929 resultados para CONTROLLER


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the trajectory control of a 2DOF mini electro-hydraulic excavator by using fuzzy self tuning with neural network algorithm. First, the mathematical model is derived for the 2DOF mini electro-hydraulic excavator. The fuzzy PID and fuzzy self tuning with neural network are designed for circle trajectory following. Its two links are driven by an electric motor controlled pump system. The experimental results demonstrated that the proposed controllers have better control performance than the conventional controller.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shapememoryalloy (SMA) actuators, which have the ability to return to a predetermined shape when heated, have many potential applications in aeronautics, surgical tools, robotics and so on. Nonlinearity hysteresis effects existing in SMA actuators present a problem in the motion control of these smart actuators. This paper investigates the control problem of SMA actuators in both simulation and experiment. In the simulation, the numerical Preisachmodel with geometrical interpretation is used for hysteresis modeling of SMA actuators. This model is then incorporated in a closed loop PID control strategy. The optimal values of PID parameters are determined by using geneticalgorithm to minimize the mean squared error between desired output displacement and simulated output. However, the control performance is not good compared with the simulation results when these parameters are applied to the real SMA control since the system is disturbed by unknown factors and changes in the surrounding environment of the system. A further automated readjustment of the PID parameters using fuzzylogic is proposed for compensating the limitation. To demonstrate the effectiveness of the proposed controller, real time control experiment results are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, a linear lightweight electric cylinder constructed using shape memory alloy (SMA) is proposed. Spring SMA is used as the actuator to control the position and force of the cylinder rod. The model predictive control algorithm is investigated to compensate SMA hysteresis phenomenon and control the cylinder. In the predictive algorithm, the future output of the cylinder is computed based on the cylinder model, and the control signal is computed to minimize the error and power criterion. The cylinder model parameters are estimated by an online identification algorithm. Experimental results show that the SMA cylinder is able to precisely control position and force by using the predictive control strategy though the hysteresis effect existing in the actuator. The performance of the proposed controller is compared with that of a conventional PID controller

