971 resultados para LASER FLUORESCENCE METHOD


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis investigates metallic nanostructures exhibiting surface plasmon resonance for the amplification of fluorescence signal in sandwich immunoassays. In this approach, an analyte is captured by an antibody immobilized on a plasmonic structure and detected by a subsequently bound fluorophore labeled detection antibody. The highly confined field of surface plasmons originates from collective charge oscillations which are associated with high electromagnetic field enhancements at the metal surface and allow for greatly increased fluorescence signal from the attached fluorophores. This feature allows for improving the signal-to-noise ratio in fluorescence measurements and thus advancing the sensitivity of the sensor platform. In particular, the thesis presents two plasmonic nanostructures that amplify fluorescence signal in devices that rely on epifluorescence geometry, in which the fluorophore absorbs and emits light from the same direction perpendicular to the substrate surface.rnThe first is a crossed relief gold grating that supports propagating surface plasmon polaritons (SPPs) and second, gold nanoparticles embedded in refractive index symmetric environment exhibiting collective localized surface plasmons (cLSPs). Finite-difference time-domain simulations are performed in order to design structures for the optimum amplification of established Cy5 and Alexa Fluor 647 fluorophore labels with the absorption and emission wavelengths in the red region of spectrum. The design takes into account combined effect of surface plasmon-enhanced excitation rate, directional surface plasmon-driven emission and modified quantum yield for characteristic distances in immunoassays. Homebuilt optical instruments are developed for the experimental observation of the surface plasmon mode spectrum, measurements of the angular distribution of surface plasmon-coupled fluorescence light and a setup mimicking commercial fluorescence reading systems in epifluorescence geometry.rnCrossed relief grating structures are prepared by interference lithography and multiple copies are made by UV nanoimprint lithography. The fabricated crossed diffraction gratings were utilized for sandwich immunoassay-based detection of the clinically relevant inflammation marker interleukin 6 (IL-6). The enhancement factor of the crossed grating reached EF=100 when compared to a flat gold substrate. This result is comparable to the highest reported enhancements to date, for fluorophores with relatively high intrinsic quantum yield. The measured enhancement factor excellently agrees with the predictions of the simulations and the mechanisms of the enhancement are explained in detail. Main contributions were the high electric field intensity enhancement (30-fold increase) and the directional fluorescence emission at (4-fold increase) compared to a flat gold substrate.rnCollective localized surface plasmons (cLSPs) hold potential for even stronger fluorescence enhancement of EF=1000, due to higher electric field intensity confinement. cLSPs are established by diffractive coupling of the localized surface plasmon resonance (LSPR) of metallic nanoparticles and result in a narrow resonance. Due to the narrow resonance, it is hard to overlap the cLSPs mode with the absorption and emission bands of the used fluorophore, simultaneously. Therefore, a novel two resonance structure that supports SPP and cLSP modes was proposed. It consists of a 2D array of cylindrical gold nanoparticles above a low refractive index polymer and a silver film. A structure that supports the proposed SPP and cLSP modes was prepared by employing laser interference lithography and the measured mode spectrum was compared to simulation results.rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Das Hydroxyl Radikal ist, auf globalem Maßstab, das bedeutendste Oxidant in der Atmosphäre. Es initiiert den Abbauprozess vieler, teilweise schädlicher, Spurengase und insbesondere den von flüchtigen Kohlenwasserstoffen (VOC). Die OH Konzentration ist somit ein gutes Maß für die augenblickliche Selbstreinigungskapazität der Atmosphäre. Messungen zu nächtlicher Zeit mit LIF-FAGE-Instrumenten (engl.: laser-induced fluorescence - fluorescence assay by gas expansion) haben Konzentrationen des Hydroxylradikals (OH) ergeben, die signifikant höher waren, als sich mit der bekannten Chemie erklären ließ. Um herauszufinden, ob ein solches Signal wirklich atmosphärisches OH ist oder von einer störenden Spezies stammt, die im Messinstrument OH produziert, wurde das LIF-FAGE-Instrument des Max-Planck-Instituts für Chemie (MPIC) im Rahmen dieser Doktorarbeit modifiziert und getestet. Dazu wurde ein so genannter Inlet Pre-Injector (IPI) entwickelt, mit dem in regelmäßigen Abständen ein OH-Fänger in die Umgebungsluft abgegeben werden kann, bevor das OH vom Instrument erfasst wird. Mit dieser Technik ist es möglich, ein Hintergrund-OH (OHbg), d. h. ein im Instrument erzeugtes OH-Signal, vom gemessenen OH-Gesamtsignal (OHtot) zu trennen. Die Differenz zwischen OHtot und OHbg ist die atmosphärische OH-Konzentration (OHatm). Vergleichsmessungen mit der hier