1000 resultados para ferrous ion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e mu A of O7+, 505 e mu A of Xe20+ 306 e mu A of Xe27+, and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

癌症是现代医学的难题,一直危害着人类的健康。放射治疗是癌症治疗的有效手段之一。由于重离子束在物理学和生物学性质上所具有的优势,它已成为放疗用的最佳射线。简述了重离子治癌的发展历程、现状以及特点,详细讨论了在医学物理和放射生物学研究领域值得关注的若干热点问题。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

从采集的土壤样品中分离筛选出一株碱性蛋白酶产生菌G-41,经16S rRNA分子鉴定为芽孢杆菌属菌株。该菌株在发酵培养基中能产生较高产量的胞外碱性蛋白酶(1.7×104U/mL)。以G-41为出发菌株,对其进行重离子辐照诱变处理,获得突变株G-41-68,将该突变株再次经重离子诱变,从大量突变株中筛选出碱性蛋白酶高产菌株15Gy-54,其酶活力达到6.22×104U/mL。与出发菌株相比较,突变株G-41-68和15Gy-54的酶活力分别提高了1.58倍和2.65倍。对突变株15Gy-54的发酵条件进行了优化研究,结果表明,该菌株的碱性蛋白酶活力得到进一步提高,达到7.18×104U/mL,其最适发酵条件为:培养基(g/100mL)为胰蛋白胨1、酵母膏0.5、乳糖5、Na2HPO4·12H2O0.4、KH2PO40.03、Na2CO30.1、MgSO40.0481(4×10-3mol/L)、pH8.0,培养温度41℃,振荡培养时间42-48h。实验结果表明,重离子辐照诱变技术是一种非常有效的微生物诱变育种新技术。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

目的:评价重离子束对皮肤恶性肿瘤放射治疗的近期疗效和毒副反应。方法:29例皮肤恶性肿瘤患者分6批接受重离子束放射治疗,其中恶性黑色素瘤13例,皮肤鳞癌及Bowen’s病各6例,基底细胞癌2例,其他皮肤恶性肿瘤2例。照射总剂量(50~70)GyE/(6~12)d,单次剂量5.5~11.67GyE,1f/d,连续治疗。采用RTOG标准和WHO近期疗效标准分别评价毒副反应和近期疗效。结果:截止2009-05,中位随访时间为13.5个月(1~25个月),随访率为100%。29例患者中完全缓解(CR)24例(82.8%),部分缓解(PR)5例(17.2%),有效率(RR)为100%,中位生存时间为22.8个月(95%CI:20.6~24.9)。皮肤反应0度11例(37.9%),Ⅰ度9例(31.0%),Ⅱ度6例(20.7%),Ⅲ度2例(6.9%),Ⅳ度1例(3.4%);血液毒副反应治疗前后无明显改变。结论:重离子束(12C6+)放射治疗皮肤恶性肿瘤近期疗效好,并发症轻,远期疗效、晚期副反应等尚需进一步长期全面的观察和更多的研究提供依据。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polypropylene (PP) microporous membranes were successfully prepared by swift heavy ion irradiation and track-etching. Polypropylene foils were irradiated with Au-197 ions of kinetic energy 11.4 MeV.u(-1) (total energy of 2245.8 MeV) and fluence 1x10(8) ions.cm(-2) at normal incidence. The damaged regions produced by the gold ions along the trajectories were etched in H2SO4 and K2Cr2O7 solutions leading to the formation of cylindrical pores in the membranes. The pore diameters of the PP microporous membranes increased from 380 to 1610 nm as the etching time increased from 5 to 30 min. The surface and cross-section morphologies of the porous membranes were characterized by scanning electron microscopy (SEM). The micropores in the membranes were found to be cylindrical in shape, homogeneous in distribution, and equal in size. Some mathematical relations of the porosity of the PP microporous membranes were established by analytic derivation. The microporous membranes were used in lithium-ion batteries to measure their properties as separators. The electrical conductivity of the porous membrane immersed in liquid electrolyte was found to be comparable to that of commercial separators by electrochemical impedance spectroscopy (EIS). The results showed that the porosity and electrical conductivity were dependent on the ion fluence and etching time. By adjusting these two factors, microporous membranes with good porosity and electrical conductivity were made that met the requirements for commercial use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

利用离子辐照结合径迹蚀刻方法制备聚丙烯(PP)微孔膜.用加速器产生的单核能为11.4MeV·u-1(总能量2245.8MeV)的197Au离子束辐照PP膜,剂量为1×108ions·cm-2.辐照后PP膜沿离子路径产生损伤区域,用硫酸与重铬酸钾的混合液进行蚀刻(5-30min),制备出孔径为380-1610nm的聚丙烯微孔膜.对膜的表面和断面形貌进行表征,微孔膜的孔径大小及空间分布均匀,孔道上下贯通,形状近似为圆柱形.给出了微孔膜的孔隙率理论公式.将制备的聚丙烯微孔膜用作锂离子电池隔膜,用电化学阻抗谱(EIS)测定浸满电解液的微孔膜的离子电导率,并与商用隔膜进行比较.分析表明辐照剂量和孔径大小均会影响膜的孔隙率和离子电导率,选择合适的辐照剂量和蚀刻时间,可以制备出孔隙率和离子电导率符合应用标准的聚丙烯微孔膜.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

