948 resultados para Portable equipment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miniature direct methanol fuel cells (DMFCs) are promising micro power sources for portable appliction. Low temperature cofired ceramic (LTCC), a competitive technology for current MEMS based fabrication, provides cost-effective mass manufacturing route for miniature DMFCs. Porous silver tape is adapted as electrodes to replace the traditional porous carbon electrodes due to its compatibility to LTCC processing and other electrochemical advantages. Electrochemical evaluation of silver under DMFCs operating conditions demonstrated that silver is a good electrode for DMFCs because of its reasonable corrosion resistance, low passivating current, and enhanced catalytic effect. Two catalyst loading methods (cofiring and postfiring) of the platinum and ruthenium catalysts are evaluated for LTCC based processing. The electrochemical analysis exhibits that the cofired path out-performs the postfiring path both at the anode and cathode. The reason is the formation of high surface area precipitated whiskers. Self-constraint sintering is utilized to overcome the difficulties of the large difference of coefficient of thermal expansion (CTE) between silver and LTCC (Dupont 951) tape during cofiring. The graphite sheet employed as a cavity fugitive insert guarantees cavity dimension conservation. Finally, performance of the membrane electrode assembly (MEA) with the porous silver electrode in the regular graphite electrode based cell and the integrated cofired cell is measured under passive fuel feeding condition. The MEA of the regular cell performs better as the electrode porosity and temperature increased. The power density of 10 mWcm-2 was obtained at ambient conditions with 1M methanol and it increased to 16 mWcm -2 at 50°C from an open circuit voltage of 0.58V. For the integrated prototype cell, the best performance, which depends on the balance methanol crossover and mass transfer at different temperatures and methanol concentrations, reaches 1.13 mWcm-2 at 2M methanol solution at ambient pressure. The porous media pore structure increases the methanol crossover resistance. As temperature increased to 60°C, the device increases to 2.14 mWcm-2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are situations in which it is very important to quickly and positively identify an individual. Examples include suspects detained in the neighborhood of a bombing or terrorist incident, individuals detained attempting to enter or leave the country, and victims of mass disasters. Systems utilized for these purposes must be fast, portable, and easy to maintain. The goal of this project was to develop an ultra fast, direct PCR method for forensic genotyping of oral swabs. The procedure developed eliminates the need for cellular digestion and extraction of the sample by performing those steps in the PCR tube itself. Then, special high-speed polymerases are added which are capable of amplifying a newly developed 7 loci multiplex in under 16 minutes. Following the amplification, a postage stamp sized microfluidic device equipped with specially designed entangled polymer separation matrix, yields a complete genotype in 80 seconds. The entire process is rapid and reliable, reducing the time from sample to genotype from 1-2 days to under 20 minutes. Operation requires minimal equipment and can be easily performed with a small high-speed thermal-cycler, reagents, and a microfluidic device with a laptop. The system was optimized and validated using a number of test parameters and a small test population. The overall precision was better than 0.17 bp and provided a power of discrimination greater than 1 in 106. The small footprint, and ease of use will permit this system to be an effective tool to quickly screen and identify individuals detained at ports of entry, police stations and remote locations. The system is robust, portable and demonstrates to the forensic community a simple solution to the problem of rapid determination of genetic identity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exposure to certain bloodborne pathogens can prematurely end a person’s life. Healthcare workers (HCWs), especially those who are members of surgical teams, are at increased risk of exposure to these pathogens. The proper use of personal protective equipment (PPE) during operative/invasive procedures reduces that risk. Despite this, some HCWs fail to consistently use PPE as required by federal regulation, accrediting agencies, hospital policy, and professional association standards. The purpose of this mixed methods survey study was to (a) examine factors surgical team members perceive influence choices of wearing or not wearing PPE during operative/invasive procedures and (b) determine what would influence consistent use of PPE by surgical team members. Using an ex post facto, non-experimental design, the memberships of five professional associations whose members comprise surgical teams were invited to complete a mixed methods survey study. The primary research question for the study was: What differences (perceptual and demographic) exist between surgical team members that influence their choices of wearing or not wearing PPE during operative/invasive procedures? Four principal differences were found between surgical team members. Functional (i.e., profession or role based) differences exist between the groups. Age and experience (i.e., time in profession) differences exist among members of the groups. Finally, being a nurse anesthetist influences the use of risk assessment to determine the level of PPE to use. Four common themes emerged across all groups informing the two study purposes. Those themes were: availability, education, leadership, and performance. Subsidiary research questions examined the influence of previous accidental exposure to blood or body fluids, federal regulations, hospital policy and procedure, leaders’ attitudes, and patients’ needs on the use of PPE. Each of these was found to strongly influence surgical team members and their use of PPE during operative/invasive procedures. Implications based on the findings affect organizational policy, purchasing and distribution decisions, curriculum design and instruction, leader behavior, and finally partnership with PPE manufacturers. Surgical team members must balance their innate need to care for patients with their need to protect themselves. Results of this study will help team members, leaders, and educators achieve this balance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

