934 resultados para ambulatory blood pressure monitoring
Resumo:
In 58 newborn infants a new iridium oxide sensor was evaluated for transcutaneous carbon dioxide (tcPCO2) monitoring at 42 degrees C with a prolonged fixation time of 24 hours. The correlation of tcPCO2 (y; mm Hg) v PaCO2 (x; mm Hg) for 586 paired values was: y = 4.6 + 1.45x; r = .89; syx = 6.1 mm Hg. The correlation was not influenced by the duration of fixation. The transcutaneous sensor detected hypocapnia (PaCO2 less than 35 mm Hg) in 74% and hypercapnia (PCO2 greater than 45 mm Hg) in 74% of all cases. After 24 hours, calibration shifts were less than 4 mm Hg in 90% of the measuring periods. In 86% of the infants, no skin changes were observed; in 12% of infants, there were transitional skin erythemas and in 2% a blister which disappeared without scarring. In newborn infants with normal BPs, continuous tcPCO2 monitoring at 42 degrees C can be extended for as many as 24 hours without loss of reliability or increased risk for skin burns.
Resumo:
OBJECTIVEAnalyzing the quality of sleep of hypertensive patients registered in the national registration system and monitoring of hypertensive patients.METHODSA cross-sectional study of quantitative and descriptive analyses with 280 hypertensive patients registered in the National Program of Hypertension and Diabetes of the Federal Government in the months from August to October 2011. Questionnaires were used which allowed for tracking sociodemographic data on hypertension and Pittsburgh Sleep Quality Index (PSQI).RESULTSThe prevalence of poor sleep quality among respondents (156 hypertensive patients) and high rates of using medication for sleeping (106 hypertensive patients) was observed. Other relevant data refers to the quality of sleep among hypertensive patients using sleep medication compared to those who do not use it (p≤0.01).CONCLUSIONIndividuals with high blood pressure have a negative association with sleep quality.
Resumo:
Effet d'un bolus intraveineux de phénylephrine ou d'éphedríne sur le flux sanguin cutané lors d'une anesthésie rachidienne Introduction : La phénylephrine et l'éphedrine sont des substances vaso-actives utilisées de routine pour corriger des épisodes d'hypotension artérielle induits par l'anesthésie intrarachidienne. L'influence de ces deux vasopresseurs sur le flux sanguin cutané (FSC) dans ce contexte n'a jusqu'à maintenant pas été décrite. Cette étude évalue l'effet d'une injection intraveineuse de 75 µg de phénylephrine ou de 7.5 mg d'éphedrine sur le FSC mesuré par Laser Doppler, dans les zones concernées parle bloc sympathiqué induit par l'anesthésie intrarachidienne (membres inférieurs) et dans les zones non concernées (membres supérieurs). Méthode :Après acceptation par le Comité d'Éthique, et obtention de leur accord écrit, 20 patients devant subir une intervention chirurgicale élective en décubitus dorsal sous anesthésie. intrarachidienne ont été inclus dans cette étude randomisée en double insu. Le FSC a été mesuré en continu par deux sondes fixées l'une à la cuisse (zone avec bloc sympathique) et l'autre sur l'avantbras (zone sans bloc sympathique). Les valeurs de FSC ont été enregistrées après l'anesthésie rachidienne (valeur contrôle), puis après l'injection i.v. dè phénylephrine (10 patients) ou d'éphedrine (10 patients) pour corriger une hypotension définie comme une chute de 20 mmHg de la pression artérielle systolique. Les variations de FSC exprimées en pourcentage de la valeur contrôle moyenne (+/- écart type) ont été analysées par le test t de Student. Résultats :Les données démographiques des patients et le niveau sensitif induit par l'anesthésie rachidienne sont similaires dans les deux groupes. Aux doses utilisées, seule l'éphedrine restaure la pression artérielle aux valeurs précédant l'anesthésie rachidienne. La phénylephrine augmente le FSC de l'avant-bras de 44% (+/- 79%) et de la cuisse de 34% (+/-24%), alors que l'éphedrine diminue le débit sanguin cutané de l'avant-bras de 16% (+/- 15%) et de la cuisse de 22% (+/-11%). Conclusion : L'injection intraveineuse de phénylephrine et