entwickelten Technik, dem IPI, in zwei verschiedenen Umgebungen mit Instrumenten basierend auf Massenspektrometrie mit chemischer Ionisation (CIMS, engl.: chemical ionization mass spectrometry) als alternativer Methode des OH-Nachweises, zeigten eine weitgehende Übereinstimmung. Eine umfassende Beschreibung des Systems zur Ermittlung der Ursache des OHbg hat ergeben, dass es weder von einem Artefakt des Instruments noch von hinlänglich bekannten und beschriebenen LIF-FAGE-Interferenzen stammt. Zur Bestimmung der Spezies, die das OHbg-Signal verursacht, wurden verschiedene Laborstudien durchgeführt. Die Arbeit im Rahmen dieser Doktorarbeit hat ergeben, dass das LIF-FAGE-Instrument leicht auf OH reagiert, das beim monomolekularen Zerfall stabilisierter Criegee-Intermediate (SCI) im Niederdruckbereich des Instruments gebildet wird. Criegee-Intermediate oder Carbonyloxide entstehen bei der Ozonolyse ungesättigter flüchtiger Kohlenwasserstoffverbindungen (VOC, engl.: volatile organic compounds) und können daher in der Umgebungsluft vorkommen. Anhand von Tests mit verschiedenen Verweilzeiten der SCI im Niederdruckbereich des Instruments in Verbindung mit einem detaillierten Modell mit der neuesten SCI-Chemie wurde die monomolekulare Zerfallsgeschwindigkeit von 20  10 s-1 für den syn-Acetaldehyd-Oxykonformer bestimmt. Der in Feldkampagnen gemessene OHbg-Wert wurde dahingehend untersucht, ob SCI die Quelle des beobachteten Hintergrund-OH im Feld sein könnten. Das Budget für die SCI-Konzentration, das für die Kampagnen HUMPPA-COPEC 2010 und HOPE 2012 berechnet wurde, ergab eine SCI-Konzentration zwischen ca. 103 und 106 Molekülen pro cm3. In der Kampagne HUMPPA-COPEC 2010 ergab die Schwefelsäurekonzentration, dass die OH-Oxidation von SO2 allein die gemessene H2SO4-Konzentration nicht erklären konnte. In dieser Arbeit konnte gezeigt werden, dass das Hintergrund-OH mit dieser ungeklärten Produktionsrate von H2SO4 korreliert und somit die Oxidation von SO2 durch SCI als mögliche Erklärung in Frage kommt. Ferner korreliert das Hintergrund-OH in der Kampagne HOPE 2012 mit dem Produkt aus Ozon und VOC und konnte mit SO2 als SCI Fänger entfernt werden. Qualitativ zeigen wir somit, dass das in der Umgebungsluft gemessene Hintergrund-OH wahrscheinlich durch den monomolekularen Zerfall von SCI verursacht wird, doch sind weitere Studien notwendig, um die quantitativen Beziehung für diese Spezies und dem Hintergrund-OH in unserem Instrument zu bestimmen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A laser scanning microscope collects information from a thin, focal plane and ignores out of focus information. During the past few years it has become the standard imaging method to characterise cellular morphology and structures in static as well as in living samples. Laser scanning microscopy combined with digital image restoration is an excellent tool for analysing the cellular cytoarchitecture, expression of specific proteins and interactions of various cell types, thus defining valid criteria for the optimisation of cell culture models. We have used this tool to establish and evaluate a three dimensional model of the human epithelial airway wall.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An algorithm for the real-time registration of a retinal video sequence captured with a scanning digital ophthalmoscope (SDO) to a retinal composite image is presented. This method is designed for a computer-assisted retinal laser photocoagulation system to compensate for retinal motion and hence enhance the accuracy, speed, and patient safety of retinal laser treatments. The procedure combines intensity and feature-based registration techniques. For the registration of an individual frame, the translational frame-to-frame motion between preceding and current frame is detected by normalized cross correlation. Next, vessel points on the current video frame are identified and an initial transformation estimate is constructed from the calculated translation vector and the quadratic registration matrix of the previous frame. The vessel points are then iteratively matched to the segmented vessel centerline of the composite image to refine the initial transformation and register the video frame to the composite image. Criteria for image quality and algorithm convergence are introduced, which assess the exclusion of single frames from the registration process and enable a loss of tracking signal if necessary. The algorithm was successfully applied to ten different video sequences recorded from patients. It revealed an average accuracy of 2.47 ± 2.0 pixels (∼23.2 ± 18.8 μm) for 2764 evaluated video frames and demonstrated that it meets the clinical requirements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study is to assess clinical and microbiologic effects of the non-surgical treatment of peri-implantitis lesions using either an erbium-doped:yttrium, aluminum, and garnet (Er:YAG) laser or an air-abrasive subgingival polishing method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The addition of a ZnS shell to CdSe and CdS quantum dot cores was explored using various methods. Spectrophotometry was used to assess the success of ZnS overcoating, which produces both