946 resultados para Low Molecular Weight Heparin


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nuclear medicine imaging techniques such as PET are of increasing relevance in pharmaceutical research being valuable (pre)clinical tools to non-invasively assess drug performance in vivo. Therapeutic drugs, e.g. chemotherapeutics, often suffer from a poor balance between their efficacy and toxicity. Here, polymer based drug delivery systems can modulate the pharmacokinetics of low Mw therapeutics (prolonging blood circulation time, reducing toxic side effects, increasing target site accumulation) and therefore leading to a more efficient therapy. In this regard, poly-N-(2-hydroxypropyl)-methacrylamide (HPMA) constitutes a promising biocompatible polymer. Towards the further development of these structures, non-invasive PET imaging allows insight into structure-property relationships in vivo. This performant tool can guide design optimization towards more effective drug delivery. Hence, versatile radiolabeling strategies need to be developed and establishing 18F- as well as 131I-labeling of diverse HPMA architectures forms the basis for short- as well as long-term in vivo evaluations. By means of the prosthetic group [18F]FETos, 18F-labeling of distinct HPMA polymer architectures (homopolymers, amphiphilic copolymers as well as block copolymers) was successfully accomplished enabling their systematic evaluation in tumor bearing rats. These investigations revealed pronounced differences depending on individual polymer characteristics (molecular weight, amphiphilicity due to incorporated hydrophobic laurylmethacrylate (LMA) segments, architecture) as well as on the studied tumor model. Polymers showed higher uptake for up to 4 h p.i. into Walker 256 tumors vs. AT1 tumors (correlating to a higher cellular uptake in vitro). Highest tumor concentrations were found for amphiphilic HPMA-ran-LMA copolymers in comparison to homopolymers and block copolymers. Notably, the random LMA copolymer P4* (Mw=55 kDa, 25% LMA) exhibited most promising in vivo behavior such as highest blood retention as well as tumor uptake. Further studies concentrated on the influence of PEGylation (‘stealth effect’) in terms of improving drug delivery properties of defined polymeric micelles. Here, [18F]fluoroethylation of distinct PEGylated block copolymers (0%, 1%, 5%, 7%, 11% of incorporated PEG2kDa) enabled to systematically study the impact of PEG incorporation ratio and respective architecture on the in vivo performance. Most strikingly, higher PEG content caused prolonged blood circulation as well as a linear increase in tumor uptake (Walker 256 carcinoma). Due to the structural diversity of potential polymeric carrier systems, further versatile 18F-labeling strategies are needed. Therefore, a prosthetic 18F-labeling approach based on the Cu(I)-catalyzed click reaction was established for HPMA-based polymers, providing incorporation of fluorine-18 under mild conditions and in high yields. On this basis, a preliminary µPET study of a HPMA-based polymer – radiolabeled via the prosthetic group [18F]F-PEG3-N3 – was successfully accomplished. By revealing early pharmacokinetics, 18F-labeling enables to time-efficiently assess the potential of HPMA polymers for efficient drug delivery. Yet, investigating the long-term fate is essential, especially regarding prolonged circulation properties and passive tumor accumulation (EPR effect). Therefore, radiolabeling of diverse HPMA copolymers with the longer-lived isotope iodine-131 was accomplished enabling in vivo evaluation of copolymer P4* over several days. In this study, tumor retention of 131I-P4* could be demonstrated at least over 48h with concurrent blood clearance thereby confirming promising tumor targeting properties of amphiphilic HPMA copolymer systems based on the EPR effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die Forschung im Bereich der Drug Delivery-Systeme konzentriert sich auf biokompatible und wenig immunogene Trägermoleküle. Eine Klasse vielversprechender Trägersysteme stellen Peptid basierte Polymere dar, die neben einer hohen Biokompatibilität auch eine Sensitivität gegenüber externen Einflüssen aufweisen. Der zwitterionische Charakter von Aminosäuren und Peptiden verhindert die Adsorption von Serumproteinen und ein „antifouling“ Verhalten kann festgestellt werden, sodass diese Moleküle für den Einsatz als Wirkstoffträgersystem sehr geeignet scheinen. In Kombination mit einer bürstenartigen Struktur entstehen Systeme mit einer einzigartigen Peptidarchitektur, die sich durch eine hohe Dichte funktioneller