991 resultados para PROSTHESIS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Total knee replacement is the gold standard treatment for patients suffering from advanced symptomatic knee osteoarthritis. The main goals of knee prosthetics are pain reduction and restoration of knee motion. The new prostheses on the market such as the bi-cruciate stabilized Journey knee implant, promise a reconstruction of total physiological function of the knee with physiological range of motion and therefore high patient satisfaction. Purpose: The aim of this study was to analyze the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS) outcome after total knee replacement with new physiological bi-cruciate stabilized Journey knee prosthesis. Study Design: Prospective, consecutive case-series. Patients: Ninety nine patients, who received bi-cruciate stabilized Journey total knee prosthesis between January 1st 2006 and May 31st 2012, were included in the study. A single surgeon operated all patients. There were 61.1% females and the overall average age was 68 years (range 41-83 years). Left knee was replaced in 55.6%. Methods: The patients filled in KOO’s questionnaire pre- and 1 year postoperative. Range of motion (ROM) was studied preoperatively and at 1-year follow-ups. The pre- and postoperative KOOS subscores and ROM were compared using the Wilcoxon signed rank test. Results: There are significant improvements of all KOOS subscores. Ninety percent of patients have reached the minimum clinically relevant 10 points in symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sport and recreation, and 90% in knee related quality of life. Postoperative, the average passive ROM was 131° (range 110-145°) and the average active ROM 122° (range 105-135°). The highest correlation coefficients ROM and the KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore. Conclusions: Bi-cruciate stabilized knee prosthetic offers a solid outcome 1 year postoperative based on the results measured with the KOOS evaluation questionnaire. The Patients showed a generalized improvement in all domains measured in the KOOS of minimally 35, and up to over 52 points, what can be described as statistically significant. Patients described the level of functionality close to double compared to the preoperative status.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND AIM So far there is little evidence from randomised clinical trials (RCT) or systematic reviews on the preferred or best number of implants to be used for the support of a fixed prosthesis in the edentulous maxilla or mandible, and no consensus has been reached. Therefore, we reviewed articles published in the past 30 years that reported on treatment outcomes for implant-supported fixed prostheses, including survival of implants and survival of prostheses after a minimum observation period of 1 year. MATERIAL AND METHODS MEDLINE and EMBASE were searched to identify eligible studies. Short and long-term clinical studies were included with prospective and retrospective study designs to see if relevant information could be obtained on the number of implants related to the prosthetic technique. Articles reporting on implant placement combined with advanced surgical techniques such as sinus floor elevation (SFE) or extensive grafting were excluded. Two reviewers extracted the data independently. RESULTS A primary search was broken down to 222 articles. Out of these, 29 studies comprising 26 datasets fulfilled the inclusion criteria. From all studies, the number of planned and placed implants was available. With two exceptions, no RCTs were found, and these two studies did not compare different numbers of implants per prosthesis. Eight studies were retrospective; all the others were prospective. Fourteen studies calculated cumulative survival rates for 5 and more years. From these data, the average survival rate was between 90% and 100%. The analysis of the selected articles revealed a clear tendency to plan 4 to 6 implants per prosthesis. For supporting a cross-arch fixed prosthesis in the maxilla, the variation is slightly greater. CONCLUSIONS In spite of a dispersion of results, similar outcomes are reported with regard to survival and number of implants per jaw. Since the 1990s, it was proven that there is no need to install as many implants as possible in the available jawbone. The overwhelming majority of articles dealing