an increase in overall fluorescence and decrease in particle size distribution. A new method was developed, involving preheating of the zinc and sulfide precursor solutions, resulting in CdSe(ZnS) particles with improved fluorescence and a more uniform shell coating from oleylamine-capped CdSe core particles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated (1) the micromorphology by scanning electron microscopy (SEM) and (2) the adhesive performance by microtensile bond strength (μTBS) of diamond bur-treated dentin compared to Er:YAG laser-treated dentin of human primary teeth. (1) For qualitative SEM evaluation, dentin of 18 second primary molars (n = 3/method) was treated with either diamond bur as a control (group 1a: 40 μm diamond bur only (clinical situation); group 1b: grinding + 40 μm diamond bur) or with Er:YAG laser (group 2a (clinical situation, manufacturer's settings): 200 mJ/25 Hz (5 W) + 100 mJ/35 Hz (3.5 W) laser only; group 2b (experimental setting "high"): grinding + 400 mJ/20 Hz (8 W); group 2c (manufacturer's setting "finishing"): grinding + 100 mJ/35 Hz (3.5 W); group 2d (experimental setting "low"): grinding + 50 mJ/35 Hz (1.75 W)). (2) For evaluation of adhesive performance, 64 second primary molars were divided into four groups and treated as described for group 1b and groups 2b/c/d (n = 16/method), and μTBS of Clearfil SE/Clearfil Majesty Esthetic to dentin was measured. The SEM micrographs were qualitatively analyzed. The μTBS values were compared with a Kruskal-Wallis test. The significance level was set at α = 0.05. SEM micrographs showed the typical micromorphologies with a smear layer for the diamond bur groups and open dentin tubules for all laser-treated groups. However, in group 2d, the laser beam had insufficiently irradiated the dentin area, rendering the underlying ground surface partly visible. There were no statistically significant differences between μTBS values of the four groups (p = 0.394). This suggests that Er:YAG laser treatment of dentin of primary molars provides bond strengths similar to those obtained following diamond bur treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Studying liquid fuel combustion is necessary to better design combustion systems. Through more efficient combustors and alternative fuels, it is possible to reduce greenhouse gases and harmful emissions. In particular, coal-derived and Fischer-Tropsch liquid fuels are of interest because, in addition to producing fewer emissions, they have the potential to drastically reduce the United States' dependence on foreign oil. Major academic research institutions like the Pennsylvania State University perform cutting-edge research in many areas of combustion. The Combustion Research Laboratory (CRL) at Bucknell University is striving to develop the necessary equipment to be capable of both independent and collaborative research efforts with Penn State and in the process, advance the CRL to the forefront of combustion studies. The focus of this thesis is to advance the capabilities of the Combustion Research Lab at Bucknell. Specifically, this was accomplished through a revision to a previously designed liquid fuel injector, and through the design and installation of a laser extinction system for the measurement of soot produced during combustion. The previous liquid fuel injector with a 0.005" hole did not behave as expected. Through spray testing the 0.005" injector with water, it was determined that experimental errors were made in the original pressure testing of the injector. Using data from the spray testing experiment, new theoretical hole sizes of the injector were calculated. New injectors with 0.007" and 0.0085" orifices were fabricated and subsequently tested to qualitatively validate their behavior. The injectors were installed in the combustion rig in the CRL and hot-fire tested with liquid heptane. The 0.0085" injector yielded a manageable fuel pressure and produced a broad flame. A laser extinction system was designed and installed in the CRL. This involved the fabrication of a number of custom-designed parts and the specification of laser extinction equipment for purchase. A standard operating procedure for the laser extinction system was developed to provide a consistent, safe method for measuring soot formation during combustion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Definitive diagnosis of the bat disease white-nose syndrome (WNS) requires histologic analysis to identify the cutaneous erosions caused by the fungal pathogen Pseudogymnoascus [formerly Geomyces] destructans (Pd). Gross visual inspection does not distinguish bats with or without WNS, and no nonlethal, on-site, preliminary screening methods are available for WNS in bats. We demonstrate that long-wave ultraviolet (UV) light (wavelength 366-385 nm) elicits a distinct orange yellow fluorescence in bat-wing membranes (skin) that corresponds directly with the fungal cupping erosions in histologic sections of skin that are the current gold standard for diagnosis of WNS. Between March 2009 and April 2012, wing membranes from 168 North American bat carcasses submitted to the US Geological Survey National Wildlife Health Center were examined