960 resultados para Resin Curing
Resumo:
PURPOSE: To compare and to evaluate the stability of the retentive force of cobalt-chromium (Co-Cr) circumferential clasps (control) to those with an acetyl resin retentive arm. METHODS: Sixteen specimens with a couple of circumferential clasps were made using Co-Cr over a metal model providing 0.25 mm undercuts. Eight specimens were fabricated without the anterior retentive arm, which was made later using acetyl resin (Dental D). Insertion and removal simulation test was performed through 7250 cycles. The retentive force was recorded in Newtons (N) for periods corresponding to 0, 1, 2, 3, 4, and 5 years. The data were subjected to ANOVA and Tukey test to compare periods and to Student's t test to compare groups (α=0.05). RESULTS: Mean (SD) is presented for Co-Cr and resin groups, respectively: 8.09(3.05) and 2.79(1.57) in period 0; 10.48(4.25) and 3.32(1.92) in 1 year; 10.09(4.15) and 3.47(1.81) in 2 years; 9.87(4.30) and 3.46(1.87) in 3 years; 9.46(3.93) and 3.27(1.59) in 4 years; 9.63(3.79) and 3.41(1.59) in 5 years. There were significant differences for Co-Cr between periods of 0 and 1 (p<0.001), 0 and 2 (p<0.01) and 0 and 3 (p<0.05). In the resin group, no significant differences were found between periods (p>0.05). Comparisons between the groups showed statistical differences for all tested periods: 0 (p=0.0012), 1 (p=0.0013), 2 (p=0.0019), 3 (p=0.0031), 4 (p=0.0027) and 5 years (p=0.0014). CONCLUSIONS: Acetyl resin retentive arms, even if only in the anterior clasps, can significantly reduce the retentive force, but this force remained stable after 5 years of simulated use.
Resumo:
The coexistence of gingival recession (GR) with root coverage indication and non-carious cervical lesions (LCNC) generates the need for a protocol that respects and promotes health of dental and periodontal tissues and allows treatment predictability. The main objectives of this theses were: (1) verify, through clinical evaluations, the connective tissue graft for root coverage on direct and indirect restorations made of ceramic resin; (2) analyze the influence of the battery level of the LED curing unit in the composite resin characteristics; (3) assess the influence of restorative materials, composite resin and ceramics, on the viability of gingival fibroblasts from primary culture. Nine patients with good oral hygiene and occlusal stability diagnosed with LCNCs the anterior teeth including premolars associated with gingival recession (class I and II of Miller) and only gingival recession were selected. After initial clinical examination, occlusal adjustment was performed and the patients had their teeth randomized allocated on direct composite resin restoration of LCNC, polishing and GR treatment with connective tissue graft and advanced coronally flap CR group (n = 15); and indirect ceramic restoration of the LCNC's and GR treatment (CTG+CAF) Group C (n = 15). The GR presented teeth with no clinically formed LCNCs cavity were treated using (CTG+CAF) being the control group (n = 15). Sorption and solubility tests, analysis of the degree of conversion and diametral tensile strength were performed in composite resin samples (n = 10) photoactivated by 100, 50 and 10% battery charge LED unit. The viability of fibroblasts on composite resin, ceramics and dentin disks (n = 3) was examined. Clinical follow-up was performed for three months. The data obtained at different stages were tabulated and subjected to analysis for detection of normal distribution and homogeneity. The results showed that: the LED unit with 10% battery affects the characteristics of the composite resin; restorative materials present biocompatibility with gingival fibroblasts; and the association of surgical and restorative treatment of teeth affected by NCCL and GR presents successful results at 3-month follow-up.
