931 resultados para Reliability assessment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the report for “Project IV” unit of the PhD programme on Technology Assessment. This thesis research has the supervision of António Moniz (FCT-UNL and ITAS-KIT) and Manuel Laranja (ISEG-UTL). Other members of the thesis committee are Stefan Kuhlmann (Twente University), Leonhard Hennen (Karlsruhe Institute of Technology-ITAS), Tiago Santos Pereira (Universidade de Coimbra/CES) and Cristina Sousa (FCT-UNL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paper presented as "key note" at the Doctorate Conference on Technology Assessment in June 2011, at FCT-UNL, Monte de Caparica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessing the safety of existing timber structures is of paramount importance for taking reliable decisions on repair actions and their extent. The results obtained through semi-probabilistic methods are unrealistic, as the partial safety factors present in codes are calibrated considering the uncertainty present in new structures. In order to overcome these limitations, and also to include the effects of decay in the safety analysis, probabilistic methods, based on Monte-Carlo simulation are applied here to assess the safety of existing timber structures. In particular, the impact of decay on structural safety is analyzed and discussed, using a simple structural model, similar to that used for current semi-probabilistic analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the report for the “Project III” unit of the PhD programme on Technology Assessment under the supervision of Prof. António B. Moniz. This report was discussed also at the 2nd Winter School on Technology Assessment held at Universidade Nova de Lisboa, Caparica Campus, Portugal on December 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the aim of studying the contamination of soils with eggs of Toxocara spp. in an arid area in the central-western region of Argentina, 76 soil samples were collected from 18 towns belonging to six provinces of central-western Argentina. They were processed by the centrifugal flotation method. No eggs of Toxocara spp. were found. It can be concluded that the negative results are directly related to the characteristics of the environment and climate present in the studied area. The finding of eggs in soils depends on several factors: the presence of canine or feline feces, the hygienic behavior of pet owners, the presence of stray animals without veterinary supervision, the weather and environmental conditions, and laboratory techniques used; and all these circumstances must be considered when comparing the results found in different geographical regions. In order to accurately define the importance of public spaces in the transmission of infection to humans, it is important to consider the role of backyards or green spaces around housing in small towns, where the population is not used to walking pets in public spaces, and in such cases a significant fraction of the population may acquire the infection within households.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Insulin resistance is the pathophysiological key to explain metabolic syndrome. Although clearly useful, the Homeostasis Model Assessment index (an insulin resistance measurement) hasn't been systematically applied in clinical practice. One of the main reasons is the discrepancy in cut-off values reported in different populations. We sought to evaluate in a Portuguese population the ideal cut-off for Homeostasis Model Assessment index and assess its relationship with metabolic syndrome. MATERIAL AND METHODS: We selected a cohort of individuals admitted electively in a Cardiology ward with a BMI < 25 Kg/m2 and no abnormalities in glucose metabolism (fasting plasma glucose < 100 mg/dL and no diabetes). The 90th percentile of the Homeostasis Model Assessment index distribution was used to obtain the ideal cut-off for insulin resistance. We also selected a validation cohort of 300 individuals (no exclusion criteria applied). RESULTS: From 7 000 individuals, and after the exclusion criteria, there were left 1 784 individuals. The 90th percentile for Homeostasis Model Assessment index was 2.33. In the validation cohort, applying that cut-off, we have 49.3% of individuals with insulin resistance. However, only 69.9% of the metabolic syndrome patients had insulin resistance according to that cut-off. By ROC curve analysis, the ideal cut-off for metabolic syndrome is 2.41. Homeostasis Model Assessment index correlated with BMI (r = 0.371, p < 0.001) and is an independent predictor of the presence of metabolic syndrome (OR 19.4, 95% CI 6.6 - 57.2, p < 0.001). DISCUSSION: Our study showed that in a Portuguese population of patients admitted electively in a Cardiology ward, 2.33 is the Homeostasis Model Assessment index cut-off for insulin resistance and 2.41 for metabolic syndrome. CONCLUSION: Homeostasis Model Assessment index is directly correlated with BMI and is an independent predictor of metabolic syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The index of microcirculatory resistance (IMR) enables/provides quantitative, invasive, and real-time assessment of coronary microcirculation status. AIMS: The primary aim of this study was to validate the assessment of IMR in a large animal model, and the secondary aim was to compare two doses of intracoronary papaverine, 5 and 10 mg, for induction of maximal hyperemia and its evolution over time. METHODS: Measurements of IMR were performed in eight pigs. Mean distal pressure (Pd) and mean transit time (Tmn) were measured at rest and at maximal hyperemia induced with intracoronary papaverine, 5 and 10 mg, and after 2, 5, 8 and 10 minutes. Disruption of the microcirculation was achieved by selective injection of 40-μm microspheres via a microcatheter in the left anterior descending artery. RESULTS: In each animal 14 IMR measurements were made. There were no