986 resultados para AIR-FLOW OBSTRUCTION
Resumo:
Because of the scientific evidence showing that arsenic (As), cadmium (Cd), and nickel (Ni) are human genotoxic carcinogens, the European Union (EU) recently set target values for metal concentration in ambient air (As: 6 ng/m3, Cd: 5 ng/m3, Ni: 20 ng/m3). The aim of our study was to determine the concentration levels of these trace elements in Porto Metropolitan Area (PMA) in order to assess whether compliance was occurring with these new EU air quality standards. Fine (PM2.5) and inhalable (PM10) air particles were collected from October 2011 to July 2012 at two different (urban and suburban) locations in PMA. Samples were analyzed for trace elements content by inductively coupled plasma–mass spectrometry (ICP-MS). The study focused on determination of differences in trace elements concentration between the two sites, and between PM2.5 and PM10, in order to gather information regarding emission sources. Except for chromium (Cr), the concentration of all trace elements was higher at the urban site. However, results for As, Cd, Ni, and lead (Pb) were well below the EU limit/target values (As: 1.49 ± 0.71 ng/m3; Cd: 1.67 ± 0.92 ng/m3; Ni: 3.43 ± 3.23 ng/m3; Pb: 17.1 ± 10.1 ng/m3) in the worst-case scenario. Arsenic, Cd, Ni, Pb, antimony (Sb), selenium (Se), vanadium (V), and zinc (Zn) were predominantly associated to PM2.5, indicating that anthropogenic sources such as industry and road traffic are the main source of these elements. High enrichment factors (EF > 100) were obtained for As, Cd, Pb, Sb, Se, and Zn, further confirming their anthropogenic origin.
Resumo:
A pilot study aimed to introduce intraoperative monitoring of liver surgery using transoesophageal echocardiography (TEE) is described. A set of TEE measurements was established as a protocol, consisting of left atrial (LA) dimension at the aortic valve plane; mitral velocity flow integral, calculation of stroke volume and cardiac output (CO); mitral annular plane systolic excursion; finally, right atrial area. A total of 165 measurements (on 21 patients) were performed, 31 occurring during hypotension. The conclusions reached were during acute blood loss LA dimension changed earlier than CVP, and, in one patient, a dynamic left ventricular (LV) obstruction was observed; in 3 patients a transient LV systolic dysfunction was documented. The comparison between 39 CO paired measurements obtained by TEE and PiCCO2 revealed a statistically significant correlation (P < 0.001, r = 0.83). In this pilot study TEE successfully answered the questions raised by the anesthesiologists. Larger cohort studies are needed to address this issue.
Resumo:
We report the case of a 10-year-old girl with two episodes of light-headedness and chest pain during exercise. She had an unremarkable clinical record, physical examination, ECG, and echocardiogram. Noninvasive ischemia tests were positive, but coronary angiography was normal. Exercise stress echocardiogram revealed an exercise-induced intra-left-ventricular obstruction with a peak gradient of 78 mmHg and replicated her symptoms. After starting beta-blocker therapy her clinical status improved and no residual obstruction was detected. The authors review this unsuspected clinical condition, seldom reported in the adult population and, to our knowledge, never before in a child.
Resumo:
Background : The neonatal arterial switch operation (ASO) is now the standard of care for children born with transposition of the great arteries. Stenosis of the neopulmonary artery on long‑term follow up is a known complication. Methods : We performed a retrospective analysis of eleven patients who underwent a cardiac magnetic resonance imaging (MRI) due to echocardiographic evidence suggestive of stenosis of the neopulmonary artery or its branches (mean estimated Doppler gradient 48 mmHg, min 30 mmHg, max 70 mmHg). A comprehensive evaluation of anatomy and perfusion was done by cardiac MRI. Results : The branches of the neopulmonary artery (neo PA) showed decreased caliber in three patients unilaterally and in two patients, bilaterally. Magnetic resonance (MR) perfusion studies showed concomitant decreased flow, with discrepancy between the two lungs of 35/65% or worse, only in the three patients with unilateral obstruction, by two different MR perfusion methods. Conclusions : Cardiac MR can be used as a comprehensive non‑invasive imaging technique to diagnose stenosis of the branches of the neopulmonary after the ASO, allowing evaluation of anatomy and function of the neoPA, its branches, and the differential perfusion to each lung, thus facilitating clinical decision making.
