Preparation of Excitation Sources to Portable X-Ray Spectrometer by Recovering 241am from Radioactive Lightning Conductor


Autoria(s): ARAÚJO, Valeska Peres de; SOUSA, Alvaro Serafim Ferreira de; BRANDÃO, Luis Eduardo Barreira
Data(s)

09/08/2016

09/08/2016

2007

Resumo

With the prohibition of the use of radioactive lightning conductor in Brazil, this material passed to be collected and stored as radioactive waste in the waste deposits of The Brazilian National Nuclear Energy Commission (CNEN). The majority of these lightning conductor used as radioactive source 241Am with activity varying of 1 the 5 mCi. In this work are presented preliminary studies by recovering of 241Am through the electroplating technique, in order to posterior use as sources to portable X-rays fluorescence spectrometer. The 241Am sources have been removed from lightning conductor and dissolved in acid solution. The solution presented an activity of 0,6 Ci L-1. Small amounts of this solution were added to some electrolytes and tested in order to evaluate optimum electrolyte for deposition of 241Am. It was studied as electrolytes: HNO3 (0,2 mol L-1), NH4Cl (5,0 mol L-1) and a mixture of KCN and K2CO3 (in the rate of 2,0 g of each per liter). Yields of up to 90% were obtained applied a current density of 50 mA cm-2.

Identificador

http://carpedien.ien.gov.br:8080/handle/ien/1800

Idioma(s)

eng

Publicador

Instituto de Engenharia Nuclear

Brasil

IEN

Direitos

openAccess

Palavras-Chave #Electroplating #X-Ray Spectrometer #Lightning
Tipo

conferenceObject