959 resultados para heart surgery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Commentary on

Rautiainen S, Levitan EB, Mittleman MA, et al. Total antioxidant capacity of diet and risk of heart failure: a population-based prospective cohort of women. Am J Med 2013;126:494–500.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background

Although life expectancy continues to increase in the Republic of Ireland (ROI) and Northern Ireland (NI), coronary heart disease (CHD) remains a leading cause of death and disability in older adults. Some, but not all, of the socioeconomic inequality in cardiovascular disability can be explained by a social gradient in conventional risk factors. The aims of the research were to assess CHD-related disability, and to establish the prevalence and population attributable fractions (PAFs) of risk factors for CHD-related disability across gender and socioeconomic groups in older adults in NI and ROI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Foreskin surgical procedures such as circumcision, prepuceplasty, frenuloplasty, dorsal slit, reduction of paraphimosis etc. in the adult male is usually performed by both general surgeons and urologists. Our aim was to evaluate the acceptance of performing these procedures in the day procedure unit or in the emergency unit under penile block. 
Method: Fifty patients who underwent foreskin surgeries under local anaesthetic (LA) were evaluated with their experience. Twenty patients who underwent circumcision, 20 patients who underwent foreskin preserving operations such as frenuloplasty or prepuceplasty and 10 patients who underwent other procedures such as reduction of paraphimosis (five) and dorsal slit (five) were included inthe study. The patients were asked about their symptoms such as pain or discomfort during local infiltration of lignocaine, any discomfort during the actual procedure, post-operative discomfort and general acceptance. All the patients were given penile block using smaller size needle (25 gauge, 5/8th inch orange sterile luer slip hypodermic needle) and 1% plain lignocaine. Thirty doctors from general surgery (10), urology (10) and emergency medicine (10) participated in the survey. They were asked about their opinion, confidence and preference about performing foreskin surgical procedures under LA. This included both junior trainees, middle grade doctors and consultants. The majority of middle grade doctors and consultants were fairly confident in performing procedures under LA, whereas the junior trainees in surgery, urology and emergency were lacking confidence. 
Conclusion: Penile block is a safe and effective way ofproviding sufficient anaesthesia for foreskin surgeries. Thetechnique is easy to learn. It reduces post-operative pain aswell. It can reduce the risk and cost of administering generalanaesthesia. doctors who are in training surgical specialityand emergency medicine should be encouraged to learnthe principles and technique in administering penile block.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today there is a growing interest in the integration of health monitoring applications in portable devices necessitating the development of methods that improve the energy efficiency of such systems. In this paper, we present a systematic approach that enables energy-quality trade-offs in spectral analysis systems for bio-signals, which are useful in monitoring various health conditions as those associated with the heart-rate. To enable such trade-offs, the processed signals are expressed initially in a basis in which significant components that carry most of the relevant information can be easily distinguished from the parts that influence the output to a lesser extent. Such a classification allows the pruning of operations associated with the less significant signal components leading to power savings with minor quality loss since only less useful parts are pruned under the given requirements. To exploit the attributes of the modified spectral analysis system, thresholding rules are determined and adopted at design- and run-time, allowing the static or dynamic pruning of less-useful operations based on the accuracy and energy requirements. The proposed algorithm is implemented on a typical sensor node simulator and results show up-to 82% energy savings when static pruning is combined with voltage and frequency scaling, compared to the conventional algorithm in which such trade-offs were not available. In addition, experiments with numerous cardiac samples of various patients show that such energy savings come with a 4.9% average accuracy loss, which does not affect the system detection capability of sinus-arrhythmia which was used as a test case. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In a selective group of patients accelerated partial breast irradiation (APBI) might be applied after conservative breast surgery to reduce the amount of irradiated healthy tissue. The role of volumetric modulated arc therapy (VMAT) and voluntary moderately deep inspiration breath-hold (vmDIBH) techniques in further reducing irradiated healthy – especially heart – tissue is investigated.

Material and methods: For 37 partial breast planning target volumes (PTVs), three-dimensional conformal radiotherapy (3D-CRT) (3 – 5 coplanar or non-coplanar 6 and/or 10 MV beams) and VMAT (two partial 6 MV arcs) plans were made on CTs acquired in free-breathing (FB) and/or in vmDIBH. Dose-volume parameters for the PTV, heart, lungs, and breasts were compared. 

Results: Better dose conformity was achieved with VMAT compared to 3D-CRT (conformity index 1.24 0.09 vs. 1.49 0.20). Non-PTV ipsilateral breast receiving 50% of the prescribed dose was on average reduced by 28% in VMAT plans compared to 3D-CRT plans. Mean heart dose (MHD) reduced from 2.0 (0.1 – 5.1) Gy in 3D-CRT(FB) to 0.6 (0.1 – 1.6) Gy in VMAT(vmDIBH). VMAT is benefi cial for MHD reduction if MHD with 3D-CRT exceeds 0.5Gy. Cardiac dose reduction as a result of VMAT increases with increasing initial MHD, and adding vmDIBH reduces the cardiac dose further. Mean dose to the ipsilateral lung decreased from 3.7 (0.7 – 8.7) to 1.8 (0.5 – 4.0) Gy with VMAT(vmDIBH) compared to 3D-CRT(FB). VMAT resulted in a slight increase in the contralateral breast dose (DMean ) always remaining 1.9 Gy). 

Conclusions: For APBI patients, VMAT improves PTV dose conformity and delivers lower doses to the ipsilateral breast and lung compared to 3D-CRT. This goes at the cost of a slight but acceptable increase of the contralateral breast dose. VMAT reduces cardiac dose if MHD exceeds 0.5 Gy for 3D-CRT. Adding vmDIBH results in a further reduction of heart and ipsilateral lung dose. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucagon-like peptide-1 (GLP-1) is an insulin-releasing hormone clinically exploited for glycaemic control in diabetes, which also confers acute cardioprotection and benefits in experimental/clinical heart failure. We specifically investigated the role of the GLP-1 mimetic, exendin-4, in post-myocardial infarction (MI) remodelling, which is a key contributor to heart failure. Adult female normoglycaemic mice underwent coronary artery ligation/sham surgery prior to infusion with exendin-4/vehicle for 4 weeks. Metabolic parameters and infarct sizes were comparable between groups. Exendin-4 protected against cardiac dysfunction and chamber dilatation post-MI and improved survival. Furthermore, exendin-4 modestly decreased cardiomyocyte hypertrophy/apoptosis but markedly attenuated interstitial fibrosis and myocardial inflammation post-MI. This was associated with altered extracellular matrix (procollagen IαI/IIIαI, connective tissue growth factor, fibronectin, TGF-β3) and inflammatory (IL-10, IL-1β, IL-6) gene expression in exendin-4-treated mice, together with modulation of both Akt/GSK-3β and Smad2/3 signalling. Exendin-4 also altered macrophage response gene expression in the absence of direct actions on cardiac fibroblast differentiation, suggesting cardioprotective effects occurring secondary to modulation of inflammation. Our findings indicate that exendin-4 protects against post-MI remodelling via preferential actions on inflammation and the extracellular matrix independently of its established actions on glycaemic control, thereby suggesting that selective targeting of GLP-1 signalling may be required to realise its clear therapeutic potential for post-MI heart failure.