What is the architecture of transience? What role does architecture play in the impermanent context of the nomad? What form does architecture take when our perception of shelter transforms from fixed and static to flexible and transportable? How does architecture react to the challenges of mobility and change? Traditional building forms speak of stability as an important aspect of architecture. Does portability imply a different building form? During the1950s Buckminister Fuller introduced the idea of mobile, portable structures. In the 1960s Archigrams' examples of architectural nomadism made the mobile home an accepted feature of our contemporary landscape. Currently, new materials and new methods of assembly and transportation open opportunities for rethinking portable architecture. For this thesis, a shelter was developed which provides inhabitable space and portability. The shelter was designed to be easily carried as a backpack. With minimum human effort, the structure is assembled and erected in a few minutes. Although this portable shelter needs to be maneuvered, folded and tucked away for transportation, it does meet the demands of nomadic behavior which emphasizes comfort and portability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electronics industry, is experiencing two trends one of which is the drive towards miniaturization of electronic products. The in-circuit testing predominantly used for continuity testing of printed circuit boards (PCB) can no longer meet the demands of smaller size circuits. This has lead to the development of moving probe testing equipment. Moving Probe Test opens up the opportunity to test PCBs where the test points are on a small pitch (distance between points). However, since the test uses probes that move sequentially to perform the test, the total test time is much greater than traditional in-circuit test. While significant effort has concentrated on the equipment design and development, little work has examined algorithms for efficient test sequencing. The test sequence has the greatest impact on total test time, which will determine the production cycle time of the product. Minimizing total test time is a NP-hard problem similar to the traveling salesman problem, except with two traveling salesmen that must coordinate their movements. The main goal of this thesis was to develop a heuristic algorithm to minimize the Flying Probe test time and evaluate the algorithm against a "Nearest Neighbor" algorithm. The algorithm was implemented with Visual Basic and MS Access database. The algorithm was evaluated with actual PCB test data taken from Industry. A statistical analysis with 95% C.C. was performed to test the hypothesis that the proposed algorithm finds a sequence which has a total test time less than the total test time found by the "Nearest Neighbor" approach. Findings demonstrated that the proposed heuristic algorithm reduces the total test time of the test and, therefore, production cycle time can be reduced through proper sequencing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A man-machine system called teleoperator system has been developed to work in hazardous environments such as nuclear reactor plants. Force reflection is a type of force feedback in which forces experienced by the remote manipulator are fed back to the manual controller. In a force-reflecting teleoperation system, the operator uses the manual controller to direct the remote manipulator and receives visual information from a video image and/or graphical animation on the computer screen. This thesis presents the design of a portable Force-Reflecting Manual Controller (FRMC) for the teleoperation of tasks such as hazardous material handling, waste cleanup, and space-related operations. The work consists of the design and construction of a prototype 1-Degree-of-Freedom (DOF) FRMC, the development of the Graphical User Interface (GUI), and system integration. Two control strategies - PID and fuzzy logic controllers are developed and experimentally tested. The system response of each is analyzed and evaluated. In addition, the concept of a telesensation system is introduced, and a variety of design alternatives of a 3-DOF FRMC are proposed for future development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exposure to certain bloodborne pathogens can prematurely end a person’s life. Healthcare workers (HCWs), especially those who are members of surgical teams, are at increased risk of exposure to these pathogens. The proper use of personal protective equipment (PPE) during operative/invasive procedures reduces that risk. Despite this, some HCWs fail to consistently use PPE as required by federal regulation, accrediting agencies, hospital policy, and professional association standards. The purpose of this mixed methods survey study was to (a) examine factors surgical team members perceive influence choices of wearing or not wearing PPE during operative/invasive procedures and (b) determine what would influence consistent use of PPE by surgical team members. Using an ex post facto, non-experimental design, the memberships