Gruppen für Konjugationsreaktionen auszeichnen und deren formabhängige Zellaufnahme sie besonders attraktiv für die Anwendung als „Nanocarrier“ macht.rnrnDas zwitterionische Poly-(ε-N-Methacryloyl-L-Lysin) (Mw = 721,000 g∙mol 1) wurde durch freie radikalische Polymerisation dargestellt und seine Konformation in Abhängigkeit von Ionenstärke und pH-Wert untersucht. Die Biokompatibilität des Systems konnte durch Toxizitätstests und dynamische Lichtstreuung in humanem Blutserum nachgewiesen werden. Zusammen mit der vernachlässigbaren unspezifischen Aufnahme in dendritische Zellen aus Knochenmark erfüllt das System damit alle Bedingungen, die an ein polymeres Wirkstoffträgersystem gestellt werden. Darüber hinaus können Komplexe des Polymers mit DNA in Gegenwart von divalenten Metallionen für die Gentransfektion verwendet werden.rnrnDurch Kopplung von ε-N-Methacryloyl-L-Lysin mit der Elastin-ähnlichen Polypeptid Pentasequenz Valin-Prolin-Glycin-Glycin-Glycin konnte ein Hexapeptid-Makromonomer dargestellt werden, welches anschließend mittels „grafting through“ Polymerisation zur Polymerbürste umgesetzt wurde. Die wurmartige Struktur der Polymerbürsten wurde in AFM-Aufnahmen gezeigt und eine hohe Kettensteifigkeit der Polymerbürsten über dynamische und statische Lichtstreuung nachgewiesen. Zirkulardichroismus-Messungen lieferten Informationen über struktur-, salz- und temperaturabhängige Veränderungen der Konformation. Toxizitätstests und dynamische Lichtstreuung in humanem Blutserum bestätigten die erwartete Biokompatibilität.rnrnBasierend auf zwei Elastin-ähnlichen Polypeptiden mit ähnlicher Peptidsequenz wurden insgesamt vier unterschiedliche Makromonomere mit jeweils 20 Pentapeptid-Wiederholungseinheiten dargestellt. Über anschließende „grafting through“ Polymerisation entstanden molekulare Bürstenmoleküle mit variierenden externen funktionellen Gruppen, die für zukünftige Konjugationsreaktionen verwendet werden können. Der Einfluss von Ionenstärke und Temperatur auf die Konformation der Makromonomere und Polymere wurde mittels Zirkulardichroismus- und Trübungskurven-Messungen untersucht und ein starker Einfluss der hohen Seitenkettendichte auf das Verhalten der Polymerbürsten wurde festgestellt. Über dynamische Lichtstreuung konnte ein von den externen funktionellen Gruppen abhängiges Aggregationsverhalten in humanem Blutserum nachgewiesen werden.rnrnDie in dieser Arbeit synthetisierten Polymerbürsten mit peptidischen Seitenketten stellen damit biokompatible und vielversprechende Trägersysteme für die Konjugation mit Biomolekülen dar, die zukünftig als Drug Delivery-Systeme ihren Einsatz finden können.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Makromolekulare Wirkstoffträgersysteme sind von starkem Interesse bezüglich der klinischen Anwendung chemotherapeutischer Agenzien. Um ihr klinisches Potential zu untersuchen ist es von besonderer Bedeutung das pharmakokinetische Profil in vivo zu bestimmen. Jede Veränderung der Polymerstruktur beeinflusst die Körperverteilung des entsprechenden Makromoleküls. Aufgrund dessen benötigt man detailliertes Wissen über Struktur-Eigenschaftsbeziehungen im lebenden Organismus, um das Nanocarrier System für zukünftige Anwendungen einzustellen. In dieser Beziehung stellt das präklinische Screening mittels radioaktiver Markierung und Positronen-Emissions-Tomographie eine nützliche Methode für schnelle sowie quantitative Beobachtung von Wirkstoffträgerkandidaten dar. Insbesondere poly(HPMA) und PEG sind im Arbeitsgebiet Polymer-basierter Therapeutika stark verbreitet und von ihnen abgeleitete Strukturen könnten neue Generationen in diesem Forschungsbereich bieten.rnDie vorliegende Arbeit beschreibt die erfolgreiche Synthese verschiedener HPMA und PEG basierter Polymer-Architekturen – Homopolymere, Statistische und Block copolymere – die mittels RAFT und Reaktivesterchemie durchgeführt wurde. Des Weiteren wurden die genannten Polymere mit Fluor-18 und Iod-131 radioaktiv markiert und mit Hilfe von microPET und ex vivo Biodistributionsstudien in tumortragenden Ratten biologisch evaluiert. Die Variation in Polymer-Architektur und darauffolgende Analyse in vivo resultierte in wichtige Schlussfolgerungen. Das hydrophile / lipophile Gleichgewicht hatte einen bedeutenden Einfluss auf das pharmakokinetische Profil, mit besten in vivo Eigenschaften (geringe Aufnahme in Leber und Milz sowie verlängerte Blutzirkulationszeit) für statistische HPMA-LMA copolymere mit steigendem hydrophoben Anteil. Außerdem zeigten Langzeitstudien mit Iod-131 eine verstärkte Retention von hochmolekularen, HPMA basierten statistischen Copolymeren im