978 resultados para High-energy physics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new gas delivery system is designed and installed for HIRFL-CSR cluster target. The original blocked nozzle is replaced by a new one with the throat diameter of 0.12mm. New test of hydrogen and argon gases are performed. The stable jets can be obtained for these two operation gases. The attenuation of the jet caused by the collision with residual gas is studied. The maximum achievable H-2 target density is 1.75x10(13) atoms/cm(3) with a target thickness of 6.3x10(12) atoms/cm(2) for HIRFL-CSR cluster target. The running stability of the cluster source is tested both for hydrogen and argon. The operation parameters for obtaining hydrogen jet are optimized. The results of long time running for H-2 and Ar cluster jets look promising. The jet intensity has no essential change during the test for H-2 and Ar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The temperature dependences of the light output of CsI(Tl) crystal grown at IMP and of the gain of the Hamamatsu S8664-1010 avalanche photodiode (APD) have been investigated systematically. The light output of the CsI(Tl) crystal increases with temperature by 0.67%/degrees C in the region from -2 degrees C to 8 degrees C, and by 0.33%/degrees C in the region from 8 degrees C to 25 degrees C, while the gain of the tested APD decreases by -3.68%/degrees C (working voltage 400V) on average in the room temperature range. The best energy resolution 5.1% of the CsI(Tl) with APD was obtained for the 662keV gamma ray from Cs-137 radiation source.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Superconducting ECR ion source with Advanced design in Lanzhou (SECRAL) was successfully built to produce intense beams of highly charged ions for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. For 28GHz operation, the magnet assembly can produce peak mirror fields on axis 3.6T at injection, 2.2T at extraction and a radial sextupole field of 2.0T at plasma chamber wall. A unique feature of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. During the ongoing commissioning phase at 18GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.2kW and it turned out the performance is very promising. Some record ion beam intensities have been produced, for instance, 810e mu A of O7+, 505e mu A of Xe20+, 306e mu A of Xe27+, 21e mu A of Xe34+, 2.4e mu A of Xe38+ and so on. To reach better results for highly charged ion beams, further modifications such as an aluminium chamber with better cooling, higher microwave power and a movable extraction system will be done, and also emittance measurements are being prepared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An advanced superconducting ECR ion source named SECRAL has been constructed at Institute of Modern Physics of Chinese Academy of Sciences, whose superconducting magnet assembly consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamp. In order to investigate the structure of sextupole coils and to increase the structural reliabilities of the magnet system, global and local structural analysis have been performed in various operation scenarios. Winding pack and support structure design of magnet system, mechanical calculation and stress analysis are given in this paper. From the analysis results, it has been found that the magnet system is safe in the referential operation scenarios and the configuration of the magnet complies with design requirements of the SECRAL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The high charge state all permanent Electron Cyclotron Resonance Ion Source (ECRIS) LAPECR2 (Lanzhou All Permanent magnet ECR ion source No.2) has been successfully put on the 320kV HV platform at IMP and also has been connected with the successive LEBT system. This source is the largest and heaviest all permanent magnet ECRIS in the world. The maximum mirror field is 1.28T (without iron plug) and the effective plasma chamber volume is as large as circle divide 67mm x 255mm. It was designed to be operated at 14.5GHz and aimed to produce medium charge state and high charge state gaseous and also metallic ion beams. The source has already successfully delivered some intense gaseous ion beams to successive experimental terminals. This paper will give a brief overview of the basic features of this permanent magnet ECRIS. Then commissioning results of this source on the platform, the design of the extraction system together with the successive LEBT system will be presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since 1998, many experiments for metallic ion production have been done on LECR2 (Lanzhou ECR ion source NO.2), LECR3 (Lanzhou ECR ion source NO.3) and SECRAL (Superconductiong ECR ion source Advanced design in Lanzhou) at Institute of Modern Physics. The very heavy metallic ion beams such as those of uranium were also produced by the plasma sputtering method, and supplied for HIRFL (Heavy Ion Research Facility in Lanzhou) accelerators successfully. During the test, 11.5e mu AU(28+), 9e mu AU(24+) were obtained. Some ion beams of the metal having lower melting temperature such as Ni and Mg ion beams were produced by oven method on LECR3 too. The consumption rate was controlled to be lower for Mg-26 ion beams production, and the minimum consumption was about 0.3mg per hour. In this paper, the main experimental results are given. Some discussions are made for some experimental phenomena and results, and some conclusions are drawn.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Lanzhou All Permanent magnet ECR ion source NO. 1 (LAPECR1) is the first all permanent magnet multiple ECRIS made in IMP. This ECRIS is running at 14.5GHz and can provide intense low charge state ion beams (varying from several to hundreds of e mu A) or medium charge state ion beams (varying from several to tens of e mu A). The size of source body is circle divide 102mmx296mm, the compactness and economical features enable the source suitable to be put on a HV platform or equipped by a small laboratory. This article gives the main parameters of the ion source.