of five professional associations whose members comprise surgical teams were invited to complete a mixed methods survey study. The primary research question for the study was: What differences (perceptual and demographic) exist between surgical team members that influence their choices of wearing or not wearing PPE during operative/invasive procedures? Four principal differences were found between surgical team members. Functional (i.e., profession or role based) differences exist between the groups. Age and experience (i.e., time in profession) differences exist among members of the groups. Finally, being a nurse anesthetist influences the use of risk assessment to determine the level of PPE to use. Four common themes emerged across all groups informing the two study purposes. Those themes were: availability, education, leadership, and performance. Subsidiary research questions examined the influence of previous accidental exposure to blood or body fluids, federal regulations, hospital policy and procedure, leaders’ attitudes, and patients’ needs on the use of PPE. Each of these was found to strongly influence surgical team members and their use of PPE during operative/invasive procedures. Implications based on the findings affect organizational policy, purchasing and distribution decisions, curriculum design and instruction, leader behavior, and finally partnership with PPE manufacturers. Surgical team members must balance their innate need to care for patients with their need to protect themselves. Results of this study will help team members, leaders, and educators achieve this balance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this research was to explore a new way of experiencing a performance space using the portability and flexibility of a cargo container. Since the 17th century there has been a split between theater, as a written work, and architecture. Theater has lost its founding essence becoming more about the structure and less about the performance. Contemporary theater designs came through the development of street performances, which developed into theater types such as the Black Box and lately video and projection screening. With the exploration of kinetic uses in architecture and defragmentation of a cargo container there is a new step on the development of theater design. Using a cargo container gave me a familiar object with specific dimensions to start my exploration as well as the possibility of having the theater transported to many sites. The findings demonstrate that there are many unexplored possibilities to create a performance space outside the conventional theater that can promote new types of performances as well as the use of new technologies of video and projection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Obstructive airway diseases (OADs) are among the leading causes of morbidity and mortality worldwide. Shortness of breath (SOB) is the main symptom associated with OADs. International guidelines from the Global Initiative for Chronic Lung Disease (GOLD) and the Global Initiative for Asthma (GINA) have recommended spirometry as an indispensable tool for the diagnosis of asthma and chronic obstructive pulmonary diseases (COPD), but spirometry is rarely used in family practice. Simple and reliable diagnostic tools are necessary for screening community patients with onset of OADs for timely management. Purpose: This thesis examined screening utility of the PiKo-6 forced expiratory volume in one second (pFEV₁) , in six second (pFEV₆), and the pRatio ( pFEV₁/pFEV₆) in SOB patients for OADs in community pharmacy settings. FEV₆ has recently been suggested an excellent surrogate for Forced Vital Capacity (FVC), which requires maximum exhalation of the lungs. Methods: Patients with SOB symptoms who were prescribed pulmonary inhalers, by their family physicians, were recruited via community pharmacies. Trained pharmacists collected two PiKo-6 tests to assess the repeatability of the PiKo-6 device. All patients performed laboratory spirometry ( FEV₁, FVC and FEV₁/FVC) to obtain physician diagnosis of their OADs. The results of the PiKo-6 spirometer and laboratory spirometer were compared. In addition, the PiKo-6 pRatio and laboratory FEV₁/FVC were assessed against physician diagnosed COPD. Results: Sixty three patients volunteered to perform the PiKo-6 spirometry. Of these, 52.4 % were men (age 53.9 ± 15.3 years; BMI 31.9 ± 7.40 kg/m2). Repeated testing with pFEV₁, pFEV6 and pRatio correlated significantly (within correlation, r = 0.835, p-Value≤ 0.05 ; 0.872, p- Value≤ 0.05; and 0.664, p-Value≤ 0.05). In addition, pFEV₁, pFEV6 and pRatio correlated significantly with FEV₁, FVC and FEV₁/FVC, respectively (between correlation = 0.630, p- Value≤ 0.05 ; 0.660, p-Value≤ 0.05 and 0.580, p-Value≤ 0.05). The cut-off value corresponding to the greatest sum of sensitivity and specificity of pRatio for physician-diagnosed COPD was <0.80, the sensitivity and specificity were 84 % and 50%, respectively. Conclusions The portable PiKo-6 correlates moderately well with the standard spirometry, when delivered by community pharmacists to patients with OADs. The PiKo-6 spirometer may play a role in screening patients suspected of having an OAD in community pharmacies that may benefit from early physician diagnosis and appropriate management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Underground hardrock mining can be very energy intensive and in large part this can be attributed to the power consumption of underground ventilation systems. In general, the power consumed by a mine’s ventilation system and its overall scale are closely related to the amount of diesel power in operation. This is because diesel exhaust is a major source of underground air pollution, including diesel particulate matter (DPM), NO2 and heat, and because regulations tie air volumes