In vitro effects of Er,Cr:YSGG laser on dentine hypersensitivity. Dentine permeability and scanning electron microscopy analysis


Autoria(s): Aranha, Ana Cecilia Corrêa; Eduardo, Carlos de Paula
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

30/10/2013

30/10/2013

2012

Resumo

The aim of the present study was to determine clinical parameters for the use of Er,Cr:YSGG laser in the treatment of dentine hypersensitivity. Two antagonist areas were determined as control and experimental areas for irradiation in 90 premolar roots. Each surface was conditioned with 24% EDTA (sub-group 1) and 35% phosphoric acid (sub-group 2) and irradiated with the following settings: 1) Er:YAG, 60 mJ, 2 Hz, defocused; groups 2 to 9: irradiation with Er,Cr:YSGG laser, 20 Hz, Z6 tip, 0% of air and water: 2) Er,Cr:YSGG 0.25 W; 3) 0.5 W; 4) 0.75 W; 5) 1.0 W; 6) 1.25 W, 7) 1.50 W, 8) 2 W; 9) 2 W. After irradiation, samples were immersed in methylene blue solution and included in epoxy resin to obtain longitudinal cuts. The images were digitalized and analyzed by computer software. Although the samples irradiated with Er:YAG laser showed less microleakage, sub-group 1 showed differences between the groups, differing statistically from groups 3, 6, and 9. The results of sub-group 2 showed that the mean values of Er:YAG samples showed a negative trend, however, no differences were detected between the groups. For scanning electron microscopy analysis, dentine squares were obtained and prepared to evaluate the superficial morphology. Partial closure of dentinal tubules was observed after irradiation with Er:YAG and Er,Cr:YSGG laser in the 0.25 and 0.50 W protocols. As the energy densities rose, open dentinal tubules, carbonization and cracks were observed. It can be concluded that none of the parameters were capable of eliminating microleakage, however, clinical studies with Er:YAG and Er,Cr:YSGG lasers should be conducted with the lowest protocols in order to determine the most satisfactory setting for dentine hypersensitivity.

Identificador

LASERS IN MEDICAL SCIENCE, LONDON, v. 27, n. 4, supl. 1, Part 3, pp. 827-834, JUL, 2012

0268-8921

http://www.producao.usp.br/handle/BDPI/36661

10.1007/s10103-011-0986-y

http://dx.doi.org/10.1007/s10103-011-0986-y

Idioma(s)

eng

Publicador

SPRINGER LONDON LTD

LONDON

Relação

LASERS IN MEDICAL SCIENCE

Direitos

closedAccess

Copyright SPRINGER LONDON LTD

Palavras-Chave #DENTINE HYPERSENSITIVITY #DENTINE PERMEABILITY #DENTINAL TUBULES #ERBIUM LASERS #ND-YAG LASER #ER-YAG #CERVICAL DENTIN #RADICULAR DENTIN #IRRADIATION #TUBULES #ENGINEERING, BIOMEDICAL #SURGERY
Tipo

article

original article

publishedVersion