Resumo:
BACKGROUND: Gallstone ileus accounts for 1% to 4% of cases of mechanical bowel obstruction, but may be responsible for up to 25% of cases in older age groups. In non-iatrogenic cases, gallstone migration occurs after formation of a biliary-enteric fistula. In fewer than 10% of patients with gallstone ileus, the impacted gallstones are located in the pylorus or duodenum, resulting in gastric outlet obstruction, known as Bouveret's syndrome. CASE PRESENTATION: We report an 86-year-old female who was admitted to hospital with a 10-day history of persistent vomiting and prostration. She was in hypovolemic shock at the time of arrival in the emergency department. Investigations revealed a gallstone in the duodenal bulb and a cholecystoduodenal fistula. She underwent surgical gastrolithotomy. Unfortunately, she died of aspiration pneumonia on the fourth postoperative day. CONCLUSION: This case shows the importance of considering Bouveret's syndrome in the differential diagnosis of gastric outlet obstruction, especially in the elderly, even in patients with no previous history of gallbladder disease.
Resumo:
Este trabalho realizou-se na empresa Continental – Indústria Têxtil do Ave, S.A (CITA) em colaboração com a empresa Cofely GDF Suez – Energia e Serviços Portugal, S.A. O principal objetivo desta dissertação foi a otimização energética da máquina de impregnar telas para pneus – a máquina ZELL, tendo em conta as principais utilidades envolvidas: eletricidade e gás natural. Deste modo foi feito um levantamento prévio das condições de operação desta máquina relativamente às telas mais representativas da produção da empresa. Tendo-se verificado que as telas em poliéster representam 65% da produção total da máquina ZELL. Para este tipo de produto, foi feita uma análise dos consumos energéticos anuais para avaliar qual das utilidades referidas corresponde à maior parcela energética. Verificou-se que o consumo de gás natural representa a maior parcela da fatura energética anual da empresa correspondendo a 47%. Além disso, da energia total consumida anualmente pela ZELL, que corresponde a 1360 tep, 32% é relativo à energia elétrica e os restantes 68% ao consumo de gás natural. Por fim, procedeu-se à otimização energética estudando as alterações possíveis no sentido de reduzir os consumos energéticos da máquina, sem prejuízo da qualidade do produto final. Para isso propôs-se a instalação de permutadores de fluxo cruzado para pré-aquecer quer o ar fresco quer o ar de combustão. A implementação desta medida tem um período de retorno à volta de três anos e pode levar a uma poupança anual entre 1.359.639 kWh e 2.370.114 kWh para o ar fresco e 393.523 kWh e 639.475 kWh para o ar de combustão.
Resumo:
RESUMO Tratando-se a asma de uma doença respiratória, desde há várias décadas que tem sido abordada a hipótese de que factores ambientais, nomeadamente os relacionados com a qualidade do ar inalado, possam contribuir para o seu agravamento. Para além dos aeroalergenos, outros factores ambientais como a poluição atmosférica estarão associados às doenças respiratórias. O ar respirado contém uma variedade de poluentes atmosféricos, provenientes quer de fontes naturais quer de origem antropogénica, nomeadamente de actividades industriais, domésticas ou das emissões de veículos. Estes poluentes, tradicionalmente considerados como um problema de foro ambiental, têm sido cada vez mais encarados como um problema de saúde pública. Também a qualidade do ar interior, tem sido associada a queixas respiratórias, não só em termos ocupacionais mas também em exposições domésticas. Dentro dos principais poluentes, encontramos a matéria particulada (como as PM10), o O3, NO2, e os compostos orgânicos voláteis (COVs). Se é verdade que os três primeiros têm como principais fontes de exposição a combustão fóssil associada aos veículos automóveis, já os COVs (como o benzeno, tolueno, xileno, etilbenzeno e formaldeído) são poluentes mais característicos do ar interior. Os mecanismos fisiopatológicos subjacentes à agressão dos poluentes do ar não se encontram convenientemente esclarecidos. Pensa-se que após a sua inalação, induzam um grau crescente de stress oxidativo que será responsável pelo desenvolvimento da inflamação das vias aéreas. A progressão do stress oxidativo e da inflamação, associarse- ão posteriormente a lesão local (pulmonar) e sistémica. Neste trabalho pretendeu-se avaliar os efeitos da exposição individual a diversos poluentes, do ar exterior e interior, sobre as vias aéreas, recorrendo a parâmetros funcionais, inflamatórios e do estudo do stress oxidativo. Neste sentido, desenvolveu-se um estudo de painel na cidade de Viseu, em que foram acompanhadas durante 18 meses, 51 crianças com história de sibilância, identificadas pelo questionário do estudo ISAAC. As crianças foram avaliadas em quatro Visitas (quatro medidas