Tumorgewebe. Diese Beobachtung bestätigte den bekannten EPR-Effekt. Hinzukommend stellen Überstrukturbildung und damit Polymergröße Schlüsselfaktoren für effizientes Tumor-Targeting dar, da Polymerstrukturen über 200 nm in Durchmesser schnell vom MPS erkannt und vom Blutkreislauf eliminiert werden. Aufgrund dessen wurden die hier synthetisierten HPMA Block copolymere mit PEG Seitengruppen chemisch modifiziert, um eine Verminderung in Größe sowie eine Reduktion in Blutausscheidung zu induzieren. Dieser Ansatz führte zu einer erhöhten Tumoranreicherung im Walker 256 Karzinom Modell. Generell wird die Körperverteilung von HPMA und PEG basierten Polymeren stark durch die Polymer-Architektur sowie das Molekulargewicht beeinflusst. Außerdem hängt ihre Effizienz hinsichtlich Tumorbehandlung deutlich von den individuellen Charakteristika des einzelnen Tumors ab. Aufgrund dieser Beobachtungen betont die hier vorgestellte Dissertation die Notwendigkeit einer detaillierten Polymer-Charakterisierung, kombiniert mit präklinischem Screening, um polymere Wirkstoffträgersysteme für individualisierte Patienten-Therapie in der Zukunft maßzuschneidern.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Graphene nanoribbons (GNRs), which are defined as nanometer-wide strips of graphene, are attracting an increasing attention as one on the most promising materials for future nanoelectronics. Unlike zero-bandgap graphene that cannot be switched off in transistors, GNRs possess open bandgaps that critically depend on their width and edge structures. GNRs were predominantly prepared through “top-down” methods such as “cutting” of graphene and “unzipping” of carbon nanotubes, but these methods cannot precisely control the structure of the resulting GNRs. In contrast, “bottom-up” chemical synthetic approach enables fabrication of structurally defined and uniform GNRs from tailor-made polyphenylene precursors. Nevertheless, width and length of the GNRs obtainable by this method were considerably limited. In this study, lateral as well as longitudinal extensions of the GNRs were achieved while preserving the high structural definition, based on the bottom-up solution synthesis. Initially, wider (~2 nm) GNRs were synthesized by using laterally expanded monomers through AA-type Yamamoto polymerization, which proved more efficient than the conventional A2B2-type Suzuki polymerization. The wider GNRs showed broad absorption profile extending to the near-infrared region with a low optical bandgap of 1.12 eV, which indicated a potential of such GNRs for the application in photovoltaic cells. Next, high longitudinal extension of narrow (~1 nm) GNRs over 600 nm was accomplished based on AB-type Diels–Alder polymerization, which provided corresponding polyphenylene precursors with the weight-average molecular weight of larger than 600,000 g/mol. Bulky alkyl chains densely installed on the peripheral positions of these GNRs enhanced their liquid-phase processability, which allowed their formation of highly ordered self-assembled monolayers. Furthermore, non-contact time-resolved terahertz spectroscopy measurements demonstrated high charge-carrier mobility within individual GNRs. Remarkably, lateral extension of the AB-type monomer enabled the fabrication of wider (~2 nm) and long (>100 nm) GNRs through the Diels–Alder polymerization. Such longitudinally extended and structurally well-defined GNRs are expected to allow the fabrication of single-ribbon transistors for the fundamental studies on the electronic properties of the GNRs as well as contribute to the development of future electronic devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die organische Halbleitertechnologie befindet sich seit Jahrzehnten im Focus des Interesses, da sie eine kostengünstige und umweltverträgliche Alternative zu anorganischen Silizium-basierten Halbleitern darstellt. Die Möglichkeit der gezielten Funktionalisierung von definierten Strukturen durch synthetische Methoden, welche eine große Vielfalt an Materialien ermöglicht, steht dabei besonders im Vordergrund. Die Modifikation von physikalischen Eigenschaften ermöglicht dabei eine stark erleichterte Anpassung für den geplanten Anwendungsbereich. Im Rahmen der vorliegenden Dissertation wurden organische Halbleitermaterialien basierend auf Cyclopenta[2,1-b:3,4-b']dithiophen (CDT) dargestellt und hinsichtlich ihrer strukturellen und elektronischen Eigenschaften untersucht. In Kombination mit Benzo[c][1,2,5]thiadiazol (BTZ) und weiteren Akzeptoren wurden zunächst Donor(D)-Akzeptor(A)-Polymere synthetisiert und Struktur-Eigenschaft-Beziehungen aufgestellt. So konnte