Resumo:
If magnetism is universal in nature, magnetic materials are ubiquitous. A life without magnetism is unthinkable and a day without the influence of a magnetic material is unimaginable. They find innumerable applications in the form of many passive and active devices namely, compass, electric motor, generator, microphone, loud speaker, maglev train, magnetic resonance imaging, data recording and reading, hadron collider etc. The list is endless. Such is the influence of magnetism and magnetic materials in ones day to day life. With the advent of nanoscience and nanotechnology, along with the emergence of new areas/fields such as spintronics, multiferroics and magnetic refrigeration, the importance of magnetism is ever increasing and attracting the attention of researchers worldwide. The search for a fluid which exhibits magnetism has been on for quite some time. However nature has not bestowed us with a magnetic fluid and hence it has been the dream of many researchers to synthesize a magnetic fluid which is thought to revolutionize many applications based on magnetism. The discovery of a magnetic fluid by Jacob Rabinow in the year 1952 paved the way for a new branch of Physics/Engineering which later became magnetic fluids. This gave birth to a new class of material called magnetorheological materials. Magnetorheological materials are considered superior to electrorheological materials in that magnetorheology is a contactless operation and often inexpensive.Most of the studies in the past on magnetorheological materials were based on magnetic fluids. Recently the focus has been on the solid state analogue of magnetic fluids which are called Magnetorheological Elastomers (MREs). The very word magnetorheological elastomer implies that the rheological properties of these materials can be altered by the influence of an external applied magnetic field and this process is reversible. If the application of an external magnetic field modifies the viscosity of a magnetic fluid, the effect of external magnetic stimuli on a magnetorheological elastomer is in the modification of its stiffness. They are reversible too. Magnetorheological materials exhibit variable stiffness and find applications in adaptive structures of aerospace, automotive civil and electrical engineering applications. The major advantage of MRE is that the particles are not able to settle with time and hence there is no need of a vessel to hold it. The possibility of hazardous waste leakage is no more with a solid MRE. Moreover, the particles in a solid MRE will not affect the performance and durability of the equipment. Usually MR solids work only in the pre yield region while MR fluids, typically work in the post yield state. The application of an external magnetic field modifies the stiffness constant, shear modulus and loss modulus which are complex quantities. In viscoelastic materials a part of the input energy is stored and released during each cycle and a part is dissipated as heat. The storage modulus G′ represents the capacity of the material to store energy of deformation, which contribute to material stiffness. The loss modulusG′′ represents the ability of the material to dissipate the energy of deformation. Such materials can find applications in the form of adaptive vibration absorbers (ATVAs), stiffness tunable mounts and variable impedance surfaces. MREs are an important material for automobile giants and became the focus of this research for eventual automatic vibration control, sound isolation, brakes, clutches and suspension systems
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-08
Resumo:
A utilização de espigões em dentes tratados endodonticamente é um dos temas mais estudados em Medicina Dentária. As opiniões são divergentes em relação aos procedimentos clínicos e materiais a serem utilizados para a colocação e remoção de espigões. O objetivo deste trabalho foi realizar uma revisão bibliográfica de forma a organizar conceitos e princípios clínicos para melhor esclarecer os fatores que determinam a necessidade de colocação, utilização e escolha do tipo de espigão, sua cimentação e técnicas para a remoção. Foram analisadas as características e propriedades dos cimentos de fosfato de zinco, ionômero de vidro, cimentos resinosos de polimerização química, polimerização dupla, foto-polimerizável e os sistemas adesivos etch and rinse, self etch e autoadesivos, bem como as técnicas para a remoção de espigões cimentados com diferentes cimentos e sistemas adesivos para depois acessar o remanescente de guta percha para o retratamento endodôntico. Foi feita uma pesquisa bibliográfica na base de dados electrónica PubMed, Google Scholar e RCAAP com as seguintes palavras chave: “Espigões”; “Retratamento Endodôntico”; “Ionómero de Vidro”; “Fosfato de Zinco”; “Cimentos Resinosos”; “Posts”; “Endodontic Retreatment”; “Glass Ionomer”; Zinc-phosphate”; “Resin Cements"; “Push Out Test”; “Posts AND Removal”. Concluiu-se que a cimentação de espigões pré-fabricados de fibra de vidro com cimentos resinosos de dupla polimerização associados aos sistemas adesivos self etch estão gradualmente substituindo os outros tipos de espigões e demais cimentos e possibilitam restaurar o dente de forma adequada e duradoura. E o uso de ultrassons apresenta maior eficácia e segurança na remoção dos espigões.
