927 resultados para Tip


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the analysis of instrumented indentation data, it is common practice to incorporate the combined moduli of the indenter (E-i) and the specimen (E) in the so-called reduced modulus (E-r) to account for indenter deformation. Although indenter systems with rigid or elastic tips are considered as equivalent if E-r is the same, the validity of this practice has been questioned over the years. The present work uses systematic finite element simulations to examine the role of the elastic deformation of the indenter tip in instrumented indentation measurements and the validity of the concept of the reduced modulus in conical and pyramidal (Berkovich) indentations. It is found that the apical angle increases as a result of the indenter deformation, which influences in the analysis of the results. Based upon the inaccuracies introduced by the reduced modulus approximation in the analysis of the unloading segment of instrumented indentation applied load (P)-penetration depth (delta) curves, a detailed examination is then conducted on the role of indenter deformation upon the dimensionless functions describing the loading stages of such curves. Consequences of the present results in the extraction of the uniaxial stress-strain characteristics of the indented material through such dimensional analyses are finally illustrated. It is found that large overestimations in the assessment of the strain hardening behavior result by neglecting tip compliance. Guidelines are given in the paper to reduce such overestimations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During copulation, spermatophores produced by male coleoid cephalopods undergo the spermatophoric reaction, a complex process of evagination that culminates in the attachment of the spermatangium (everted spermatophore containing the sperm mass) on the female's body. To better understand this complicated phenomenon, the present study investigated the functional morphology of the spermatophore of the squid Doryteuthis plei applying in vitro analysis of the reaction, as well as light and electron microscopy investigation of spermatangia obtained either in vitro, or naturally attached on females. Hitherto unnoticed functional features of the loliginid spermatophore require a reappraisal of some important processes involved in the spermatophoric reaction. The most striking findings concern the attachment mechanism, which is not carried out solely by cement adhesive material, as previously believed, but rather by an autonomous, complex process performed by multiple structures during the spermatophoric reaction. During evagination, the ejaculatory apparatus provides anchorage on the targeted tissue, presumably due to the minute stellate particles present in the exposed spiral filament. Consequently, the ejaculatory apparatus maintains the attachment of the tip of the evaginating spermatophore until the cement body is extruded. Subsequently, the cement body passes through a complex structural rearrangement, which leads to the injection of both its viscid contents and pointed oral region onto the targeted tissue. The inner membrane at the oral region of the cement body contains numerous stellate particles attached at its inner side; eversion of this membrane exposes these sharp structures, which presumably adhere to the tissue and augment attachment. Several naturally attached spermatangia were found with their bases implanted at the deposition sites, and the possible mechanisms of perforation are discussed based on present evidence. The function of the complex squid spermatophore and its spermatophoric reaction is revisited in light of these findings. J. Morphol. 2012. (C) 2011 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents an optimum user-steered boundary tracking approach for image segmentation, which simulates the behavior of water flowing through a riverbed. The riverbed approach was devised using the image foresting transform with a never-exploited connectivity function. We analyze its properties in the derived image graphs and discuss its theoretical relation with other popular methods such as live wire and graph cuts. Several experiments show that riverbed can significantly reduce the number of user interactions (anchor points), as compared to live wire for objects with complex shapes. This paper also includes a discussion about how to combine different methods in order to take advantage of their complementary strengths.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to determine clinical parameters for the use of Er,Cr:YSGG laser in the treatment of dentine hypersensitivity. Two antagonist areas were determined as control and experimental areas for irradiation in 90 premolar roots. Each surface was conditioned with 24% EDTA (sub-group 1) and 35% phosphoric acid (sub-group 2) and irradiated with the following settings: 1) Er:YAG, 60 mJ, 2 Hz, defocused; groups 2 to 9: irradiation with Er,Cr:YSGG laser, 20 Hz, Z6 tip, 0% of air and water: 2) Er,Cr:YSGG 0.25 W; 3) 0.5 W; 4) 0.75 W; 5) 1.0 W; 6) 1.25 W, 7) 1.50 W, 8) 2 W; 9) 2 W. After irradiation, samples were immersed in methylene blue solution and included in epoxy resin to obtain longitudinal cuts. The images were digitalized and analyzed by computer software. Although the samples irradiated with Er:YAG laser showed less microleakage, sub-group 1 showed differences between the groups, differing statistically from groups 3, 6, and 9. The results of sub-group 2 showed that the mean values of Er:YAG samples showed a negative trend, however, no differences were detected between the groups. For scanning