d'éphedrine ont des effets opposés sur le flux sanguin cutané, et cette réponse n'est pas modifiée par le bloc sympathique.. Cette différence peut s'expliquer par la distribution des sous-types de récepteurs adrénergiques alpha et leur prédominance relative dans les veines et les artères de différents diamètres perfusant le tissu sous-cutané et la peau. L'éphedrine, èn raison de sa meilleure efficacité pour traiter les épisodes d'hypotension artérielle après anesthésie intrarachidienne devrait être préféré à la phénylephrine, leurs effets opposés sur le flux sanguin cutané n'étant pas pertinents en pratique clinique. SUMMARY Background: Phenylephrine or ephedrine is routinely used to correct hypotensive episodes fallowing spinal anaesthesia (SA). The influence of these two vasopressors on skin blood flow (SBF) has not yet been described. We have therefore evaluated the effects of an i.v. bolus of 75 µg phenylephrine or 7.5 mg of ephedrine on SBF measured by laser Doppler flowmetry during sympathetic blockade induced by SA. Methods: With Ethical Committee approval and written consent, 20 patients scheduled for elective procedures in supine position under SA were enrolled in this double-blind randomized study. SBF was measured continuously by two probes fixed at the thigh (area with sympathic blockade) and forearm level (area without sympathic blockade) respectively. SBF values were recorded after SA (control values) and then after a bolus administration of phenylephriné (n=10) or ephedrine (n=10) when systolic blood pressure decreased by 20 mmHg. Changes were expressed as percentage of control SBF values and analysed by Student's paired t-test. Results: Patient characteristics and dermatomal sensory levels were similar in both groups. Phenylephrine increases mean SBF at the forearm level by 44% (79%) [mean (SD)j and at the thigh by 34% (24%). Ephedrine decreases SBF at the forearm level by 16% (15%) and at the thigh by 22% (il%). Ephedrine bolus restores arterial blood pressure to pre-anaesthesia values, whereas phenylephrine does not. Conclusion: Administratión of phenylephrine and ephedrine has opposite effects on skin blood flow and sympathetic blockade does not modify this response. These findings could be explained by the distribution of the alpha-adrenoréceptor subtypes and their relative predominance among veins and arteries of different size perfusing the subcutaneous tissue and the skin. Ephedrine, due to its better efficacy to correct hypotensive episodes following SA, should be preferred, to phenylephrine, their opposite effects on SBF being not relevant for clinical practice.
Resumo:
Euglycemic hyperinsulinemia stimulates both sympathetic nerve activity and blood flow to skeletal muscle, but the mechanism is unknown. Possible mechanisms that may stimulate muscle blood flow include neural, humoral, or metabolic effects of insulin. To determine whether such insulin-induced vasodilation is modulated by stimulation of adrenergic or cholinergic mechanisms, we obtained, in eight healthy lean subjects, plethysmographic measurements of calf blood flow during 3 h of hyperinsulinemic (1 mU.kg-1.min-1) euglycemic clamp performed alone or during concomitant beta-adrenergic (propranolol infusion), cholinergic (atropine infusion), or alpha-adrenergic (prazosin administration) blockade. Euglycemic hyperinsulinemia alone increased calf blood flow by 38 +/- 10% (means +/- SE) and decreased vascular resistance by 27 +/- 4% (P < 0.01). The principal new observation is that these insulin-induced vasodilatory responses were not attenuated by concomitant propranolol or atropine infusion, nor were they potentiated by prazosin administration. In conclusion, these findings provide evidence that during euglycemic hyperinsulinemia in lean healthy humans stimulation of muscle blood flow is not mediated primarily by beta-adrenergic or cholinergic mechanisms. Furthermore, alpha-adrenergic mechanisms do not markedly limit insulin-induced stimulation of muscle blood flow.
Low-pressure environment and remodelling of the forearm vein in Brescia-Cimino haemodialysis access.