differences between the two doses of papaverine regarding Pd response and IMR values - 11 ± 4.5 U with 5 mg and 10.6 ± 3 U with 10 mg (p=0.612). The evolution of IMR over time was also similar with the two doses, with significant differences from resting values disappearing after five minutes of intracoronary papaverine administration. IMR increased with disrupted microcirculation in all animals (41 ± 16 U, p=0.001). CONCLUSIONS: IMR provides invasive and real-time assessment of coronary microcirculation. Disruption of the microvascular bed is associated with a significant increase in IMR. A 5-mg dose of intracoronary papaverine is as effective as a 10-mg dose in inducing maximal hyperemia. After five minutes of papaverine administration there is no significant difference from resting hemodynamic status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Economic evaluations help health authorities facing budget constraints. This study compares the health-related quality of life (HRQOL) and costs in patient subgroups on haemodialysis (HD) and renal transplantation (KT). Methods: In a prospective study with follow-up of 1-3 years, we performed a costutility analysis of KT vs. HD, adopting a lifetime horizon. A societal perspective was taken. Costs for organ procurement, KT eligibility, transplant surgery and follow-up of living donors were included. Key clinical events were recorded. HRQOL was assessed using the EuroQol instrument. Results: The HRQOL remained stable on HD patients. After KT, mean utility score improved at 3 months while mean EQ-VAS scores showed a sustained improvement. Mean annual cost for HD was 32,567.57€. Mean annual costs for KT in the year-1 and in subsequent years were, 60,210.09€ and 12,956.77€ respectively. Cost for initial hospitalization averaged 18,740.74€. HLA-mismatches increased costs by 75% for initial hospitalization (p < 0.001) and 41% in the year-1 (p < 0.05), and duplicate the risk of readmission in the year-1 (p < 0.05). The incremental costutility ratio was 5,534.46€/QALY, increasing 35% when costs for organ procurement were added. KT costs were 41,541.63€ more but provided additional 7.51 QALY. Conclusions: The KT is cost-effective compared with HD. Public funding should reflect the value created by the intervention and adapt to the organ demand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Estatística e Gestão de Informação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION AND OBJECTIVES: Recurrent syncope has a significant impact on quality of life. The development of measurement scales to assess this impact that are easy to use in clinical settings is crucial. The objective of the present study is a preliminary validation of the Impact of Syncope on Quality of Life questionnaire for the Portuguese population. METHODS: The instrument underwent a process of translation, validation, analysis of cultural appropriateness and cognitive debriefing. A population of 39 patients with a history of recurrent syncope (>1 year) who underwent tilt testing, aged 52.1 ± 16.4 years (21-83), 43.5% male, most in active employment (n=18) or retired (n=13), constituted a convenience sample. The resulting Portuguese version is similar to the original, with 12 items in a single aggregate score, and underwent statistical validation, with assessment of reliability, validity and stability over time. RESULTS: With regard to reliability, the internal consistency of the scale is 0.9. Assessment of convergent and discriminant validity showed statistically significant results (p<0.01). Regarding stability over time, a test-retest of this instrument at six months after tilt testing with 22 patients of the sample who had not undergone any clinical intervention found no statistically significant changes in quality of life. CONCLUSIONS: The results indicate that this instrument is of value for assessing quality of life in patients with recurrent syncope in Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Introdução: A relação cinemática entre as articulações do CAO apresenta grande importância na função do MS, e é por isso cada vez mais investigada e descrita. O posicionamento da omoplata ganha um importante papel para compreender as DCAO. É indiscutível o importante papel da omoplata na dinâmica do MS, bem como o posicionamento escapular como parâmetro clínico de disfunção do CAO. Todos estes factores criam a necessidade de desenvolver instrumentos de avaliação da posição da articulação ET. A grande maioria dos testes de avaliação, restringem a sua avaliação às disfunções da articulação GU, não integrando uma avaliação mais dinâmica e interactiva que respeite os pressupostos teóricos inerentes ao REU. È importante também que os métodos de avaliação sejam de fácil aplicabilidade clínica e que avaliem fidedignamente e com validade os outcomes. Objectivos: Contribuir para o desenvolvimento de uma metodologia de avaliação da omoplata em diferentes amplitudes do MS, através do estudo da validade concorrente, da fidedignidade intra e inter-observador. Metodologia: A amostra foi constituída por 20 elementos seleccionados por conveniência, entre o corpo de discentes da ESS-IPS, sem história de disfunção do CAO. Foi realizada uma análise cinemática ao MS de cada sujeito, usando um aparelho de análise por varrimento electromagnético, o FOB. Em cada sujeito foram ainda medidas, as distâncias escapulares em estudo, usando a fita métrica. Cada método de medição foi constituído por dois momento (teste e reteste), em cada momento, as medidas eram recolhidas por dois investigadores distintos. Resultados e Discussão: Foram considerados como positivos os resultados que se apresentassem acima do limiar de 0,5, que classifica uma correlação como moderada a excelente. Os resultados da validade mostram que para o investigador 1 nas medidas M1e M2 apenas houve correlação com valores excelentes a moderados até aos 30º de elevação do MS. Já para M3 apenas aos 30º no plano da omoplata essa mesma