Dynamic UCLA for single tilted implant in an aesthetic region


Autoria(s): Goiato, Marcelo Coelho; Sônego, Mariana Vilela; Silva, Emily Vivianne Freitas da; Dekon, Stefan Fiuza de Carvalho; Medeiros, Rodrigo Antonio de; Carvalho, Karina Helga Turcio de; Santos, Daniela Micheline dos
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

07/12/2015

07/12/2015

2015

Resumo

The aim of this paper was to present a rehabilitation of a patient with a dynamic universal castable long abutment (UCLA) for a single tilted implant in the anterior maxillary area. A 57-year-old male patient attended the dentistry college clinic complaining of a vertical fracture of a residual root of the dental element 22. The tooth extraction was indicated for the implant installation. Due to the socket buccal wall thickness, the implant was installed with an inclination to the palate. It was done in a two-stage surgical protocol, and an external hexagon implant (3.75×11.5mm) was placed. After a six-month healing period to correct the implant position, a dynamic UCLA was set in place, rectifying the implant emergence profile at 20°. The ceramic structure fitting was performed and, after the patient's consent, the prosthesis was finalized and installed. After a follow-up period of twenty months, no complications were observed. The installation of tilted implants with a dynamic UCLA may be a viable option, faster and less invasive than bone grafts.

Formato

149-153

Identificador

http://dx.doi.org/10.1016/j.ijscr.2015.01.016

International Journal Of Surgery Case Reports, v. 7C, p. 149-153, 2015.

2210-2612

http://hdl.handle.net/11449/131162

10.1016/j.ijscr.2015.01.016

PMC4336422.pdf

25618842

PMC4336422

Idioma(s)

eng

Publicador

Elsevier B. V.

Relação

International Journal Of Surgery Case Reports

Direitos

openAccess

Palavras-Chave #Dental implant #Esthetics #Mouth rehabilitation
Tipo

info:eu-repo/semantics/article