electron microscopy analysis, dentine squares were obtained and prepared to evaluate the superficial morphology. Partial closure of dentinal tubules was observed after irradiation with Er:YAG and Er,Cr:YSGG laser in the 0.25 and 0.50 W protocols. As the energy densities rose, open dentinal tubules, carbonization and cracks were observed. It can be concluded that none of the parameters were capable of eliminating microleakage, however, clinical studies with Er:YAG and Er,Cr:YSGG lasers should be conducted with the lowest protocols in order to determine the most satisfactory setting for dentine hypersensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Male coleoid cephalopods produce spermatophores that can attach autonomously on the female's body during a complex process of evagination called the spermatophoric reaction, during which the ejaculatory apparatus and spiral filament of the spermatophore are everted and exposed to the external milieu. In some deepwater cephalopods, the reaction leads to the intradermal implantation of the spermatophore, a hitherto enigmatic phenomenon. The present study builds upon several lines of evidence to propose that spermatophore implantation is probably achieved through the combination of (1) an evaginating-tube mechanism performed by the everting ejaculatory apparatus and (2) the anchorage provided by the spiral filament's stellate particles. The proposed theoretical model assumes that, as it is exposed to the external milieu, each whorl of the spiral filament anchors to the surrounding tissue by means of its sharp stellate particles. As the ejaculatory apparatus tip continues evaginating, it grows in diameter and stretches lengthwise, enlarging the diameter of the whorl and propelling it, consequently tearing and pushing the anchored tissue outward and backward, and opening space for the next whorl to attach. After the ejaculatory apparatus has been everted and has perforated tissue, the cement body is extruded, possibly aiding in final attachment, and the sperm mass comes to lie inside the female tissue, encompassed by the everted ejaculatory apparatus tube. It is proposed that this unique, efficient spermatophore attachment mechanism possibly evolved in intimate relationship with the adoption of an active mode of life by coleoids. The possible roles of predation pressure and sperm competition in the evolution of this mechanism are also discussed. (c) 2012 The Linnean Society of London, Biological Journal of the Linnean Society, 2012, 105, 711726.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The fiber dissection technique provides unique 3-dimensional anatomic knowledge of the white matter. OBJECTIVE: To examine the optic radiation anatomy and its important relationship with the temporal stem and to discuss its findings in relation to the approaches to temporal lobe lesions. METHODS: We studied 40 cerebral hemispheres of 20 brains that had been fixed in formalin solution for 40 days. After removal of the arachnoid membrane, the hemispheres were frozen, and the Klingler technique was used for dissection under magnification. Stereoscopic 3-dimensional images of the dissection were obtained for illustration. RESULTS: The optic radiations are located deep within the superior and middle temporal gyri, always above the inferior temporal sulcus. The mean distance between the cortical surface and the lateral edge of the optic radiation was 21 mm. Its fibers are divided into 3 bundles after their origin. The mean distance between the anterior tip of the temporal horn and the Meyer loop was 4.5 mm, between the temporal pole and the anterior border of the Meyer loop was 28.4 mm, and between the limen insulae and the Meyer loop was 10.7 mm. The mean distance between the lateral geniculate body and the lateral margin of the central bundle of the optic radiation was 17.4 mm. CONCLUSION: The white matter fiber dissection reveals the tridimensional intrinsic architecture of the brain, and its knowledge regarding the temporal lobe is particularly important for the neurosurgeon, mostly because of the complexity of the optic radiation and related fibers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: In the presence of turbinate dysfunction, an inferior turbinectomy for persistent hypertrophy of bone and/or mucosa may be performed. We sought to explore anatomic feasibility of a transoral turbinectomy. Methods: After transoral inferior turbinectomy in 12 cadavers, average distances from the external nasal valve to inferior turbinate and from pyriform aperture to inferior turbinate were compared. Average "area of access" was calculated. Preoperative and postoperative nasal length, tip projection, and alar-base width were also compared. Results: Average distance from external nasal valve to inferior turbinate was 32.4 mm. Average distance from aperture to inferior turbinate was 2.4 mm (P < 0.0001). Average "areas of access" to nasal vault through the external nasal valve and mouth were 183.9 mm(2) and 243.6 mm(2) (P = 0.07), respectively. Conclusions: The transoral approach provides a larger "area of access" to the turbinate, a statistically significant reduction of distance to target, no postoperative changes in nasal soft tissue, and easier instrumentation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lebiasina marilynae n. sp., L. melanoguttata n. sp., and L. minuta n. sp. are described from the headwaters of the rio Curua in Serra do Cachimbo, Para, Brazil, and represent the only members of the Lebiasininae in the Brazilian Shied, so far. A close relationship among these species is proposed based on: I) the presence of a pair of foramina through which