952 resultados para Low cost alternatives


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tetracyclines exhibits activity to a broad range of Gram-negative and Gram-positive bacteria and this fact allied to the low toxicity, low cost, and the advantage of administration by oral route led to their indiscriminate use, which caused the appearance of bacterial resistance to these agents, wich has restricted its clinical utility, though new applications have emerged. On the other hand, the glycylcyclines, semi-synthetic products are similar to tetracyclines, which are active against many bacteria resistant to tetracycline and other classes of antibiotics. The purpose of this paper is to give an overview of this important class of antibiotics focusing on its coordination chemistry and possible applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

TitDrop II, a practice low-cost titrator based on drop counting is proposed. A microcomputer counts drops in an opto-switch and it receives pH values from a commercial pHmeter with RS-232 serial port. The volume of drops must kept constant and the amount of base in each drop is obtained by standardization in the titrator. A linear behavior between height of reservoir of titrant and drop frequency was observed, but there is no influence of low height on drop volume. Acetic acidity in samples of vinager was compared with volumetric titration, and deviation between -2.6 to 3.9% was observed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The oxygen reduction reaction was studied in alkaline media using manganese oxides obtained from spent batteries as electrocatalysts. Three processes were used to recover manganese oxides from spent batteries. The particles obtained were in the range from 8 to 11 nm. The electrochemical experiments indicated a good electrocatalytic activity toward oxygen reduction using the different samples and showing approximately a direct transference of 4 electrons during the process. Even though all the processes were efficient, the best result was observed for the prepared sample using reactants of low cost.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For determination of aliskiren in commercial samples, an analytical UV spectrophotometric method was developed and validate according to ICH guideline. The method was linear in the range between 40 and 100 μg mL-1 (r² = 0.9997, n = 7) and exhibited suitable specificity, accuracy, precision, and robustness. It is simple, it has low cost, and it has low use polluting reagents. Therefore, the proposed method was successfully applied for the assay and dissolution studies of aliskiren in tablet dosage forms, and the results were compared to a validated RP-LC method, showing non-significant difference (P > 0.05).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes a project, construction and test of a low cost air pycnometer, developed to be used preferentially in pharmaceutical research. A complete discussion of the construction, test and calibration of this equipment is presented and some measurements are made using pharmaceutical powders and dry granulations. The equipment performance has been estimated through its calibration curve, and the obtained value to its volume resolution is about 1%. This equipment is accomplished at the Applied Nuclear Physics Laboratory of University of Sorocaba (LAFINAU) in Sorocaba, SP, Brazil and it was denominated "Picnômetro a Ar Uniso - PICNAU".

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An UV-Vis spectrophotometry analytical method for quantifying Efavirenz was developed and validated as an alternative to replace the HPLC current method. The report method presents sample concentration of 10 μg mL-1, dissolved in a solution ethanol:water (60:40, v/v), economic and technically adequate for the purpose adopted. The results and the statistical treated proved that the method being considered an precise and accurate analytical low cost alternative for laboratory routine. The adaptability of this method in product and other analytical methods development has been challenged by mathematical calculation of drug extinction coefficient in water and methanol and practical experiments, showing interesting results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

