932 resultados para mini-screws


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study we analyzed possible damages that vaporization from laser radiation could cause to implant material. Fifteen standard titanium implants, measuring 3.75 mm in diameter by 7 mm in length, were placed into the upper and lower jaws of three dogs according to Branemark's system. After osseointegration, all implants were exposed. In group I (control) conventional exposure with a punch was used; in group II, a CO2 laser with 2 W (power density: 256 W/cm(2); fluency: 0.077 J/cm(2), and a pulse mode of 0.30 ms) was used, and in group III 4 W (power density: 512 W/cm(2), fluency: 0.154 J/cm(2), and a pulse mode of 0.30 ms) was used. After vaporization, the cover screws were removed and sent for metallographic examination. The results showed that cover screws irradiated with 2 and 4 W power caused no superficial or microstructural alteration. The results also showed that the prescribed power densities, fluencies, and the use of the pulse mode were suitable for exposing implants without damage to tissue or implant material. (C) 2002 Laser Institute of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The objective of this study was to carry out a comparative evaluation of the mechanical resistance of 2 rigid internal fixation techniques for fractures of the mandibular condyle using miniplates.Materials and Methods: Fort), polyurethane resin replicas of human hemimandibles were used. The hemimandibles were sectioned to simulate a high subcondylar fracture and then stabilized with 2 fixing techniques using 2.0-mm system plates and screws. The fixation techniques were 2 separate 4-hole plates with 8 screws, and 2 overlaid 4-hole plates with 4 screws. Each system was submitted to load tests, with the application of the load in mediolateral and anteroposterior directions in an Instron 4411 universal assay machine (Instron, Norwood, MA).Results: Load values and peak displacement were measured. Means and standard deviations were evaluated by analysis of variance (P < .05) and Tukey tests, in which it was verified that the anteroposterior peak load value was affected by the arrangement of the plates on the models, although no differences were observed between the groups for the mediolateral peak load. The arrangement of the plates did not have any influence on peak displacement. Similarly, the final value of the mediolateral load was not affected by the arrangement of the plates on the model.Conclusion: The experimental model with 2 separate plates was statistically superior to the model with 2 overlaid plates only in relation to anteroposterior peak load. Despite showing superiority in mediolateral peak load and peak displacement, there was no statistical difference between the groups for these parameters. (C) 2009 American Association of Oral and Maxillofacial Surgeons

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Brazilian orthopaedic company designed a stainless steel plate called Synthesis Pengo System (S.P.S.), which has one fixed and one changeable extremity. According to the assembly of the changeable extremity, it is possible to obtain dynamization or neutralization of the fracture site. Since the S.P.S. plate was developed for use in human patients, the aim of this study was to evaluate this system in long-bone diaphyseal fractures in dogs. Eight dogs with closed diaphyseal fractures of the femur (n = 1), radius and ulna (n = 5), and tibia (n = 2) were used. Patients were aged seven months to three years and weighed 18 to 31.2 kg. The S.P.S. plate was assembled with one fixed extremity and one changeable extremity in dynamization mode. The trail bar was positioned for synthesis modules with holes for cortical screws. The modules were positioned close to one another in two fractures and for away from the fracture site in the others. The bone healing occurred by external callus. Since motion at the fracture site determines the amount of callus required, the secondary bone healing that was observed in all of the cases indicated less rigid fixation of this system. A potential benefit of this system was a lesser interface contact with the bone since it was only done by trail bar. The major disadvantage was the prominence of the implant. It was possible to conclude that the S.P.S. plate appears to be a suitable method for the treatment of diaphyseal fractures in dogs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the integration of implants installed using a surgical guide in augmented sites with autologous bone or deproteinized bovine bone mineral (DBBM) blocks, concomitantly with a collagen membrane.Material and methods: Mandibular molars were extracted bilaterally in six Labrador dogs, the buccal bony wall was removed, and a box-shaped defect was created. After 3 months, flaps were elevated, a bony graft was harvested from the ascending ramus, and secured to the lateral wall of the defect by means of screws. In the left mandibular side, a DBBM block was fixed into the defect. A resorbable membrane was applied at both sides, and the flaps were sutured. After 3 months, flaps were elevated, and a customized device was used as surgical guide to prepare the recipient sites in the interface between grafts and parent bone. One implant was installed in each side of the mandible. After 3 months, biopsies were harvested, and ground sections were prepared for histologic evaluation.Results: One autologous bone block graft was lost before implant installation. The width of the alveolar crest at the test sites (DBBM) was 5.4 +/- 1.2 mm before, 9.4 +/- 1.2 mm immediately after grafting, and 9.3 +/- 1 mm at implant installation. At the control sites (autologous bone), the corresponding values were: 5.2 +/- 1, 9 +/- 1.2, and 8.7 +/- 0.9 mm, respectively. All implants installed were available for histologic evaluation (n = 5). The