correlação não tem valores próximos do cutpoint. Em M4 nenhum valor tem correlação significativa com os valores do FOB, chegando mesmo a haver correlação negativa para os 120º no plano da omoplata. Em M5 apenas os 0º mostram valores correlacionais excelentes a moderados. Para o investigador 2, em M1 e M2 á semelhança do investigador 1, só existem valores de correlação significativos até aos 30º de elevação do MS. Já para M3 todos os valores mostram excelente a moderada correlação á excepção dos 120º no plano frontal. Em M4 este investigador apresenta maus resultados. Já em M5 os valores de correlação são moderados aos 0º e aos 90º. No que diz respeitos aos resultados dos CCI intra-observador,podemos afirmar que foi em M5 que estes valores mais se aproximaram do cut point. M1 e M2 são as medidas onde se encontram resultados menos satisfatórios. É aos 60º que existem valores mais satisfatórios, seguidos pelos 0º e 30º, quando nos aproximamos de graus mais elevados, como 90º e 120º, estes valores tendem a baixar. Quanto á fidedignidade inter-observador para M1 apenas aos 90º e aos 120º houve valores de correlação abaixo do cutpoint. Em M2, só os 60º do plano sagital não teve valores acima do cutpoint, em M3 apenas os 30º plano sagital não obtiveram valores acima do cut-point, o mesmo acontece para M3 aos 30º plano da omoplata e em M5 aos 30º e 120º no plano frontal. Conclusão: Os resultados deste estudo indicam que a metodologia em causa apresenta elevado grau de fidedignidade inter-observador, já no que toca é fidedignidade intra-observador o grau de semelhança não é tão elevado. Também o erro associado á medida não ultrapassou 1,5cm, sendo considerado baixo. Na validade concorrente concluímos que é aos 0º que a metodologia se torna uma opção válida na aferição das distâncias medidas com uma boa a excelente concordância com o FOB. As medidas consideradas como opções válidas, nas diferentes amplitudes, podem funcionar como parâmetros clínicos de caracterização do posicionamento da omoplata, podendo vir a contribuir ainda para a caracterização da orientação da mesma.-------------------- ABSTRACT:Introduction: The kinematic relationship between the joints of the CAO has great importance in the function of MS, which is why more and more investigated and described. The positioning of the blade gets an important role in understanding the DCAO. There is no doubt the important role of the scapula in the dynamics of MS as well as the positioning of scapular dysfunction as a clinical parameter of the CAO. All these factors create the need to develop tools for evaluating the place of articulation ET. Most assessment tests, restrict its assessment to GU joint disorders, not incorporating a more dynamic and interactive way that respects the theoretical assumptions inherent in the REU. It is also important that the methods are easy to apply clinical and reliably to assess the validity and outcomes. Objectives: To contribute to the development of a methodology for evaluating the scapula in different ranges of MS, through the study of concurrent validity, reliability of intra-and inter-observer. Methodology: The sample consisted of 20 selected elements for convenience, between the body of students of IPS-ESS with no history of dysfunction of the CAO. We performed a kinematic analysis of each subject to MS, using a scanning device for electromagnetic analysis, the FOB. In each subject were also measured, the scapular distances under study, using tape measure. Each method of measuring the time consisted of two (test and retest), in each moment, the measures were collected by two different investigators. Results and Discussion: We considered as positive results that were above the threshold of 0.5, which ranks as a moderate to excellent correlation. The results show that the validity for the researcher in an action M1e M2 was only correlated with moderate to excellent values up to 30º of elevation of the MS. As for M3 only to 30º in the plane of the scapula has the same correlation values near the cutpoint. M4 has no value in correlation with the values of the FOB, and even negative correlation to 120 ° in the plane of the scapula. In M5 show only the values 0 ° correlational excellent to moderate. For investigator 2 in M1 and M2 will be like an investigator, there are only significant correlation values up to 30º of elevation of the MS. As for M3 all the values show excellent correlation to moderate with the exception of 120 ° in the frontal plane. In this researcher M4 has bad results. M5 already in the correlation values are moderate to 0º and 90 º. Regarding the results of ICC intra-observer, we can say that M5 was that these values come closest to the cut point. M1 and M2 are measures which are less than satisfactory results. At 60 ° there are more satisfactory values, followed by 0º and 30º, when we approached the highest levels, such as 90 ° and 120 °, these values tend to decrease. The inter-observer reliability for M1 only to 90 º and 120 ºcorrelation values were below the cutpoint. In M2, only 60 of the sagital plane did not have values above the cutpoint in M3 only 30º sagital plane did not obtain values above the cut-point, the same goes for M3 at 30 ° plane of the scapula and M5 at 30 º and 120 º in frontal plane. Conclusion: The results of this study indicate that the methodology in question has a high degree of inter-observer reliability, as far as intra-observer reliability is the degree of similarity is not as high. Also the error of measure did not exceed 1.5 cm, and is considered low. In concurrent validity conclude that it is at 0 ° the methodology becomes a valid option for the measurement of distances measured with a good to excellent agreement with the FOB. The measures considered as valid options in different amplitudes, can function as clinical parameters to characterize the positioning of the shoulder blade and could further contribute to the characterization of the orientation of the same.