929 resultados para internal P loading


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various studies have been conducted to investigate the effects of impact loading on cartilage damage and chondrocyte death. These have shown that the rate and magnitude of the applied strain significantly influence chondrocyte death, and that cell death occurred mostly in the superficial zone of cartilage suggesting the need to further understand the fundamental mechanisms underlying the chondrocytes death induced at certain levels of strain-rate. To date there is no comprehensive study providing insight on this phenomenon. The aim of this study is to examine the strain-rate dependent behavior of a single chondrocyte using a computational approach based on Finite Element Method (FEM). An FEM model was developed using various mechanical models, which were Standard Neo-Hookean Solid (SnHS), porohyperelastic (PHE) and poroviscohyperelastic (PVHE) to simulate Atomic Force Microscopy (AFM) experiments of chondrocyte. The PVHE showed, it can capture both relaxation and loading rate dependent behaviors of chondrocytes, accurately compared to other models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Deprotonated o, m-, and p-methoxyacetanilide show pronounced peaks in their collision-induced tandem mass spectra (MS/MS) produced by losses of the elements of C2H6. It is proposed that this reaction is a 'cross-ring' internal S(N)2 reaction involving an incipient methyl anion. For example, p-CH3O-C6H4-N--CO-CH3--> [(p.CH3O-C6H4-N=C=O)CH3-]--> O---C6H4-N=C=O+C2H6.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is proposed to describe force or compound muscle action potential (CMAP) trace data collected in an electromyography study for motor unit number estimation (MUNE). Experimental data was collected using incre- mental stimulation at multiple durations. However, stimulus information, vital for alternate MUNE methods, is not comparable for multiple duration data and therefore previous methods of MUNE (Ridall et al., 2006, 2007) cannot be used with any reliability. Hypothesised ring combinations of motor units are mod- elled using a multiplicative factor and Bayesian P-spline formulation. The model describes the process for force and CMAP in a meaningful way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drawing on principles of social exchange this thesis employs mediated regression to investigate the relationship between internal communication and employee engagement in the Australian workforce. Findings suggest organisations and supervisors should focus internal communication efforts toward building greater perceptions of support and stronger identification among employees in order to foster optimal engagement. This research contributes to public relations and management scholarship through understanding how perceived support and identification act as mediating mechanisms in the relationship between internal communication and employee engagement at the organisational and supervisory level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Quality of life (QOL) measures are an important patient-relevant outcome measure for clinical studies. Currently there is no fully validated cough-specific QOL measure for paediatrics. The objective of this study was to validate a cough-specific QOL questionnaire for paediatric use. Method 43 children (28 males, 15 females; median age 29 months, IQR 20–41 months) newly referred for chronic cough participated. One parent of each child completed the 27-item Parent Cough-Specific QOL questionnaire (PC-QOL), and the generic child (Pediatric QOL Inventory 4.0 (PedsQL)) and parent QOL questionnaires (SF-12) and two cough-related measures (visual analogue score and verbal category descriptive score) on two occasions separated by 2–3 weeks. Cough counts were also objectively measured on both occasions. Results Internal consistency for both the domains and total PC-QOL at both test times was excellent (Cronbach alpha range 0.70–0.97). Evidence for repeatability and criterion validity was established, with significant correlations over time and significant relationships with the cough measures. The PC-QOL was sensitive to change across the test times and these changes were significantly related to changes in cough measures (PC-QOL with: verbal category descriptive score, rs=−0.37, p=0.016; visual analogue score, rs=−0.47, p=0.003). Significant correlations of the difference scores for the social domain of the PC-QOL and the domain and total scores of the PedsQL were also noted (rs=0.46, p=0.034). Conclusion The PC-QOL is a reliable and valid outcome measure that assesses QOL related to childhood cough at a given time point and measures changes in cough-specific QOL over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show, using the PDR1 element of pea, that dispersed repeated sequences of moderate copy number can be used simply and efficiently to generate markers linked to a trait of interest. Inspection of hybridization patterns of repeated sequences to DNA mixtures of pooled genotypes is a sensitive way of detecting such markers. The large number of bands in tracks of digests of these mixtures allows the simultaneous sampling of loci at many places in the genome, and the many unlinked loci serve as internal controls. It is also shown that intensity ratios calculated from these band differences can be used to give a rough estimate of linkage distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study investigates uncertainties pertaining to the use of optically stimulated luminescence dosimeters (OSLDs) in radiotherapy dosimetry. The sensitivity of the luminescent material is related to the density of recombination centres [1], which is in the range of 1015–1016 cm-3. Because of this non-uniform distribution of traps in crystal growth the sensitivity varies substantially within a batch of dosimeters. However, a quantitative understanding of the relationship between the response of an OSLD and its sensitive volume has not yet been investigated or reported in literature. Methods In this work, OSLDs are scanned with a MicroCT scanner to determine potential sources for the variation in relative sensitivity across a selection of Landauer nanoDot dosimeters. Specifically, the correlation between a dosimeters relative sensitivity and the loading density of Al2O3:C powder was