autologous bone grafts, rich in vessels and cells, were integrated in the parent bone, and only little non-vital bone was found. The BIC% was 56.7 +/- 15.6% and 54.2 +/- 13.2% at the buccal and lingual aspects, respectively. At the test sites, the DBBM appeared to be embedded into connective tissue, and very little newly formed bone was encountered within the grafts. The BIC% was 5.8 +/- 12.3% and 51.3 +/- 14.2% at the buccal and lingual aspects, respectively.Conclusions: Autologous bone blocks used to augment the alveolar bony crest horizontally allowed the complete osseointegration of implants installed after 3 months of healing. However, similar blocks of DBBM did not promote osseointegration, although the installed implants were stable owing to the osseointegration in the sites of the parent bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The nutritional status of the aging individual results from a complex interaction between personal and environmental factors. A disease influences and is influenced by the nutritional status and the functional capacity of the individual. We asses the relationship between nutritional status and indicators of functional capacity among recently hospitalized elderly in a general hospital.Methods: A cross-sectional study was done with 240 elderly (women, n = 127 and men, n = 113) hospitalized in a hospital that provides care for the public and private healthcare systems. The nutritional status was classified by the MNA (Mini Nutritional Assessment) into: malnourished, risk of malnutrition and without malnutrition (adequate). The functional autonomy indicators were obtained by the self-reported Instrumental Activity of Daily Living (IADL) and Activity of Daily Living (ADL) questionnaire. The chi-square test was used to compare the proportions and the level of significance was 5%.Results: Among the assessed elderly, 33.8% were classified as adequate regarding nutritional status; 37.1% were classified as being at risk of malnutrition and 29.1% were classified as malnourished. All the IADL and ADL variables assessed were significantly more deteriorated among the malnourished individuals. Among the ADL variables, eating partial (42.9%) or complete (12.9%) dependence was found in more than half of the malnourished elderly, in 13.4% of those at risk of malnutrition and in 2.5% of those without malnutrition.Conclusion: There is an interrelationship between the nutritional status of the elderly and reduced functional capacity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cold-formed steel shapes have been widely employed in steel construction, where they frequently offer a lower cost solution than do traditional laminated shapes. A classic application of cold-formed steel shapes is purlins in the roof panel of industrial buildings, connected to the roof panel by means of screws. The combined effect of these two elements has been the subject of investigations in some countries. Design criteria were included in the AISI Code in 1991 and 1996. This paper presents and discusses the results obtained from bending tests carried out on shapes commonly used in Brazil, i.e., the channel and the simple lipped channel, Tests were carried out on double shapes with 4.5 and 6.0 meter spans, which were subjected to concentrated loads and braced against each other on the supports and at intermediary points in three different load situations. The panel shape was also analyzed experimentally, simulating the action of wind by means of a vacuum box designed specifically for this purpose. The test results were then compared to those obtained through the theoretical analysis, enabling us to extract important information upon which to base proposed design criteria for the new Brazilian code.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the synthesis and characterization of 2-aminothiazole modified silica gel (SiAT), and the results of a study of the adsorption and pre-concentration (in batch and using a flow-injection system coupled to an absorption atomic spectrometer) of Cu(II), Ni(II) and Pb(II) in aqueous medium. The adsorption capacities for each metal ions in mmol g -1 were: Cu(II)= 1.18, Ni(II)= 1.15 and Pb(II)= 1.10. The results obtained in the flow experiments showed a recovery of practically 100% of the metal ions adsorbed in a mini-column packed with 100 mg of SiAT, using 100 μL of 2.0 mol L -1 HCl solution as eluent. The sorption-desorption of the metal ions made possible the application of a flow-injection system for the pre-concentration and quantification by FAAS of metal ions at trace level in natural water samples digested and not digest by an oxidizing UV photolysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to compare by qualitative histology the efficacy of rigid internal fixation with titanium system and the Lacto Sorb® system in mandibular fractures in rabbits. Thirty male adult rabbits Oryctolagus cuniculus were used. Unilateral mandibular osteotomies were performed between the canine and first premolar. The animals were divided into two groups: for Group I - rigid internal fixation was performed with titanium system 1.5 mm (Synthes, Oberdorf, Switzerland), with two screws of 6 mm (bicortical) on each side of the osteotomy. For Group II-rigid internal fixation was performed with PLLA/PGA system 1.5 mm (Lacto Sorb®, WLorenz, Jacksonville, FL, USA). The histological analysis evaluated the presence of inflammatory reaction, degree of bone healing and degree of resorption of the Lacto Sorb® screws. The results of both fixation systems were similar, only with a small difference after 15 and 30 days. In Group I a faster bony healing was noted. But after 60 days, bony healing was similar in both groups. It is concluded that both PLLA/PGA and titanium plates and screws provide sufficient strength to permit mandibular bone healing. The resorption process of PLLA/PGA osteosynthesis