枯草芽孢杆菌BJ1是一种在真菌病害防治中发挥重要作用的生防因子,为进一步提高它的抑菌能力,获得生防效果更好的高效菌种,利用不同能量和剂量的12C6+对生防菌BJ1进行了离子辐照处理。研究结果表明:离子辐照生防菌BJ1的最适宜剂量为200~400 Gy,传能线密度(LET)为60 keV/μm;突变菌株的抑菌能力比BJ1提高了2%~21%;不仅防病效果比BJ1提高了17.48%,而且对植物具有更好的促生长作用。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

用能量11.4MeV/u和注量1×108ions/cm2的197Au离子垂直辐照聚丙烯薄膜,通过电导测量法监测温度、硫酸浓度和重铬酸钾浓度对径迹蚀刻速率的影响,得到合适的蚀刻条件;成功制备出孔径范围在600—1000nm的重离子径迹聚丙烯孔膜,并用场发射扫描电镜对孔的形状及孔径大小进行了表征,对孔洞锥角的形成进行了分析,为重离子辐照技术制备锂离子电池隔膜提供了实验数据。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ZnO thin films were implanted at room temperature with 80 keV N+ or 400 keV Xe+ ions. The implantation fluences of N+ and Xe+ ranged from 5.0 x 10(14) to 1.0 x 10(17)/cm(2), and from 2.0 x 10(14) to 5.0 x 10(15)/cm(2), respectively. The samples were analyzed using Raman spectroscopy and the Raman scattering modes of the N- and Xe-ion implanted samples varying with implantation fluences were investigated. It was found that Raman peaks (bands) at 130 and 578 cm(-1) appeared in the spectra of ion-implanted ZnO samples, which are independent of the ion species, whereas a new peak at 274 cm(-1) was found only in N-ion implanted samples, and Raman band at 470 cm(-1) was found clearly in Xe-ion implanted samples. The relative intensity (peak area) increased with the increasing of the implantation fluences. From the comparison of the Raman spectra of N- and Xe-ion implanted ZnO samples and considering the damage induced by the ions, we analyzed the origin of the observed new Raman peaks (bands) and discussed the structure changes of ZnO films induced by N- and Xe-ion implantations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

室温下,用80keVN+和400keVXe+离子注入ZnO薄膜,注入剂量分别为5.0×1014—1.0×1017/cm2和2.0×1014—5.0×1015/cm2.利用拉曼散射技术对注入前后的ZnO薄膜进行光谱测量和分析,研究了样品的拉曼光谱随离子注入剂量的变化规律.实验结果发现,未进行离子注入的样品在99,435cm-1处出现两个ZnO六方纤锌相的特征峰E2low和E2high;N+和Xe+注入样品在130和578cm-1附近均出现新峰(包),N+注入样品还在274cm-1出现新峰,而Xe+注入样品在470cm-1附近出现另一新峰包,且这些新峰(包)的相对面积随注入剂量的增大而增大.通过N+和Xe+注入样品拉曼光谱的对比分析,并考虑到注入离子在样品中产生的原子位移损伤,对新峰(包)对应的振动模来源进行了分析,探索了离子注入在ZnO薄膜中引起的结构变化.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

介绍了中国科学院近代物理研究所重离子治癌装置的安装定位测量技术和方法。利用激光跟踪仪通过控制网的建立,和多重坐标系的转换,使最后的磁铁安装径向相对误差不超过±(0.05-0.1)mm,真空管道的横向及竖向精度也达到了±(0.1-0.2)mm。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

主环二极铁电源是兰州重离子加速器冷却储存环(HIRFL-CSR)工程的关键设备和指标要求最高的一台电源,采用了独特的拓扑和控制策略。为满足峰值功率3.15MW(3kA,1.45kV)的输出能力和快脉冲要求,采用了晶闸管整流并联脉宽调制补偿单元的主电路拓扑结构和特殊的控制方式,这套综合方案确保电源满足了全部技术指标。本文介绍了该拓扑结构的原理和优势,讨论了为满足±2×10-4的跟踪误差的要求而采用的控制拓扑和双基准给定的原理,并简介了调试过程和近年来的运行和改进情况。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

为了研究低速高电荷态离子在C60薄膜中引起的势效应,用能量为200keV的高电荷态Xen+(n=3,10,13,15,17,20,22,23)离子辐照了C60薄膜。用原子力显微镜(AFM)和Raman散射技术分析了辐照过程中高电荷态Xen+离子所储存势能在C60薄膜中引起的效应,即势效应。AFM分析结果表明,辐照C60薄膜的表面粗糙度随辐照Xen+离子电荷态(即势能)的增加而减小,揭示了势效应的存在。而Raman分析结果表明,由于Xe离子的动能远大于其所储存的势能,因此,尽管有表面势效应的影响,但在Raman分析的深度范围内,弹性碰撞还是主导了C60薄膜的损伤过程。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

中国科学院近代物理研究所基于兰州重离子研究装置(HIRFL/HIRFL-CSR),在被动型束流配送系统下采用二维分层适形照射治疗技术开展重离子治癌临床试验研究。为了更好地利用重离子束在肿瘤放射治疗中的生物物理优势并保障重离子临床治疗试验的顺利实施,一个初级版本的重离子治疗计划系统已经设计完成。此计划系统是针对被动型束流配送系统下的二维分层适形照射治疗方式来进行设计的。介绍了此系统的设计框架、可提供的功能以及利用宽束算法进行剂量计算在此系统中的实现。通过人体仿真体模实验证实由该治疗计划系统给出的靶区计划剂量与实测剂量的偏差在5%之内。最后讨论了设计较为完备的重离子治疗计划系统仍需解决的问题。