with standard surgical procedures to rehabilitate edentulous jaws uses 4 to 6 implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article provides an overview on procedure-related issues and uncertainties in outcomes after transcatheter aortic valve implantation (TAVI). The different access sites and how to select them in an individual patient are discussed. Also, the occurrence and potential predictors of aortic regurgitation (AR) after TAVI are addressed. The different methods to quantify AR are reviewed, and it appears that accurate and reproducible quantification is suboptimal. Complications such as prosthesis-patient mismatch and conduction abnormalities (and need for permanent pacemaker) are discussed, as well as cerebrovascular events, which emphasize the development of optimal anti-coagulative strategies. Finally, recent registries have shown the adoption of TAVI in the real world, but longer follow-up studies are needed to evaluate the outcome (but also prosthesis durability). Additionally, future studies are briefly discussed, which will address the use of TAVI in pure AR and lower-risk patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An exponential increase in the use of transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis has been witnessed over the recent years. The current article reviews different areas of uncertainty related to patient selection. The use and limitations of risk scores are addressed, followed by an extensive discussion on the value of three-dimensional imaging for prosthesis sizing and the assessment of complex valve anatomy such as degenerated bicuspid valves. The uncertainty about valvular stenosis severity in patients with a mismatch between the transvalvular gradient and the aortic valve area, and how integrated use of echocardiography and computed tomographic imaging may help, is also addressed. Finally, patients referred for TAVI may have concomitant mitral regurgitation and/or coronary artery disease and the management of these patients is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Objectives We report our institutional experience and long-term results with the Sorin Freedom SOLO bovine pericardial stentless bioprosthesis. Methods Between January 2005 and November 2009, 149 patients (mean age 73.6±8.7 years, 68 [45.6%] female) underwent isolated (n=75) or combined (n=74) aortic valve replacement (AVR) using the SOLO in our institution. Follow-up was 100% complete with an average follow-up time of 5.9±2.6 years (maximum 9.6 years) and a total of 885.3 patient years. Results Operative (30-day) mortality was 2.7% (1.3% for isolated AVR [n=1] and 4.0% for combined procedures [n=3]). All causes of death were not valve-related. Preoperative peak (mean) gradients of 74.2±23.0 mmHg (48.6 ± 16.3 mmHg) decreased to 15.6±5.4 (8.8±3.0) after AVR, and remained low for up to 9 years. The postoperative effective orifice area (EOA) was 1.6 ±0.57 cm2, 1.90±0.45 cm2, 2.12±0.48 cm2 and 2.20±0.66 cm2 for the valve sizes 21, 23, 25 and 27, respectively; with absence of severe prosthesis-patient-mismatch (PPM) and 0.7% (n=1) moderate PPM. During follow-up, Twenty-six patients experienced structural valve deterioration (SVD) and 14 patients underwent explantation. Kaplan-Meier estimates for freedom from death, explantation and SVD at 9 years averaged 0.57 [0.47‒0.66], 0.82 [0.69‒0.90] and 0.70 [0.57‒0.79], respectively. Conclusions The Freedom SOLO stentless aortic valve is safe to implant and shows excellent early and mid-term hemodynamic performance. However, SVD was observed in a substantial number of patients after only 5 ̶ 6 years and the need for explantation increased markedly, suggesting low durability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The Sorin Freedom SOLO (FS) bovine pericardial stentless valve prosthesis is designed for supraannular, subcoronary implantation. We report our experience and results with 277 consecutively implanted FS bioprostheses. METHODS 277 patients (mean age, 74.2 ± 7.3 years; 139 (50.2%) female) underwent aortic valve replacement (AVR) with the FS stentless bioprosthesis. The hemodynamic performance was investigated with transthoracic echocardiography at discharge, 6 months later, and yearly thereafter. Follow-up was 100% complete, with an average observation time of 2.6 ± 1.7 years and a total of 697.3 patient-years. RESULTS The overall 30-day mortality