939 resultados para Muscle-specific Promoters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The precise microenvironment of Paracoccidioides brasiliensis has not yet been discovered perhaps because the methods used are not sensitive enough. We applied to this purpose the polymerase chain reaction (PCR) using three sets of specific primers corresponding to two P. brasiliensis genes. This fungus as well as several other fungi, were grown and their DNA obtained by mechanical disruption and a phenol chloroform isoamylalcohol-based purification method. The DNA served for a PCR reaction that employed specific primers from two P. brasiliensis genes that codify for antigenic proteins, namely, the 27 kDa and the 43 kDa. The lowest detection range for the 27 kDa gene was 3 pg. The amplification for both genes was positive only with DNA from P. brasiliensis; additionally, the mRNA for the 27 kDa gene was present only in P. brasiliensis, as indicated by the Northern analysis. The standardization of PCR technology permitted the amplification of P. brasiliensis DNA in artificially contaminated soils and in tissues of armadillos naturally infected with the fungus. These results indicate that PCR technology could play an important role in the search for P. brasiliensis’ habitat and could also be used in other ecological studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significantly diminished antibody response to hepatitis B vaccine has been demonstrated in adults when the buttock is used as the injection site. However, in Brazil, the buttock continues to be recommended as site of injection for intramuscular administration of vaccines in infants. In this age group, there are no controlled studies evaluating the immunogenicity of the hepatitis B vaccine when administered at this site. In the present study, 258 infants were randomized to receive the hepatitis B vaccine either in the buttock (n = 123) or in the anterolateral thigh muscle (n = 135). The immunization schedule consisted of three doses of hepatitis B vaccine (Engerix Bâ, 10 mug) at 2, 4 and 9 months of age. There were no significant differences in the proportion of seroconversion (99.3% x 99.2%), or in the geometric mean titer of ELISA anti-HBs (1,862.1 x 1,229.0 mIU/mL) between the two groups. This study demonstrates that a satisfactory serological response can be obtained when the hepatitis B vaccine is administered intramuscularly into the buttock.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Out of the twenty-four samples of shrimp and fish muscle used for this study, twelve were collected near a large marine sewer for waste disposal, 3 km off the coast of Fortaleza (Brazil) and used for the isolation of E. coli. Other twelve were collected at the Mucuripe fresh fish market (Fortaleza, Brazil) and used for the isolation of Staphylococcus aureus. Ethanol, water and acetone-diluted extracts of guava and papaya leaf sprouts were tested on the bacteria in order to verify their microbicidal potential. The E. coli strains used in the trials were rated LT positive. The papaya leaf extracts (Carica papaya Linn) showed no microbicidal activity while the guava sprout extracts (Psidium guajava Linn) displayed halos exceeding 13 mm for both species, an effect considered to be inhibitory by the method employed. Guava sprout extracts by 50% diluted ethanol most effectively inhibited E. coli (EPEC), while those in 50% acetone were less effective. It may be concluded that guava sprout extracts constitute a feasible treatment option for diarrhea caused by E. coli or by S. aureus-produced toxins, due to their quick curative action, easy availability in tropical countries and low cost to the consumer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The circumoval precipitin test (COPT), enzyme-linked immunosorbent assay (ELISA) and the immunoblotting anti-adult worm antigen (AWA) and soluble egg antigen (SEA) tests were applied to 17 chronically schistosome-infected patients for the detection of anti-Schistosoma mansoni antibodies before and on four occasions after oxamniquine administration over a period of six months. Compared to a control group, schistosomiasis patients showed high levels of IgG antibodies in AWA and SEA-ELISA. A decrease in IgG levels was observed six months after treatment, although negative reactions were not obtained. Significant decreases in IgG1, IgG3 and, mainly, IgG4, but not anti-SEA IgG2 levels were observed six months after treatment, again without negativity. Analysis of anti-AWA IgG antibodies by immunoblotting before treatment showed a 31 kDa strand in 14 patients (82%) which disappeared in three cases up to six months after treatment; furthermore, anti-SEA IgG antibodies showed the same band in nine patients (53%) before treatment, which disappeared in only four cases up to six months after treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Coronary artery disease and aging seems to be associated with a sedentary lifestyle, contributing to increased abdominal fat and consequently metabolic complications. The exercise can break this cycle by stimulating lipolysis and the use of fatty acids. In Europe there is still a lack of cardiac rehabilitation programmes in hospitals, therefore, this study aims to demonstrate the advantages of implementing home-based exercise programmes, as well as, their effects on cardiovascular prevention. This study analyzed the effects of a home-based exercise programme, in patients with coronary artery disease (myocardial infarction for 1 year), in body composition, abdominal fat, lipid profile. Methods: An ongoing randomized controlled trial with a sample of 20 