982 resultados para Reliability (Engineering)
Resumo:
Integrating Science, Technology, and Engineering in Mathematics authors share ideas and activities that stimulate student interest in the integrated fields of science, technology, engineering, and mathematics (STEM) in K–grade 6 classrooms. This article describes an activity that introduced fourth-grade students to the work of aerospace engineers and to the science, technology, and mathematics principles associated with flight.
Resumo:
Resection of musculoskeletal sarcoma can result in large bone defects where regeneration is needed in a quantity far beyond the normal potential of self-healing. In many cases, these defects exhibit a limited intrinsic regenerative potential due to an adjuvant therapeutic regimen, seroma, or infection. Therefore, reconstruction of these defects is still one of the most demanding procedures in orthopaedic surgery. The constraints of common treatment strategies have triggered a need for new therapeutic concepts to design and engineer unparalleled structural and functioning bone grafts. To satisfy the need for long-term repair and good clinical outcome, a paradigm shift is needed from methods to replace tissues with inert medical devices to more biological approaches that focus on the repair and reconstruction of tissue structure and function. It is within this context that the field of bone tissue engineering can offer solutions to be implemented into surgical therapy concepts after resection of bone and soft tissue sarcoma. In this paper we will discuss the implementation of tissue engineering concepts into the clinical field of orthopaedic oncology.
Resumo:
Background The Upper Limb Functional Index (ULFI) is an internationally widely used outcome measure with robust, valid psychometric properties. The purpose of study is to develop and validate a ULFI Spanish-version (ULFI-Sp). Methods A two stage observational study was conducted. The ULFI was cross-culturally adapted to Spanish through double forward and backward translations, the psychometric properties were then validated. Participants (n = 126) with various upper limb conditions of >12 weeks duration completed the ULFI-Sp, QuickDASH and the Euroqol Health Questionnaire 5 Dimensions (EQ-5D-3 L). The full sample determined internal consistency, concurrent criterion validity, construct validity and factor structure; a subgroup (n = 35) determined reliability at seven days. Results The ULFI-Sp demonstrated high internal consistency (α = 0.94) and reliability (r = 0.93). Factor structure was one-dimensional and supported construct validity. Criterion validity with the EQ-5D-3 L was fair and inversely correlated (r = −0.59). The QuickDASH data was unavailable for analysis due to excessive missing responses. Conclusions The ULFI-Sp is a valid upper limb outcome measure with similar psychometric properties to the English language version.
Resumo:
Background: The concept of palliative care consisting of five distinct, clinically meaningful, phases (stable, unstable, deteriorating, terminal and bereavement) was developed in Australia about 20 years ago and is used routinely for communicating clinical status, care planning, quality improvement and funding. Aim: To test the reliability and acceptability of revised definitions of Palliative Care Phase. Design: Multi-centre cross-sectional study involving pairs of clinicians independently rating patients according to revised definitions of Palliative Care Phase. Setting/participants: Clinicians from 10 Australian palliative care services, including 9 inpatient units and 1 mixed inpatient/community-based service. Results: A total of 102 nursing and medical clinicians participated, undertaking 595 paired assessments of 410 patients, of which 90.7% occurred within 2 h. Clinicians rated 54.8% of patients in the stable phase, 15.8% in the unstable phase, 20.8% in the deteriorating phase and 8.7% in the terminal phase. Overall agreement between clinicians’ rating of Palliative Care Phase was substantial (kappa = 0.67; 95% confidence interval = 0.61–0.70). A moderate level of inter-rater reliability was apparent across all participating sites. The results indicated that Palliative Care Phase was an acceptable measure, with no significant difficulties assigning patients to a Palliative Care Phase and a good fit between assessment of phase and the definition of that phase. The most difficult phase to distinguish from other phases was the deteriorating phase. Conclusion: Policy makers, funders and clinicians can be confident that Palliative Care Phase is a reliable and acceptable measure that can be used for care planning, quality improvement and funding purposes.
Resumo:
This thesis investigated risk management and organisational reliability in airports from the perspective of complex sociotechnical systems (CSSs). Two research studies were undertaken, the first focusing on the processes by which disruptive events occur, are detected and responded to; the second exploring the presence of organisational reliability traits within airports. A key result of the studies was the development of new approach: the Critical Incident Disturbance Process model that detailed a means to understand and analyse how disruptions in complex CSSs might be influenced by vulnerability reduction and enhanced risk management. Further, this thesis identified and defined the concept of 'compartmentalised reliability' in complex sociotechnical systems, extending existing knowledge of high reliability theory.
Resumo:
An International Society of Sugar Cane Technologists (ISSCT) Engineering Workshop was held in Piracicaba, Brazil from 30 June to 4 July 2008. The theme of the workshop was Design, manufacturing and maintenance of sugar mill equipment. The workshop consisted of a series of technical sessions and site visits. The Brazilian sugar industry is growing rapidly. The growth has occurred as the result of the sugar industry’s position as a key provider of renewable energy in the form of ethanol and, more recently, electricity. The increased focus on electricity is seeing investment in high pressure (100 bar) boilers, cane cleaning plants that allow an increased biomass supply from trash and digesters that produce biogas from dunder. It is clear that the Brazilian sugar industry has a well defined place in the country’s future. The ISSCT workshop provided a good opportunity to gain information from equipment suppliers and discuss new technology that may have application in Australia. The new technologies of interest included IMCO sintered carbide shredder hammer tips, Fives Cail MillMax mills, planetary mill gearboxes, Bosch Projects chainless diffusers, Fives Cail Zuka centrifugals and Vaperma Siftek membrane systems.
Resumo:
The growing number of potential applications of Unmanned Aircraft Systems (UAS) in civilian operations and national security is putting pressure of National Airworthiness Authorities to provide a path for certification and allow UAS integration into the national airspace. The success of this integration depends not only on developments in improved UAS reliability and safety, but also on regulations for certification, and methodologies for operational performance and safety assessment. This paper focuses on the latter and describes progress in relation to a previously proposed framework for evaluating robust autonomy of UAS. The paper draws parallels between the proposed evaluation framework and the evaluation of pilots during the licensing process. It discusses how the data from the proposed evaluation can be used as an aid for decision making in certification and UAS designs. Finally, it discusses challenges associated with the evaluation.
Resumo:
PURPOSE
The purposes of this study were to:
1) establish inter-instrument reliability between left and right hip accelerometer placement;
2) examine procedural reliability of a walking protocol used to measure physical activity (PA), and;
3) confirm concurrent validity of accelerometers in measuring PA intensity as compared to the gold standard of oxygen consumption measured by indirect calorimetry.
METHODS
Eight children (mean age: 11.9; SD: 3.2, 75% male) with CP (GMFCS levels I-III) wore ActiGraph GT3X accelerometers on each hip and the Cosmed K4b