987 resultados para Heat recovery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Local measurements of the heat transfer coefficient and pressure coefficient were conducted on the tip and near tip region of a generic turbine blade in a five-blade linear cascade. Two tip clearance gaps were used: 1.6% and 2.8% chord. Data was obtained at a Reynolds number of 2.3 × 10 5 based on exit velocity and chord. Three different tip geometries were investigated: a flat (plain) tip, a suction-side squealer, and a cavity squealer. The experiments reveal that the flow through the plain gap is dominated by flow separation at the pressure-side edge and that the highest levels of heat transfer are located where the flow reattaches on the tip surface. High heat transfer is also measured at locations where the tip-leakage vortex has impinged onto the suction surface of the aerofoil. The experiments are supported by flow visualisation computed using the CFX CFD code which has provided insight into the fluid dynamics within the gap. The suction-side and cavity squealers are shown to reduce the heat transfer in the gap but high levels of heat transfer are associated with locations of impingement, identified using the flow visualisation and aerodynamic data. Film cooling is introduced on the plain tip at locations near the pressure-side edge within the separated region and a net heat flux reduction analysis is used to quantify the performance of the successful cooling design. copyright © 2005 by ASME.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large Eddy Simulation (LES) and a novel k -l based hybrid LES/RANS approach have been applied to simulate a conjugate heat transfer problem involving flow over a matrix of surface mounted cubes. In order to assess the capability and reliability of the newly developed k -l based hybrid LES/RANS, numerical results are compared with new LES and existing RANS results. Comparisons include mean velocity profiles, Reynolds stresses and conjugate heat transfer. As well as for hybrid LES/RANS validation purposes, the LES results are used to gain insights into the complex flow physics and heat transfer mechanisms. Numerical simulations show that the hybrid LES/RANS approach is effective. Mean and instantaneous fluid temperatures adjacent to the cube surface are found to strongly correlate with flow structure. Although the LES captures more mean velocity field complexities, broadly time averaged wake temperature fields are found similar for the LES and hybrid LES/RANS. Copyright © 2005 by the American Institute of Aeronautics and Astronautics, Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is an interim report for a study of mussel recovery and species dynamics at four California rocky intertidal sites. Conducted by Kinnetic Laboratories, Inc. (KLI), and funded by the Minerals Management Service (MMS), the initial experimental field study began in spring 1985 and continued through spring 1991. The initial field study included six sites along the central and northern California coast. In 1992, MMS decided to continue the work started by KLI through an in-house study and establishment of the MMS Intertidal (MINT) team. Four of the original six sites have been continued by MMS. The study methods of the original study have been retained by the MINT team, and close coordination with the original KLI team continues. In 1994, the MMS Environmental Studies Program officially awarded a contract to the MINT team for this in-house study. This interim report presents the results from the fall 1992 sampling, the first year of sampling by the MINT team. The report presents a limited statistical analysis and visual comparison of the 1992 data. The next interim report will include data collected during fall 1994 and will present a broader statistical analysis of both the 1992 and 1994 data sets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study heat budget components and momentum flux for August and January 1992 over the north Arabian Sea are computed. The marine meteorological data measured on board during the cruises of PAK-US joint project (NASEER) are used for the computation. Significant differences were found in the heat budget components as well as in the momentum flux during different monsoon periods over the north Arabian Sea. The latent heat flux was always positive and attributed to the large vapour pressure gradient. The computed moisture and latent heat fluxes in January were higher than August The highest value of latent heat flux 309 W/m2 at station 8 was evaluated. These higher latent heat fluxes were due to the large vapour pressure gradient, air-sea temperature difference, the wind speed, and the prevailing wind direction (from north and northeast). Negative values of sensible heat fluxes in both seasons indicate that the heat transfer was from the atmosphere to the ocean. The negative values of net heat gain indicate that the sea surface field became an energy sink: or the sea surface supplied more energy to the atmosphere than it received from it. Large variation in the momentum flux mainly attributed to the variation in the wind speed. Aerial averages of heat and momentum fluxes were also computed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experiment was conducted to optimize the procedure of gynogenesis in African catfish, Clarias gariepinus by suppressing meiotic and mitotic cell divisions in fertilized eggs. Gynogensis was conducted by fertilizing normal eggs with UV-irradiated sperm followed by either heat or cold shocking Irradiation of spermatozoa was given for a duration of 1 min and the eggs were fertilized in vitro. Cold shock at a temperature of 3± 1°C for a duration of 30 and 60 min and heat shock at a temperature of 39± 1°C for a duration of 1 and 2 min was applied to induce diploidy. Higher percentage of hatching (68.66) was observed for meiotic gynogens at a shock temperature of 39± 1°C for a duration of 1 min, 5 min after fertilization (af). Higher percentage of mitotic gynogenetic induction (15.33) was observed at a temperature shock of 39± 1°C for a duration of 1 min, 30 min af.