material did not cause acute or chronic inflammatory reaction or foreign body reaction during the studied period. © 2004 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The background of prodrug design is presented herein as the basis for introducing new and advanced latent systems, taking into account mainly the versatility of polymers and other macromolecules as carriers. PDEPT (Polymer-Directed Enzyme Prodrug Therapy); PELT (Polymer-Enzyme Liposome Therapy); CDS (Chemical Delivery System); ADEPT(Antibody-Directed Enzyme Prodrug Therapy); GDEPT/VDEPT (Gene-Directed Enzyme Prodrug Therapy/Virus-Directed Enzyme Prodrug Therapy); ODDS (Osteotropic Drug Delivery System) and LEAPT (Lectin-directed enzyme-activated prodrug therapy) are briefly described and some examples are given. © 2005 Bentham Science Publishers Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Depression is a highly prevalent illness among institutionalized aged and assumes peculiar characteristics such as the risk for progressing to dementia. The aims of this study was to assess the cognitive functions of institutionalized elderly with clinical diagnosis of depression and compare the severity of depressive symptoms with cognitive performance. From 120 residents at a nursing home in Rio Claro, Brazil, we study 23 individuals (mean age: 74.3 years; mean schooling: 4.0 years) with diagnosis of depression. At first, a clinical diagnosis of depression and measurement of its symptoms using the Geriatric Depression Scale were performed. The patient then underwent a neuropsychological assessment based on the following tests: Mini-Mental Examination, Verbal Fluency, Visual Perception, Immediate Memory, Recent Memory, Recognition, Clock Drawing Test. The patients were divided into two groups: those with less severe depression symptoms (Group 1: N=9) and more severe symptoms (Group 2: N=14). The significant difference between symptom severity of the two groups was p=0.0001. Patients with more severe symptoms revealed a slightly inferior cognitive performance in most of the tests when compared to those with less severe symptoms (p>0.05). In relation to Verbal Fluency, patients with more severe depression symptoms presented a significantly inferior cognitive performance when compared to those with less severe symptoms (p=0.0082). Verbal Fluency revealed to be a more sensitive test for measuring early cognitive alterations in institutionalized aged with depression, and appears to be a useful resource in monitoring the cognitive functions of patients faced with the risk of dementia. © Copyright Moreira Jr. Editora.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research studies the influence of the pozzolanic activity of the calcareous and basalt in the resistence behavior of the compressive strength of high performance self-compacting concrete (HPSCC). The selected aditives are the calcareous filler and basalt filler, for they are industrial residues helping that way the sustainable development. The paste of this concrete type is constituted of cement, silica fume, calcareous filler or basalt filler, water and superplasticizer additive. In this research the relationships water/cement are fixed in 0,40 kg/kg, silica fume/cement of 0,10 kg/kg and the relationships filler/cement and superplasticizer/cement are determined through of Marsh́s cone and mini-slump tests. The granular skeleton is gotten from a composition between quartzous sand and brita of basalt that presents the lesser index of emptinesses. The results show that the HPSCC with the addition of calcareous filler has greater compressive strength than what the HPSCC with addition of basalt filler in the ages of 7, 28 and 63 days. It is explained by the fact that the calcareous filler presents greater index of pozzolanic activity than the basalt filler. Besides that the relation water/fine for the HPSCC with calcareous filler is 0,27 l/kg whereas the HPSCC with basalt filler is of 0,29 l/kg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Impairment in non-motor functions such as disturbances of some executive functions are also common events in Parkinson's disease patients. Objective: To verify the performance of Parkinson's disease patients in activities requiring visuoconstructive and visuospatial skills. Method: Thirty elderly patients with mild or moderate stages of Parkinson's disease were studied. The assessment of the clinical condition was based on the unified Parkinson's disease rating scale (56.28; SD=33.48), Hoehn and Yahr (2.2; SD=0.83), Schwab and England (78.93%), clock drawing test (7.36; SD=2.51), and mini-mental state examination (26.48; SD=10.11). Pearson's correlation and stepwise multiple regression were used for statistical analyses. Results: The patients presented deterioration in visuospatial and visuoconstructive skills. Conclusion: The clock drawing test proved to be a useful predictive tool for identifying early cognitive impairment in these individuals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work used four cylindrical PVC (polyvinyl chloride) mini compost bins, they all had the same size and were identical, with 40 cm diameter and 75 cm length, they also were opened on both sides. Each mini compost bean received 35,5 kg of solid organic wastes, which were previously crushed and 6 kg of sawdust. It was evaluated during the composting process the C/N analyses, temperature measurement, humidity and pH. Results showed that the use of sawdust as a source of high carbon inputs on the mini compost beans and using low quantities of organic solid wastes reached temperatures as high as 65° C, keeping on the thermophilic phase for almost 6 days. After 18 days the environmental temperature was reached, the organic wastes were then laid to reach full maturity for 55 more days. The C/N ratio was initially around 30/1 and after 73 days it was around 12/1.