976 resultados para Push-out test
Resumo:
The present study evaluates the humoral and cellular immune responses in 35 volunteers submited to short antirabies vaccination schedules with the Fuenzalida & Palacios vaccine based on the administration of doses on non consecutive days. The volunteers were divided into two groups. The first group received a total number of five doses given on days 0, 4, 7, 20 and 35. The other group received four doses, the first one being a double dose given on day 0 and than three other single doses on days 7, 20 and 35. The evaluation of humoral immune response was carried out by serum neutralization (SN) and indirect immunofluorescense (IIF) tests, while the cellular immune response was evaluated by lymphoblastic transformation assay (LTA) and skin test (ST). According to our results these reduced schedules elicited early and effective humoral and cellulafimmune responses to rabies antigen suggesting that new reduced schedules should be extensively studied in order to give the proper bases to the proposition of changes in the current long-term schedule.
Resumo:
We used the micro- and macroimmunodiffusion test for the qualitative and quantitative measurement of anti - P. brasiliensis antibodies in serum of patients with paracoccidioidomycosis. All 103 paracoccidioidomycosis sera (100%) were positive in the micro test versus 87% positivity index in the macrotest. All 83 control sera from patients with other diseases were negative in both tests. Titers of the positive sera tended to be higher in the microtest, which revealed sharper and easier to read precipiting bands. Microimmunodiffusion is simple to be performed, requires a minimum amount of reagents and allows the simultaneous testing of 102 sera. It may replace the macrotest specially in laboratories dealing with great serologic routine.
Resumo:
Dissertação de Mestrado Apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Contabilidade e Finanças, sob orientação do Mestre Adalmiro Álvaro Malheiro de Castro Andrade Pereira.
Resumo:
Introduction: Anxiety is a common problem in primary care and specialty medical settings. Treating an anxious patient takes more time and adds stress to staff. Unrecognized anxiety may lead to exam repetition, and impedance of exam performance. Objective: The aim of the study was to examine the anxiety levels of patients who are to undergo diagnostic exams related to cancer diagnostic: PET/CT and mammography. Methods: Two hundred and thirty two patients who undergo PET/CT and one hundred thirteen women who undergo mammography filled out one questionnaire after the procedure to determine their concerns, expectations and perceptions of anxiety. Results: Our results show that the main causes of anxiety in patients who are having a PET/CT is the fear of the procedure itself and fear of the results. Patients who suffered from greater anxiety were those who were scanned during the initial stage of an oncological disease. On the other hand, the diagnostic is the main cause of anxiety in women who are requiring a mammography. 28% of the women reported having experienced pain or intense pain. Conclusions: The performance of diagnostic exams related to cancer diagnostic like a PET/CT and a mammography are important and statistically generators of anxiety. Patients are often poorly informed and present with a range of anxieties that may ultimately affect examination quality. These results provide expertise that can be used in the development of future training programs to integrate post-graduate courses of health professionals.
Resumo:
Trabalho Final de mestrado para obtenção do grau de Mestre em Engenharia Mecânica perfil Manutenção e Produção
Resumo:
In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.
Resumo:
Sera from the patients (N = 10) with schistosomiasis mansoni of the hospital of Federal University of Pernambuco, the Schistosoma mansoni egg-positive (N = 51) and -negative (N = 452) inhabitants in Cabo City area, out-patients (N = 37) of the IMIP hospital and Japanese immigrants (N = 127) in Petrolina City area of northeast Brazil as well as Japanese healthy subjects (N = 30) were examined by serological tests including an enzyme-linked immunosorbent assay with antigens prepared from eggs (ELISA-egg) and adult worms (ELISA-adult). The ELISA with egg or adult antigen correctly identified 100% of the uninfected individuals lived in non-endemic area of schistosomiasis. Moreover, when examined cross-reactivity of our ELISA with sera isolated from 78 subjects infected with various intestinal parasitic infections, only one of these sera reacted with the egg and adult antigens. On the examination of 51 sera from the egg-positive subjects, the ELISA-egg revealed the highest sensitivity (98.0%), whereas a large number of false negative reactions of ELISA-adult, Ouchterlony method using adult antigen, circumoval precipitation and immediate intradermal skin test were observed. A low sensitivity of these serologic tests except for ELISA-egg appears to be primarily due to their inability to detect antibody in the sera from egg-positive infantiles. There was no positive correlation between the absorbance values of these two types of ELISA among the sera isolated from ELISA-positive subjects. Rather, by the reactivity of these sera to egg or adult antigen, they could be divided into two subgroups; one reacted more positively with egg antigen and the other with adult antigen. Moreover, it was confirmed that the sera from young subjects (under 20 years old) appear to be highly reactive to the egg antigen than did aged ones. These data suggest that the ELISA with egg antigen, but not with the adult antigen, appears to be useful for the serological survey of schistosomiasis mansoni in the endemic area of northeast Brazil.