repetidas), através de diversos exames, que incluíram execução de espirometria com broncodilatação, medição ambulatória do PEF, medição de FENO e estudo do pH no condensado brônquico do ar exalado. O estudo dos 8-isoprostanos no condensado brônquico foi efectuado somente em duas Visitas, e o do doseamento de malonaldeído urinário somente na última Visita. Para além da avaliação do grau de infestação de ácaros do pó do colchão, para cada criança foi calculado o valor de exposição individual a PM10, O3, NO2, benzeno, tolueno, xileno, etilbenzeno e formaldeído, através de uma complexa metodologia que envolveu técnicas de modelação associadas a medições directas do ar interior (na casa e escola da criança) e do ar exterior. Para a análise de dados foram utilizadas equações de estimação generalizadas com uma matriz de correlação de trabalho uniforme, com excepção do estudo das associações entre poluentes, 8-isoprostanos e malonaldeído. Verificou-se na análise multivariável a existência de uma associação entre o agravamento dos parâmetros espirométricos e a exposição aumentada a PM10, NO2, benzeno, tolueno e etilbenzeno. Foram também encontradas associações entre diminuição do pH do EBC e exposição crescente a PM10, NO2, benzeno e etilbenzeno e associações entre valores aumentados de FENO e exposição a etilbenzeno e tolueno. O benzeno, o tolueno e o etilbenzeno foram associados com maior recurso a broncodilatador nos 6 meses anteriores à Visita e o tolueno com deslocações ao serviço de urgência. Os resultados dos modelos de regressão que incluíram o efeito do poluente ajustado para o grau de infestação de ácaros do pó foram, de uma forma geral, idênticos ao da análise multivariável anterior, com excepção das associações para com o FENO. Nos modelos de exposição com dois poluentes, com o FEV1 como variável resposta, somente o benzeno persistiu com significado estatístico. No modelo com dois poluentes tendo o pH do EBC como variável resposta, somente persistiram as PM10. Os 8-isoprostanos correlacionaram-se com alguns COVs, designadamente etilbenzeno, xileno, tolueno e benzeno. Os valores de malonaldeído urinário não se correlacionaram com os valores de poluentes. Verificou-se no entanto que de uma forma geral, e em particular mais uma vez para os COVs, as crianças mais expostas a poluentes, apresentaram valores superiores de malonaldeído na urina. Verificou-se que os poluentes do ar em geral, e os COVs em particular, se associaram com uma deterioração das vias aéreas. A exposição crescente a poluentes associou-se não só com obstrução brônquica, mas também com FENO aumentado e maior acidez das vias aéreas. A exposição crescente a COVs correlacionou-se com um maior stress oxidativo das vias aéreas (medido pelos 8-isoprostanos). As crianças com exposição superior a COVs apresentaram maiores valores de malonaldeído urinário. Este trabalho sugere uma associação entre exposição a poluentes, inflamação das vias aéreas e stress oxidativo. Vem reforçar o interesse dos poluentes do ar, nomeadamente os associados a ambientes interiores, frequentemente esquecidos e que poderão ser explicativos do agravamento duma criança com sibilância.-----------ABSTRACT: Asthma is a chronic respiratory disease that could be influenced by environmental factors, as allergens and air pollutants. The air breathed contains a diversity of air pollutants, both from natural or anthropogenic sources. Atmospheric pollution, traditionally considered an environmental problem, is nowadays looked as an important public health problem. Indoor air pollutants are also related with respiratory diseases, not only in terms of occupational exposures but also in domestic activities. Particulate matter (such as PM10), O3, NO2 and volatile organic compounds (VOCs) are the main air pollutants. The main source for PM10, O3, NO2 exposure is traffic exhaust while for VOCs (such as benzene, toluene, xylene, ethylbenzene and phormaldehyde) the main sources for exposure are located in indoor environments. The pathophysiologic mechanisms underlying the aggression of air pollutants are not properly understood. It is thought that after inhalation, air pollutants could induce oxidative stress, which would be responsible for airways inflammation. The progression of oxidative stress and airways inflammation, would contribute for the local and systemic effects of the air pollutants. The present study aimed to evaluate the effects of individual exposure to various pollutants over the airways, through lung function tests, inflammatory and oxidative stress biomarkers. In this sense, we developed a panel study in the city of Viseu, that included 51 children with a history of wheezing. Those children that were identified by the ISAAC questionnaire, were followed for 18 months. Children were assessed four times (four repeated measures) through the following tests: spirometry with bronchodilation test, PEF study, FENO evaluation and exhaled breath condensate pH measurement. 