954 resultados para Parallel computers - Design and construction
Resumo:
The inclusion of the Discrete Wavelet Transform in the JPEG-2000 standard has added impetus to the research of hardware architectures for the two-dimensional wavelet transform. In this paper, a VLSI architecture for performing the symmetrically extended two-dimensional transform is presented. This architecture conforms to the JPEG-2000 standard and is capable of near-optimal performance when dealing with the image boundaries. The architecture also achieves efficient processor utilization. Implementation results based on a Xilinx Virtex-2 FPGA device are included.
Resumo:
We describe the rationale for disease specific research networks in general as well as the aims and function of the European Cystic Fibrosis Society-Clinical Trials Network (ECFS-CTN) specifically. The ECFS-CTN was founded in 2009 with the aim of improving the quality and quantity of clinical research in the area of cystic fibrosis (CF) in Europe. A network of 18 clinical trial sites in 8 European countries was established according to uniform state-of-the-art quality criteria. To support the ECFS-CTN in the acquisition, planning and conduct of clinical trials, the network is equipped with a coordinating centre, steering and executive committees, and committees for protocol review, standardization, training and networking as well as a data safety monitoring board. A strong partnership with European CF patient parent organizations aims to increase awareness of the need for efficient clinical research and the participation of patients in clinical trials.
Resumo:
Elevated intraocular pressure (IOP) is a major risk factor for the deterioration of open-angle glaucoma (OAG); medical IOP reduction is the standard treatment, yet no randomized placebo-controlled study of medical IOP reduction has been undertaken previously. The United Kingdom Glaucoma Treatment Study (UKGTS) tests the hypothesis that treatment with a topical prostaglandin analog, compared with placebo, reduces the frequency of visual field (VF) deterioration events in OAG patients by 50% over a 2-year period.
Resumo:
In linear cascade wind tunnel tests, a high level of pitchwise periodicity is desirable to reproduce the azimuthal periodicity in the stage of an axial compressor or turbine. Transonic tests in a cascade wind tunnel with open jet boundaries have been shown to suffer from spurious waves, reflected at the jet boundary, that compromise the flow periodicity in pitch. This problem can be tackled by placing at this boundary a slotted tailboard with a specific wall void ratio s and pitch angle a. The optimal value of the s-a pair depends on the test section geometry and on the tunnel running conditions. An inviscid two-dimensional numerical method has been developed to predict transonic linear cascade flows, with and without a tailboard, and quantify the nonperiodicity in the discharge. This method includes a new computational boundary condition to model the effects of the tailboard slots on the cascade interior flow. This method has been applied to a six-blade turbine nozzle cascade, transonically tested at the University of Leicester. The numerical results identified a specific slotted tailboard geometry, able to minimize the spurious reflected waves and regain some pitchwise flow periodicity. The wind tunnel open jet test section was redesigned accordingly. Pressure measurements at the cascade outlet and synchronous spark schlieren visualization of the test section, with and without the optimized slotted tailboard, have confirmed the gain in pitchwise periodicity predicted by the numerical model. Copyright © 2006 by ASME.
Resumo:
This paper presents the design and implementation of a measurement-based QoS and resource management framework, CNQF (Converged Networks’ QoS Management Framework). CNQF is designed to provide unified, scalable QoS control and resource management through the use of a policy-based network
management paradigm. It achieves this via distributed functional entities that are deployed to co-ordinate the resources of the transport network through centralized policy-driven decisions supported by measurement-based control architecture. We present the CNQF architecture, implementation of the
prototype and validation of various inbuilt QoS control mechanisms using real traffic flows on a Linux-based experimental test bed.
Resumo:
The School of Mechanical and Aerospace Engineering at Queen’s University Belfast started BEng and MEng degree programmes in Product Design and Development (PDD) in 2004. Intended from the outset to be significantly different from the existing programmes within the School the PDD degrees used the syllabus and standards defined by the CDIO Initiative as the basis for an integrated curriculum. Students are taught in the context of conceiving, designing, implementing and operating a product. Fundamental to this approach is a core sequence of Design-Build-Test (DBT) experiences which facilitates the development of a range of professional skills as well as the immediate application of technical knowledge gained in strategically aligned supporting modules.