participants were randomly allocated to intervention (n = 10) and control groups (n = 10). Intervention group performed a specific exercise programme during 8 weeks, consisting of ten home based exercises taking into account flexibility, muscle endurance and strength as well as cardiovascular endurance. Skinfolds thickness were measure to calculate the percentage of total fat: Skinfolds used were suprailiac, abdominal horizontal and vertical. Body mass index calculation and blood tests for lipidic profile were performed. Results: After eight weeks the intervention group decreased significantly the percentage of total fat (p < 0.05), the suprailiac skinfold (p < 0.05), the abdominal horizontal and vertical skinfold (p < 0.05) when compared with control group. In the intervention group it was observed after 8 weeks a significant decrease in body mass index, LDL-cholesterol and triglycerides. Conclusions: Home-based exercise programme influenced body composition, abdominal fat and lipid profile. These results highlight the importance of implementing home based exercises that are easy and cheap to implement in cardiac patients, in order to promote health and reduce cardiovascular risk factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ergonomic interventions such as increased scheduled breaks or job rotation have been proposed to reduce upper limb muscle fatigue in repetitive low-load work. This review was performed to summarize and analyze the studies investigating the effect of job rotation and work-rest schemes, as well as, work pace, cycle time and duty cycle, on upper limb muscle fatigue. The effects of these work organization factors on subjective fatigue or discomfort were also analyzed. This review was based on relevant articles published in PubMed, Scopus and Web of Science. The studies included in this review were performed in humans and assessed muscle fatigue in upper limbs. 14 articles were included in the systematic review. Few studies were performed in a real work environment and the most common methods used to assess muscle fatigue were surface electromyography (EMG). No consistent results were found related to the effects of job rotation on muscle activity and subjective measurements of fatigue. Rest breaks had some positive effects, particularly in perceived discomfort. The increase in work pace reveals a higher muscular load in specific muscles. The duration of experiments and characteristics of participants appear to be the factors that most have influenced the results. Future research should be focused on the improvement of the experimental protocols and instrumentation, in order to the outcomes represent adequately the actual working conditions. Relevance to industry: Introducing more physical workload variation in low-load repetitive work is considered an effective ergonomic intervention against muscle fatigue and musculoskeletal disorders in industry. Results will be useful to identify the need of future research, which will eventually lead to the adoption of best industrial work practices according to the workers capabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A backside protein-surface imprinting process is presented herein as a novel way to generate specific synthetic antibody materials. The template is covalently bonded to a carboxylated-PVC supporting film previously cast on gold, let to interact with charged monomers and surrounded next by another thick polymer. This polymer is then covalently attached to a transducing element and the backside of this structure (supporting film plus template) is removed as a regular “tape”. The new sensing layer is exposed after the full template removal, showing a high density of re-binding positions, as evidenced by SEM. To ensure that the templates have been efficiently removed, this re-binding layer was cleaned further with a proteolytic enzyme and solution washout. The final material was named MAPS, as in the back-side reading of SPAM, because it acts as a back-side imprinting of this recent approach. It was able to generate, for the first time, a specific response to a complex biomolecule from a synthetic material. Non-imprinted materials (NIMs) were also produced as blank and were used as a control of the imprinting process. All chemical modifications were followed by electrochemical techniques. This was done on a supporting film and transducing element of both MAPS and NIM. Only the MAPS-based device responded to oxLDL and the sensing layer was insensitive to other serum proteins, such as myoglobin and haemoglobin. Linear behaviour between log(C, μg mL−1) versus charged tranfer resistance (RCT, Ω) was observed by electrochemical impedance spectroscopy (EIS). Calibrations made in Fetal Calf Serum (FCS) were linear from 2.5 to 12.5 μg mL−1 (RCT = 946.12 × log C + 1590.7) with an R-squared of 0.9966. Overall, these were promising results towards the design of materials acting close to the natural antibodies and applied to practical use of clinical interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A serological survey of Toxoplasma gondii infection in blood donors was carried out in order to identify seroprevalence in Recife, Brazil. Sera from 160 individuals (119 male and 41 female) were evaluated by using a Toxoplasma IgG-antibody enzyme immunoassay (Denka Seiken Co., LTD., Tokyo, Japan). The seropositive percentual for males (79.0%) showed to be higher (p < 0.05) than for females (63.4%). This percentage increases with age, ranging from 18.2% to 92.6% for individuals aging under 20 and 40-50 years old, respectively. For women of childbearing age (18-40 years) it was found a prevalence of 51.6%.