8-isoprostane in the exhaled breath condensate were also measured but only in two visits. Urinary malonaldehyde measurement was performed only in the last visit. Besides the assessment of the house dust mite infestation, we calculated for each child the value of individual exposure to a wide range of pollutants: PM10, O3, NO2, benzene, toluene, xylene, ethyl benzene and formaldehyde. This strategy used a complex methodology that included air pollution modelling techniques and direct measurements indoors (homes and schools) and outdoors. Generalized estimating equations with an exchangeable working correlation matrix were used for the analysis of the data. Exceptions were for the study of associations between air pollutants, malonaldehyde and 8-isoprostanes. In the multivariate analysis we found an association between worsening of spirometric outcomes and increased exposure to PM10, NO2, benzene, toluene and ethylbenzene. In the multivariate analysis we found also negative associations between EBC pH and exposure to PM10, NO2, benzene, ethylbenzene and positive associations between FENO and exposure to ethylbenzene and toluene. Benzene, toluene and ethylbenzene were associated with increased use of bronchodilator in the 6 months prior to the visit and toluene with emergency department visits. Results of the regression models that included also the effect of the pollutant adjusted for the degree of infestation to house dust mites, were identical to the previous models. Exceptions were for FENO associations. In the two-pollutant models, with the FEV1 as dependent variable, only benzene persisted with statistical significance. In the two pollutant model with pH of EBC as dependent variable, only PM10 persisted. 8-isoprostanes were well correlated with some VOCs, namely with ethylbenzene, xylene, toluene and benzene. Urinary malonaldehyde did not present any correlation with air pollutants exposure. However, those children more exposed to air pollutants (namely to VOCs), presented higher values of malonaldehyde. It was found that air pollutants in general, and namely VOCs, were associated with deterioration of the airways. The increased exposure to air pollutants was associated not only with airways obstruction, but also with increased FENO and higher acidity of the airways. The increased exposure to VOCs was correlated with increased airways oxidative stress (measured by 8-isoprostane). Children with higher levels of exposure to VOCs had higher values of urinary malonaldehyde. This study suggests a relation between air pollution, airways inflammation and oxidative stress. It suggests also that attention should be dedicated to air quality as air pollutants could cause airways deterioration.
Resumo:
O presente trabalho centrou-se na otimização do rendimento térmico de duas caldeiras aquatubulares da empresa RAR- Refinaria de Açúcar Reunidas, com a finalidade de identificar onde ocorrem perdas de energia e, desta forma, propor soluções para a sua minimização. Para tal, realizaram-se ensaios em duas caldeiras da empresa providas de queimadores mistos, ou seja podem operar com fuelóleo e gás natural, tanto individualmente, como simultaneamente, sendo que para a realização dos ensaios apenas se utilizou o fuelóleo devido ao seu menor custo. Na caldeira designada por 1 realizaram-se ensaios para os caudais de 300, 500, 800, 1000, 1200, 1400 e 1600 kg/h de fuelóleo. A gama de rendimentos térmicos obtida foi entre 88,3 e 91,2%. Na caldeira designada por 3, efetuaram-se ensaios para os caudais de fuelóleo de 300, 500, 700, 900, 1000, 1200, 1400, 1500 e 1800 kg/h e os rendimentos térmicos obtidos foram entre 85,2 e 88,0%. Em ambas as caldeiras e para caudais baixos verificou-se que a quantidade de ar introduzida no processo de combustão era superior à necessária, conduzindo a uma diminuição dos valores de rendimento térmico. Para 500 kg/h de fuelóleo, por exemplo, a quantidade de ar utilizada foi cerca de duas vezes superiores ao valor estequiométrico. Tendo em conta estes factos, foi proposto ao gestor de energia a implementação de uma nova relação de ar/combustível vs caudal de combustível no sistema de controlo das referidas caldeiras. Após alguns testes (excluindo 300 kg/h de fuelóleo devido a questões de operação), considerou-se como caudal mínimo de operação os 500 Kg/h de fuelóleo nas respetivas caldeiras 1 e 3. Verificou-se que os rendimentos térmicos aumentaram, no caso da caldeira 1, para valores entre os 90,1 e 91,3% e, na caldeira 3, para valores entre 89,0 e 90,9%. Por fim, efetuou-se uma breve análise económica com o intuito de se avaliar e quantificar o que a empresa pode poupar com esta medida. O lucro anual pode oscilar entre 14.400 e 62.640€ ou 104.400 e 136.800€, para as caldeiras 1 e 3, respetivamente.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Informática