Resumo:
The publisher regrets to inform the readers that the image that is appearing for Fig. 8 is incorrect and that the Supplementary material is missing on the published paper. The correct image for Fig. 8 and the Supplementary files are provided below: Fig. 8. (a) Timber blocks covered by invented plastic container bottom open, (b) timber blocks in the field after trial, (c) and (d) comparison between resin-coated blocks without termite damage and control blocks which were severely damaged by termites.
Resumo:
The biochemistry of cheese ripening involves mechanisms such as glycolysis, proteolysis and lipolysis. Fatty acids are released by the action of lipases from different sources, milk, rennet, bacteria, moulds included as secondary starters, and other exogenous lipases, during lipolysis [1]. The composition of the lipid fraction contributes positively to the flavour of cheese, for being precursors of more complex aroma compounds responsible for the characteristic “goaty flavour” of goat cheeses [2]. Goat milk is recognized by its easier digestibility, alkalinity, buffering capacity and certain therapeutic values in medicine and human nutrition [3]. A high total content of fatty acids is strongly linked to a rancid and tart off flavour in goat milk and may be considered undesirable in most cheese varieties [4]. In this sense, the purpose of the present study was to examine the composition and changes in fatty acids and saponification value of goat cheese during curing period (2, 7 and 12 months). Goat cheese was made in industrial unit of Cachão - Mirandela (Trás-os- Montes) with raw milk Serrana goats’ race, salt and rennet from animal origin. During the first two months, the samples were stored in a ripening chamber (9.5-11 °C and RH 75-85%). From the second month to one year, the samples were stored in a preservation chamber (10.5-12 °C and RH 75-85%). The fatty acids profile of the inner part of the cheese was analyzed by gas-chromatography coupled to flame ionization detection (GC-FID). The degree of saponification was determined both in the crust and inside the cheese by HCl titration of ethanol KOH solution of the samples. Twenty-six fatty acids (FA) were identified and quantified in the inner part of the cheese (total fat was 45-46 g/100 g during the curing period). Saturated fatty acids (SFA) did not change up to 7 months of curing, increasing only after 12 months, being palmitic (C16:0), stearic (C18:0), myristic (C14:0) and capric (C10:0) acids the most abundant FA in this class. Monounsaturated fatty acids (MUFA) decreased only after 12 months, and oleic acid (C18:1) was the predominant FA. In polyunsaturated fatty acids (PUFA) class, the most abundant were linoleic (C18:2) and linolenic (C18:3) acids, and followed the same tendency of MUFA. This is corroborated by an increase in the degree of saponification, either in the crust as in the inner part of the cheese, after 12 months of curing, probably related with the saturation of the fatty acids [3]. Extra-long curing can be done in cheeses produced with goat milk up to seven months of storage without changing the total fat and individual FA content.
Resumo:
The present study deals with a new analytical procedure based on a cellulose diffusion membrane and immobilised tetraethylene-pentamine-hexaacetate chelator (DM-TEPHA) for an in situ differentiation of labile and inert metal species in aquatic systems. The DM-TEPHA system was prepared by placing TEPHA chelator in pre-purified cellulose bags and in situ applied immersing the system in two Brazilian rivers to study the relative lability of metal species (Cu, Pb, Fe, Mn and Ni) as a function of the time and the quantity of exchanger, respectively. The procedure is simple and enables a new perspective for understanding the complexation, transport, stability and lability of metal species in aquatic systems rich in organic matter.