determined. Results When extrapolating the sensitive volume’s radiodensity from the CT data, it was shown that there is a non-uniform distribution incrystal growth as illustrated in Fig. 1. A plot of voxel count versus the element-specific correction factor is shown in Fig. 2 where each point represents a single OSLD. A line was fitted which has an R2-value of 0.69 and a P-value of 8.21 9 10-19. This data shows that the response of a dosimeter decreases proportionally with sensitive volume. Extrapolating from this data, a quantitative relationship between response and sensitive volume was roughly determined for this batch of dosimeters. A change in volume of 1.176 9 10-5 cm3 corresponds to a 1 % change in response. In other words, a 0.05 % change in the nominal volume of the chip would result in a 1 % change in response. Discussion and conclusions This work demonstrated that the amount of sensitive material is approximately linked to the total correction factor. Furthermore, the ‘true’ volume of an OSLD’s sensitive material is, on average, 17.90 % less than that which has been reported in literature, mainly due to the presence of air cavities in the material’s structure. Finally, the potential effects of the inaccuracy of Al2O3:C deposition increases with decreasing chip size. If a luminescent dosimeter were manufactured with a smaller volume than currently employed using the same manufacturing protocol, the variation in response from chip to chip would more than likely exceed the current 5 % range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Recently, Taylor et al. reported that use of the BrainLAB m3 microMLC, for stereotactic radiosurgery, results in a decreased out-of-field dose in the direction of leaf-motion compared to the outof- field dose measured in the direction orthogonal to leaf-motion [1]. It was recommended that, where possible, patients should be treated with their superior–inferior axes aligned with the microMLCs leafmotion direction, to minimise out-of-field doses [1]. This study aimed, therefore, to examine the causes of this asymmetry in outof- field dose and, in particular, to establish that a similar recommendation need not be made for radiotherapy treatments delivered by linear accelerators without external micro-collimation systems. Methods Monte Carlo simulations were used to study out-of-field dose from different linear accelerators (the Varian Clinacs 21iX and 600C and the Elekta Precise) with and without internal MLCs and external microMLCs [2]. Results Simulation results for the Varian Clinac 600C linear accelerator with BrainLAB m3 microMLC confirm Taylor et als [1] published experimental data. The out-of-field dose in the leaf motion direction is deposited by lower energy (more obliquely scattered) photons than the out-of-field dose in the orthogonal direction. Linear accelerators without microMLCs produce no asymmetry in out-offield dose. Conclusions The asymmetry in out-of-field dose previously measured by Taylor et al. [1] results from the shielding characteristics of the BrainLAB m3 microMLC device and is not produced by the linear accelerator to which it is attached.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To test a conceptual model linking parental physical activity orientations, parental support for physical activity, and children's self-efficacy perceptions with physical activity participation. Participants and setting The sample consisted of 380 students in grades 7 through 12 (mean age, 14.0±1.6 years) and their parents. Data collection took place during the fall of 1996. Main outcome measures Parents completed a questionnaire assessing their physical activity habits, enjoyment of physical activity, beliefs regarding the importance of physical activity, and supportive behaviors for their child's physical activity. Students completed a 46-item inventory assessing physical activity during the previous 7 days and a 5-item physical activity self-efficacy scale. The model was tested via observed variable path analysis using structural equation modeling techniques (AMOS 4.0). Results An initial model, in which parent physical activity orientations predicted child physical activity via parental support and child self-efficacy, did not provide an acceptable fit to the data. Inclusion of a direct path from parental support to child physical activity and deletion of a nonsignificant path from parental physical activity to child physical activity significantly improved model fit. Standardized path coefficients for the revised model ranged from 0.17 to 0.24, and all were significant at the p<0.0001 level. Conclusions Parental support was an important correlate of youth physical activity, acting directly or indirectly through its influence on self-efficacy. Physical activity interventions targeted at youth should include and evaluate the efficacy of individual-level and community-level strategies to increase parents’ capacity to provide instrumental and motivational support for their children's physical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The alkaline perhydrolysis of the nerve agent O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothioate (VX) was investigated by studying the ion-molecule reactions of HOO(-) with O,S-dimethyl methylphosphonothioate in a modified linear ion-trap mass spectrometer. In addition to simple proton transfer, two other abundant product ions are observed at m/z 125 and 109 corresponding to the S-methyl methylphosphonothioate and methyl methylphosphonate anions, respectively. The structure of these product ions is demonstrated by a combination of collision-induced dissociation and isotope-labeling experiments that also provide evidence for their formation by nucleophilic reaction pathways, namely, (i) S(N)2 at carbon to yield the S-methyl methylphosphonothioate anion and (ii) nucleophilic addition at phosphorus affording a reactive pentavalent intermediate that readily undergoes internal sulfur oxidation and concomitant elimination of CH(3)SOH to yield the methyl methylphosphonate anion. Consistent with previous Solution phase observations of VX perhydrolysis, the toxic P-O cleavage product is not observed in this VX model system and theoretical calculations identify P-O cleavage to be energetically uncompetitive. Conversely, intramolecular sulfur oxidation is calculated to be extremely exothermic and kinetically accessible