to diesel engines. Furthermore, assuming the size of airways remains constant, the power consumption of the main system increases exponentially with the volume of air supplied to the mine. Therefore large diesel fleets lead to increased energy consumption and can also necessitate large capital expenditures on ventilation infrastructure in order to manage power requirements. Meeting ventilation requirements for equipment in a heading can result in a similar scenario with the biggest pieces leading to higher energy consumption and potentially necessitating larger ventilation tubing and taller drifts. Depending on the climate where the mine is located, large volumes of air can have a third impact on ventilation costs if heating or cooling the air is necessary. Annual heating and cooling costs, as well as the cost of the associated infrastructure, are directly related to the volume of air sent underground. This thesis considers electric mining equipment as a means for reducing the intensity and cost of energy consumption at underground, hardrock mines. Potentially, electric equipment could greatly reduce the volume of air needed to ventilate an entire mine as well as individual headings because they do not emit many of the contaminants found in diesel exhaust and because regulations do not connect air volumes to electric motors. Because of the exponential relationship between power consumption and air volumes, this could greatly reduce the amount of power required for mine ventilation as well as the capital cost of ventilation infrastructure. As heating and cooling costs are also directly linked to air volumes, the cost and energy intensity of heating and cooling the air would also be significantly reduced. A further incentive is that powering equipment from the grid is substantially cheaper than fuelling them with diesel and can also produce far fewer GHGs. Therefore, by eliminating diesel from the underground workers will enjoy safer working conditions and operators and society at large will gain from a smaller impact on the environment. Despite their significant potential, in order to produce a credible economic assessment of electric mining equipment their impact on underground systems must be understood and considered in their evaluation. Accordingly, a good deal of this thesis reviews technical considerations related to the use of electric mining equipment, especially ones that impact the economics of their implementation. The goal of this thesis will then be to present the economic potential of implementing the equipment, as well as to outline the key inputs which are necessary to support an evaluation and to provide a model and an approach which can be used by others if the relevant information is available and acceptable assumptions can be made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the prohibition of the use of radioactive lightning conductor in Brazil, this material passed to be collected and stored as radioactive waste in the waste deposits of The Brazilian National Nuclear Energy Commission (CNEN). The majority of these lightning conductor used as radioactive source 241Am with activity varying of 1 the 5 mCi. In this work are presented preliminary studies by recovering of 241Am through the electroplating technique, in order to posterior use as sources to portable X-rays fluorescence spectrometer. The 241Am sources have been removed from lightning conductor and dissolved in acid solution. The solution presented an activity of 0,6 Ci L-1. Small amounts of this solution were added to some electrolytes and tested in order to evaluate optimum electrolyte for deposition of 241Am. It was studied as electrolytes: HNO3 (0,2 mol L-1), NH4Cl (5,0 mol L-1) and a mixture of KCN and K2CO3 (in the rate of 2,0 g of each per liter). Yields of up to 90% were obtained applied a current density of 50 mA cm-2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sampling the total air concentration of particulate matter (PM) only provides a basic estimate of exposure that normally not allows correlating with the observed health effects. Therefore is of great importance to recognize the particles size distribution and, particularly, the exposure to fine particles (≤ 2.5 μm). This particles dimension corresponds to the respirable fraction, the one that can implicate local and systemic effects due to particle deposition and clearance from the lungs and transport within the organism. This study intended to describe occupational exposure to PM2.5 in three units related with swine production and consumption, namely: feed production, swine production and swine slaughterhouse. A size-selective particle measuring in five to six workplaces of each unit was performed. Measurements of PM were done using a portable direct-reading hand-held equipment (Lighthouse, model 3016 IAQ). Data showed slaughterhouse unit with higher values, with values ranging from 0.030 to 0.142 mg/m3 (0.073 + 0.043), being the cutting room the workplace with higher values. In feed production unit, values were between 0.026 and 0.033 mg/m3 (0.028 + 0.003) with the warehouse of pharmacy products as the workplace with higher values. Finally, in swine unit values ranged from 0.006 to 0.048 mg/m3 (0.023 + 0.017) with the batteries area presenting the higher values. PM can be rich in fungi and bacteria and their metabolites, such as endotoxins and mycotoxins. Previous publications already showed high contamination in these occupational settings and particles can have an important role in exposure since can easily act as carrier of these agents. Data acquired allow not only a better prediction of particle penetration into respiratory regions of the respiratory tract, but also a better estimation of PM health effects. Moreover, data permit to identify the workplaces where investment should be made to prevent and reduce exposure.