with the use of both UV light and histology. Comparison of these techniques showed that 98.8% of the bats with foci of orange yellow wing fluorescence (n=80) were WNS-positive based on histologic diagnosis; bat wings that did not fluoresce under UV light (n=88) were all histologically negative for WNS lesions. Punch biopsy samples as small as 3 mm taken from areas of wing with UV fluorescence were effective for identifying lesions diagnostic for WNS by histopathology. In a nonlethal biopsy-based study of 62 bats sampled (4-mm diameter) in hibernacula of the Czech Republic during 2012, 95.5% of fluorescent (n=22) and 100% of nonfluorescent (n=40) wing samples were confirmed by histopathology to be WNS positive and negative, respectively. This evidence supports use of long-wave UV light as a nonlethal and field-applicable method to screen bats for lesions indicative of WNS. Further, UV fluorescence can be used to guide targeted, nonlethal biopsy sampling for follow-up molecular testing, fungal culture analysis, and histologic confirmation of WNS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Reversible ischaemia/reperfusion (I/R) liver injury has been used to induce engraftment and hepatic parenchymal differentiation of exogenous beta2-microglubulin(-)/Thy1(+) bone marrow derived cells. AIM: To test the ability of this method of hepatic parenchymal repopulation, theoretically applicable to clinical practice, to correct the metabolic disorder in a rat model of congenital hyperbilirubinaemia. METHODS AND RESULTS: Analysis by confocal laser microscopy of fluorescence labelled cells and by immunohistochemistry for beta2-microglubulin, 72 hours after intraportal delivery, showed engraftment of infused cells in liver parenchyma of rats with I/R, but not in control animals with non-injured liver. Transplantation of bone marrow derived cells obtained from GFP-transgenic rats into Lewis rats resulted in the presence of up to 20% of GFP positive hepatocytes in I/R liver lobes after one month. The repopulation rate was proportional to the number of transplanted cells. Infusion of GFP negative bone marrow derived cells into GFP positive transgenic rats resulted in the appearance of GFP negative hepatocytes, suggesting that the main mechanism underlying parenchymal repopulation was differentiation rather than cell fusion. Transplantation of wild type bone marrow derived cells into hyperbilirubinaemic Gunn rats with deficient bilirubin conjugation after I/R damage resulted in 30% decrease in serum bilirubin, the appearance of bilirubin conjugates in bile, and the expression of normal UDP-glucuronyltransferase enzyme evaluated by polymerase chain reaction. CONCLUSIONS: I/R injury induced hepatic parenchymal engraftment and differentiation into hepatocyte-like cells of bone marrow derived cells. Transplantation of bone marrow derived cells from non-affected animals resulted in the partial correction of hyperbilirubinaemia in the Gunn rat.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Cerebral revascularization may be indicated either for blood flow preservation or flow augmentation, often in clinical situations where neither endovascular nor standard surgical intervention can be performed. Cerebral revascularization can be performed by using a temporary occlusive or a non-occlusive technique. Both of these possibilities have their specific range of feasibility. Therefore non-occlusive revascularization techniques have been developed. To further reduce the risks for patients, less time consuming, sutureless techniques such as laser tissue soldering are currently being investigated. METHOD: In the present study, a new technique for side-to-side anastomosis was developed. Using a "sandwich technique", two vessels are kept in close contact during the laser soldering. Thoraco-abdominal aortas from 24 different rabbits were analyzed for laser irradiation induced tensile strength. Two different irradiation modes (continuous and pulsed) were used. The results were compared to conventional, noncontact laser soldering. Histology was performed using HE, Mason's Trichrome staining. FINDINGS: The achieved tensile strengths were significantly higher using the close contact "sandwich technique" as compared to the conventional adaptation technique. Furthermore, tensile strength was higher in the continuously irradiated specimen as compared to the specimen undergoing pulsed laser irradiation. The histology showed similar denaturation areas in both groups. The addition of a collagen membrane between vessel components reduced the tensile strength. CONCLUSION: These first results proved the importance of close and tight contact during the laser soldering procedure thus enabling the development of a "sandwich laser irradiation device" for in vivo application in the rabbit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Noise and vibration has long been sought to be reduced in major industries: automotive, aerospace and marine to name a few. Products must be tested and pass certain levels of federally regulated standards before entering the market. Vibration measurements are commonly acquired using accelerometers; however limitations of this method create a need