was 4.3%. The mortalities for isolated AVR and combined procedures were 1.9% and 7.3%, respectively. No causes of death were valve-related. Preoperative peak (74.2 ± 23.0 mm Hg) and mean (48.6 ± 16.3 mm Hg) gradients decreased to 15.6 ± 5.4 mm Hg and 8.8 ± 3.0 mm Hg postoperatively and remained unchanged for as long as 5 years. The postoperative mean effective orifice area (EOA) for valve sizes 19, 21, 23, 25, and 27 were 1.49 ± 0.32 cm(2), 1.67 ± 0.40 cm(2), 1.92 ± 0.38 cm(2), 2.01 ± 0.42 cm(2), and 2.13 ± 0.36 cm(2), respectively. Severe prosthesis-patient mismach (PPM) was completely absent, and moderate PPM occurred in 17 patients (6.1%). In isolated AVR, 0.8% of patients with preoperative sinus rhythm required a permanent pacemaker before hospital discharge. There was 100% freedom from structural valve deterioration, 99.6 % freedom from endocarditis and reoperation, and 97.3% freedom from thromboembolism at 5 years. CONCLUSIONS The FS stentless aortic valve is safe to implant, and it shows excellent hemodynamic performance and early and midterm results. Owing to the favorable EOA, the valve appears particularly attractive for patients at risk for PPM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE OF REVIEW There is controversy regarding the optimal choice of prosthetic valves in patients less than 65 years of age requiring mitral valve replacement (MVR). Recently, trends for valve replacement are moving towards biological prosthesis also in younger patients, which is justified by the fact that a later valve-in-valve procedure is feasible in the case of degeneration of the tissue valve. This strategy is increasingly recommended in aortic valve surgery but is questionable for MVR. The purpose of this review is to evaluate current guidelines and analyse evidence for biological MVR in patients under 65 years. RECENT FINDINGS There are differences between guidelines of the American Heart Association and those of the European Society of Cardiology concerning the choice of prostheses in patients undergoing MVR. Although the European Society of Cardiology recommends a mechanical mitral valve in patients under 65 years of age, the American Heart Association does not provide detailed advice for these patients. Mitral valve replacement with biological valves in patients under 65 years is associated with higher rates of reoperation due to structural valve deterioration. In addition, several studies showed a decreased survival after biological MVR. SUMMARY Evidence for biological MVR in patients less than 65 years without comorbidities or contraindication for oral anticoagulation does not exist. Recommendations for patients less than 65 years of age should not be blurred by current 'en-vogue' methods for promising but not yet proven valve-in-valve strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The Perceval (Sorin Group, Milan, Italy) is a self-anchoring sutureless aortic valve prosthesis. We report the short- to midterm results of combined aortic valve replacement (AVR) with concomitant procedures in elderly patients undergoing operation as part of 3 consecutive prospective multicenter European studies. METHODS From April 2007 to February 2013, 243 patients (mean age, 79.7 ± 5.1 years; female patients, 61%; median EuroSCORE, 9%) underwent AVR with concomitant procedures. The concomitant procedures were coronary artery bypass grafting (CABG) (182 cases), septal myectomy (21 cases), CABG + other procedures (18 cases), and 22 other procedures. Primary and secondary end points included implant feasibility and safety (for mortality and morbidity) and efficacy (New York Heart Association [NYHA] class improvement and hemodynamic results) of the prosthesis at the different follow-up periods. Data were expressed as mean ± standard deviation. Kaplan-Meier analysis was performed for survival analysis. RESULTS Mean aortic cross-clamp and extracorporeal circulation (ECC) times were 50.7 ± 22.8 minutes and 78.9 ± 32.3 minutes, respectively. Thirty-day mortality was 2.1%. Mean postoperative gradient and effective orifice area were 10.1 ± 4.7 mm Hg and 1.5 ± 0.4 cm(2) and 8.9 ± 5.6 mm Hg and 1.6 ± 0.4 cm(2), respectively, at 1 year. There were early explantations, 4 of which resulted from paravalvular leaks. One additional valve explantation resulted from aortic root bleeding, probably caused by excessively extensive decalcification. In the late