ein sehr hochmolekulares Polymer CDT-BTZ-Polymer (Mn = 36 kg mol-1, PDI = 2.6) erhalten werden, welches sich durch eine hohe lamellare Ordnung und eine gemessene Ladungsträgermobilität in FETs von über 5.0 cm2V-1s-1 bei Raumtemperatur auszeichnete; bei niedrigen Temperaturen (240 K) war letztgenannte 6.5 cm2V-1s-1. Aufgrund dieses hohen Ladungstransports und der Abwesenheit niedermolekularer Polymerketten innerhalb des Polymers konnte erstmals eine Messung eines HALL-Effektes bewerkstelligt werden. Dies war der erste Beweis eines Band-artigen Ladungstransportes an einem Polymerhalbleiter. Des Weiteren wurde durch synthetische Veränderung der Grundstruktur des Polymers zu längeren Alkylketten eine anisotrope Anordnung der Polymerketten erreicht und die Ladungsträgermobilität (6.5 cm2V-1s-1 bei Raumtemperatur) weiter gesteigert. Darauf aufbauend wurde der Einfluss von stereoisomeren Seitenketten an CDT-BTZ-Polymeren auf Packungsverhalten, Parametern (Sperrstrom, Einschaltstrom) in FETs und Löslichkeit in organischen Lösungsmitteln untersucht. Durch cis-trans-Isomerisierung der Seitenketten wurde hier eine neue Methode zur Optimierung des Packungsverhaltens von Polymeren in dünnen Filmen und Lösung gefunden. Zuletzt wurden D-π-A-Farbstoffen, welche CDT als Verbrückungseinheit (π) beinhalten, dargestellt. Durch Variation von D und A konnten Struktur-Eigenschaft-Beziehungen in der Anwendung in Solarzellen (Feststoffsolarzellen, Flüssigsolarzellen) gefunden werden. Die Untersuchungen der photoinduzierten Absorption und der Photolumisenzenzquantenausbeute lieferten dabei Erklärungen für physikalische Prozesse wie Ladungsinjektion- und rekombination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die vorliegende Arbeit befasst sich mit der Entwicklung eines nichtviralen, effizienten Transfektionsmittels mit einer Kern-Schale-Struktur in der Größenordnung bis 100 nm. Dafür werden magnetische, negativ geladene Eisenoxid-Nanopartikel mittels Thermolyse mit einem Durchmesser von 17 nm synthetisiert und in Wasser überführt. Diese Nanopartikel bilden den Kern des Erbgut-Trägers und werden mittels Layer-by-Layer –Verfahren (LbL) mit geladenen Polymeren, den bioabbaubaren Makromolekülen Poly-L-Lysin und Heparin, beschichtet. Dafür wird zunächst eine geeignete Apparatur aufgebaut. Diese wird zur Herstellung von Kern-Schale-Strukturen mit fünf Polyelektrolytschichten verwendet und liefert Partikel mit einem hydrodynamischen Durchmesser von 58 nm, die bei Abwesenheit von niedermolekularem Salz aggregatfrei sind. Das System wird gegen Salz stabilisiert, indem die letzte Poly-L-Lysin-Schicht mit Polyethylenglycol modifiziert wird. Die so entstandenen Multischalenpartikel zeigen weder im PBS-Puffer noch in humanem Serum Aggregation. Mittels winkelabhängiger dynamischer Lichtstreuung wird die Aggregatbildung kontrolliert, während ζ-Potential-Messungen die Kontrolle der Oberflächenladung erlauben.rnDa siRNA auf Grund ihres negativ geladenen Phosphat-Rückgrats ebenfalls ein Polyelektrolyt ist, wird sie aggregatfrei auf die positiv geladenen PLL-Nanopartikel aufgetragen. Die eingesetzte siRNA ist farbstoffmarkiert, um eine Detektion in vitro zu ermöglichen. Jedoch sind die entstandenen Komplexe mittels Fluoreszenzkorrelations-spektroskopie (FCS) nicht nachweisbar. Auch die Fluoreszenzmarkierung der PEGylierten Außenschale mittels kupferfreier Click-Chemie ist in der FCS nicht sichtbar, sodass eine Fluoreszenzauslöschung der Farbstoffe in den Multischalenpartikeln vermutet wird.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Refinement in microvascular reconstructive techniques over the last 30 years has enabled an increasing number of patients to be rehabilitated for both functional and aesthetic reasons. The purpose of this study was to evaluate different microsurgical practice, including perioperative management, in Germany, Austria, and Switzerland. The DÖSAK collaborative group for Microsurgical Reconstruction developed a detailed questionnaire which was circulated to units in the three countries. The current practice of the departments was evaluated. Thirty-eight questionnaires were completed resulting in a 47.5% response rate. A considerable variation in the number of microsurgical reconstructions per year was noted. In relation to the timing of bony reconstruction, 10 hospitals did reconstructions primarily (26.3%), 19 secondarily (50%) and 9 (23.7%) hospitals used both concepts. In the postoperative course, 15.8% of hospitals use inhibitors of platelet aggregation, most hospitals use low molecular heparin (52.6%) or other heparin products (44.7%). This survey shows