998 resultados para normal operational mode
Resumo:
Background: TIDratio indirectly reflects myocardial ischemia and is correlated with cardiacprognosis. We aimed at comparing the influence of three different softwarepackages for the assessment of TID using Rb-82 cardiac PET/CT. Methods: Intotal, data of 30 patients were used based on normal myocardial perfusion(SSS<3 and SRS<3) and stress myocardial blood flow 2mL/min/g)assessed by Rb-82 cardiac PET/CT. After reconstruction using 2D OSEM (2Iterations, 28 subsets), 3-D filtering (Butterworth, order=10, ωc=0.5), data were automatically processed, and then manually processed fordefining identical basal and apical limits on both stress and rest images.TIDratio were determined with Myometrix®, ECToolbox® and QGS®software packages. Comparisons used ANOVA, Student t-tests and Lin concordancetest (ρc). Results: All of the 90 processings were successfullyperformed. TID ratio were not statistically different between software packageswhen data were processed automatically (P=0.2) or manually (P=0.17). There was a slight, butsignificant relative overestimation of TID with automatic processing incomparison to manual processing using ECToolbox® (1.07 ± 0.13 vs 1.0± 0.13, P=0.001)and Myometrix® (1.07 ± 0.15 vs 1.01 ± 0.11, P=0.003) but not using QGS®(1.02 ±0.12 vs 1.05 ± 0.11, P=0.16). The best concordance was achieved between ECToolbox®and Myometrix® manual (ρc=0.67) processing.Conclusion: Using automatic or manual mode TID estimation was not significantlyinfluenced by software type. Using Myometrix® or ECToolbox®TID was significantly different between automatic and manual processing, butnot using QGS®. Software package should be account for when definingTID normal reference limits, as well as when used in multicenter studies. QGS®software seemed to be the most operator-independent software package, whileECToolbox® and Myometrix® produced the closest results.
Resumo:
Exact formulas for the effective eigenvalue characterizing the initial decay of intensity correlation functions are given in terms of stationary moments of the intensity. Spontaneous emission noise and nonwhite pump noise are considered. Our results are discussed in connection with earlier calculations, simulations, and experimental results for single-mode dye lasers, two-mode inhomogeneously broadened lasers, and two-mode dye ring lasers. The effective eigenvalue is seen to depend sensitively on noise characteristics and symmetry properties of the system. In particular, the effective eigenvalue associated with cross correlations of two-mode lasers is seen to vanish in the absence of pump noise as a consequence of detailed balance. In the presence of pump noise, the vanishing of this eigenvalue requires equal pump parameters for the two modes and statistical independence of spontaneous emission noise acting on each mode.
Resumo:
The quantum-kinetic energy of a finite number of trapped fermionic atoms provides a restoring force for shear motion due to a distortion of the momentum distribution. In analogy to the twist mode of nuclear physics, it is proposed that counter rotating the upper and lower hemisphere of a spherical atomic cloud yields a finite-frequency mode closely related to transverse zero sound waves in bulk Fermi liquids.
Resumo:
The turn-on process of a multimode VCSEL is investigated from a statistical point of view. Special attention is paid to quantities such as time jitter and bit error rate. The single-mode performance of VCSEL¿s during current modulation is compared to that of edge-emitting lasers.
Resumo:
PURPOSE: To develop a breathhold method for black-blood viability imaging of the heart that may facilitate identifying the endocardial border. MATERIALS AND METHODS: Three stimulated-echo acquisition mode (STEAM) images were obtained almost simultaneously during the same acquisition using three different demodulation values. Two of the three images were used to construct a black-blood image of the heart. The third image was a T(1)-weighted viability image that enabled detection of hyperintense infarcted myocardium after contrast agent administration. The three STEAM images were combined into one composite black-blood viability image of the heart. The composite STEAM images were compared to conventional inversion-recovery (IR) delayed hyperenhanced (DHE) images in nine human subjects studied on a 3T MRI scanner. RESULTS: STEAM images showed black-blood characteristics and a significant improvement in the blood-infarct signal-difference to noise ratio (SDNR) when compared to the IR-DHE images (34 +/- 4.1 vs. 10 +/- 2.9, mean +/- standard deviation (SD), P < 0.002). There was sufficient myocardium-infarct SDNR in the STEAM images to accurately delineate infarcted regions. The extracted infarcts demonstrated good agreement with the IR-DHE images. CONCLUSION: The STEAM black-blood property allows for better delineation of the blood-infarct border, which would enhance the fast and accurate measurement of infarct size.