period, there was 1 mild paravalvular leak and no intravalvular insufficiency. No migration, dislodgement, or degeneration of the valve occurred during follow-up. Median follow-up was 444 days. CONCLUSIONS These trials confirm the safety and efficacy of the Perceval sutureless aortic valve, especially in elderly patients requiring AVR + concomitant procedures. In this patient group, sutureless valves may be advantageous compared to transcatheter valve implantations as concomitant procedures other than percutaneous coronary artery angioplasty are not always possible in the latter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A retrospective evaluation of glass ionomer cement (GIC) in middle ear surgery with emphasis on short- and long-term safety was conducted at the tertiary referral center. GIC was applied between 1995 and 2006 in 444 patients in otologic surgery. Technical aspects, safety, benefits and complications due to GIC were analysed until 2011 (follow-up 5-16 years; mean 10 years). GIC was applied in stapes surgery (228 primary, 92 revisions), cochlear implants (108) and implantable hearing aids (7), ossiculoplasty (7), for coverage of opened mastoid air cells towards the external ear canal (1) and inner ear fistula closure (1). GIC turned out to be very handy in stapes surgery for optimal prosthesis fixation at the incus (260) and on the malleus handle (60) without complications. Results suggest that GIC may diminish the danger of incus necrosis in primary stapedotomy. In cochlear implants and implantable hearing aids, GIC was used for casing alone (74), casing and electrode fixation (27) and electrode alone fixation (14). Inflammatory reactions were observed in five cases (4.3 %), mostly after trauma. Broken cement fragments appeared to promote foreign body rejection. In seven cases an incudo-stapedial gap was repaired with GIC with excellent hearing gain; in three cases (43 %) revision surgery was needed due to cement breakage. In one case, GIC was applied for a watertight coverage of opened mastoid cells, and in the other for fistula closure of the lateral semi-circular canal over cartilage, covered with bone pathé; follow-up was uneventful. Targeted use of GIC in middle ear surgery rarely poses problems. GIC cannot be used in neuro-otosurgery in contact with cerebrospinal fluid because of possible aluminium encephalopathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The main goals of the standard treatment for advanced symptomatic knee osteoarthritis, total knee arthroplasty (TKA), are pain reduction and restoration of knee motion.The aim of this study was to analyse the outcome of the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS), and the surgeon-based Knee Society Score (KSS) and its Knee Score (KS) and Knee Functional Score (KFS) components after (TKA) using the Journey knee prosthesis, and to assess the correlation of these scores with range of motion (ROM). METHODS In a prospective case series study between August 1st 2008 and May 31st 2011, 99 patients, all operated by a single surgeon, received Journey bicruciate stabilized total knee prostheses. The female/male ratio was 53/34, the mean patient age at surgery was 68 years (range 41-83 years), and the left/right knee ratio was 55/44. The KOOS, range of motion, and KS and KFS were obtained preoperatively and at 1-year follow-up. The pre- and postoperative levels of the outcome measures were compared using the Wilcoxon signed-rank test. Correlation between ROM and patient outcomes was analysed with the Spearman coefficient. RESULTS All KOOS subscores improved significantly. Ninety percent of patients improved by at least the minimum clinically relevant difference of 10 points in stiffness and other symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sports and recreation, and 90% in knee-related quality of life. The mean passive and active ROM improved from 122.4° (range 90-145°) and 120.4° (range 80-145°) preoperatively to 129.4° (range 90-145°) and 127.1° (range 100-145°) postoperatively. The highest correlation coefficients for ROM and KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore.There was a significant and clinically relevant improvement of KSS (preop/postop 112.2/174.5 points), and its KS (preop/postop 45.6/86.8 points) and KFS (preop/postop 66.6/87.8 points) components. CONCLUSIONS The Journey bicruciate stabilized knee prosthesis showed