Resumo:
BACKGROUND: The aim of the study was to determine which, and to what extent, haemodynamic parameters contribute to the remodelling of the venous limb of the Brescia-Cimino haemodialysis access. METHODS: The dimensions of the radial artery and the venous limb of the haemodialysis access were measured by an echo-tracking technique. In six ESRD patients undergoing primary arteriovenous fistula (AVF) formation, vessel diameter, wall thickness, blood pressure and blood flow were measured after the operation, and at 1 and 3 months follow-up. The contralateral forearm vessels in their native position served as baseline values for comparison. RESULTS: The diameter of the proximal antecubital vein progressively increased over the study period without reaching significant differences (4430, 5041 and 6620 microm at weeks 1, 4 and 12 respectively), whereas the intima-media thickness remained unchanged. The venous dilatation was associated with a reduction of the mean shear stress that culminated after the operation and progressively returned to normal venous values at 3 months (24.5 vs 10.4 dyne/cm(2), P<0.043). Thus the venous limb of the AVF undergoes eccentric hypertrophy as demonstrated by the increase in wall cross-sectional area (4.42 vs 6.32 mm(2) at week 1 vs week 12, P<0.028). At the time of the operation, the blood pressure in the AVF was 151+/-14/92.4+/-11 mmHg vs 49+/-19/24.5+/-6 mmHg (means+/-SEM) for the radial artery and the venous limb of the vascular access, respectively. One year after the operation the blood pressure in the venous limb had not changed: 42+/-14/25.3+/-7 mmHg (means+/-SEM). Under these conditions, the systolo-diastolic diameter changes observed in the radial artery and the antecubital vein were within a similar range at all time points: 56+/-17 vs 90+/-26 microm (means+/-SEM) at week 12. CONCLUSIONS: The increased circumferential stress resulting from the flow-mediated dilatation rather than the elevation of blood pressure appears to represent the main contributing factor to the eccentric hypertrophy of the venous limb of Brescia-Cimino haemodialysis access.
Resumo:
OBJECTIVE: Although intracranial hypertension is one of the important prognostic factors after head injury, increased intracranial pressure (ICP) may also be observed in patients with favourable outcome. We have studied whether the value of ICP monitoring can be augmented by indices describing cerebrovascular pressure-reactivity and pressure-volume compensatory reserve derived from ICP and arterial blood pressure (ABP) waveforms. METHOD: 96 patients with intracranial hypertension were studied retrospectively: 57 with fatal outcome and 39 with favourable outcome. ABP and ICP waveforms were recorded. Indices of cerebrovascular reactivity (PRx) and cerebrospinal compensatory reserve (RAP) were calculated as moving correlation coefficients between slow waves of ABP and ICP, and between slow waves of ICP pulse amplitude and mean ICP, respectively. The magnitude of 'slow waves' was derived using ICP low-pass spectral filtration. RESULTS: The most significant difference was found in the magnitude of slow waves that was persistently higher in patients with a favourable outcome (p<0.00004). In patients who died ICP was significantly higher (p<0.0001) and cerebrovascular pressure-reactivity (described by PRx) was compromised (p<0.024). In the same patients, pressure-volume compensatory reserve showed a gradual deterioration over time with a sudden drop of RAP when ICP started to rise, suggesting an overlapping disruption of the vasomotor response. CONCLUSION: Indices derived from ICP waveform analysis can be helpful for the interpretation of progressive intracranial hypertension in patients after brain trauma.
Resumo:
Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.
Resumo:
Background and objective: Optimal care of diabetic patients (DPs) decreases the risk of complications. Close blood glucose monitoring can improve patient outcomes and shorten hospital stay. The objective of this pilot study was to evaluate the treatment of hospitalized DPs according to the current standards, including their diabetic treatment and drugs to prevent diabetes related complications [=guardian drugs: angiotensin converting enzyme inhibitors (ACEI) or Angiotensin II Receptor Blockers (ARB), antiplatelet drugs, statins]. Guidelines of the American Diabetes Association (ADA) [1] were used as reference as they were the most recent and exhaustive for hospital care. Design: Observational pilot study: analysis of the medical records of all DPs seen by the clinical pharmacists during medical rounds in different hospital units. An assessment was made by assigning points for fulfilling the different criteria according to ADA and then by dividing the total by the maximum achievable points (scale 0-1; 1 = all criteria fulfilled). Setting: Different Internal Medicine and Geriatric Units of the (multi-site) Ho^pital du Valais. Main outcome measures: - Completeness of diabetes-related information: type of diabetes, medical history, weight, albuminuria status, renal function, blood pressure, (recent) lipid profile. - Management of blood glucose: Hb1Ac, glycemic control, plan for treating hyper-/hypoglycaemia. - Presence of guardian drugs if indicated. Results: Medical records of 42 patients in 10 different units were analysed (18 women, 24 men, mean age 75.4 ± 11 years). 41 had type 2 diabetes. - Completeness of diabetes-related information: 0.8 ± 0.1. Information often missing: insulin-dependence (43%) and lipid profile (86%). - Management of blood glucose: 0.5 ± 0.2. 15 patients had suboptimal glycemic balance (target glycaemia 7.2-11.2 mmol/ l, with values[11.2 or\3.8 mmol/l, or Hb1Ac[7%), 10 patients had a deregulated balance (more than 10 values[11.2 mmol/l or \3.8 mmol/l and even values[15 mmol/l). - Presence of guardian drugs if indicated: ACEI/ARB: 19 of 23 patients (82.6%), statin: 16 of 40 patients (40%), antiplatelet drug: 16 of 39 patients (41%). Conclusions: Blood glucose control was insufficient in many DPs and prescription of statins and antiplatelet drugs was often missing. If confirmed by a larger study, these two points need to be optimised. As it is not always possible and appropriate to make those changes during hospital stay, a further project should assess and optimise diabetes care across both inpatient and outpatient settings.
