984 resultados para bidimensional electrophoresis
Resumo:
beta-Adrenoceptors(beta-ARs) play a critical role in regulating cardiac functions under both physiological and pathological conditions. To further explore the mechanisms through which beta-ARs perform its actions, proteomic approaches were adopted to study the global protein patterns in cultured neonatal rat cardiomyocytes exposed to isoproterenol (ISO). A modified method, "Mirror Images in One Gel", was used to improve the reproducibility and resolution power of two-dimensional electrophoresis. A 2-DE map with a good reproducibility was obtained in which 1281 70 spots were detected and about 1191 +/- 54 spots were matched, with an average matching rate of 92.9%. Nine proteins with significant changes were identified by using peptide mass fingerprinting(PMF) data obtained via MALDI-MS.
Resumo:
Capillary electrophoresis (CE) with amperometric detection (AD) has been widely used in various fields of analytical science, especially in the pharmaceutical industry recently due to its high separation efficiency and low detection limit. The determination of active ingredients in Chinese herb medicines by CE-AD is of great importance in developing the researches on pharmacology of herbs, quantitative analysis and quality control. Analyses of the effective components in Chinese herb medicines and compound Chinese herb medicine by CE-AD are reviewed in this paper. In contrast with other analysis methods, the advantage of CE-AD is discussed. The development in analyses of traditional Chinese medicine (TCM) by CE-AD in future is mentioned.
Evaluation and application of micro-sampling system for inductively coupled plasma mass spectrometry
Resumo:
Two Meinhard microconcentric nebulizers, model AR30-07-FM02 and AR 30-07-FM005, were employed as a self-installed micro-sampling system for inductively coupled plasma-mass spectrometry (ICP-MS). The FM02 nebulizer at 22 muL/min of solution uptake rate gave the relative standard deviations of 7.6%, 3.0%, 2.7%, 1.8% for determinations (n = 10) of 20 mug/L Be, Co, In and Bi, respectively, and the detection limits (3s) of 0.14, 0.10, 0.02 and 0.01 mug/L for Be, Co In and Bi, respectively. The mass intensity of In-115 obtained by this micro-sampling system was 60% of that by conventional pneumatic nebulizer system at 1.3 mL/min. The analytical results for La, Ce, Pr and Nd in 20 muL Wistar rat amniotic fluid obtained by the present micro-sampling system were precisely in good agreement with those obtained using conventional pneumatic nebulization system.
Resumo:
Sodium dodecyl sulfate(SDS) is a powerful solubilizing detergent which is often used during the separation of highly complex protein mixtures by one- or two-dimensional (2D) gel electrophoresis. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a widely used technique for mass spectrometric analysis of some protein molecules compared to other techniques. But the presence of SDS or some salts usually leads to signal deterioration when using MALDI-MS. A method for using nitrocellulose membrane as the solid-phase carrier combined with n-octyl-beta-D-glucopyranoside in the matrix highly enhances the sensitivity of the molecular mass determination of lysozyme. This technique has the advantage that the signal-to-noise of the molecular weight profile is improved compared with the mass spectrum and the profile is relatively easy to interpret.
Resumo:
A simple and sensitive flow injection method is presented for the determination of histidine based on its enhancement of electrogenerated chemiluminescence (ECL) of luminol. After optimization of the experimental parameters, the working range for histidine was in 1.0 x 10(-6) to 1.0 x 10(-3) mol/L with a detection limit (S/N = 3) of 0.56 mumol/L. The relative standard deviation was 1.6% for 11 measurements of 5 x 10(-5) mol/L histidine solution. The proposed method has been successfully applied to the determination of histidine in real pharmaceutical preparation.
Resumo:
In this paper, the fixing and stretching effect of Ni(phen)(2+)(3) with different concentrations on DNA had been studied by Tapping mode AFM. Under an ambient condition, the high-resolution DNA images were obtained, the average height, width and length of well spread DNA molecules were measured. The results showed that because of the variations of ionic concentration, the density and topography of DNA molecules on substrate had a great difference. The AFM and gel electrophoresis results also showed that, under our experimental condition, DNA molecules kept intact, Ni(phen)(2+)(3) did not catalyze the cleavage activity of EcoRI, therefore, Ni (phen)(2+)(3) would be used to make high-resolution physical mapping of DNA by AFM.
Resumo:
The L-a. a, oxidase of Agkistrodon blomhof fii ussurensis of Changbai Mountains in northeast of China has been separated by using ion-exchange and gel filtration techniques, This enzyme is composed of two subunits, the molecular weight of one subunit is about 36 000, the another is about 57 000, determined by sodium dodecyl sulfate-polyacryamide gel electrophoresis and matrix assisted laser desorption ion/time of flight mass spectrometry, The activity of L-a, a. oxidase determined using L-Leu as substrate. The optimal pH of the enzyme is 4. 5 similar to 5. 5 and 8 similar to 9. The UV-Visible absorption spectrum of L-a, a. oxidase shows the characteristics of flavor-proteins.
Resumo:
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was used to analyze two enzymes, phospholipase AZ and fibrinolytic enzyme isolated from Chinese Agkistrodon blomhoffii Ussurensis venom. Using sinapinic acid as the matrix, positive ion mass spectra of the enzymes were obtained, In addition to the dominant protein [M+H](+) ions, multimeric and multiply charged ions were also observed in the mass spectra, The higher the concentration of the enzymes, the more multiply charged polymer and multimeric ions were detected, Our results indicate that MALDI-TOFMS can provide a rapid and accurate method for molecular weight determination of snake venom enzymes, Mass accuracies of 0.1 and 0.3 % were achieved by analysis of highly dialyzed phospholipase A2 and fibrinolytic enzyme, and these results are much better than those obtained using sodium dodecyl sulfate-palyacrylamide gel electrophoresis. MALDI-TOFMS thus provides a reliable method to determine the purity and molecular weight of these enzymes, which are of potential use as therapeutants, Copyright (C) 1999 John Wiley & Sons, Ltd.