It is here discussed the development of a low cost analytical instrument with capacity for metals determination using atomic emission measurements in an electrothermal atomization system with a tungsten coil atomizer. The main goal was to show a new frontier for using this atomizer and to demonstrate that the simple instrumental arrangement here proposed has potential for portability and for solving analytical tasks related to metals determination. Atomic emission of calcium was selected for the adjustment of instrumental parameters and to evaluate the main characteristics of the lab-built instrument. Cobalt was determined in medicines and one alloy to demonstrate its feasibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A portable microcontrolled system is proposed to monitor conductivity, temperature and pH in on-line, in situ and remote way from a water reservoir faraway 200 m. The system comprises two modules: one for data reception (located in laboratory) and another for data acquisition/transmission (located near water reservoir). It uses a microcontroller and a transceiver to remote data transmission/reception by radio frequency. Variations of water parameters were simultaneously monitored without interruption during a period of ten hours with a relative error about 4.0 %. The developed system showed simple, stable, accurate, robust and low-cost to determine parameters of water in field.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Infrared spectroscopy is a versatile technique used for qualitative and quantitative determination of all types of molecular species. As far as analysis of confined or flowing gases is concerned, different types of cell can be found in the market, but they are often very expensive. This study describes the construction of a very efficient gas cell with good reproducibility for qualitative infrared analysis of confined or flowing gases, using easily available and low-cost materials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this study Ucides cordatus crab shells were utilized as Fe (II) sorbent as material of low cost and simple preparation. Values of pH of standard solution, biosorbent mass, particles size, contact time (t c) and initial concentration of the standard solution were optimized. The best conditions were pH = 2.00, t c = 840 min and Mc = 0.25 g. The kinetic pseudo first-order model displayed the best description of the adsorption process and the equilibrium study showed that the Langmuir model better describes the adsorption of the Fe (II). There is great affinity between the Fe (II) and the biosorbent.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A rapid and low cost method to determine Cr(VI) in soils based upon alkaline metal extraction at room temperature is proposed as a semi-quantitative procedure to be performed in the field. A color comparison with standards with contents of Cr(VI) in the range of 10 to 150 mg kg-1 was used throughout. For the different types of soils studied, more than 75% of the fortified soluble Cr(VI) were recovered for all levels of spike tested for both the proposed and standard methods. Recoveries of 83 and 99% were obtained for the proposed and the standard methods, respectively, taking into account the analysis of a heavily contaminated soil sample.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work describes methodologies for speciation analysis of the metals copper and zinc as total, total dissolved, labile, as well as complexation capacity (conditional stability constants and available ligand concentration), using the same technique, differential pulse anodic stripping voltammetry (DPASV). Several supporting electrolytes were tested, and the results showed that KNO3 and HNO3 resulted in voltamograms without interferences as well as excellent resolution for the total and labile fractions. The methodology using the DPASV technique allows a simple and low cost analysis of copper and zinc speciation, with high precision and sensitivity, with limits of quantification (LOQ) of 1.8 nmol L-1 for copper and 2.1 nmol L-1 for zinc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A derivative spectrophotometric method was validated for quantification of acyclovir in poly (n-butylcyanoacrylate) (PBCA) nanoparticles. Specificity, linearity, precision, accuracy, recovery, detection (LOD) and quantification (LOQ) limits were established for method validation. First-derivative at 295.2 nm eliminated interferences from nanoparticle ingredients and presented linearity for acyclovir concentrations ranging from 1.25 to 40.0 µg/mL (r = 0.9999). Precision and accuracy data demonstrated good reproducibility. Recovery ranged from 99.3 to 101.2. LOD was 0.08 µg/mL and LOQ, 0.25 µg/mL. Thus, the proposed method proved to be easy, low cost, and accurate, and therefore, an useful alternative to quantify acyclovir in nanoparticles.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This technical note describes the construction of a low-cost optical detector. This device is composed by a high-sensitive linear light sensor (model ILX554) and a microcontroller. The performance of the detector was demonstrated by the detection of emission and Raman spectra of the several atomic systems and the results reproduce those found in the literature.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Significant functions in the Proton Exchange Membrane Fuel Cells (PEMFCs) rely on Gas Diffusion Layers (GDLs), such as control the water balance in the membrane electrode assembly (MEA), allow suitable gas permeability and porosity, etc. Aware of the GDL importance in the cell performance and its great demand in scale-up projects, the fuel cell research group at Instituto de Pesquisas Energéticas e Nucleares (IPEN) has developed a Sieve Printing method (innovative in Brazil) as a strategic solution for producing GDL and electrodes used in high power PEMFC stacks. The method has shown to be adequate to fabricate low cost electrodes, GDLs of different dimensions and to produce any amount of MEAs for power stacks.