variation in the performance, management, and care of microsurgical reconstructions of patients. This is due in part to the microvascular surgeons available in the unit but it is also due to different types of hospitals where various types of care can be performed in these patients needing special perioperative care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are two main types of bone in the human body, trabecular and cortical bone. Cortical bone is primarily found on the outer surface of most bones in the body while trabecular bone is found in vertebrae and at the end of long bones (Ross 2007). Osteoporosis is a condition that compromises the structural integrity of trabecular bone, greatly reducing the ability of the bone to absorb energy from falls. The current method for diagnosing osteoporosis and predicting fracture risk is measurement of bone mineral density. Limitations of this method include dependence on the bone density measurement device and dependence on type of test and measurement location (Rubin 2005). Each year there are approximately 250,000 hip fractures in the United States due to osteoporosis (Kleerekoper 2006). Currently, the most common method for repairing a hip fracture is a hip fixation surgery. During surgery, a temporary guide wire is inserted to guide the permanent screw into place and then removed. It is believed that directly measuring this screw pullout force may result in a better assessment of bone quality than current indirect measurement techniques (T. Bowen 2008-2010, pers. comm.). The objective of this project is to design a device that can measure the force required to extract this guide wire. It is believed that this would give the surgeon a direct, quantitative measurement of bone quality at the site of the fixation. A first generation device was designed by a Bucknell Biomedical Engineering Senior Design team during the 2008- 2009 Academic Year. The first step of this project was to examine the device, conduct a thorough design analysis, and brainstorm new concepts. The concept selected uses a translational screw to extract the guide wire. The device was fabricated and underwent validation testing to ensure that the device was functional and met the required engineering specifications. Two tests were conducted, one to test the functionality of the device by testing if the device gave repeatable results, and the other to test the sensitivity of the device to misalignment. Guide wires were extracted from 3 materials, low density polyethylene, ultra high molecular weight polyethylene, and polypropylene and the force of extraction was measured. During testing, it was discovered that the spring in the device did not have a high enough spring constant to reach the high forces necessary for extracting the wires without excessive deflection of the spring. The test procedure was modified slightly so the wires were not fully threaded into the material. The testing results indicate that there is significant variation in the screw pullout force, up to 30% of the average value. This significant variation was attributed to problems in the testing and data collection, and a revised set of tests was proposed to better evaluate the performance of the device. The fabricated device is a fully-functioning prototype and further refinements and testing of the device may lead to a 3rd generation version capable of measuring the screw pullout force during hip fixation surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis presented here describes methodologies to produce pendant group functionalized polyesters from amido-functionalized α-hydroxy acids. The synthetic methods used to produce the functionalized α-hydroxy acids are compatible with a wide array of functional groups, making this technique highly versatile. The synthesis of functionalized polyesters was investigated to develop polymers with properties that may improve the capabilities of existing biodegradable polyesters for applications in controlled release pharmaceuticals. Chemically modified a-hydroxy acids were synthesized by reacting glyoxylic acid with a primary or secondary amide. To demonstrate the utility of this reaction, fourstructurally dissimilar amide substituents were examined including 2-pyrrolidione, benzamide, acetamide and acrylamide. The reaction is synthetically simple, provides high yields and is uniquely flexible, functionalized monomer. The compatibility of this procedure with the collection of functional groups mentioned circumvents the need for syntheses. The amido-functionalized monomers were polymerized by two different techniques: melt