Resumo:
A new high-precision ultrasonic device was developed to determine noninvasively arterial compliance as a function of blood pressure. Because of the nonlinear elastic properties of arterial walls, measurements of compliance can be appropriately compared only if obtained over a range of pressures. This apparatus was used to evaluate in a double-blind, parallel fashion the effect of three different antihypertensive drugs and of a placebo on radial artery compliance. Thirty-two normotensive volunteers were randomly allocated to an 8-day, once-a-day oral treatment with either a placebo, 100 mg atenolol, 20 mg nitrendipine, or 20 mg lisinopril. Blood pressure, heart rate, radial artery diameter, and arterial compliance were measured immediately before as well as 6 hours after dosing on the first and last days of the study. On the eighth day of administration, within 6 hours after dosing, lisinopril induced an acute increase in radial artery diameter, from 2.99 +/- 0.06 to 3.28 +/- 0.09 mm (mean +/- SEM, p less than 0.01). The compliance-pressure curve was shifted upward on day 1 (p less than 0.01) as well as on day 8 (p less than 0.05). None of the other drugs induced any significant modification of these parameters. Arterial compliance has a strong nonlinear dependency on intra-arterial pressure and therefore has to be defined as a function of pressure. Antihypertensive drugs acting by different mechanisms may have different effects on the mechanical properties of large arteries.
Resumo:
Severe sepsis and septic shock are systemic manifestations of the host response to infection. Mortality remains high despite advances in pathophysiological knowledge. Hemodynamic and respiratory management is largely supportive, while early antibiotics administration and source of infection's control are crucial for patient outcome. We review the principles guiding the initial management of these patients in emergency situation.
Resumo:
This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.
Resumo:
Background and Purpose-Demographic changes will result in a rapid increase of patients age >= 90 years (nonagenarians), but little is known about outcomes in these patients after intravenous thrombolysis (IVT) for acute ischemic stroke. We aimed to assess safety and functional outcome in nonagenarians treated with IVT and to compare the outcomes with those of patients age 80 to 89 years (octogenarians).Methods-We analyzed prospectively collected data of 284 consecutive stroke patients age >= 80 years treated with IVT in 7 Swiss stroke units. Presenting characteristics, favorable outcome (modified Rankin scale [mRS] 0 or 1), mortality at 3 months, and symptomatic intracranial hemorrhage (SICH) using the National Institute of Neurological Disorders and Stroke (NINDS) and Safe Implementation of Thrombolysis in Stroke-Monitoring Study (SITS-MOST) criteria were compared between nonagenarians and octogenarians.Results-As compared with octogenarians (n=238; mean age, 83 years), nonagenarians (n=46; mean age, 92 years) were more often women (70% versus 54%; P=0.046) and had lower systolic blood pressure (161 mm Hg versus 172 mm Hg; P=0.035). Patients age >= 90 years less often had a favorable outcome and had a higher incidence of mortality than did patients age 80 to 89 years (14.3% versus 30.2%; P=0.034; and 45.2% versus 22.1%; P=0.002; respectively), while more nonagenarians than octogenarians experienced a SICH (SICHNINDS, 13.3% versus 5.9%; P=0.106; SICHSITS-MOST, 13.3% versus 4.7%; P=0.037). Multivariate adjustment identified age >= 90 years as an independent predictor of mortality (P=0.017).Conclusions-Our study suggests less favorable outcomes in nonagenarians as compared with octogenarians after IVT for ischemic stroke, and it demands a careful selection for treatment, unless randomized controlled trials yield more evidence for IVT in very old stroke patients. (Stroke. 2011; 42: 1967-1970.)