Resumo:
Between October 1988 and April 1989 a cross-sectional survey was carried out in six out of eight blood banks of Goiânia, Central Brazil. Subjects attending for first-time blood donation in the mornings of the study period (n = 1358) were interviewed and screened for T. cruzi infection as a part of a major study among blood donors. Tests to anti-T. cruzi antibodies were performed, simultaneously, by indirect hem agglutination test (IHA) and complement fixation test (CFT). A subject was considered seropositive when any one of the two tests showed a positive result. Information on age, sex, place of birth, migration and socio-economic level was recorded. Results from this survey were compared with seroprevalence rates obtained in previous studies in an attempt to analyse trend of T. cruzi infection in an endemic urban area. The overall seroprevalence of T. cruzi infection among first-time donors was found to be 3.5% (95% confidence interval 2.5%-4.5% ). The seroprevalence rate increased with age up to 45 years and then decreased. Migrants from rural areas had higher seroprevalence rates than subjects from urban counties (1.8%-16.2% vs. 0%-3.6%). A four fold decrease in prevalence rates was observed when these rates were compared with those of fifteen years ago. Two possible hypotheses to explain this difference were suggested: 1. a cohort effect related with the decrease of transmission in rural areas and/or 2. a differential proportion of people of rural origin among blood donors between the two periods. The potential usefulness of blood banks as a source of epidemiological information to monitor trends of T. cruzi infection in an urban adult population was stressed.
Resumo:
Mestrado em Gestão e Avaliação de Tecnologias em Saúde
Resumo:
Parasitological examinations were carried out during July to December, 1989, on 485 inhabitants of four villages in São Lourenço da Mata, 25 km northwest of Recife, Pernambuco, Brazil. Approximately 99.6% of the inhabitants were infected with at least one species of intestinal parasites. A high prevalence of Schistosoma mansoni (82.1%), hookworm (80.2%) Trichuris trichiura (69.9%), Ascaris lumbricoides (61.9%) and Entamoeba coli (36.7%) infections were demonstrated. Test tube cultivation revealed that the most common species of hookworm in this region was Necator americanus (88.4%), and also that the prevalence of Strongyloides stercoralis was 5.8%. Three hundred and thirty-four sera were serologically examined for amoebiasis by the gel diffusion precipitation test (GDP) and enzyme-linked immunosorbent assay (ELISA). No positive reaction was observed in all sera as examined by GDP, while 24 sera were positive by ELISA.
Resumo:
Le test ELISA-TÉTANOS (Biosys, France) a été utilisé pour le titrage des anti-corps tétaniques (sensibilité = 0,0025 UI/ml) en sérums humains de donneurs de sang, 566 hommes et 108 femmes, âges de 18 à 58 ans, moyenne de 29 ans, provenant de São Paulo, SP, Brésil. L'OMS, acceptant seulement la séroneutralisation sur souris (NT), la méthode de référence, pour les études sur la protection contre le tétanos, préconise le titre de 0,01 UI/ml comme minimum protecteur. BOURLEAUD & HUET ont proposé la limite de 0,06 UI/ml quand s'emploie le test ELISA, en attendant à une certaine discordance inévitable entre les méthodes. Parmi les 674 sérums étudiés, 178 (26,41%) n'ont pas présenté d'anticorps (< 0,0025 UI/ml); 413 (61,28%) ont présenté des résultats égaux ou supérieurs à 0,01 UI/ml et en 232 (34,42%) les titres ont été égaux ou supérieurs à 0,06 UI/ml. Le pourcentage d'individus protégés a été inversement proportionnel à 1'âge: environ 50% dans le groupe le plus jeune (hommes de 18 à 35 ans et femmes de 18 à 23 ans) contre environ 10% dans le groupe de plus de 42 ans ont présenté des titres sûrement protecteurs (> 0,06 UI/ml).