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente, perfil Engenharia Sanitária
Resumo:
SUMMARYAIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and symptomatic phases of cryptococcosis are key components to reduce mortality. Recently, the cryptococcal antigen lateral flow assay (CrAg LFA) was included in the armamentarium for diagnosis. Unlike the other tests, the CrAg LFA is a dipstick immunochromatographic assay, in a format similar to the home pregnancy test, and requires little or no lab infrastructure. This test meets all of the World Health Organization ASSURED criteria (Affordable, Sensitive, Specific, User friendly, Rapid/robust, Equipment-free, and Delivered). CrAg LFA in serum, plasma, whole blood, or cerebrospinal fluid is useful for the diagnosis of disease caused by Cryptococcusspecies. The CrAg LFA has better analytical sensitivity for C. gattii than CrAg-latex or EIA. Prevention of cryptococcal disease is new application of CrAg LFA via screening of blood for subclinical infection in asymptomatic HIV-infected persons with CD4 counts < 100 cells/mL who are not receiving effective antiretroviral therapy. CrAg screening of leftover plasma specimens after CD4 testing can identify persons with asymptomatic infection who urgently require pre-emptive fluconazole, who will otherwise progress to symptomatic infection and/or die.
Resumo:
Modelling of ventilation is strongly dependent on the physical characteristics of the building of which precise evaluation is a complex and time consuming task. In the frame of a research project, two children day care centres (CDCC) have been selected in order to measure the envelope air permeability, the flow rate of mechanical ventilation systems and indoor and outdoor temperature. The data obtained was used as input to the computer code CONTAM for ventilation simulations. The results obtained were compared with direct measurements of ventilation flow from short term measurements with CO2 tracer gas and medium term measurements with perfluorocarbon tracer (PFT) gas decay method. After validation, in order to analyse the main parameters that affect ventilation, the model was used to predict the ventilation rates for a wide range of conditions. The purpose of this assessment was to find the best practices to improve natural ventilation. A simple analytical method to predict the ventilation flow rate of rooms is also presented. The method is based on the estimation of wind effect on the room through the evaluation of an average factor and on the assessment of relevant cross section of gaps and openings combined in series or in parallel. It is shown that it may be applied with acceptable accuracy for this type of buildings when ventilation is due essentially to wind action.
Resumo:
The ex utero intrapartum treatment is a rare surgical procedure performed in cases of expected postpartum fetal airway obstruction. The technique lies on a safe establishment of a patent airway during labor in anticipation of a critical respiratory event, without interrupting maternal-fetal circulation. Anesthetic management is substantially different from that regarding standard cesarean delivery and its main goals include uterine relaxation, fetal anesthesia and preservation of placental blood flow. We present the case of an ex utero intrapartum treatment procedure performed on a fetus with a large cervical lymphangioma and prenatal evidence of airway compromise. Modifications to the classic ex utero intrapartum treatment management strategies were successfully adopted and will be discussed in the following report.
Resumo:
Morbid obesity is an epidemic and complex disease which imposes a multidisciplinary approach. Laparoscopic sleeve gastrectomy has become a frequent procedure given its effi- cacy and safety compared to other surgical options. However, it isn’t free from complications. Lax gastric fixation or incorrect positioning of the stomach during surgery can result in early gastric outlet obstruction caused by a volvulus-like mechanism by rotation of the stomach around its anatomic axes. This report refers to two cases of post sleeve gastric torsion resulting in persisting vomiting after initiating oral intake. The diagnosis was confirmed by upper gastrointestinal-contrast study and gastroscopy. In both cases, a fully covered self-expandable metallic stentwas insertedwhich prompted the gastric lumen to become permeable resulting in symptomatic resolution. The stents were removed endoscopically aftertwo and three months. Beyond more than three years offollow-up,the patients remain asymptomatic and no recurring ‘‘stenosis’’ was noticed.In these cases the use offully covered self-expandable metallic stents demonstrated to be effective and safe in the treatment of post sleeve gastric torsion.