936 resultados para Scheduler simulator


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to propose a simple and efficient mechanism to deal with the problem of executing sequential code in a pure dataflow machine. Our results is obtained with a simulator of Wolf [4] architecture. The implemented mechanism improved the architecture performance when executing sequential code and we expect that this improvement could be better if we use some heuristics to deal with some special groups of instructions such as branch operations. Further research will show us if this is true.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work analyzes an active fuzzy logic control system in a Rijke type pulse combustor. During the system development, a study of the existing types of control for pulse combustion was carried out and a simulation model was implemented to be used with the package Matlab and Simulink. Blocks which were not available in the simulator library were developed. A fuzzy controller was developed and its membership functions and inference rules were established. The obtained simulation showed that fuzzy logic is viable in the control of combustion instabilities. The obtained results indicated that the control system responded to pulses in an efficient and desirable way. It was verified that the system needed approximately 0.2 s to increase the tube internal pressure from 30 to 90 mbar, with an assumed total delay of 2 ms. The effects of delay variation were studied. Convergence was always obtained and general performance was not affected by the delay. The controller sends a pressure signal in phase with the Rijke tube internal pressure signal, through the speakers, when an increase the oscillations pressure amplitude is desired. On the other hand, when a decrease of the tube internal pressure amplitude is desired, the controller sends a signal 180° out of phase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Distribution systems with distributed generation require new analysis methods since networks are not longer passive. Two of the main problems in this new scenario are the network reconfiguration and the loss allocation. This work presents a distribution systems graphic simulator, developed with reconfiguration functions and a special focus on loss allocation, both considering the presence of distributed generation. This simulator uses a fast and robust power flow algorithm based on the current summation backward-forward technique. Reconfiguration problem is solved through a heuristic methodology and the losses allocation function, based on the Zbus method, is presented as an attached result for each obtained configuration. Results are presented and discussed, remarking the easiness of analysis through the graphic simulator as an excellent tool for planning and operation engineers, and very useful for training. © 2004 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents Java applet programs for a WWW (world wide web)-HTML (hypertext markup language)-based multimedia course in basic power electronics circuits. These tools make use of the benefits of Java language to provide a dynamic and interactive approach to simulate steady-state idealized rectifiers (uncontrolled and controlled; single-phase and three-phase). In addition, this paper discusses the development and the use of the Java applet programs to assist the teaching of basics rectifier power electronics circuits, and to serve as a first design tool for basics power electronics circuits in the experiments of the laboratories. In order to validate the developed simulation applets, the results were confronted with results obtained from a well-know simulator package PSPICE. © 2005 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Low flexibility and reliability in the operation of radial distribution networks make those systems be constructed with extra equipment as sectionalising switches in order to reconfigure the network, so the operation quality of the network can be improved. Thus, sectionalising switches are used for fault isolation and for configuration management (reconfiguration). Moreover, distribution systems are being impacted by the increasing insertion of distributed generators. Hence, distributed generation became one of the relevant parameters in the evaluation of systems reconfiguration. Distributed generation may affect distribution networks operation in various ways, causing noticeable impacts depending on its location. Thus, the loss allocation problem becomes more important considering the possibility of open access to the distribution networks. In this work, a graphic simulator for distribution networks with reconfiguration and loss allocation functions, is presented. Reconfiguration problem is solved through a heuristic methodology, using a robust power flow algorithm based on the current summation backward-forward technique, considering distributed generation. Four different loss allocation methods (Zbus, Direct Loss Coefficient, Substitution and Marginal Loss Coefficient) are implemented and compared. Results for a 32-bus medium voltage distribution network, are presented and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper deals with the usage of interactive simulations tools to serve as an oriented design tool for the lectures and laboratory experiments in the power electronics courses. A dynamic and interactive visualization of simulations for idealized converters in steady state are provided by the proposed educational tools, allowing students to acquire qualification in non-isolated DC-DC converters, without previous circuitry knowledge, either without the usage of sophisticated simulation packages. The interaction with proposed simulation tools can be accomplished by student using direct or graphic mode. In direct mode the parameters related with the design of converter can be inserted simply editing default values presented in textboxes, while in the graphic mode students interact indirectly with design information by manipulating visual widgets. In order to corroborate the proposed interactive simulation tools, comparisons of results from buck-boost and boost converters on proposed tools and a well-known simulator package with those on experimental evaluation from laboratory classes were presented. © 2009 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to evaluate the control in pre-emergence of the