the rain us palatinus of the facial nerve passes, a modification unique in Lebiasinidae and apparently in the Characiformes, 2) the enlargement of the extrascapular bone, 3) the absence of the secondary stripe, and 4) the nearly equal length of caudal-fin lobes. Lebiasina marilynae additionally differs from all congeners in having the primary stripe extending from the tip of the snout to the distal border of the caudal-fin peduncle, the possession of two series of dark blotches parallel to the primary stripe, and a rounded dorsal surface of the mesethmoid. Lebiasina melanoguttata and Lebiasina minuta additionally differ from all congeners in the absence of the primary stripe and the caudal blotch, and the presence of three longitudinal series of dark blotches at the base of the scales of series 3-5. Lebiasina melanoguttata differs from Lebiasina minuta in the absence of a dark blotch at the base of the median rays of the dorsal fin, second infrapharyngobranchial bearing conical teeth, the reddish overall coloration of the eye and fins, and the dark blotches never coalescing (vs. dark dorsal-fin blotch present; the second infrapharyngobranchial being edentulous; dark, olive green eyes, and the yellowish overall color of body and fins; and the dark blotches of longitudinal series 3 and 4 coalescing where scales of adjacent longitudinal series overlap). The occurrence of species of the Lebiasininae on the Brazilian Shield is discussed, and the distribution pattern of the species described herein is compared to that of other endemic species of the Serra do Cachimbo, a highly biodiverse area isolated from the rest of the Amazon basin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Describe a modified technique to increase nostril cross-sectional area using rib and septal cartilage graft over alar nasal cartilages. METHODS: A modified surgical technique was used to obtain, carve and insert cartilage grafts over alar nasal cartilages. This study used standardized pictures and measured 90 cadaveric nostril cross-sectional area using Autocad (c); 30 were taken before any procedure and 60 were taken after grafts over lateral crura (30 using costal cartilage and 30 using septal cartilage). Statistical analysis were assessed using a model for repeated measures and ANOVA (Analysis of Variance) for the variable "area". RESULTS: There's statistical evidence that rib cartilage graft is more effective than septal cartilage graft. The mean area after the insertion of septal cartilage graft is smaller than the mean area under rib graft treatment (no confidence interval for mean difference contains the zero value and all P-values are below the significance level of 5%). CONCLUSIONS: The technique presented is applicable to increase nostril cross section area in cadavers. This modified technique revealed to enhance more nostril cross section area with costal cartilage graft over lateral crura rather than by septal graft.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To determine the incidence of Piry virus contamination among surgical instruments used with disposable accessories for phacoemulsification during sequential surgeries. Methods: An experimental model was created with 4 pigs' eyes that were contaminated with Piry virus and 4 pigs' eyes that were not contaminated. Phacoemulsification was performed on the eyes, alternating between the contaminated and non-contaminated eyes. From one surgery to another, the operating fields, gloves, scalpel, tweezers, needles, syringes, tips and bag collector from the phacoemulsification machine were exchanged; only the hand piece and the irrigation and aspiration systems were maintained. Results: In the collector bag, three samples from the contaminated eyes (3/4) were positive, and two samples from the non-contaminated (2/4) eyes were also positive; at the tip, one sample from the contaminated eyes (1/4) and two samples of the noncontaminated eyes (2/4) yielded positive results. In the irrigation system, one sample from a non-contaminated eye (1/4) was positive, and in the aspiration system, two samples from contaminated eyes (2/4) and two samples from non-contaminated eyes (2/4) were positive. In the gloves, the samples were positive in two samples from the non-contaminated eyes (2/4) and in two samples from the contaminated eyes (2/4). In the scalpel samples, three contaminated eyes (3/4) and none of the non-contaminated eyes (0/4) were positive; finally, two samples from the anterior chambers of the non-contaminated eyes gathered after surgery were positive. Conclusions: In two non-contaminated eyes, the presence of genetic material was detected after phacoemulsification surgery, demonstrating that the transmission of the genetic material of the Piry virus occurred at some point during the surgery on these non-contaminated eyes when the hand piece and irrigation and aspiration systems were reused between surgeries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Nuss procedure requires the creation of a substernal tunnel for bar positioning. This is a manoeuvre that can be dangerous, and cardiac perforation has occurred in a few cases. Our purpose was to describe two technical modifications that enable the prevention of these fatal complications. A series of 25 patients with pectus excavatum were treated with a modification of the Nuss procedure that included the entrance in the left haemithorax first, and the use of the retractor to lift the sternum, with the consequent lowering displacement of the heart. These modified techniques have certain advantages: (i) the narrow anterior mediastinum between the sternum and the pericardial sac is expanded by pulling