for alternative solutions. Two methods for non-contact vibration measurements are compared: Laser Vibrometry, which directly measures the surface velocity of the aluminum plate, and Nearfield Acoustic Holography (NAH), which measures sound pressure in the nearfield, and using Green’s Functions, reconstructs the surface velocity at the plate. The surface velocity from each method is then used in modal analysis to determine the comparability of frequency, damping and mode shapes. Frequency and mode shapes are also compared to an FEA model. Laser Vibrometry is a proven, direct method for determining surface velocity and subsequently calculating modal analysis results. NAH is an effective method in locating noise sources, especially those that are not well separated spatially. Little work has been done in incorporating NAH into modal analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hall-effect thrusters (HETs) are compact electric propulsion devices with high specific impulse used for a variety of space propulsion applications. HET technology is well developed but the electron properties in the discharge are not completely understood, mainly due to the difficulty involved in performing accurate measurements in the discharge. Measurements of electron temperature and density have been performed using electrostatic probes, but presence of the probes can significantly disrupt thruster operation, and thus alter the electron temperature and density. While fast-probe studies have expanded understanding of HET discharges, a non-invasive method of measuring the electron temperature and density in the plasma is highly desirable. An alternative to electrostatic probes is a non-perturbing laser diagnostic technique that measures Thomson scattering from the plasma. Thomson scattering is the process by which photons are elastically scattered from the free electrons in a plasma. Since the electrons have thermal energy their motion causes a Doppler shift in the scattered photons that is proportional to their velocity. Like electrostatic probes, laser Thomson scattering (LTS) can be used to determine the temperature and density of free electrons in the plasma. Since Thomson scattering measures the electron velocity distribution function directly no assumptions of the plasma conditions are required, allowing accurate measurements in anisotropic and non-Maxwellian plasmas. LTS requires a complicated measurement apparatus, but has the potential to provide accurate, non-perturbing measurements of electron temperature and density in HET discharges. In order to assess the feasibility of LTS diagnostics on HETs non-invasive measurements of electron temperature and density in the near-field plume of a Hall thruster were performed using a custom built laser Thomson scattering diagnostic. Laser measurements were processed using a maximum likelihood estimation method and results were compared to conventional electrostatic double probe measurements performed at the same thruster conditions. Electron temperature was found to range from approximately 1 – 40 eV and density ranged from approximately 1.0 x 1017 m-3 to 1.3 x 1018 m-3 over discharge voltages from 250 to 450 V and mass flow rates of 40 to 80 SCCM using xenon propellant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Discussion of a new, innovative method for dating rocks, called laser ablation split stream (LASS) petrochronology, which is an in situ method that couples geochronological and geochemical data of minerals that remain in the rock matrix. The talk focuses on the application of this technique with U-Th-Pb dating of the phosphate minerals monazite and xenotine in metamorphic rocks. Examples from the Ruby Range in southwestern Montana and metamorphic core complexes in the northern Idaho panhandle will be explored.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several methods to detect anti-A/B antibodies based on haemagglutination and haemolysis have been described. These methods measure predominantly anti-A/B immunoglobulin (Ig)M, whereas anti-A/B IgG and IgG subclasses are less well examined. We established a flow cytometry method (ABO-fluorescence-activated cell sorting; ABO-FACS) to quantify binding of anti-A/B IgM, IgG and IgG subclasses to human A or B red blood cells. Anti-A/B IgM were present in the majority of 120 blood donors, as expected from blood group typing. The sensitivity and specificity of anti-A/B IgM to predict the blood group was 93% and 96% respectively. Anti-A/B IgG was found in 34/38 blood group O samples (89%). Anti-B IgG in blood group A or anti-A IgG in blood group B was present in 4/28 (14%) and 1/28 (4%) samples, respectively, and absent in 26 AB sera. IgG2 was the predominant IgG subclass. The correlation of anti-A/B IgM and IgG in the ABO-FACS with haemagglutination titres was 0.870 and 0.783, respectively (n = 240; P < 0.001) whereas the comparison of ABO-FACS with ABO-enzyme-linked immunosorbent assay was less significant. In conclusion, ABO-FACS is a valid method to quantify anti-A/B IgM, IgG and IgG subclasses. It opens the possibility of isotype-specific monitoring of anti-A/B antibodies levels after ABO-incompatible solid organ and stem cell transplantation.