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This manuscript describes how motor behaviour researchers who are not at the same time expert roboticists may implement an experimental apparatus, which has the ability to dictate torque fields around a single joint on one limb or single joints on multiple limbs without otherwise interfering with the inherent dynamics of those joints. Such an apparatus expands the exploratory potential of the researcher wherever experimental distinction of factors may necessitate independent control of torque fields around multiple limbs, or the shaping of torque fields of a given joint independently of its plane of motion, or its directional phase within that plane. The apparatus utilizes torque motors. The challenge with torque motors is that they impose added inertia on limbs and thus attenuate joint dynamics. We eliminated this attenuation by establishing an accurate mathematical model of the robotic device using the Box-Jenkins method, and cancelling out its dynamics by employing the inverse of the model as a compensating controller. A direct measure of the remnant inertial torque as experienced by the hand during a 50 s period of wrist oscillations that increased gradually in frequency from 1.0 to 3.8 Hz confirmed that the removal of the inertial effect of the motor was effectively complete.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new laboratory-based module for embedded systems teaching, which addresses the current lack of consideration for the link between hardware development, software implementation, course content and student evaluation in a laboratory environment. The course introduces second year undergraduate students to the interface between hardware and software and the programming of embedded devices; in this case, the PIC (originally peripheral interface controller, later rebranded programmable intelligent computer) microcontroller. A hardware development board designed for use in the laboratories of this module is presented. Through hands on laboratory experience, students are encouraged to engage with practical problem-solving exercises and develop programming skills across a broad range of scenarios.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gyps vulture populations across the Indian subcontinent are declining rapidly and evidence indicates that veterinary use of the non-steroidal anti-inflammatory drug (NSAID) diclofenac is the major cause. Exposure of vultures to diclofenac is likely to arise from the consumption of livestock carcasses that have been treated shortly before death, however, detailed information regarding the prevalence and residual levels of diclofenac in carcasses available to vultures in India remains unreported. Here, we present data on diclofenac residues in 1848 liver samples taken from carcasses of dead livestock sampled at 67 sites in 12 states within India, between May 2004 and July 2005. Diclofenac residues were detected in carcasses in all states except Orisa, where only one site was sampled. The overall prevalence of detectable diclofenac (>10 microg kg(-1)) across all states was 10.1% and varied significantly among states, with up to 22.3% prevalence determined in Bihar. The geometric mean concentration of diclofenac found in samples in which the drug was detected was 352 microg kg(-1). The prevalence of carcasses containing diclofenac is similar to that previously proposed to be required to have caused the observed Gyps vulture declines in India. On the 11th of May 2006, the Drug Controller General (India) ordered the withdrawal of all licenses granted for the manufacture of diclofenac for veterinary use within India. However, if Gyps vultures are to be protected, potentially substantial existing stocks now need to be quickly and effectively removed from the Indian veterinary market.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the authors have presented one approach to configuring a Wafer-Scale Integration Chip. The approach described is called the 'WINNER', in which bus channels and an external controller for configuring the working processors are not required. In addition, the technique is applicable to high availability systems constructed using conventional methods. The technique can also be extended to arrays of arbitrary size and with any degree of fault tolerance simply by using an appropriate number of cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Autonomic management can be used to improve the QoS provided by parallel/distributed applications. We discuss behavioural skeletons introduced in earlier work: rather than relying on programmer ability to design “from scratch” efficient autonomic policies, we encapsulate general autonomic controller features into algorithmic skeletons. Then we leave to the programmer the duty of specifying the parameters needed to specialise the skeletons to the needs of the particular application at hand. This results in the programmer having the ability to fast prototype and tune distributed/parallel applications with non-trivial autonomic management capabilities. We discuss how behavioural skeletons have been implemented in the framework of GCM(the Grid ComponentModel developed within the CoreGRID NoE and currently being implemented within the GridCOMP STREP project). We present results evaluating the overhead introduced by autonomic management activities as well as the overall behaviour of the skeletons. We also present results achieved with a long running application subject to autonomic management and dynamically adapting to changing features of the target architecture.
Overall the results demonstrate both the feasibility of implementing autonomic control via behavioural skeletons and the effectiveness of our sample behavioural skeletons in managing the “functional replication” pattern(s).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes an optimisation of the adaptive Gaussian mixture background model that allows the deployment of the method on processors with low memory capacity. The effect of the granularity of the Gaussian mean-value and variance in an integer-based implementation is investigated and novel updating rules of the mixture weights are described. Based on the proposed framework, an implementation for a very low power consumption micro-controller is presented. Results show that the proposed method operates in real time on the micro-controller and has similar performance to the original model. © 2012 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To assess whether open angle glaucoma (OAG) screening meets the UK National Screening Committee criteria, to compare screening strategies with case finding, to estimate test parameters, to model estimates of cost and cost-effectiveness, and to identify areas for future research. Data sources: Major electronic databases were searched up to December 2005. Review methods: Screening strategies were developed by wide consultation. Markov submodels were developed to represent screening strategies. Parameter estimates were determined by systematic reviews of epidemiology, economic evaluations of screening, and effectiveness (test accuracy, screening and treatment). Tailored highly sensitive electronic searches were undertaken. Results: Most potential screening tests reviewed had an estimated specificity of 85% or higher. No test was clearly most accurate, with only a few, heterogeneous studies for each test. No randomised controlled trials (RCTs) of screening were identified. Based on two treatment RCTs, early treatment reduces the risk of progression. Extrapolating from this, and assuming accelerated progression with advancing disease severity, without treatment the mean time to blindness in at least one eye was approximately 23 years, compared to 35 years with treatment. Prevalence would have to be about 3-4% in 40 year olds with a screening interval of 10 years to approach cost-effectiveness. It is predicted that screening might be cost-effective in a 50-year-old cohort at a prevalence of 4% with a 10-year screening interval. General population screening at any age, thus, appears not to be cost-effective. Selective screening of groups with higher prevalence (family history, black ethnicity) might be worthwhile, although this would only cover 6% of the population. Extension to include other at-risk cohorts (e.g. myopia and diabetes) would include 37% of the general population, but the prevalence is then too low for screening to be considered cost-effective. Screening using a test with initial automated classification followed by assessment by a specialised optometrist, for test positives, was more cost-effective than initial specialised optometric assessment. The cost-effectiveness of the screening programme was highly sensitive to the perspective on costs (NHS or societal). In the base-case model, the NHS costs of visual impairment were estimated as £669. If annual societal costs were £8800, then screening might be considered cost-effective for a 40-year-old cohort with 1% OAG prevalence assuming a willingness to pay of £30,000 per quality-adjusted life-year. Of lesser importance were changes to estimates of attendance for sight tests, incidence of OAG, rate of progression and utility values for each stage of OAG severity. Cost-effectiveness was not particularly sensitive to the accuracy of screening tests within the ranges observed. However, a highly specific test is required to reduce large numbers of false-positive referrals. The findings that population screening is unlikely to be cost-effective are based on an economic model whose parameter estimates have considerable uncertainty, in particular, if rate of progression and/or costs of visual impairment are higher than estimated then screening could be cost-effective. Conclusions: While population screening is not cost-effective, the targeted screening of high-risk groups may be. Procedures for identifying those at risk, for quality assuring the programme, as well as adequate service provision for those screened positive would all be needed. Glaucoma detection can be improved by increasing attendance for eye examination, and improving the performance of current testing by either refining practice or adding in a technology-based first assessment, the latter being the more cost-effective option. This has implications for any future organisational changes in community eye-care services. Further research should aim to develop and provide quality data to populate the economic model, by conducting a feasibility study of interventions to improve detection, by obtaining further data on costs of blindness, risk of progression and health outcomes, and by conducting an RCT of interventions to improve the uptake of glaucoma testing. © Queen's Printer and Controller of HMSO 2007. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In future systems with relatively unreliable and unpredictable energy sources such as harvesters, the system power supply may become non-deterministic. For energy effective operations, Vdd is an important parameter in any meaningful system control mechanism. Reliable and accurate on-chip voltage sensors are therefore indispensible for the power and computation management of such systems. Existing voltage sensing methods are not suitable because they usually require a stable and known reference (voltage, current, time, frequency, etc.), which is difficult to obtain in this environment. This paper describes an autonomous reference-free voltage sensor designed using an asynchronous counter powered by the charge on a capacitor and a small controller. Unlike existing methods, the voltage information is directly generated as a digital code. The sensor, fabricated in the 180 nm technology node, was tested successfully through performing measurements over the voltage range from 1.8 V down to 0.8 V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper examines the ability of the doubly fed induction generator (DFIG) to deliver multiple reactive power objectives during variable wind conditions. The reactive power requirement is decomposed based on various control objectives (e.g. power factor control, voltage control, loss minimisation, and flicker mitigation) defined around different time frames (i.e. seconds, minutes, and hourly), and the control reference is generated by aggregating the individual reactive power requirement for each control strategy. A novel coordinated controller is implemented for the rotor-side converter and the grid-side converter considering their capability curves and illustrating that it can effectively utilise the aggregated DFIG reactive power capability for system performance enhancement. The performance of the multi-objective strategy is examined for a range of wind and network conditions, and it is shown that for the majority of the scenarios, more than 92% of the main control objective can be achieved while introducing the integrated flicker control scheme with the main reactive power control scheme. Therefore, optimal control coordination across the different control strategies can maximise the availability of ancillary services from DFIG-based wind farms without additional dynamic reactive power devices being installed in power networks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reactive power has become a vital resource in modern electricity networks due to increased penetration of distributed generation. This paper examines the extended reactive power capability of DFIGs to improve network stability and capability to manage network voltage profile during transient faults and dynamic operating conditions. A coordinated reactive power controller is designed by considering the reactive power capabilities of the rotor-side converter (RSC) and the grid-side converter (GSC) of the DFIG in order to maximise the reactive power support from DFIGs. The study has illustrated that, a significant reactive power contribution can be obtained from partially loaded DFIG wind farms for stability enhancement by using the proposed capability curve based reactive power controller; hence DFIG wind farms can function as vital dynamic reactive power resources for power utilities without commissioning additional dynamic reactive power devices. Several network adaptive droop control schemes are also proposed for network voltage management and their performance has been investigated during variable wind conditions. Furthermore, the influence of reactive power capability on network adaptive droop control strategies has been investigated and it has also been shown that enhanced reactive power capability of DFIGs can substantially improve the voltage control performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The dose delivery accuracy of 30 clinical step and shoot intensity modulated radiation therapy plans was investigated using the single integrated multileaf collimator controller of the Varian Truebeam linear accelerator (linac) (Varian Medical Systems, Palo Alto, CA) and compared with the dose delivery accuracy on a previous generation Varian 2100CD C-Series linac.