Resumo:
The complexity of sleep-wake regulation, in addition to the many environmental influences, includes genetic predisposing factors, which begin to be discovered. Most of the current progress in the study of sleep genetics comes from animal models (dogs, mice, and drosophila). Multiple approaches using both animal models and different genetic techniques are needed to follow the segregation and ultimately to identify 'sleep genes' and molecular bases of sleep disorders. Recent progress in molecular genetics and the development of detailed human genome map have already led to the identification of genetic factors in several complex disorders. Only a few genes are known for which a mutation causes a sleep disorder. However, single gene disorders are rare and most common disorders are complex in terms of their genetic susceptibility, environmental factors, gene-gene, and gene-environment interactions. We review here the current progress in the genetics of normal and pathological sleep and suggest a few future perspectives.
Resumo:
MoS(x) lubricating thin films were deposited by nonreactive, reactive, and low energy ion-assisted radio-frequency (rf) magnetron sputtering from a MoS2 target. Depending on the total and reactive gas pressures, the film composition ranges between MoS0.7 and MoS2.8. A low working pressure was found to have effects similar to those of low-energy ion irradiation. Films deposited at high pressure have (002) planes preferentially perpendicular to the substrate, whereas films deposited at low pressure or under low-energy ion irradiation have (002) mainly parallel to it. Parallel films are sulfur deficient (MoS1.2-1.4). Their growth is explained in terms of an increased reactivity of the basal surfaces, itself a consequence of the creation of surface defects due to ion irradiation. The films exhibit a lubricating character for all compositions above MoS1.2. The longest lifetime in ball-on-disk wear test was found for MoS1.5.
Resumo:
OBJECTIVE: The purpose of this study was to evaluate the effect of structured physical exercise programs during pregnancy on the course of labor and delivery. STUDY DESIGN: We conducted a systematic review and metaanalysis using the following data sources: Medline and The Cochrane Library. In our study, we used randomized controlled trials (RCT) that evaluated the effects of exercise programs during pregnancy on labor and delivery. The results are summarized as relative risks. RESULTS: In the 16 RCTs that were included there were 3359 women. Women in exercise groups had a significantly lower risk of cesarean delivery (relative risk, 0.85; 95% confidence interval [CI], 0.73-0.99). Birthweight was not significantly reduced in exercise groups. The risk of instrumental delivery was similar among groups (relative risk, 1.00; 95% CI, 0.82-1.22). Data on Apgar score, episiotomy, epidural anesthesia, perineal tear, length of labor, and induction of labor were insufficient to draw conclusions. With the use of data from 11 studies (1668 women), our analysis showed that women in the exercise groups gained significantly less weight than women in control groups (mean difference, -1.13 kg; 95% CI, -1.49 to -0.78). CONCLUSION: Structured physical exercise during pregnancy reduces the risk of cesarean delivery. This is an important finding to convince women to be active during their pregnancy and should lead the physician to recommend physical exercise to pregnant women, when this is not contraindicated.