weeds brachiaria grass (Brachiaria decumbens) and goosegrass (Eleusine indica) in different depths in the ground, for the oxyfluorfen and isoxaflutole herbicides, applied in pre-emergence condition and submitted of different rain blades. The experimental design was entirely at random, with four repetitions. Each set was consisted of plastic vases with substratum capacity of 4L, filled with arenaceous ground, increased of brachiaria grass and goosegrass seeds in the depths: 0,5; 1,0; 3,0; 6,0 and 9,0 cm. Doses of 37,5 g a.i. ha -1 of isoxaflutole and 720 g a.i. ha -1 of oxyfluorfen were used. The rain blades was 5, 10 and 20 mm applied with a stationary rain simulator, beyond a treatment without rain. Visual evaluations of control at 7 and 14 days had been carried through after application of the herbicides, counting of germinated plants and dry biomass of plants without application. The development of both weeds was inhibited by herbicides, reaching 100% of control, in all depth levels. The different rain blades had not influenced the control of the weeds. In the biggest depth of sowing (9,0 cm), the emergence was above 45% to B. decumbens and 36% to E. indica in treatments without herbicides application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Petrobras produced green petroleum coke (GPC) is a carbon rich fuel, virtually ash-free, with low sulfur content, and is a fuel suitable to replace metallurgical coke in blast furnaces. The GPC was tested in a pulverized coal injection simulator built in the Volta Redonda research center. It presented a low burning efficiency due to low volatile material content and high substitution rate by the carbon content. The tests were carried out in blast furnaces with ≤ 50% Petrobras GPC in the coal blends. The injected coal/CVP mixtures produced no negative side effects in the blast furnace grinding systems, pneumatic conveying, or operating process. The mixture burning process inside the blast furnace showed a decrease in fuel consumption, with a significant reduction in metallurgical coke consumption. The industrial-scale tests of the GPC mixtures did not reach the 70% maximum for lack of the GPC feedstock, which is necessary to continue with standard coal mixtures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The term human factor is used by professionals of various fields meant for understanding the behavior of human beings at work. The human being, while developing a cooperative activity with a computer system, is subject to cause an undesirable situation in his/her task. This paper starts from the principle that human errors may be considered as a cause or factor contributing to a series of accidents and incidents in many diversified fields in which human beings interact with automated systems. We propose a simulator of performance in error with potentiality to assist the Human Computer Interaction (HCI) project manager in the construction of the critical systems. © 2011 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a careful evaluation among the most usual MPPT (Maximum Power Point Tracking) techniques, doing meaningful comparisons with respect to the amount of energy extracted from the photovoltaic (PV) panel, PV voltage ripple, dynamic response and use of sensors. Firstly, the MPPT and boost converter models were implemented via MatLab/Simulink®, and after a DC to DC boost converter, digitally controlled, was implemented and connected to an Agilent Solar Array simulator, in order to validate the simulation results. The algorithms are digitally developed and the main experimental results are also presented from the implemented prototype. Furthermore, the experimental dynamic results and the computed tracking factors are presented. © 2011 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a careful evaluation among the most usual MPPT techniques, doing meaningful comparisons with respect to the amount of energy extracted from the photovoltaic (PV) panel, PV voltage ripple, dynamic response and use of sensors, considering that the models are first implemented via MatLab/Simulink®, and after a digitally controlled boost DC-DC converter was implemented and connected to an Agilent Solar Array simulator in order to verify the simulation results. The prototype was built, the algorithms are digitally developed and the main experimental results are also presented, including dynamic responses and the experimental tracking factor (TF) for the analyzed MPPT techniques. © 2011 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents evaluations among the most usual MPPT techniques, doing meaningful comparisons with respect to the amount of energy extracted from the photovoltaic panel (PV) (Tracking Factor - TF) in relation to the available power, PV voltage ripple, dynamic response and use of sensors. Using MatLab/Simulink® and DSpace platforms, a digitally controlled boost DC-DC converter was implemented and connected to an Agilent Solar Array E4350B simulator in order to verify the analytical procedures. The main experimental results are presented and a contribution in the implementation of the IC algorithm is performed and called IC based on PI. Moreover, the dynamic response and the tracking factor are also evaluated using a Friendly User Interface, which is capable of online program power curves and compute the TF. Finally, a typical daily insulation is used in order to verify the experimental results for the main PV MPPT methods. © 2011 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents and discusses the main topics involved on the design of a mobile robot system and focus on the control and navigation systems for autonomous mobile robots. Introduces the main aspects of the Robot design, which is a holistic vision about all the steps of the development process of an autonomous mobile robot; discusses the problems addressed to the conceptualization of the mobile robot physical structure and its relation to the world. Presents the dynamic and control analysis for navigation robots with kinematic and dynamic model and, for final, presents applications for a robotic platform of Automation, Simulation, Control and Supervision of Mobile Robots Navigation, with studies of dynamic and kinematic modelling, control algorithms, mechanisms for mapping and localization, trajectory planning and the platform simulator. © 2012 Praise Worthy Prize S.r.l. - All rights reserved.