polycondensation and solution polymerization. Melt polycondensation was conducted by heating the monomer past its melting temperature under reduced pressure. Oligomeric functionalized polyesters (= 800 g/mol) with low PDIs (= 1.05) were obtained by melt polycondensation. Melt polycondensation was not compatible with all of the synthesized monomers. Two of the monomers (containing benzamide and acrylamide functionalities) degraded before the polycondensation reaction occurred. Thermal gravimetric analysis confirmed that a process other than polyesterification was occurring, indicating that some amido-functionalized α-hydroxy acids cannot be synthesized in the melt.Solution polymerization was conducted to polymerize functionalized α-hydroxy acids that were incompatible with melt polycondensation. Several modified Steglich polyesterifications were tested including p-toluenesulfonic acid mediated and scandium (III) triflate catalyzed. Only oligomeric functionalized polyesters were formed bythis method. A number of possible side reactions including the formation of an N-acylurea and a cyclic polymer ring were possible. The utility of this procedure appears to be limited due to the complexity of the reaction and its inability to produce high molecular weight polymer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polylactic acid (PLA) is a bio-derived, biodegradable polymer with a number of similar mechanical properties to commodity plastics like polyethylene (PE) and polyethylene terephthalate (PETE). There has recently been a great interest in using PLA to replace these typical petroleum-derived polymers because of the developing trend to use more sustainable materials and technologies. However, PLA¿s inherent slow crystallization behavior is not compatible with prototypical polymer processing techniques such as molding and extrusion, and in turn inhibits its widespread use in industrial applications. In order to make PLA into a commercially-viable material, there is a need to process the material in such a way that its tendency to form crystals is enhanced. The industry standard for producing PLA products is via twin screw extrusion (TSE), where polymer pellets are fed into a heated extruder, mixed at a temperature above its melting temperature, and molded into a desired shape. A relatively novel processing technique called solid-state shear pulverization (SSSP) processes the polymer in the solid state so that nucleation sites can develop and fast crystallization can occur. SSSP has also been found to enhance the mechanical properties of a material, but its powder output form is undesirable in industry. A new process called solid-state/melt extrusion (SSME), developed at Bucknell University, combines the TSE and SSSP processes in one instrument. This technique has proven to produce moldable polymer products with increased mechanical strength. This thesis first investigated the effects of the TSE, SSSP, and SSME polymer processing techniques on PLA. The study seeks to determine the process that yields products with the most enhanced thermal and mechanical properties. For characterization, percent crystallinity, crystallization half time, storage modulus, softening temperature, degradation temperature and molecular weight were analyzed for all samples. Through these characterization techniques, it was observed that SSME-processed PLA had enhanced properties relative to TSE- and SSSP-processed PLA. Because of the previous findings, an optimization study for SSME-processed PLA was conducted where throughput and screw design were varied. The optimization study determined PLA processed with a low flow rate and a moderate screw design in an SSME process produced a polymer product with the largest increase in thermal properties and a high retention of polymer structure relative to TSE-, SSSP-, and all other SSME-processed PLA. It was concluded that the SSSP part of processing scissions polymer chains, creating defects within the material, while the TSE part of processing allows these defects to be mixed thoroughly throughout the sample. The study showed that a proper SSME setup allows for both the increase in nucleation sites within the polymer and sufficient mixing, which in turn leads to the development of a large amount of crystals in a short period of time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Malignant glial brain tumors consistently overexpress neurokinin type 1 receptors. In classic seed-based brachytherapy, one to several rigid (125)I seeds are inserted, mainly for the treatment of small low-grade gliomas. The complex geometry of rapidly