The key objective of the degree programmes is to better prepare students for professional practice. PDD graduates were surveyed using a questionnaire developed by the CDIO founders and interviewed to examine the efficacy of these degree programmes, particularly in this key objective. Graduate employment rates, self assessment of graduate attributes and examples of work produced by MEng graduates provided positive evidence that their capabilities met the requirements of the profession. The 24% questionnaire response rate from the 96 graduates to date did not however facilitate statistically significant conclusions to be drawn and particularly not for BEng graduates who were under represented in the response group. While not providing proof of efficacy the investigation did provide a good amount of useful data for consideration as part of a continuous improvement process.
Resumo:
There is a requirement for better integration between design and analysis tools, which is difficult due to their different objectives, separate data representations and workflows. Currently, substantial effort is required to produce a suitable analysis model from design geometry. Robust links are required between these different representations to enable analysis attributes to be transferred between different design and analysis packages for models at various levels of fidelity.
This paper describes a novel approach for integrating design and analysis models by identifying and managing the relationships between the different representations. Three key technologies, Cellular Modeling, Virtual Topology and Equivalencing, have been employed to achieve effective simulation model management. These technologies and their implementation are discussed in detail. Prototype automated tools are introduced demonstrating how multiple simulation models can be linked and maintained to facilitate seamless integration throughout the design cycle.
Resumo:
Objectives: To determine, by means of static fracture testing the effect of the tooth preparation design and the elastic modulus of the cement on the structural integrity of the cemented machined ceramic crown-tooth complex.
Methods: Human maxillary extracted premolar teeth were prepared for all-ceramic crowns using two preparation designs; a standard preparation in accordance with established protocols and a novel design with a flat occlusal design. All-ceramic feldspathic (Vita MK II) crowns were milled for all the preparations using a CAD/CAM system (CEREC-3). The machined all-ceramic crowns were resin bonded to the tooth structure using one of three cements with different elastic moduli: Super-Bond C&B, Rely X Unicem and Panavia F 2.0. The specimens were subjected to compressive force through a 4 mm diameter steel ball at a crosshead speed of 1 mm/min using a universal test machine (Loyds Instrument Model LRX.). The load at the fracture point was recorded for each specimen in Newtons (N). These values were compared to a control group of unprepared/unrestored teeth.
Results: There was a significant difference between the control group, with higher fracture strength, and the cemented samples regardless of the occlusal design and the type of resin cement. There was no significant difference in mean fracture load between the two designs of occlusal preparation using Super-Bond C&B. For the Rely X Unicem and Panavia F 2.0 cements, the proposed preparation design with a flat occlusal morphology provides a system with increased fracture strength.
Significance: The proposed novel flat design showed less dependency on the resin cement selection in relation to the fracture strength of the restored tooth. The choice of the cement resin, with respect to its modulus of elasticity, is more important in the anatomic design than in the flat design. © 2013 Academy of Dental Materials.
Resumo:
The effect of preparation design and the physical properties of the interface lute on the restored machined ceramic crown-tooth complex are poorly understood. The aim of this work was to determine, by means of three-dimensional finite element analysis (3D FEA) the effect of the tooth preparation design and the elastic modulus of the cement on the stress state of the cemented machined ceramic crown-tooth complex. The three-dimensional structure of human premolar teeth, restored with adhesively cemented machined ceramic crowns, was digitized with a micro-CT scanner. An accurate, high resolution, digital replica model of a restored tooth was created. Two preparation designs, with different occlusal morphologies, were modeled with cements of 3 different elastic moduli. Interactive medical image processing software (mimics and professional CAD modeling software) was used to create sophisticated digital models that included the supporting structures; periodontal ligament and alveolar bone. The generated models were imported into an FEA software program (hypermesh version 10.0, Altair Engineering Inc.) with all degrees of freedom constrained at the outer surface of the supporting cortical bone of the crown-tooth complex. Five different elastic moduli values were given to the adhesive cement interface 1.8 GPa, 4 GPa, 8 GPa, 18.3 GPa and 40 GPa; the four lower values are representative of currently used cementing lutes and 40 GPa is set as an extreme high value. The stress distribution under simulated applied loads was determined. The preparation design demonstrated an effect on the stress state of the restored tooth system. The cement elastic modulus affected the stress state in the cement and dentin structures but not in the crown, the pulp, the periodontal ligament or the cancellous and cortical bone. The results of this study suggest that both the choice of the preparation design and the cement elastic modulus can affect the stress state within the restored crown-tooth complex.