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Latest developed LECR2M (Lanzhou ECR No. 2 Modified) source is the updated one of LECR2 (Lanzhou ECR No. 2) source at IMP. It has been assembled on the low energy ion beam experimental platform to produce MCI beams for atomic physics and material physics experimental research. In our updating program, the structure of injection and extraction components has been modified to make the source structure more simple and effective. The hexapole magnet has also been replaced by a new hexapole magnet with higher radial field and larger inner diameter. With this updating, stronger magnetic field confinement of the ECR plasma is possible and better base vacuum condition is also achieved. LECR2M was designed to be operated at 14.5GHz. During the preliminary test, 1.3emA O6+ beam was extracted with the injected rf power of 1.1kW. The source has been used to deliver intense MCI beams for different experiments. After some discussion of the main features of this newly updated source, some of the typical commissioning test results of LECR2M will be presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The axial emitted bremsstrahlung spectra were measured on SECRAL (Superconducting ECR ion source with Advanced design in Lanzhou) using an HPGe detector. The spectral temperature T-spe was obtained from the linear fit of the spectra in the semi-log present. The evolution of T-spe with microwave power and magnetic field configuration is investigated in this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A compact proton beam source for space simulation has been developed. A compact structure was designed in order to meet the special requirements of miniaturization. Some particular means have been adopted for improving the proton portion and beam transmission at a long distance. The experimental results showed that 8mA/80keV proton beam can be successfully obtained from this source at about 700W input microwave power.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The high power EUV source is one of key issues in the development of EUV lithography which is considered to be the most promising technology among the next generation lithography. However neither DPP nor LPP seems to meet the requirements of the commercial high-volume product. Insufficiency of DPP and LPP motivate the investigation of other means to produce the EUV radiation required in lithography. ECR plasma seems to be one of the alternatives. In order to investigate the feasibility of ECR plasma as a EUV light source, the EUV power emitted by SECRAL was measured. A EUV power of 1.03W in 4 pi sr solid angle was obtained when 2000W 18GHz rf power was launched, and the corresponding CE was 0.5%. Considering that SECRAL is designed to produce very high charge state ions, this very preliminary result is inspiring. Room-temperature ECR plasma and Sn plasma are both in the planned schedule.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The passive beam delivery system in the superficially-placed tumor therapy terminal at Heavy Ion Researc h Facility in Lanzhou (HIRFL), which includes two orthogonal dipole magnets as scanning system, a motor-driven energy degrader as range-shifter, series of ridge filters as range modulator and a multileaf collimator, is introduced in detail. The capacities of its important components and the whole system have been verified experimentally. The tests of the ridge filter for extending Bragg peak and the range shifter for energy adjustment show both work well. To examine the passive beam delivery system, a beam shaping experiment were carried out, simulating a three-dimensional (3D) conformal irradiation to a tumor. The encouraging experimental result confirms that 3D layer-stacking conformal irradiation can be performed by means of the passive system. The validation of the beam delivery system establishes a substantial basis for upcoming clinical trial for superficially-placed tumors with heavy ions in the therapy terminal at HIRFL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A recoil separator Wien-filter which was developed for the Radioactive Ion Beam Line in Lanzhou (RIBLL) as an extension is described. It consists of 2 quadruple triplets and a standard Wien-filter. It was designed for study of the fusion-evaporation reactions. The overall design, background suppression, the transmission efficiency, the angular acceptance and the momentum acceptance have been described. All the performances fulfil the designed requirements. Based on the test results, with some modifications the investigations of the nuclei with Z <= 110 and the drip-line nuclei in the medium-heavy mass region can be carried out with this facility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The light calibration system is one of the key components of Neutron Wall detector. It is used to calibrate the electronics and to monitor the long-term stability of the detector modules. With the detaile investigations, a calibration system with high-power LED (3W) driven by the fast pulses has been carried out. It is also tested together with the detector module of the Neutron Wall and the result of the preliminary calibration demonstrates that it fulfills the needs. It's a new design proposal to the light calibration system of the fast scintillator detector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reduced velocity correlation functions of the Intermediate Mass Fragments (IMFs) were measured in the reactions of Ar-36+ Sn-112,Sn-124 at 35MeV/u. The anti-correlation at small reduced velocities is more pronounced in Ar-36+ Sn-124 system than that in Ar-36+ Sn-112 system. The difference of the correlation functions between the two reactions is mainly contributed by the particle pairs with high momenta. A three-body Coulomb repulsive trajectory code (MENEKA) is employed to calculate the emission time scale of IMFs for-the both systems. The time scale is 150fm/c in the Ar-36+ Sn-112 system and 120fm/c in the Ar-36+ Sn-124 system, respectively. A calculation based on an Isospin dependence Quantum Molecular Dynamics code (IQMD) reveals that the emission time spectrum of IMFs is shifted slightly leftwards in Ar-36+ Sn-124 compared with that in the Ar-16+ Sn-112 system, indicating a shorter emission time scale. Correspondingly, the central density of the hot nuclei decreases faster in Ar-36+ Sn-124 than in Ar-36+ Sn-112