up the sternum; (ii) the thoracoscopic visualization of the tip of the introducer during tunnel creation is improved; (iii) the rubbing of the introducer against the pericardium is minimized; (iv) the exit path of the introducer can be guided by the surgeon's finger and (v) haemostasis and integrity of the pericardial sac can be more easily confirmed. We observed that with these manoeuvres, the risk of pericardial sac and cardiac injury can be markedly reduced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the mid 1980s the Atomic Force Microscope is one the most powerful tools to perform surface investigation, and since 1995 Non-Contact AFM achieved true atomic resolution. The Frequency-Modulated Atomic Force Microscope (FM-AFM) operates in the dynamic mode, which means that the control system of the FM-AFM must force the micro-cantilever to oscillate with constant amplitude and frequency. However, tip-sample interaction forces cause modulations in the microcantilever motion. A Phase-Locked loop (PLL) is used to demodulate the tip-sample interaction forces from the microcantilever motion. The demodulated signal is used as the feedback signal to the control system, and to generate both topographic and dissipation images. As a consequence, a proper design of the PLL is vital to the FM-AFM performance. In this work, using bifurcation analysis, the lock-in range of the PLL is determined as a function of the frequency shift (Q) of the microcantilever and of the other design parameters, providing a technique to properly design the PLL in the FM-AFM system. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Paraehlersia San Martin, 2003 is reported for the first time for the Atlantic coast off South America based on specimens collected off Brazil and Argentina. The specimens belong to two new species, which are herein described. Paraehlersia longichaetosa sp. nov., is characterized by having spiniger-like chaetae with long blades, up to 120 mu m in length, bidentate anterior falcigers, with relatively coarse subdistal tooth, bidentate dorsal simple chaetae, with teeth about same size, and subdistally irregularly inflated aciculae, apparently hollow, with acute tip. Paraehlersia martapolae sp. nov., has spiniger-like chaetae with shorter blades, up to 82 mu m in length, bidentate falcigers, with thin subdistal tooth, distally irregularly rounded dorsal simple chaetae, and aciculae subdistally bent at almost right angle, sometimes with apparently flattened top. These new species are compared to their most similar congeners. Additionally, a table summarizing relevant morphological traits of all currently known species of Paraehlersia is included.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statement of problem. Matrices of unsplinted attachment systems are generally reported to be the weak component of implant overdentures, often requiring frequent maintenance. Clinical wear results in reduced retention of the prosthesis, requiring activation or renewal of the matrix to restore the initial level of retention. Purpose. The purpose of this retrospective study was to measure the wear of the matrix of a ball attachment after various periods of clinical wear. Material and methods. Seventy specimens of 3 groups of matrices of ball attachments that had been in use for mean periods of 12.3 months (1Y group, n=26), 39.0 months (3Y group, n=28) and 95.6 months (8Y group, n=16) were retrieved from 35 patients (2 specimens per patient) and measured on a coordinate measuring machine equipped with a touch trigger probe. Ten unused matrices were used as controls (CTRL group). The external and internal matrix diameters and deviations from circularity were measured. For the various time periods, the decreases in matrix thickness were calculated and compared with controls. Kruskal-Wallis 1-way ANOVA by ranks, followed by the Mann-Whitney post hoc tests, were conducted to test for differences in median values among groups (alpha=.05). Results. For the internal upper diameter of the matrices tested, the Kruskal-Wallis and Mann-Whitney tests revealed significant differences for the 3 groups compared to the controls. For group 1Y, a significant difference (P<.001) of the internal upper diameter was found compared to the CTRL group. Compared to the controls, the nonparametric analyses for groups 3Y and 8Y showed significant differences for the internal upper diameter (P<.001) and deviations from circularity (P<.001). For groups 1Y, 3Y and 8Y, matrix thickness losses were 07, 47 and 70 pm, respectively. Conclusions. Within the limitations of this study, it was observed that one year of clinical wear had limited effect on the ball attachment matrices. Three to 8 years of clinical use resulted in a significant decrease of matrix thickness, especially at the tip of the retentive lamellae. (J Prosthet Dent 2012;107:191-198)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length. Material and Methods: Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex locator indicated the APEX measurement in the screen. From this measurement, 1 mm was subtracted for positioning the file. The radiographic measurements were made using a digital sensor (Digora 1.51) or conventional type-E films, size 2, following the paralleling technique, to determine the distance of the file tip and the radiographic apex. Results: The Student "t" test indicated mean distances of 1.11 mm to conventional and 1.20 mm for the digital method and indicated a significant statistical difference (p<0.05). Conclusions: The conventional radiographic method was found to be superior to the digital one in determining the working length of the root canal.