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effect of water depth on recovery rate, growth performance and fish yield of GIFT in the rice-fish production systems was studies in experimental plots of 123 m2 with a pond refuge of I meter deep which covered 10% of the total land area. Mortality rate of fish was very low ranging from 0.81-1.63%. However, at harvest, recovery rate ranged from 76.69-82.93% with the highest recovery at 11-15 em of water depth. Significantly the highest absolute growth (99.97) and specific growth rate (2.42%) were found at 21-25 cm water depth. The same treatment also produced significantly higher fish yield (909.76 kg/ha) although statistically similar to the fish yield (862.60 kg/ha) obtained at ll-15 em of water depth. Results also suggested that higher water depth can produce bigger fish but no significant effects of water depth was found on fish yield in the treatments 11-15 cm and 21-25 cm water depths of this experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper an Active Voltage Control (AVC) technique is presented, for series connection of insulated-gate-bipolar-transistors (IGBT) and control of diode recovery. The AVC technique can control the switching trajectory of an IGBT according to a pre-set reference signal. In series connections, every series connected IGBT follows the reference and so that the dynamic voltage sharing is achieved. Another key advantage for AVC is that by changing the reference signal at turn-on, the diode recovery can be optimised. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 90-day experiment was conducted to determine the effect of restricted ration and full feeding on the recovery growth and carcass compositions of fingerlings (average weight - 20.74 ± 0.13 g) of rohu, Labeo rohita (H.). Rohu fingerlings procured from a local fish breeder were fed with commercial pelleted feed (27% crude protein) during the two-week acclimatization in the laboratory condition. Experimental pelleted diet (30% crude protein) was prepared and the control group (T sub(CFR)) was fed at 3% of body weight for the 90-day trial period. The experimental group T sub(1FR) was fed for three days at 1% of body weight and the next three days at 3% of body weight, T sub(2FR) was fed for seven days at 1% of body weight and the next seven days at 3% of body weight, T sub(3FR) was fed for 15 days at l% of body weight and the 15 days at 3% of body weight and T sub(4FR) was fed for 25 days at 1% of body weight and the next 25 days at 3% of body weight, alternating between 1 and 3% for the specified period during the 90-day trial period. Daily rations were divided into two equal meals per day at 09.00 and 16.00 hours. Average percent survival rate of rohu during the 90-day trial period was more than 90. Percent live weight gain (98.90 ± 0.34, 113.0 ± 5.93, 125.71 ± 11.01 and 141.90 ± 2.89), specific growth rate (1.53 ± 0.01 1.68 ± 0.06, 1.80 ± 0.10 and 1.96 ± 0.02%/d) and absolute growth rate (1.33 ± 0.13, 1.38 ± 0.07, 1.39 ± 0.04 and 1.44 ± 0.07g/d) of the experimental groups (T sub(1FR), T sub(2FR), T sub(3FR) and T sub(4FR) respectively) increased with the advancement of the experiment in comparison to those in control, T sub(CFR) (90.92 ± 5.81%, 1.44 ± 0.07%/d and 1.34 ± 0.20g/d, respectively) and were proportionately correlated with the degree of deprivation probably through the mechanism of increased feed intake (hyperphagia), feed efficiency ratio or gross growth efficiency, protein efficiency ratio and the superior feed conversion ratio reflecting in better performance index. The body length and muscle composition of fish indicated that recovery growth happened due to protein growth but certainly not due to fat deposition in the gut. Feeding at 1 and 3% of body weight alternating over a period of 25 days might economize the culture operation of rohu.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wastage of prawns due to spoilage in processing factories accounted to about 0-12% in 1974, 0-35% in 1975, 0-3% in 1976 and 0-4% in 1977. Spoilage increases with the time lag between catching and processing and also due to defective icing. The paper discusses the counts of whole prawns required for obtaining meat of specified size grades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three enrichment broths and six plating media were compared for efficiency of detection Salmonella in the presence of numbers of Coliforms (10super(5)/ml) and proteus (10super(3)/ml) from artificially inoculated fish samples. Recovery experiments Salmonella anatum, S. typhimurium and S. enteritidis indicated that the two enrichment broths Dulcitol Selinite (DSE) and Selinite Cystine (SC) were equally efficient. Further, the viability of Salmonella, inoculated into fish muscle and kept at 4°C for 48 hours, was found to be not affected by the low temperature storage. Selective plating media like Xylose Lysine Deoxycholate agar (XLD), Brilliant Green Sulphadiazine agar (BGS) and Brilliant Green agar (BG) were found to be superior in performance to Salmonella-Shigella agar: (SS) and Bismuth Sui phite agar (BiS).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An examination was made of the rate of penetration of heat into fish sausage during processing at 115.6°C. Findings showed processing for 24 minutes to bring about complete destruction of Clostridium botulinum. A processing time of 30 minutes destroys almost all spoilage-causing organisms, thus prolonging the shelf life of the products.