explaining its competitiveness with the facile gas phase proton transfer process. Elimination of a sulfur moiety deactivates the nerve agent VX and thus the intramolecular sulfur oxidation process reported here is also able to explain the selective perhydrolysis of the nerve agent to relatively nontoxic products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validity of fatigue protocols involving multi-joint movements, such as stepping, has yet to be clearly defined. Although surface electromyography can monitor the fatigue state of individual muscles, the effects of joint angle and velocity variation on signal parameters are well established. Therefore, the aims of this study were to i) describe sagittal hip and knee kinematics during repetitive stepping ii) identify periods of high inter-trial variability and iii) determine within-test reliability of hip and knee kinematic profiles. A group of healthy men (N = 15) ascended and descended from a knee-high platform wearing a weighted vest (10%BW) for 50 consecutive trials. The hip and knee underwent rapid flexion and extension during step ascent and descent. Variability of hip and knee velocity peaked between 20-40% of the ascent phase and 80-100% of the descent. Significant (p<0.05) reductions in joint range of motion and peak velocity during step ascent were observed, while peak flexion velocity increased during descent. Healthy individuals use complex hip and knee motion to negotiate a knee-high step with kinematic patterns varying across multiple repetitions. These findings have important implications for future studies intending to use repetitive stepping as a fatigue model for the knee extensors and flexors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thinking of cutting physical education? Think again. Even as we bemoan children's sedentary lifestyles, we often sacrifice school-based physical education in the name of providing more time for academics. In 2006, only 3.8 percent of elementary schools, 7.9 percent of middle schools, and 2.1 percent of high schools offered students daily physical education or its equivalent for the entire school year (Lee, Burgeson, Fulton, & Spain, 2007). We believe this marked reduction in school-based physical activity risks students' health and can't be justified on educational or ethical grounds. We'll get to the educational grounds in a moment. As to ethical reasons for keeping physical activity part of our young people's school days, consider the fact that childhood obesity is now one of the most serious health issues facing U.S. children (Ogden et al., 2006). School-based physical education programs engage students in regular physical activity and help them acquire skills and habits necessary to pursue an active lifestyle. Such programs are directly relevant to preventing obesity. Yet they are increasingly on the chopping block.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One cannot help but be impressed by the inroads that digital oilfield technologies have made into the exploration and production (E&P) industry in the past decade. Today’s production systems can be monitored by “smart” sensors that allow engineers to observe almost any aspect of performance in real time. Our understanding of how reservoirs are behaving has improved considerably since the dawn of this revolution, and the industry has been able to move away from point answers to more holistic “big picture” integrated solutions. Indeed, the industry has already reaped the rewards of many of these kinds of investments. Many billions of dollars of value have been delivered by this heightened awareness of what is going on within our assets and the world around them (Van Den Berg et al. 2010).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Standing radiographs are the ‘gold standard’ for clinical assessment of adolescent idiopathic scoliosis (AIS), with the Cobb Angle used to measure the severity and progression of the scoliotic curve. Supine imaging modalities can provide valuable 3D information on scoliotic anatomy, however, due to changes in gravitational loading direction, the geometry of the spine alters between the supine and standing position which in turn affects the Cobb Angle measurement. Previous studies have consistently reported a 7-10° [1-3] Cobb Angle increase from supine to standing, however, none have reported the effect of endplate pre-selection and which (if any) curve parameters affect the supine to standing Cobb Angle difference. Methods Female AIS patients with right-sided thoracic major curves were included in the retrospective study. Clinically measured Cobb Angles from existing standing coronal radiographs and fulcrum bending radiographs [4] were compared to existing low-dose supine CT scans taken within 3 months of the reference radiograph. Reformatted coronal CT images were used to measure Cobb Angle variability with and without endplate pre-selection (end-plates selected on the radiographs used on the CT images). Inter and intra-observer measurement variability was assessed. Multi-linear regression was used to investigate whether there was a relationship between supine to standing Cobb Angle change and patient characteristics (SPSS, v.21, IBM, USA). Results Fifty-two patients were included, with mean age of 14.6 (SD 1.8) years; all curves were Lenke Type 1 with mean Cobb Angle on supine CT of 42° (SD 6.4°) and 52° (SD 6.7°) on standing radiographs. The mean fulcrum bending Cobb Angle for the group was 22.6° (SD 7.5°). The 10° increase from supine to standing is consistent with existing literature. Pre-selecting vertebral endplates was found to increase the Cobb Angle difference by a mean 2° (range 0-9°). Multi-linear regression revealed a statistically significant relationship between supine to standing Cobb Angle change with: fulcrum flexibility (p=0.001), age (p=0.027) and standing Cobb Angle (p<0.001). In patients with high fulcrum flexibility scores, the supine to standing Cobb Angle change was as great as 20°.The 95% confidence intervals for intra-observer and inter-observer measurement variability were 3.1° and 3.6°, respectively. Conclusion There is a statistically significant relationship between supine to standing Cobb Angle change and fulcrum flexibility. Therefore, this difference can be considered a measure of spinal flexibility. Pre-selecting vertebral endplates causes only minor changes.