layers. Anatomic closure was achieved in all 3 patients and confirmed with spectral domain OCT. Gas tamponade lasted approximately twice as long as might be expected compared with standard FTMH surgery. Objective visual acuity did not improve; however, perceived vision improved in all patients. CONCLUSIONS Although FTMH in choroideremia is a rare finding, it could potentially mask central progression of the disease. Regular screening may help to diagnose holes at an earlier stage when the visual prognosis after surgery may be better. Standard macular hole surgery seems to be effective in gaining anatomic closure, which would be significant for patients who subsequently require macula detachment for subretinal gene therapy. FINANCIAL DISCLOSURE(S) The authors have no proprietary or commercial interest in any of the materials discussed in this article.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Five seismic units may be identified in the similar to 8 m thick Holocene sediment package at the bottom of the Blue Hole, a 120 m deep sinkhole located in the atoll lagoon of Lighthouse Reef, Belize. These units may be correlated with the succession of an existing 5.85-m-long sediment core that reaches back to 1385 kyrs BP. The identification of seismic units is based on the fact that uniform, fine-grained background sediments show weak reflections while alternating background and coarser-grained event (storm) beds exhibit strong reflections in the seismic profiles. The main source of sediments is the marginal atoll reef and adjacent lagoon area to the east and north. Northeasterly winds and storms transport sediment into the Blue Hole, as seen in the eastward increase in sediment thickness, i.e., the eastward shallowing of the Blue Hole. Previous assumptions of much thicker Holocene sediment packages in the Blue Hole could not be confirmed. So far, close to 6-m-long cores were retrieved from the Blue Hole but the base of the sedimentary succession remains to be recovered. The nature of the basal sediments is unknown but mid-Holocene and possibly older, Pleistocene sinkhole deposits can be expected. The number of event beds identified in the Blue Hole (n = 37) during a 1.385 kyr-long period and the number of cyclones listed in historical databases suggest that only strong hurricanes (categories 4 and 5) left event beds in the Blue Hole sedimentary succession. Storm beds are numerous during 13-0.9 kyrs BP and 0.8-0.5 kyrs BP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bottom-up approach is introduced to fabricate two-dimensional self-assembled layers of molecular spin-systems containing Mn and Fe ions arranged in a chessboard lattice. We demonstrate that the Mn and Fe spin states can be reversibly operated by their selective response to coordination/decoordination of volatile ligands like ammonia (NH3).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding and controlling the structural anisotropies of injection-molded polymers is vital for designing products such as cantilever-based sensors. Such micro-cantilevers are considered as cost-effective alternatives to single-crystalline silicon-based sensors. In order to achieve similar sensing characteristics,structure and morphology have to be controlled by means of processing parameters including mold temperature and injection speed. Synchrotron radiation-based scanning small- (SAXS) and wide-angle x-ray scattering techniques were used to quantify crystallinity and anisotropy in polymer micro-cantilevers with micrometer resolution in real space. SAXS measurements confirmed the lamellar nature of the injection-molded semi-crystalline micro-cantilevers. The homogenous cantilever material exhibits a lamellar periodicity increasing with mold temperature but not with injection speed. We demonstrate that micro-cantilevers made of semi-crystalline polymers such as polyvinylidenefluoride, polyoxymethylene, and polypropylene show the expected strong degree of anisotropy along the injection direction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microinjection molding was employed to fabricate low-cost polymer cantilever arrays for sensor applications. Cantilevers with micrometer dimensions and aspect ratios as large as 10 were successfully manufactured from polymers, including polypropylene and polyvinylidenfluoride. The cantilevers perform similar to the established silicon cantilevers, with Q-factors in the range of 10–20. Static deflection of gold coated polymer cantilevers was characterized with heat cycling and self-assembled monolayer formation of mercaptohexanols. A hybrid mold concept allows easy modification of the surface topography, enabling customized mechanical properties of individual cantilevers. Combined with functionalization and surface patterning, the cantilever arrays are qualified for biomedical applications

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High brightness electron sources are of great importance for the operation of the hard X-ray free electron lasers. Field emission cathodes based on the double-gate metallic field emitter arrays (FEAs) can potentially offer higher brightness than the currently used ones. We report on the successful application of electron beam lithography for fabrication of the large-scale single-gate as well as double-gate FEAs. We demonstrate operational high-density single-gate FEAs with sub-micron pitch and total number of tips up to 106 as well as large-scale double-gate FEAs with large collimation gate apertures. The details of design, fabrication procedure and successful measurements of the emission current from the single- and double-gate cathodes are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The generation of collimated electron beams from metal double-gate nanotip arrays excited by near infrared laser pulses is studied. Using electromagnetic and particle tracking simulations, we showed that electron pulses with small rms transverse velocities are efficiently produced from nanotip arrays by laser-induced field emission with the laser wavelength tuned to surface plasmon polariton resonance of the stacked double-gate structure. The result indicates the possibility of realizing a metal nanotip array cathode that outperforms state-of-the-art photocathodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the course of this study, stiffness of a fibril array of mineralized collagen fibrils modeled with a mean field method was validated experimentally at site-matched two levels of tissue hierarchy using mineralized turkey leg tendons (MTLT). The applied modeling approaches allowed to model the properties of this unidirectional tissue from nanoscale (mineralized collagen fibrils) to macroscale (mineralized tendon). At the microlevel, the indentation moduli obtained with a mean field homogenization scheme were compared to the experimental ones obtained with microindentation. At the macrolevel, the macroscopic stiffness predicted with micro finite element (μFE) models was compared to the experimental stiffness measured with uniaxial tensile tests. Elastic properties of the elements in μFE models were injected from the mean field model or two-directional microindentations. Quantitatively, the indentation moduli can be properly predicted with the mean-field models. Local stiffness trends within specific tissue morphologies are very weak, suggesting additional factors responsible for the stiffness variations. At macrolevel, the μFE models underestimate the macroscopic stiffness, as compared to tensile tests, but the correlations are strong.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This Letter presents a search for quantum black-hole production using 20.3 fb(-1) of data collected with the ATLAS detector in pp collisions at the LHC at root s = 8 TeV. The quantum black holes are assumed to decay into a final state characterized by a lepton (electron or muon) and a jet. In either channel, no event with a lepton-jet invariant mass of 3.5 TeV or more is observed, consistent with the expected background. Limits are set on the product of cross sections and branching fractions for the lepton + jet final states of quantum black holes produced in a search region for invariant masses above 1 TeV. The combined 95% confidence level upper limit on this product for quantum black holes with threshold mass above 3.5 TeV is 0.18 fb. This limit constrains the threshold quantum black-hole mass to be above 5.3 TeV in the model considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the fabrication and field emission properties of high-density nano-emitter arrays with on-chip electron extraction gate electrodes and up to 106 metallic nanotips that have an apex curvature radius of a few nanometers and a the tip density exceeding 108 cm−2. The gate electrode was fabricated on top of the nano-emitter arrays using a self-aligned polymer mask method. By applying a hot-press step for the polymer planarization, gate–nanotip alignment precision below 10 nm was achieved. Fabricated devices exhibited stable field electron emission with a current density of 0.1 A cm−2, indicating that these are promising for applications that require a miniature high-brightness electron source.