Resumo:
The thiol group of glutathione (GSH) was protected by 2,4-dinitrochlorobenzene (DNCB), the product S-substituted dinitrophenyl GSH(GSH-S-DNP) was alcoholized to obtain haptenes 4 and 5 respectively. As haptenes, the two GSH derivatives were characterized by means of H-1 NMR, MALDI-TOF-MS and IR, followed by individually coupling with bovine serum albumin (BSA) via glutaraldehyde. BSB-Hp4 and BSA-Hp5 were purified by Sephadex G-25 gel filtration chromatography. For each conjugate, the average haptene-BSA ratio was 12 : 1. The electrophoresis analysis showed that the average molecular weight of each conjugate was 76 500. The CD spectrum indicated that the conjugates had more a-helix content than BSA did.
Resumo:
A monomer, 2,3,6,7,10,11-hexakispentyloxy triphenylene (HPT) possesses a triphenylene core as a discotic mesogen. Polymers containing this discotic mesogen have been studied using wide-angle X-ray and electron diffraction. HPT is known to show a discotic liquid crystal phase, noted as D-ho (h for hexagonal bidimensional lattice, o for ordered molecular spacing in each column). In this paper, however, HPT Liquid crystalline phases, heated up from the crystalline state and cooled down from the isotropic state, were characterized in the diameter dimensions. In addition. the diameters of the columns are close to a parameter of two separate crystals. A core orientation was, therefore, proposed in the mesophase obtained by heating the crystalline. In order to distinguish these differences, the D-ho phase was divided to include the D-hcd and D-hco phases. Molecular modeling was performed to help our understanding of the orientation. The D-hcd and D-hco phases were used to characterize the phases of the discotic polymeric analogs by comparing their column diameters to those of the monomers. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.
Resumo:
A procedure is described for the preparation of a tubular electrode by chemical deposition of platinum at the end of a fused-silica capillary. The properties of the electrode were tested under liquid chromatographic conditions, demonstrating that both the static and the dynamic behaviour of the detection system satisfy the requirements of capillary chromatographic separations and compare well with a wall-jet amperometric system and with UV photometric detection. The detection system described is easy to prepare and does not require any time-consuming positioning of the electrode system as it is integrated into the separation part of the apparatus. (C) 1998 Elsevier Science B.V.
Resumo:
The thiol group of glutathione (GSH) reacts specifically with 2,4-di-ni-trochlorobenzene to give S-substituted dinitrophenyl glutathione (GSH-S-DNP); two carboxyl groups of GSH-S-DNP were further esterified by n-butanol to produce the hapten, multisubstrate analog GSH-S-DNP Butyl Ester (GSH-S-DNP BE). The primary structure of the hapten was characterized by the free. amino group analysis, H-1 NMR, IR determinations and the elemental analysis. The hapten was then conjugated to bovine serum albumin (BSA) in the presence of glutaraldehyde. The reaction mixture was purified by Ultrogel AcA54 colum chromatography to give the antigen. On an average, 25 haptens were bound to each BSA molecule. Electrophoresis analysis showed that the average molecular weight of the antigen was 87 KD. CD spectrum showed that the a-helix content of the antigen increased.
Resumo:
高效毛细管电泳(High performance capillary electrophoresis缩写HPCE)是一种高效、快速分离复杂混合物的强有力工具.毛细管电泳电化学检测(Capillary electrophoresiselectrochemistry缩写CEEC)在HPCE中是一个极有前途的研究领域.安培检测由于灵敏度高,死体积小,成本低,而受到极大关注.把化学修饰电极(Chemically modified electrode缩写CME)用于CEEC的报道很少.本文介绍了一种新颖的方法将铂修饰到碳纤维电极上,并用于CEEC中检测肼.肼是一类比较难氧化的化合物,在普通固体电极上过电位很高,不适于电化学检测.我们做的修饰电极,对肼不仅有很好的催化活性,而且有很好的稳定性.
Resumo:
A novel device of multiple cylinder microelectrodes coupled with a parallel planar electrode was proposed. The feedback diffusion current at this device was studied using bilinear transformation of coordinates in the diffusion space, where lines of mass flux and equiconcentration are represented by orthogonal circular functions. The derived expression for the steady-state current shows that as the gap between cylindrical microelectrodes and planar electrode diminishes, greatly enhanced currents can be obtained with high signal-to-noise ratio. Other important geometrical parameters such as distance between adjacent microcylinders, cylinder radius, and number of microcylinders were also discussed in detail.
Resumo:
The glycoproteins and glycolipids from membranes of virulent strain Z and avirulent strain M of Mycoplasma hyopneumoniae have been compared. The proteins and the glycoproteins were identified by SDS-polyacrylamide gel electrophoresis and concanavalin A-biotin labeling, respectively. The membrane preparation contained approximately 34 protein bands with molecular weights between 20 KD and 100 KD. The concanavalin A-biotin system reacted with a glycoprotein of a molecular weight of approximately 28,000 from avirulent strain M and did not react with the correspondent band from virulent strain Z. The membrane glycolipids of both strains consisted of monogalactosyldiacylglycerol (MGDG) and digalactosyldiacylglycerol (DGDG), and the percentages of 16:0, 18:0, and 18:1 fatty acids comprised more than 80% of the total fatty acids of membrane glycolipids. The 18:0 fatty acid of MGDG in avirulent strain M was twofold higher than that of virulent strain Z.