Resumo:
Helicobacter pylori was investigated in 189 patients for culture, microscopic visualization of campylobacter-like organisms (CLO) and a ten minute urease test. In 136 (72%) the bacteria was isolated, and in 98 of them CLO were histologically detected. Specificity, sensitivity, positive and negative predictive values of microscopic visualization of CLO were: 0.77, 0.73, 0.97 and 0.51, respectively; 98 culture-positive patients were urease test positive. Specificity, sensitivity, positive and negative predictive values of the urease test were: 0.83, 0.72, 0.92 and 0.54, respectively. Comparing the urease test with culture of H. pylori combined with microscopic visualization of CLO, its specificity, sensitivity, positive and negative predictive values were: 0.95, 0.71, 0.98 and 0.48, respectively. Probably, these values are not real, since bacteria different from H. pylori could be misclassified as CLO.
Resumo:
A survey of the prevalence of Trypanosoma cruzi infection was carried out in Oitis, a small community in the State of Piaui, Brazil. Two hundred and sixty five individuals were screened by microscopic examination, hémoculture, indirect immunofluorescence (IFA), enzyme-linked immunosorbent assay (ELISA), and competitive enzyme-linked immunosorbent assay (C-ELISA) using the monoclonal antibody TCF87 against to a 25kd T. cruzi antigen. Seropositivity was 14.3% by the IFA test, 14.7% by ELISA, and 13.2% by C-ELISA. The C-ELISA using the TCF87 monoclonal antibody seems to be applicable in serodiagnosis of Chagas' disease.
Resumo:
The performance of an antigen of L. major-like promastigotes for the serological diagnosis of mucocutaneous leishmaniasis in the IgG-immunofluorescent test was compared to that of an antigen of L. braziliensis braziliensis. Each antigen was used to test two hundred and twenty-four sera of etiologies such as mucocutaneous leishmaniasis, deep mycoses, toxoplasmosis, malaria, Chagas' disease, visceral leishmaniasis, anti-nuclear factor, schistosomaiasis, rheumatoid factor and normal controls. Agreement between responses to each antigen was high: 77.2% of leishmaniases sera agreed on a positive or a negative result to both antigens and 91.1 % of control sera. Cross reactivity was restricted to Chagas' disease sera, visceral leishmaniasis, anti-nuclear factor and paracoccidiodomycosis. The quantitative response of leishmaniasis and Chagas' disease sera to both antigens was evaluated by a linear regression; although the y-intercept and the slope were different for each antigen, neither was better than the other in the disclosure of anti-Leishmania antibodies. In the case of Chagas' disease sera the L. major-like antigen was better than L. b. braziliensis' to disclose cross-reacting antibodies.
Resumo:
CO2 capture from gaseous effluents is one of the great challenges faced by chemical and environmental engineers, as the increase in CO2 levels in the Earth atmosphere might be responsible for dramatic climate changes. From the existing capture technologies, the only proven and mature technology is chemical absorption using aqueous amine solutions. However, bearing in mind that this process is somewhat expensive, it is important to choose the most efficient and, at the same time, the least expensive solvents. For this purpose, a pilot test facility was assembled and includes an absorption column, as well as a stripping column, a heat exchanger between the two columns, a reboiler for the stripping column, pumping systems, surge tanks and all necessary instrumentation and control systems. Some different aquous amine solutions were tested on this facility and it was found that, from a set of six tested amines, diethanol amine is the one that turned out to be the most economical choice, as it showed a higher CO2 loading capacity (0.982 mol of CO2 per mol of amine) and the lowest price per litre (25.70 ¤/L), even when compared with monoethanolamine, the benchmark solvent, exhibiting a price per litre of 30.50 ¤/L.