Methods and Materials: Ten prostate, 10 prostate and pelvic node, and 10 head-and-neck cases were investigated in this study. Dose delivery accuracy on each linac was assessed using Farmer ionization chamber point dose measurements, 2-dimensional planar ionization chamber array measurements, and the corresponding Varian dynamic log files. Absolute point dose measurements, fluence delivery accuracy, leaf position accuracy, and the overshoot effect were assessed for each plan.

Results: Absolute point dose delivery accuracy increased by 1.5% on the Truebeam compared with the 2100CD linac. No improvement in fluence delivery accuracy between the linacs, at a gamma criterion of 3%/3 mm was measured using the 2-dimensional ionization chamber array, with median (interquartile range) gamma passing rates of 98.99% (97.70%-99.72%) and 99.28% (98.26%-99.75%) for the Truebeam and 2100CD linacs, respectively. Varian log files also showed no improvement in fluence delivery between the linacs at 3%/3 mm, with median gamma passing rates of 99.97% (99.93%-99.99%) and 99.98% (99.94%-100%) for the Truebeam and 2100CD linacs, respectively. However, log files revealed improved leaf position accuracy and fluence delivery at 1%/1 mm criterion on the Truebeam (99.87%; 99.78%-99.94%) compared with the 2100CD linac (97.87%; 91.93%-99.49%). The overshoot effect, characterized on the 2100CD linac, was not observed on the Truebeam.

Conclusions: The integrated multileaf collimator controller on the Varian Truebeam improves clinical treatment delivery accuracy of step and shoot intensity modulated radiation therapy fields compared with delivery on a Varian C-series linac. © 2014.