991 resultados para Insulating silica capillary tubes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new kind of monolithic capillary electrochromatography column with poly(styrene-co-divinylbenzene-co-methacrylic acid) as the stationary phase has been developed. The stationary phase was found to be porous by scanning electron microscopy and the composition of the continuous bed was proved by IR spectroscopy to be the ternary polymer of styrene, divinylbenzene, and methacrylic acid. The effects of operating parameters, such as voltage, electrolyte, and organic modifier concentration in the mobile phase on electroosmotic flow were studied systematically, The retention mechanism of neutral solutes on such a column proved to be similar to that of reversed-phase high performance liquid chromatography. In addition, fast analyses of phenols, chlorobenzenes, anilines, isomeric compounds of phenylenediamine and alkylbenzenes within 4.5 min were achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new set-up was constructed for capillary isoelectric focusing (CIEF) involving a sampling capillary as a bypass fixed to the separation capillary. Sample solutions were subjected to a previously established pH gradient from the sample capillary. Besides performing conventional CIEF, the separation of ampholytic compounds with isoelectric points (p/s) beyond the pH gradient was carried out on this system. This method was termed as pH gradient driven electrophoresis (PGDE) and the basic mathematical expressions were derived to express the dynamic fundamentals. Proteins such as lysozyme, cytochrome C, and pepsin with p/s higher than 10 or below 3 were separated in a pH gradient provided by Pharmalyte (pH 3-10). Finally, this protocol convincingly exhibited its potential in the separation of a solution of chicken egg white.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pressurized capillary electrochromatography (pCEC) and electrospray ionization-mass spectrometry (ESI-MS) have been hyphenated for protein analysis. Taken cytochrome c, lysozyme, and insulin as samples, the limits of detection (LODs) for absolute concentrations are 10(-11) mol (signal-to-noise ratio S/N = 3) with relative standard deviations (RSDs) of retention time and peak area, respectively, of less than 1.7% and 4.8%. In order to improve the detection sensitivity, on-line concentration by field-enhanced sample-stacking effect and chromatographic zone-sharpening effect has been developed, and parameters affecting separation and detection, such as pH and electrolyte concentration in the mobile phase, separation voltage, as well as enrichment voltage and time, have been studied systematically. Under the optimized conditions, the LODs of the three proteins could be decreased up to 100-fold. In addition, the feasibility of such techniques has been further demonstrated by the analysis of modified insulins at a concentration of 20 mu g/mL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An iminodiacetic acid (IDA)-type adsorbent is prepared at the one end of a capillary by covalently bonding IDA to the monolithic rods of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate). Cu(II) is later introduced to the support via the interaction with IDA. By this means, polymer monolithic immobilized metal affinity chromatography (IMAC) materials are prepared. With such a column, IMAC for on-line concentration and capillary electrophoresis (CE) for the subsequent analysis are hyphenated for the analysis of peptides and proteins. The reproducibility of such a column has been proved good with relative standard deviations (RSDs) of dead time of less than 5% for injection-to-injection and 12% for column-to-column (n = 3). Through application on the analysis of standard peptides and real protein samples, such a technique has shown promising in proteome study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interactions between granulocyte-colony stimulating factor (G-CSF) and dextran sulfate/kappa-carrageenan oligosaccharide were studied by capillary zone electrophoresis. Dextran sulfate could strongly interact with G-CSF and the complex was detected. The binding constant and stoichiometry were determined to be 1.2x10(6) (mol/L)(-1) and 3:1, respectively. However, the interaction between K-carrageenan oligosaccharide and G-CSF was not found.