proliferating high-grade gliomas requires a diffusible system targeting tumor-associated surface structures to saturate the tumor, including its margins. EXPERIMENTAL DESIGN: We developed a new targeting vector by conjugating the chelator 1,4,7,10-tetraazacyclododecane-1-glutaric acid-4,7,10-triacetic acid to Arg(1) of substance P, generating a radiopharmaceutical with a molecular weight of 1,806 Da and an IC(50) of 0.88 +/- 0.34 nmol/L. Cell biological studies were done with glioblastoma cell lines. neurokinin type-1 receptor (NK1R) autoradiography was done with 58 tumor biopsies. For labeling, (90)Y was mostly used. To reduce the "cross-fire effect" in critically located tumors, (177)Lut and (213)Bi were used instead. In a pilot study, we assessed feasibility, biodistribution, and early and long-term toxicity following i.t. injection of radiolabeled 1,4,7,10-tetraazacyclododecane-1-glutaric acid-4,7,10-triacetic acid substance P in 14 glioblastoma and six glioma patients of WHO grades 2 to 3. RESULTS: Autoradiography disclosed overexpression of NK1R in 55 of 58 gliomas of WHO grades 2 to 4. Internalization of the peptidic vector was found to be specific. Clinically, the radiopharmeutical was distributed according to tumor geometry. Only transient toxicity was seen as symptomatic radiogenic edema in one patient (observation period, 7-66 months). Disease stabilization and/or improved neurologic status was observed in 13 of 20 patients. Secondary resection disclosed widespread radiation necrosis with improved demarcation. CONCLUSIONS: Targeted radiotherapy using diffusible peptidic vectors represents an innovative strategy for local control of malignant gliomas, which will be further assessed as a neoadjuvant approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The biopharmaceutical industry has a growing demand and an increasing need to improve the current virus purification technologies, especially as more and more vaccines are produced from cell-culture derived virus particles. Downstream purification strategies can be expensive and account for 70% of the overall manufacturing costs. The economic pressure and purification processes can be particularly challenging when the virus to be purified is small, as in our model virus, porcine parvovirus (PPV). Our efforts are focused on designing an easy, economical, scalable and efficient system for virus purification, and we focused on aqueous two-phase systems. Industry acceptable standards for virus vaccine recovery can be as low as 30% due to demand of high final titer, virus transduction inhibitors and presence of empty or defective virus capsids as impurities. We have overcome these shortcomings by recovering a high 64% of infectious virus using an aqueous two-phase system. We used high molecular weight polymer and citrate salt to achieve a good yield and eliminated the major contaminant bovine serum albumin. Viruses are also studied for ensuring pure and safe drinking water. Low pressure microfiltrations are continuously being investigated for water filters as they allow high permeate flux and low fouling. Viruses such as PPV are small enough to pass through the microporous membranes. Control of viruses in water is crucial for public health and we have designed an affinity based membrane filter to capture virus. Nanofibers have a high surface to volume ratio providing a highly accessible surface area for virus adsorption. Chitosan an insoluble, biocompatible and biodegradable polymer was used for adsorbing trimer peptide WRW. About 0.2 μmoles of cysteine terminal WRW peptide was conjugated to amine terminal chitosan using maleimide conjugation chemistry. We achieved 90-99% virus removal from water adjusted to a neutral pH. The virus removal from affinity based chitosan was attributed to electrostatic and hydrophobic driven binding effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Preterm birth, low birth weight, and infant catch-up growth seem associated with an increased risk of respiratory diseases in later life, but individual studies showed conflicting results. OBJECTIVES We performed an individual participant data meta-analysis for 147,252 children of 31 birth cohort studies to determine the associations of birth and infant growth characteristics with the risks of preschool wheezing (1-4 years) and school-age asthma (5-10 years). METHODS First, we performed an adjusted 1-stage random-effect meta-analysis to assess the combined associations of gestational age, birth weight, and infant weight gain with childhood asthma. Second, we performed an adjusted 2-stage random-effect meta-analysis to assess