Resumo:
A utilização de métodos de diagnose nutricional para definição de teores ótimos e níveis críticos de nutrientes em tecidos vegetais tem se demonstrado promissora, desde que se conheçam suas limitações. Este trabalho teve como objetivo determinar as faixas normais de nutrientes para a cultura da laranjeira-pera em uma população, utilizando os métodos Chance Matemática (ChM), Sistema Integrado de Diagnose e Recomendação (DRIS) e Diagnose da Composição Nutricional (CND), além do Nível Crítico, pelo método de distribuição normal reduzida. O trabalho foi realizado no município de Bebedouro-SP, na Estação Experimental de Citricultura de Bebedouro. Utilizaram-se como base de dados teores totais de nutrientes de 50 amostras foliares e a produtividade da laranjeira-pera, oriundas de um experimento cujo fator de avaliação foram doses de calcário aplicadas superficialmente. Para o N, maior valor de ChM foi obtido pela classe 2 (23,6 a 24,7 g kg-1), com valores semelhantes aos obtidos pelo DRIS (22,1 a 24,0 g kg-1) e CND (22,1 a 23,9 g kg-1). Os valores inferiores dessas faixas normais concordam com o do nível crítico alcançado (22,7 g kg-1), sendo este muito próximo do proposto pela literatura. Para os nutrientes P, K, Mg, Zn e B, as faixas normais e os níveis críticos não se assemelharam aos descritos na literatura. Em relação aos nutrientes Ca, Fe, Mn e Cu, seus valores de faixa normal e nível crítico aproximaram-se dos recomendados, possivelmente devido à maior variação em seus teores. A utilização dos métodos propostos, em uma população, foi mais adequada quando houve maior variação nos teores dos nutrientes, além de possibilitar menor amplitude aos valores de faixas normais, quando comparados aos da faixa de terras suficientes encontrados na literatura.
Resumo:
We present a numerical study of classical particles diffusing on a solid surface. The particles motion is modeled by an underdamped Langevin equation with ordinary thermal noise. The particle-surface interaction is described by a periodic or a random two-dimensional potential. The model leads to a rich variety of different transport regimes, some of which correspond to anomalous diffusion such as has recently been observed in experiments and Monte Carlo simulations. We show that this anomalous behavior is controlled by the friction coefficient and stress that it emerges naturally in a system described by ordinary canonical Maxwell-Boltzmann statistics.
Resumo:
The research reported in this series of article aimed at (1) automating the search of questioned ink specimens in ink reference collections and (2) at evaluating the strength of ink evidence in a transparent and balanced manner. These aims require that ink samples are analysed in an accurate and reproducible way and that they are compared in an objective and automated way. This latter requirement is due to the large number of comparisons that are necessary in both scenarios. A research programme was designed to (a) develop a standard methodology for analysing ink samples in a reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in forensic contexts. This report focuses on the last of the three stages of the research programme. The calibration and acquisition process and the mathematical comparison algorithms were described in previous papers [C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part I: Development of a quality assurance process for forensic ink analysis by HPTLC, Forensic Sci. Int. 185 (2009) 29-37; C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science- Part II: Development and testing of mathematical algorithms for the automatic comparison of ink samples analysed by HPTLC, Forensic Sci. Int. 185 (2009) 38-50]. In this paper, the benefits and challenges of the proposed concepts are tested in two forensic contexts: (1) ink identification and (2) ink evidential value assessment. The results show that different algorithms are better suited for different tasks. This research shows that it is possible to build digital ink libraries using the most commonly used ink analytical technique, i.e. high-performance thin layer chromatography, despite its reputation of lacking reproducibility. More importantly, it is possible to assign evidential value to ink evidence in a transparent way using a probabilistic model. It is therefore possible to move away from the traditional subjective approach, which is entirely based on experts' opinion, and which is usually not very informative. While there is room for the improvement, this report demonstrates the significant gains obtained over the traditional subjective approach for the search of ink specimens in ink databases, and the interpretation of their evidential value.
Resumo:
We make a numerical study of the effect that spatial perturbations have in normal Saffman-Taylor fingers driven at constant pressure gradients. We use a phase field model that allows for spatial variations in the Hele-Shaw cell. We find that, regardless of the specific way in which spatial perturbations are introduced, a lateral instability develops on the sides of the propagating Saffman-Taylor finger. Moreover, the instability exists regardless of the intensity of spatial perturbations in the cell as long as the perturbations are felt by the finger tip. If, as the finger propagates, the spatial perturbations felt by the tip change, the instability is nonperiodic. If, as the finger propagates, the spatial perturbations felt by the tip are persistent, the instability developed is periodic. In the later case, the instability is symmetrical or asymmetrical depending on the intensity of the perturbation.