good 1-year postoperative results in terms of both functional and patient-based outcome. However, higher knee ROM correlates only moderately with patient-based outcome, implying that functionality afforded by the Journey bicruciate TKA is not equivalent to patient satisfaction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Transcatheter aortic valve implantation (TAVI) is routinely performed via the transfemoral and the transapical route. Subclavian and direct aortic access are described alternatives for TAVI. Recently, the transcarotid approach has been shown to be feasible among patients with limited vascular access and severe native aortic valve stenosis. We aim to investigate the feasibility of transcatheter aortic valve-in-valve implantation via the transcarotid access in patients with severe aortic regurgitation due to degenerated stentless Shelhigh conduits using the 29 mm Medtronic CoreValve bioprosthesis. METHODS Three patients with complex vascular anatomy undergoing transcatheter valve-in-valve implantation via the transcarotid route were enrolled in the study. The procedure was performed under general anaesthesia using surgical cut-down to facilitate vascular access. Immediate procedural results as well as echocardiographic and clinical outcomes after 30 days and 6 months of the follow-up were recorded and analysed. RESULTS All three patients underwent unproblematic TAVI and experienced dramatic improvement of symptoms. Mean transvalvular gradient was 3, 6 and 11 mmHg, respectively. Effective orifice area ranged between 1.7 and 2.2 cm(2). Only mild paravalvular regurgitation was detected by echocardiography after 30 days of the follow-up. CONCLUSIONS The transcarotid approach can be safely performed for valve-in-valve procedures using the Medtronic CoreValve in patients with limited vascular access. It enables accurate positioning and implantation of the prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to directly compare metal artifact reduction (MAR) of virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (CT) with iterative MAR (iMAR) from single energy in pelvic CT with hip prostheses. MATERIALS AND METHODS A human pelvis phantom with unilateral or bilateral metal inserts of different material (steel and titanium) was scanned with third-generation dual-source CT using single (120 kVp) and dual-energy (100/150 kVp) at similar radiation dose (CT dose index, 7.15 mGy). Three image series for each phantom configuration were reconstructed: uncorrected, VME, and iMAR. Two independent, blinded radiologists assessed image quality quantitatively (noise and attenuation) and subjectively (5-point Likert scale). Intraclass correlation coefficients (ICCs) and Cohen κ were calculated to evaluate interreader agreements. Repeated measures analysis of variance and Friedman test were used to compare quantitative and qualitative image quality. Post hoc testing was performed using a corrected (Bonferroni) P < 0.017. RESULTS Agreements between readers were high for noise (all, ICC ≥ 0.975) and attenuation (all, ICC ≥ 0.986); agreements for qualitative assessment were good to perfect (all, κ ≥ 0.678). Compared with uncorrected images, VME showed significant noise reduction in the phantom with titanium only (P < 0.017), and iMAR showed significantly lower noise in all regions and phantom configurations (all, P < 0.017). In all phantom configurations, deviations of attenuation were smallest in images reconstructed with iMAR. For VME, there was a tendency toward higher subjective image quality in phantoms with titanium compared with uncorrected images, however, without reaching statistical significance (P > 0.017). Subjective image quality was rated significantly higher for images reconstructed with iMAR than for uncorrected images in all phantom configurations (all, P < 0.017). CONCLUSIONS Iterative MAR showed better MAR capabilities than VME in settings with bilateral hip prosthesis or unilateral steel prosthesis. In settings with unilateral hip prosthesis made of titanium, VME and iMAR performed similarly well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Implant-overdentures supported by rigid bars provide stability in the edentulous atrophic mandible. However, fractures of solder joints and matrices, and loosening of screws and matrices were observed with soldered gold bars (G-bars). Computer-aided designed/computer-assisted manufactured (CAD/CAM) titanium bars (Ti-bars) may reduce technical complications due to enhanced material quality. PURPOSE To compare prosthetic-technical maintenance service of mandibular implant-overdentures supported by CAD/CAM Ti-bar and soldered G-bar. MATERIALS AND METHODS Edentulous patients were consecutively admitted for implant-prosthodontic treatment with a maxillary complete denture and a mandibular implant-overdenture connected to a rigid G-bar or Ti-bar. Maintenance service and problems with the implant-retention device complex and the prosthesis were recorded during minimally 3-4 years. Annual peri-implant crestal bone level changes (ΔBIC) were radiographically assessed. RESULTS Data of 213 edentulous patients (mean age 68 ± 10 years), who had received a total of 477 tapered implants, were available. Ti-bar and G-bar comprised 101 and 112 patients with 231 and 246 implants, respectively. Ti-bar mostly exhibited distal bar extensions (96%) compared to 34% of G-bar (p < .001). Fracture rate of bars extensions (4.7% vs 14.8%, p < .001) and matrices (1% vs 13%, p < .001) was lower for Ti-bar. Matrices activation was required 2.4× less often in Ti-bar. ΔBIC remained stable for both groups. CONCLUSIONS Implant overdentures supported by soldered gold bars or milled CAD/CAM Ti-bars are a successful treatment modality but require regular maintenance service. These short-term observations support the hypothesis that CAD/CAM Ti-bars reduce technical complications. Fracture location indicated that the titanium thickness around the screw-access hole should be increased.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Periazetabuläre Frakturen bei Hüftprothesen nehmen aufgrund der Überalterung und der zunehmenden Aktivität alter Menschen zu. Die periprothetischen Azetabulumfrakturen werden anhand der Einteilung von Letournel klassifiziert. Wenn beide Azetabulumpfeiler bei Hüftprothese betroffen sind, wird auch von einer Beckendiskontinuität gesprochen. Durch eine laterale Kompression können auch periazetabuläre Schambeinastfrakturen und/oder transiliakale Frakturen auftreten. Für die Therapieentscheidung (konservativ, alleinige Osteosynthese, Revisionshüfttotalprothese mit oder ohne zusätzliche Osteosynthese des Vorder- und/oder Hinterpfeilers) und die Zugangswahl bei operativer Versorgung werden patientenspezifische (Alter, Morbidität, Osteoporose, Aktivitätslevel des Patienten), frakturspezifische (Frakturtyp, Dislokationsausmaß, Impression des Doms oder der Hinterwand) und auch prothesenspezifische Faktoren (Art der implantierten Prothese [Hemiprothese vs. Totalprothese], Pfannenstabilität, Zeichen eines Prothesenabriebs, Ausmaß und Lokalisation einer azetabulären Lyse, Stabilität und Lysezeichen des Prothesenschafts) berücksichtigt. Bei akuten Beckendiskontinuitäten werden neben einer Osteosynthese des dorsalen Pfeilers zunehmend eine schnell ossär integrierbare Pfanne (Tantalum [„Trabecular Metal“: TM]) mit oder ohne Augment und/oder Allograft und allenfalls in einer sog. „Cup-Cage“-Technik (TM-Pfanne mit einem abstützenden Revisionsring [Burch-Schneider-Ring] analog zur Therapie von chronischen Beckendiskontinuitäten empfohlen. Bei großen Lysezonen und starken Dislokationen des vorderen Pfeilers und der quadrilateralen Fläche können intrapelvine Zugänge (modifizierter Stoppa- oder Pararectus-Zugang nach Keel) zur zusätzlichen Zuggurtungsosteosynthese des vorderen Pfeilers und Abstützung der quadrilateralen Fläche gewählt werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The instantaneous three-dimensional velocity field past a bioprosthetic heart valve was measured using tomographic particle image velocimetry (PIV). Two digital cameras were used together with a mirror setup to record PIV images from four different angles. Measurements were conducted in a transparent silicone phantom with a simplified geometry of the aortic root. The refraction indices of the silicone phantom and the working fluid were matched to minimize optical distortion from the flow field to the cameras. The silicone phantom of the aorta was integrated in a flow loop driven by a piston pump. Measurements were conducted for steady and pulsatile flow conditions. Results of the instantaneous, ensemble and phase averaged flow field are presented. The three-dimensional velocity field reveals a flow topology, which can be related to features of the aortic valve prosthesis.