the associations of preterm birth (gestational age <37 weeks) and low birth weight (<2500 g) with childhood asthma outcomes. RESULTS Younger gestational age at birth and higher infant weight gain were independently associated with higher risks of preschool wheezing and school-age asthma (P < .05). The inverse associations of birth weight with childhood asthma were explained by gestational age at birth. Compared with term-born children with normal infant weight gain, we observed the highest risks of school-age asthma in children born preterm with high infant weight gain (odds ratio [OR], 4.47; 95% CI, 2.58-7.76). Preterm birth was positively associated with an increased risk of preschool wheezing (pooled odds ratio [pOR], 1.34; 95% CI, 1.25-1.43) and school-age asthma (pOR, 1.40; 95% CI, 1.18-1.67) independent of birth weight. Weaker effect estimates were observed for the associations of low birth weight adjusted for gestational age at birth with preschool wheezing (pOR, 1.10; 95% CI, 1.00-1.21) and school-age asthma (pOR, 1.13; 95% CI, 1.01-1.27). CONCLUSION Younger gestational age at birth and higher infant weight gain were associated with childhood asthma outcomes. The associations of lower birth weight with childhood asthma were largely explained by gestational age at birth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Lead exposure is associated with low birth-weight. The objective of this study is to determine whether lead exposure is associated with lower body weight in children, adolescents and adults. METHODS We analyzed data from NHANES 1999-2006 for participants aged ≥3 using multiple logistic and multivariate linear regression. Using age- and sex-standardized BMI Z-scores, overweight and obese children (ages 3-19) were classified by BMI ≥85 th and ≥95 th percentiles, respectively. The adult population (age ≥20) was classified as overweight and obese with BMI measures of 25-29.9 and ≥30, respectively. Blood lead level (BLL) was categorized by weighted quartiles. RESULTS Multivariate linear regressions revealed a lower BMI Z-score in children and adolescents when the highest lead quartile was compared to the lowest lead quartile (β (SE)=-0.33 (0.07), p<0.001), and a decreased BMI in adults (β (SE)=-2.58 (0.25), p<0.001). Multiple logistic analyses in children and adolescents found a negative association between BLL and the percentage of obese and overweight with BLL in the highest quartile compared to the lowest quartile (OR=0.42, 95% CI: 0.30-0.59; and OR=0.67, 95% CI: 0.52-0.88, respectively). Adults in the highest lead quartile were less likely to be obese (OR=0.42, 95% CI: 0.35-0.50) compared to those in the lowest lead quartile. Further analyses with blood lead as restricted cubic splines, confirmed the dose-relationship between blood lead and body weight outcomes. CONCLUSIONS BLLs are associated with lower body mass index and obesity in children, adolescents and adults.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: There is a continuous debate regarding the best bottle nipple to be used to enhance the bottle-feeding performance of a preterm infant. Aim: To verify that feeding performance can be improved by using the bottle nipple with the physical characteristics that enhance infants' sucking skills. METHODS: Ten "healthy" VLBW infants (941+/-273 g) were recruited. Feeding performance was monitored at two time periods, when taking 1-2 and 6-8 oral feedings/d. At each time and within 24 h, performance was monitored using three different bottle nipples offered in a randomized order. Rate of milk transfer (ml/min) was the primary outcome measure. The sucking skills monitored comprised stage of sucking, suction amplitude, and duration of the generated negative intraoral suction pressure. RESULTS: At both times, infants demonstrated a similar rate of milk transfer among all three nipples. However, the stage of sucking, suction amplitude, and duration of the generated suction were significantly different between nipples at 1-2, but not 6-8 oral feedings/d.CONCLUSION: We did not identify a particular bottle nipple that enhanced bottle feeding in healthy VLBW infants. Based on the notion that afferent sensory feedback may allow infants to adapt to changing conditions, we speculate that infants can modify their sucking skills in order to maintain a rate of milk transfer that is appropriate with the level of suck-swallow-breathe coordination achieved at a particular time. Therefore, it is proposed that caretakers should be more concerned over monitoring the coordination of suck-swallow-breathe than over the selection of bottle nipples.